Top Banner
E17 g ET23.5 i T 11 BT-28S ET-181 BT-37 W E-25 LUMALUX® ILUMALUXPLUS T 7ECO™ Non cycling, environmentally friendlier high pressure sodium. IPIBB , 70 ET-23/i Mog 67497 100 ET-23 1 ^ Mog 67559 150 ET-23'/£ Mog 67494 200 ET-18 Mog 67495 250 ET-18 Mog .67572 400 ET-18 Mog 67312 Ordering Abbreviation LU70/PLUS/ECO ANSI Spec. Number S62CX LU100/PLUS/ECO S54CX LU150/55/PLUS/ECO S55CX LU200/PLUS/ECO S66EJ LU250/PLUS/ECO S50EJ LU400/PLUS/ECO S51EJ Pkg. dry. 20 20 20 20 20 20 Description Clear 28 Clear 28 Clear 28 Clear 28 Clear 28 Clear 28 Life Avg. Rated Hours 24000 24000 24000 24000 24000 24000 Approx. Lumens Initial Mean 6300 5600 9500 8550 16000 14400 22000 19800 29000 26100 50000 45000 LC.L 5 5 5 5% 5% 5% M.O.I. TA TA TA 9% 9% 9% STANDARD LUMALUX General lighting high pressure sodium.. 35 E-17 Med. 67500 ; 67501 50 E-17 Med. 67502 67503 ET-23^ Mog 67510 67511 70 E-17 Med. 67504 67505 ET-23!^ Mog 67512 67513 100 E-17 Med. 67506 67507 ET-23^ Mog 67514 67515 150 E-17 Med. 67508 67509 ET-23 1 /: Mog 67516 67517 BT-28 Mog 67518 200 ET-18 Mog 67576 250 ET-18 Mog 67578 BT-28 Mog 67521 310 ET-18 Mog 67580 350 T-m Mog 67613 400 ET-18 Mog 67533 BT-37 Mog 67524 T-7 RSC 67527 430 T-14.5 Mog 67615 600 T-16 Mog 67614 67616 750 BT-37 Mog 67547 1000 E-25 Mog 67307 LU35/MED LU35/D/MED LU50/MED LU50/D/MED LU50 LU50/D LU70/MED LU70/D/MED LU70 LU70/D LU100/MED LU100/D/MED LU100 LU100/D LU150/MED LU150/D/MED LU1 50/55 LU150/55/D LU150/100 LU200 LU250 LU250/D LU310 S76ZL S76ZL S68ZL S68ZL S68NV S68IW S62ZL S62ZL S62CX S62CX S54ZL S54ZL S54CX S54CX S55ZL S55ZL S55CX S55CX S56KA S66EJ S50EJ S50KA S67EJ LU350 SUPER D N/A LU400 LU400/D LU400T7RSC S51EJ S51ZC S51 LU430PLANTAD S51GJ LU600 SUPER S106GC LU600PLANTAD S106GC LU750 LU1000 S111ZC S52XB 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 10 20 20 10 20 10 20 10 10 10 10 10 6 6 Clear Coated 6 Clear Coated 6 Clear Coated 6 Clear Coated 6 Clear Coated 6 Clear Coated 6 Clear Coated 6 Clear, 55 Volt Coated, 55 Volt 6 Clear, 55 Volt 7 Coated, 55 Volt 6 - 7 Clear, 100 Volt 7 Clear Clear Coated 6 Clear Clear Clear Coated 6 Clear Clear Clear Clear Clear 14 Clear 14 16000+ 16000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 24000+ 18000 24000+ 24000+ 24000 18000 18000 18000 24000 24000+ 2250 2050 2100 1935 4000 3600 3700 3420 4000 3600 3700 3420 6300 5350 5800 4900 6300 5500 5800 4900 9500 8000 8800 7500 9500 8000 8800 7500 15800 13400 14500 12300 16000 13800 14700 12500 15700 14100 22000 19800 29000 26100 26000 23400 37000 33300 46500 44000 50000 45000 47500 42300 46000 41400 51500 42400 92000 81000 84000 75000 105000 94500 130000 120700 3 7 / 6 3^6 3 ? /6 3 7 /6 5 5 3 7 /6 3 ? /6 5 5 3 7 /6 3 ? /6 5 5 3 9 /6 3'/6 5 5 5 5 3 / 5% 5 5% 5% 5% 1 5 6% 6% 6% 6% 8% 5'/6 514 5!4 5!4 Tk TA 5 7 /6 5 7 /6 TA TA 5 7 /6 5'/6 TA TA 5% 5% TA TA 8 5 /6 9% 9% 8 5 A 9% 9M 9% m 10K 6 m 11% m 115* 1514 Energy Saving Product/Value Added Product I I High Color Rendering Lamp New Item Footnotes/Symbols pages 167-169
2

ILUMALUXPLUST Non cycling, environmentally friendlier high ......auto-transformer; or a 240 or 277 volt reactor for the 150W, 215W, 360W lamps and a 480 volt reactor for the 880W lamp.

May 25, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ILUMALUXPLUST Non cycling, environmentally friendlier high ......auto-transformer; or a 240 or 277 volt reactor for the 150W, 215W, 360W lamps and a 480 volt reactor for the 880W lamp.

E17 g ET23.5 i T11 BT-28S ET-181 BT-37 W E-25

LUMALUX®ILUMALUXPLUST7ECO™Non cycling, environmentally friendlier high pressure sodium.

IPIBB ,70 ET-23/i Mog 67497100 ET-231^ Mog 67559150 ET-23'/£ Mog 67494200 ET-18 Mog 67495250 ET-18 Mog .67572400 ET-18 Mog 67312

OrderingAbbreviation

LU70/PLUS/ECO

ANSISpec.

NumberS62CX

LU100/PLUS/ECO S54CXLU150/55/PLUS/ECO S55CXLU200/PLUS/ECO S66EJLU250/PLUS/ECO S50EJLU400/PLUS/ECO S51EJ

Pkg.dry.202020202020

DescriptionClear28

Clear28

Clear28

Clear28

Clear28

Clear28

LifeAvg.

RatedHours

240002400024000240002400024000

Approx.Lumens

Initial Mean6300 56009500 855016000 1440022000 1980029000 2610050000 45000

LC.L

5

55

5%5%5%

M.O.I.TATATA9%9%9%

STANDARD LUMALUXGeneral lighting high pressure sodium..35 E-17 Med. 67500

; 6750150 E-17 Med. 67502

67503ET-23^ Mog 67510

6751170 E-17 Med. 67504

67505ET-23!^ Mog 67512

67513100 E-17 Med. 67506

67507ET-23^ Mog 67514

67515150 E-17 Med. 67508

67509ET-231/: Mog 67516

67517BT-28 Mog 67518

200 ET-18 Mog 67576250 ET-18 Mog 67578

BT-28 Mog 67521310 ET-18 Mog 67580350 T-m Mog 67613400 ET-18 Mog 67533

BT-37 Mog 67524T-7 RSC 67527

430 T-14.5 Mog 67615600 T-16 Mog 67614

67616750 BT-37 Mog 675471000 E-25 Mog 67307

LU35/MEDLU35/D/MEDLU50/MEDLU50/D/MEDLU50LU50/DLU70/MEDLU70/D/MEDLU70LU70/DLU100/MEDLU100/D/MEDLU100LU100/DLU150/MEDLU150/D/MEDLU1 50/55LU150/55/DLU150/100LU200LU250LU250/DLU310

S76ZLS76ZLS68ZLS68ZLS68NVS68IWS62ZLS62ZLS62CXS62CXS54ZLS54ZLS54CXS54CXS55ZLS55ZLS55CXS55CXS56KAS66EJS50EJS50KAS67EJ

LU350 SUPER D N/ALU400LU400/DLU400T7RSC

S51EJS51ZC

S51LU430PLANTAD S51GJLU600 SUPER S106GCLU600PLANTAD S106GCLU750LU1000

S 1 1 1 Z CS52XB

20202020202020202020202020202020202010202010201020101010101066

ClearCoated6

ClearCoated6

ClearCoated6

ClearCoated6

ClearCoated6

ClearCoated6

ClearCoated6

Clear, 55 VoltCoated, 55 Volt6

Clear, 55 Volt7

Coated, 55 Volt6-7

Clear, 100 Volt7

ClearClearCoated6

ClearClearClearCoated6

ClearClearClearClearClear14

Clear14

16000+16000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+24000+1800024000+24000+240001800018000180002400024000+

2250 20502100 19354000 36003700 34204000 36003700 34206300 53505800 49006300 55005800 49009500 80008800 75009500 80008800 750015800 1340014500 1230016000 1380014700 1250015700 1 4 1 0 022000 1980029000 2610026000 2340037000 3330046500 4400050000 4500047500 4230046000 4140051500 4240092000 8100084000 75000105000 94500130000 120700

37/63^6

3?/6

37/6

55

37/6

3?/6

55

37/6

3?/6

55

39/6

3'/6

555

53/5%5

5%5%5%15

6%6%6%6%8%

5'/6

514

5!45!4TkTA57/6

57/6

TATA57/6

5'/6

TATA5%5%TATA85/6

9%9%85A9%9M9%m10K6

m1 1 %m1 1 5 *1514

Energy Saving Product/Value Added Product I I High Color Rendering Lamp New Item Footnotes/Symbols pages 167-169

Page 2: ILUMALUXPLUST Non cycling, environmentally friendlier high ......auto-transformer; or a 240 or 277 volt reactor for the 150W, 215W, 360W lamps and a 480 volt reactor for the 880W lamp.

GUIDE TO HIGH PRESSURE SODIUM LAMPS

STEELFRAME

DOME MOUNT SUPPORT

ALUMINA ARC TUBE

WEATHER RESISTANTGLASS ENVELOPE

VACUUM

RESIDUE GAS GETTER

BRASS DATERECORDING BASE

There are currently four families of OSRAM SYLVANIA Products Inc. High 'Pressure Sodium lamps: LumaluxPlus™ Lumalux,® Lumalux® Standby andUnalux® They are one of the most efficient HID sources available. These lampsare used for general lighting applications where high efficiency and long life aredesired and color rendering is not critical. Typical applications include street-lighting, industrial hi-bay, parking lot lighting, and building floodlighting.

LUMALUX PLUS™/ECO™These environmentally friendlier lamps are designed with lead-free weldedmogul bases and they contain up to 90% less mercury than standard HPSlamps. They will NOT CYCLE at end of life. All lamps operate on existing HPSballasts for corresponding wattages. LUMALUX PLUS™ lamps pass the existingFederal TCLP limit (4/98).27

LUMALUX®Available in a broad range of mogul base general lighting lamps from 50-1000watts for universal operation. Lamps from 35 to 150 watts are also available inmedium base. Most lamps are available in clear and coated bulbs.

LUMALUX® STANDBYThese lamps are designed with two arc tubes to provide instant restrike capability in the event of a momentary power interruptionwithout total loss of light.UNALUX®These retrofit lamps are designed to operate on all mercury reactor ballasts when increased light and reduced energy is desired.

I WA™'"° I LUMALUX PLUS™, LUMALUX® AND LUMALUX® STANDBY LAMPS I »«""• I1. These lamps must be operated with a fixture and ballast which has an ANSI designation identical to the ANSI designation on the lamp etch on the outer glass bulb,otherwise the lamp may shatter resulting in the discharge of hot glass particles. SHOULD THIS OCCUR, THERE IS A RISK OF PERSONAL INJURY, PROPERTYDAMAGE, BURNS AND FIRE FROM HOT PARTICLES OR SHATTERED GLASS.2. Do not remove or insert lamps when power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled.3. Do not expose operating lamp to moisture. • I4. Replace the lamp if outer glass bulb has been scratched, cracked or damaged in any way.5. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition.Operating and Installation Instructions1. To avoid burn injury, allow lamp to cool before removing from the fixture.2. To ensure electrical contact, screw lamp firmly but not forcibly into the socket. Excessive force may cauSe the outer glass bulb to break.3. Lamps may be operated in any position.4. For maximum system performance, replace lamp at or before end of published rated life.5. Lumalux19 lamps require a specially designed base socket electrically rated to withstand 4000 volt pulses except LU750 and LU1000 which require sockets to with-stand 5000 volt pulses. - _____ _____

I **"»""= | UNALUX® LAMPS I WAHN"IG IUnalux lamps will operate satisfactorily on conventional Mercury ballast circuits meeting current ANSI specifications. Ballast must be high leakage reactance lag typeauto-transformer; or a 240 or 277 volt reactor for the 150W, 215W, 360W lamps and a 480 volt reactor for the 880W lamp. Lamps should not be used in luminarieswhich cause excessive increase in arc tube operating voltage. Do not use these lamps with constant wattage or constant wattage auto-transformer ballasts,conventional high pressure sodium ballasts or equipment not meeting conditions shown in the following table.

ApproximateMercury ANSI Unalux Lamp

Lamp Wattage Ballast Unalux Type Wattage175 (H39) ULX-150250 (H37) ULX-215400 (H33) ULX-360

1000 (H36) ULX-880

150215360880

I """""M \ SOX® LAMPS I W*""INS I1. These lamps must be operated with a fixture and ballast which has an ANSI designation identical to the ANSI designation listed on

page 84 for the corresponding wattages.

• 2. Single based SOX lamps 35W to 180W should be supported traction-relief at the end opposite to the base.

3. SOX lamps contain a small quantity of sodium. In case of lamp breakage, the sodium may develop heat when in contact with moisture. Therefore, the lamp must bestored and shipped enclosed in its original package.

4. The following procedure should be applied when disposing of burned out lamps in order to avoid damage:

A. Place lamp in a dry, high container and break it into small pieces in the open air and in a dry atmosphere. B. Fill the container with water by means of a rubber hose,the operator standing at a safe distance. C. After a few minutes, the sodium will be rendered harmless due to the effect of the water. D. Care should be taken that novarnished parts (for instance an automobile) are in the neighborhood which might be attacked by the sodium hydrate or splashes of sodium hydrate, respectively.