The EasyPulse5 has 5 pulse settings and a 2 l/min continuous flow setting.(available with no gauge)
The EasyPulse5+6 has 6 continuous flow settings to compliment the 5 pulse settings.
198705 195405
EasyPulse5 vs 2 l/min Continuous Flow
Pulse Volumes & Delivered Minute Volumes
Market Leading Oxygen Conserving TechnologyThe EasyPulse5 utilizes Controlled Minute Volume (CMV) Oxygen Conserving Technology.
Precision Medical’s patented CMV Technology delivers a pulse algorithm wave form, superior trigger sensitivity and fast delivery time. All this is accomplished pneumatically with a single lumen cannula.
CMV Technology is the most efficient, reliable and clinically sound conserving technology available today.
SettingPulse Volume @ Breath Rate of: Minute
Volume15 20 25 30
1 17 ml 15 ml 10 ml 9 ml 300 ml/min2 28 ml 21 ml 17 ml 14 ml 420 ml/min3 37 ml 28 ml 22 ml 19 ml 560 ml/min4 47 ml 35 ml 28 ml 23 ml 700 ml/min5 57 ml 43 ml 34 ml 29 ml 860 ml/min
2 l/min N/A 2000 ml/min (2 l/min)Minute Volume Consistent @ 12 - 35 BPM
Precision Medical, Inc.300 Held Drive • Northampton, PA 18067 USA
Phone: 610-262-6090 Toll-Free Phone: 800-272-7285Fax: 610-262-6080 Toll-Free Fax: 800-352-1240
www.precisionmedical.com505727rev1 ??m 7/16 Printed in USA
Specifications
Ordering Information
198705 Models 195405 Models 198712 ModelsDimensions: Length: 4.8 in (12.1 cm)
Width: 2.6 in (6.8 cm)Height: 2.5 in (6.4 cm)
Length: 2.5 in (6.4 cm)Width: 1.9 in (4.9 cm)Height: 2.9 in (7.5 cm)
Length: 4.8 in (12.1 cm)Width: 2.6 in (6.8 cm)Height: 2.5 in (6.4 cm)
Weight: 198705: 9.86 oz (.28 kg)198705NG: 9.40 oz (.27 kg)
195405: 12.6 oz (.36 kg)195405NG: 10.0 oz (.28 kg) 9.86 oz (.28 kg)
Inlet Pressure Range: 300-3000 psig(2068-20684 kPa)
Internal Regulated Pressure: 50 psig(345 kPa)
Operating Altitude Range: Sea level to 10,000 ft above sea level(Sea level to 3,048 m above sea level)
Pulse Settings: 1, 2, 3, 4 and 5Flow Settings: 2 l/min Continuous 1, 2, 3, 4, 5 and 6 l/min
Continuous Savings Ratio: Up to 5.7 : 1Cannula Requirements: Maximum 7 ft long adult standard single lumen oxygen nasal cannulaOxygen Cylinder Connections: CGA 870 Post Valve CGA 540 Nut Style CGA 870 Post ValveWarranty: 2 yearsSpecifications are subject to change without prior notice.
Part # Description
198705 EasyPulse5 Conserving Regulator with 1 Adult Single Lumen O2 Nasal Cannula
198705C EasyPulse5 Complete Set-up (Regulator, M6 Cylinder with Post Valve, M4/M6 Cylinder Bag, 1 Adult Single Lumen O2 Nasal Cannula)
198705NG EasyPulse5 Conserving Regulator with CGA 870 Connection and No Gauge
195405 EasyPulse5 Conserving Regulator with CGA 540 Connection
195405NG EasyPulse5 Conserving Regulator with CGA 540 Connection with No Gauge
198712 EasyPulse5+6 Conserving Regulator with 1 Single Lumen Cannula
1221-25 Yoke Seal (pack of 25)
1221-50 Yoke Seal (pack of 50)
503943 M6 Cylinder with CGA 870 Post Valve
504833 Adult Single Lumen O2 Nasal Cannula (4 ft)
504833-25 Adult Single Lumen O2 Nasal Cannula (case of 25)
503920 Carry Bag (fits M6 cylinder)
504184 Carry bag (fits M4 and M6 cylinders)
504185 Carry bag (fits ML6 and M9 cylinders)
Specifications &Ordering Information