Top Banner
In Summary….
18

In Summary….

Feb 23, 2016

Download

Documents

Kayo

In Summary…. Understand?. Could you label this???. ECG Paper. ECG Paper and Standardization. Standardization Signal Without a standardization signal, the ECG paper is merely graph paper. By entering a signal, you place value on each of the smallest squares. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: In Summary….

In Summary….

Page 2: In Summary….

Understand?

Page 3: In Summary….

Could you label this???

Page 4: In Summary….

ECG Paper

Page 5: In Summary….

ECG Paper and Standardization• Standardization Signal

– Without a standardization signal, the ECG paper is merely graph paper. By entering a signal, you place value on each of the smallest squares.

– At 1 cm=1 mv each tiny square represents 0.1 mv in height (amplitude) and 0.02 seconds in width (duration) at a paper speed of 50 mm/sec.

– At a paper speed of 25 mm/sec, each tiny square represents 0.04 seconds, every large box (5 small boxes) represents 0.20 seconds, and every 15 large boxes (set) = 3 seconds.

– The calibration signal can be changed, if necessary, to affect amplitude only.

Page 6: In Summary….

Baseline or Isoelectric Line

Positive charges

Negative charges

Page 7: In Summary….

Normal ECG Tracing

Page 8: In Summary….

Common Technical Pitfalls

• Incorrect lead placement• Paper speed• Motion artifacts• Breathing/respiratory movement• Purring

Page 9: In Summary….

Artifacts• The word artifact is similar to artificial in the sense

that it is often used to indicate something that is not natural (i.e. man-made). In electrocardiography, an ECG artifact is used to indicate something that is not "heart-made." These include (but are not limited to) electrical interference by outside sources, electrical noise from elsewhere in the body, poor contact, and machine malfunction. Artifacts are extremely common, and knowledge of them is necessary to prevent misinterpretation of a heart's rhythm

Page 10: In Summary….

Muscle Tremor Interference• If your patient is not calm and comfortable, or just really

nervous and shaky…the reading may look like this. Also caused by happy, purring feline patients

• Reapplying or readjusting the clips may help• A towel or blanket can be placed on patient to help calm

them• You can also place your hand on the chest of the patient,

taking care not to apply too much pressure (will interfere with reading)

Page 11: In Summary….

Patient Movements

Page 12: In Summary….

Electrical Interference

• Remember that rubber mat and how you checked your machine for causes of bad ground?

• Interference can be caused by other machinery such as a pulse oximeter or BP monitor that is hooked up to animal; even fluorescent lighting

Page 13: In Summary….

Loose Electrodes

Page 14: In Summary….

ECG Tracings of Common Arrhythmias

• Please refer to your ECG handout

• Reading assignment VTDRG: Pg 205-220, 338-345

Page 15: In Summary….

Classification of Arrhythmias

• Definition– An abnormality in the rate, regularity, or site of

origin of the cardiac impulse– A disturbance in conduction of the impulse such

that the normal sequence of activation of the atria and ventricles is altered

Page 16: In Summary….

Classification of Arrhythmias

• Normal sinus impulse formation– Normal sinus rhythm– Sinus arrhythmia

• Disturbances of sinus impulse formation– Sinus bradycardia– Sinus tachycardia

• Disturbances of supraventricular impulse formation– Atrial premature complexes– Atrial tachycardia– Atrial flutter– Atrial fibrillation

Page 17: In Summary….

Disturbances of ventricular impulse formation– Ventricular premature complexes– Ventricular tachycardia– Ventricular systole– Ventricular asystole– Ventricular fibrillation

Disturbances of impulse conduction– Sinus arrest or block– Atrial standstill– Ventricular pre-excitation– First-degree AV block– Second degree AV block– Third degree AV block– Left bundle branch block– Right bundle branch block

Page 18: In Summary….

Building Blocks for Arrythymia Interpretation

• Recognize the site of origin of the abnormal beat• Recognize deviations from the normal rate of

automaticity for that site• Site of Origin

– Atrial• Positive deflection P waves are present with a constant P-R interval and normal

duration QRS complex– Junctional

• Negative deflection P waves, or no P waves with a normally conducted short QRS complex

– Ventricular• No P waves are evident, QRS complexes are wide and bizarre appearing and may

be positive or negative polarity depending on which ventricle is the site of origin