SURPASS hiX5625 R2.8Install G400/G400R/G400 2G/G400R 2G

IP-DSLAM

Install G400/G400R/G400 2G/G400R 2G

The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright Nokia Siemens Networks 2008 - 2009. All rights reserved

f

Important Notice on Product SafetyElevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures. Non-observance of these conditions and the safety instructions can result in personal injury or in property damage. Therefore, only trained and qualified personnel may install and maintain the system. The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.

The same text in German: Wichtiger Hinweis zur Produktsicherheit In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen. Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungen und Sachschden fhren. Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet. Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

2

Id:0900d805805f0f54

Install G400/G400R/G400 2G/G400R 2G

Table of ContentsThis document has 98 pages. Change History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 1.10 1.11 2 2.1 2.2 2.3 2.4 2.5 2.6 3 3.1 3.2 3.3 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 4 4.1 4.2 5 5.1 5.2 5.2.1 5.2.2 5.2.3 5.2.4 6 6.1 Protective Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protection Against Excessive Contact Voltage . . . . . . . . . . . . . . . . . . . Protection Against Escaping Laser Light . . . . . . . . . . . . . . . . . . . . . . . . Protection Against Fire in Racks or Housings . . . . . . . . . . . . . . . . . . . . Protection Against Hot Surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Components Subject to Electrostatic Discharge . . . . . . . . . . . . . . . . . . Handling Modules (General) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handling Optical Fiber Connectors and Cables. . . . . . . . . . . . . . . . . . . RoHS Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Declaration of CE Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WEEE Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . G400, G400R, G400 2G and G400R 2G Shelf Mechanics . . . . . . . . . . Shelf Integration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Items Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tools and Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplemental Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Set up and Equip the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Infrastructure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Constructing the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Equipping the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install a Subrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install the Splitter Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ground the Subrack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install the AC/DC Converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install the Terminal Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 11 11 12 12 13 13 14 15 15 16 16 17 17 17 18 18 18 19 20 20 20 22 22 25 26 26 26

Equipping the Shelves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Equipping of the Shelves G400 and G400 2G. . . . . . . . . . . . . . . . . . . . 28 Equipping of the Shelf G400R and G400R 2G . . . . . . . . . . . . . . . . . . . 29 Cable the Rack Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable the External DC Power to the Fuse Panel. . . . . . . . . . . . . . . . . . Connect the AC/DC Converter hiX PS 48/30. . . . . . . . . . . . . . . . . . . . . Connect the DC Fuse Panel and AC/DC Converter . . . . . . . . . . . . . . . Connect the AC/DC Converter and AC Power Fuse Panel . . . . . . . . . . Connect the AC Fuse Panel to AC Mains . . . . . . . . . . . . . . . . . . . . . . . Connect the Control Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 32 33 33 33 34 35

Cable the CXU and PM Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Overview CXU Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Id:0900d805805f0f54

3

Install G400/G400R/G400 2G/G400R 2G

6.2 6.2.1 6.2.1.1 6.2.1.2 6.2.1.3 6.2.2 6.2.3 6.3 6.4 6.5 6.6 6.7 7 7.1 7.1.1 7.1.2 7.1.3 7.1.4 7.1.5 7.1.6 7.1.7 7.2 7.2.1 7.2.2 7.2.3 7.2.4 7.2.5 7.2.6 7.2.7 7.3 7.3.1 7.3.2 7.3.3 7.3.4 7.3.5 7.4 7.4.1 7.4.2 7.4.3 7.4.4 7.4.5 7.4.6 7.4.7 8 9 9.1

Connect the Uplink Interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Optical Interfaces to Distributor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Optical and Electrical Interfaces on CXU_C . . . . . . . . . . . . . . . . . . . . . . 38 Connect Optical Interfaces of the CXU_C . . . . . . . . . . . . . . . . . . . . . . . 38 Connect Optical Interfaces of the CXU_C2/B21/B3 . . . . . . . . . . . . . . . . 39 Connect Electrical Ethernet Interfaces to Distributor . . . . . . . . . . . . . . . 40 Install a CWDM Ring Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Connect the Outband Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Overview of PM Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Connect the Alarm Lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Connect the Test- and Control Interfaces . . . . . . . . . . . . . . . . . . . . . . . . 44 Connect the External Reference Clock. . . . . . . . . . . . . . . . . . . . . . . . . . 47 Cable the Subscriber Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Interface Unit IU_VDSL24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Connector Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Pre-fabricated Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Connect IU_VDSL24 and MDF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Connect IU_VDSL24 and Splitter Board. . . . . . . . . . . . . . . . . . . . . . . . . 50 Connect Splitter Board and MDF . . . . .