Top Banner
13/12/2007 In-situ calibration with In-situ calibration with Zee events Zee events Nikola Makovec Group meeting
15

In-situ calibration with Zee events

Jan 14, 2016

Download

Documents

aldona

In-situ calibration with Zee events. Nikola Makovec Group meeting. Outline. CSC Note EG-6, section Intercalibration Motivation Data sample and event selection Description of the method The fitting method Reference distribution Method testing - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: In-situ calibration with Zee events

13/12/2007

In-situ calibration with Zee In-situ calibration with Zee eventsevents

Nikola MakovecGroup meeting

Page 2: In-situ calibration with Zee events

Nikola Makovec 2

OutlinOutlinee CSC Note EG-6, section Intercalibration

Motivation Data sample and event selection Description of the method

The fitting method Reference distribution

Method testing Results with misaligned and distorted geometry Conclusion

8 pages

Page 3: In-situ calibration with Zee events

Nikola Makovec 3

MotivatioMotivationnIn situ calibration of the EM calorimeter with

Zee events:

Intercalibration Non-uniformities

Temperature Purity Extra-material in front of the calorimeter

Local constant term ~0.5% (=0.20.4) Goal : 0.7% (TDR) Intercalibrate these regions to a level of 0.4%

Absolute energy scale Physics atlas program : ~0.1% W mass measurement : ~0.02%

LRL CCC

Page 4: In-situ calibration with Zee events

Nikola Makovec 4

Data sample and event Data sample and event selectionselection Data sample :

Trig1_misal1_csc11_V1.005144.PythiaZee.recon.NTUP.v12000601 Studies at the generator level

Trig1_misal1_csc11_V1.005144.PythiaZee.recon.NTUP.v13003002 Used after simulation and reconstruction

Event selection at least electrons The 2 leading should satisfy

pT>20GeV ||<2.4 IsEM(Medium)=true

80<Mee<100

Page 5: In-situ calibration with Zee events

Nikola Makovec 5

Description of the method (1)Description of the method (1)

Notation:

The fitting method: 2 step : Measurement

Minimising the following log-likelihood :

generalized least squared method is applied leading to an analytical solution.

Page 6: In-situ calibration with Zee events

Nikola Makovec 6

Description of the method (2)Description of the method (2)

The reference distribution

Page 7: In-situ calibration with Zee events

Nikola Makovec 7

Method testing (1)Method testing (1)

Done at the generator level Injected bias drawn from a Gaussian(,) Gaussian(0,2%)

Page 8: In-situ calibration with Zee events

Nikola Makovec 8

Method testing (2)Method testing (2)

Gaussian(,2%)

Page 9: In-situ calibration with Zee events

Nikola Makovec 9

Method testing (3)Method testing (3)

Expected constant term as a function of the luminosity

Page 10: In-situ calibration with Zee events

Nikola Makovec 10

Results with misaligned and distorted geometry (1)Results with misaligned and distorted geometry (1)

Gaussian(0,0%)

Page 11: In-situ calibration with Zee events

Nikola Makovec 11

Results with misaligned and distorted geometry (2)Results with misaligned and distorted geometry (2)

Page 12: In-situ calibration with Zee events

Nikola Makovec 12

Results with misaligned and distorted geometry (3)Results with misaligned and distorted geometry (3)

Gaussian(0,2%)

Page 13: In-situ calibration with Zee events

Nikola Makovec 13

Results with misaligned and distorted geometry (4)Results with misaligned and distorted geometry (4)

Page 14: In-situ calibration with Zee events

Nikola Makovec 14

ConclusioConclusionn With~200pb-1:

Constant term ~ 0.7% Absolute scale known with a precision of few

percent

Care of extrapolation to other energy spectrum (linearity?)

Amount of material in front of the detector : E/p Conversion Energy flow

Page 15: In-situ calibration with Zee events

Nikola Makovec 15

To do listTo do list

Corrections de la note : Fond? Forme Style et orthographe

Si vous avez un peu de temps: /exp/atlas/makovec/Notes/CSC-EG-6.pdf

Photo non contractuelle

Pot pour mon retour au LAL :Vendredi 21 décembre à

11h30 Salle 129