PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN APPROVED DATE DRAWING NO. B A C D E F G H 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 DIZON,JOHN JEROME G. ILLUMINATION AND ENGINEERING DESIGN MULTI-STOREY RESIDENTIAL BUILDING POLYTECHNIC UNIVERSITY OF THE PHILIPPINES COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS DATE AUGUST 26,2015 LEGEND P PIN LIGHT LED LED CEILING LIGHTS CEILING FAN W/ LIGHTS FLOURESCENT LAMPS LED SPOT LIGHT H HANGING LAMP GENERAL NOTES MASTERS BEDROOM HOME THEATER FAMILY GALLERY P P P P P P P P P P P P P P P LED LED LED LED LED LED P P P P P P P P P P P P P P P P P P P P P P P P P P P P P LIVING ROOM CAR PARK KITCHEN CR DINING AREA LAUNDRY LED LED LED LED LED LED LED LED P P P P P P P P P P P P P P P 1ST FLOOR LIGHTING LAYOUT 2ND FLOOR LIGHTING LAYOUT H H 1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC). THE RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. 2. MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE OF USAGE. 3. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THW" UNLESS OTHERWISE INDICATED IN THE PLAN. THE MINIMUM SIZE OF WIRE FOR POWER AND LIGHTING CIRCUIT +20(581 6+$// %( PPð $1' ,168/$7(' )25 92/76 60$//(67 5$&(:$< 6+$// %( PP 75$'(120,1$/ 6,=( 4. WIRING METHOD SHALL BE AS FOLLOWS : a. FEEDERS AND RISERS - INTERMEDIATE METALLIC CONDUIT b. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT SCH. 40 BRANCH CKT., & AUXILIARY 5. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT. 18 2.25 2.5 6 1.75 3.75 5.5 4.875 5.625 1.75 3.75 2.5 5.625 4.75 3.625 1.75 3.75 5.25 5.125 1.625 2.375 3.625 1.25 2.25 2.5 3.375 2.25
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS
DATE AUGUST 26,2015
LEGEND
P PIN LIGHT
LED LED CEILING LIGHTS
CEILING FANW/ LIGHTS
FLOURESCENT LAMPS
LED SPOT LIGHT
H HANGING LAMP
GENERAL NOTES
MASTERSBEDROOM
HOMETHEATER
FAMILYGALLERY
P
P
P
P
P
P
P P
P
P
P
P
P
P
P
LED LED
LED LED
LED
LED
P
P P PP P PP
P
PP P
PP
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
LIVINGROOM
CARPARK
KITCHEN
CR
DININGAREA
LAUNDRY
LED LEDLED LED
LED LEDLED LED
PP
P P
P
P
P
P
P
P
P
P
P
P
P
1ST FLOO
R LIG
HTIN
G LA
YO
UT
2ND
FLOO
R LIG
HTIN
G LA
YO
UT
H
H
1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC).THE RULES AND REGULATION OF THE LOCAL ENFORCINGAUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWERCOMPANY. THE ELECTRICAL WORKS SHALL BE DONE UNDER THE IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICALENGINEER.
2. MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE OF USAGE.
3. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATEDTYPE "THW" UNLESS OTHERWISE INDICATED IN THE PLAN. THEMINIMUM SIZE OF WIRE FOR POWER AND LIGHTING CIRCUITHOMERUN SHALL BE 3.5mm² AND INSULATED FOR 600 VOLTS.SMALLEST RACEWAY SHALL BE 15mmØ TRADE/NOMINAL SIZE.
4. WIRING METHOD SHALL BE AS FOLLOWS :a. FEEDERS AND RISERS - INTERMEDIATE METALLIC CONDUITb. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT SCH. 40 BRANCH CKT., & AUXILIARY
5. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT.
18
2.25
2.5
6
1.75
3.75
5.5 4.875
5.625
1.75
3.75
2.55.625
4.75
3.625
1.75
3.75
5.25 5.125
1.625
2.375
3.625
1.25
2.25
2.5
3.3752.25
SuperJhay
Rectangle
SuperJhay
Rectangle
SuperJhay
Typewritten text
1
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS
DATE AUGUST 26,2015
MULTI-STOREY RESIDENTIAL BUILDING
SuperJhay
Typewritten text
2
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS
DATE AUGUST 26,2015
LIVING ROOM
SuperJhay
Typewritten text
3
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS
DATE AUGUST 26,2015
MASTER'S BEDROOM
SuperJhay
Typewritten text
4
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS
DATE AUGUST 26,2015
BEDROOM
SuperJhay
Typewritten text
5
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS
DATE AUGUST 26,2015
KITCHEN & DINING ROOM
SuperJhay
Typewritten text
6
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS
DATE AUGUST 26,2015
HOME THEATER
SuperJhay
Typewritten text
7
PROJECT TITLE SHEET CONTENTS REVISION NOTES DESIGN / DRAWN
APPROVED
DATE
DRAWING NO.
BA C D E F G H
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
DIZON,JOHN JEROME G.
ILLUMINATION AND ENGINEERING DESIGNMULTI-STOREY RESIDENTIAL BUILDING
POLYTECHNIC UNIVERSITY OF THE PHILIPPINESCOLLEGE OF ENGINEERING
DEPARTMENT OF ELECTRICAL ENGINEERING ILLUMINATION DESIGN OF DIFFERENT ROOMS