1 IHE Workshop – February 2007 What IHE Delivers Marco Eichelberg Marco Eichelberg IHE-D Technical Manager IHE-D Technical Manager NM Image NM Image
27

IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

Jan 05, 2016

Download

Documents

Deborah Turner
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

1IHE Workshop – February 2007 What IHE Delivers

Marco EichelbergMarco Eichelberg

IHE-D Technical ManagerIHE-D Technical Manager

NM ImageNM Image

Page 2: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

2IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

NM ImageNM Image The ProblemThe Problem

DICOM NM objects are different and support in products is inconsistent

NM cardiac display needs are different and support in products is inconsistent

Clinical Analysis Programs are used extensively (particularly for Cardiology), but no support for distribution and display of those Result Screens

NM Users are not adept at getting these requirements accurately included in RFPs

Vendors (especially of general purpose systems) are not adept at accurately representing their support for such features

Page 3: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

3IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

General NM Viewing SuboptimalGeneral NM Viewing Suboptimal

NM PACS

Page 4: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

4IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

General NM Viewing SuboptimalGeneral NM Viewing Suboptimal

NM PACS

Page 5: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

5IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

General NM Viewing SuboptimalGeneral NM Viewing Suboptimal

Click and move mouse down to adjust window level, right to adjust window center

Page 6: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

6IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Cardiac Viewing SuboptimalCardiac Viewing Suboptimal

If sent as Short axis Images not

displayed in a useful format.

If sent as screen snapshots(ie, static Secondary Capture) Can’t separately adjust stress and rest images Can’t view gated cine

Page 7: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

7IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

New in 2006 !New in 2006 !

Cardiac Option Better addresses cardiac needs

Minor restructuring of remaining profile General NM option MPR option

(Review option retired) (Comparison display eliminated)

Page 8: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

8IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

NM Image NM Image Abstract / ScopeAbstract / Scope

Content Profile for Users to request and Vendors to claim

No New Actors or Transactions Additional requirements on existing actors and transactions Total of 4 options

New Informative Text in Vol. 1 Clarifications of NM Workflow mapping to SWF Explanation of NM Data Explanations of NM Clinical Display concepts

New Normative Text in Vol. 2 < See Following Slides >

Page 9: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

9IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

NM ImageNM ImageValue PropositionValue Proposition

Use general Radiology Infrastructure to:

Satisfy Basic NM Data Needs Access to NM Images Access to usable presentations of NM Images Access to Clinical Processing Results

Satisfy NM Workflow Needs Map Cardiac and Multi-phase Studies to SWF Improved Query

Page 10: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

10IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

NM ImageNM ImageTransaction DiagramTransaction Diagram

Page 11: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

11IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

NM ImageNM ImageStandards UsedStandards Used

DICOM NM Image Object

DICOM Multiframe Secondary Capture Dynamic Results Collection of Static Results

DICOM Secondary Capture Static Results

ACC NM Cardiac Display format

Page 12: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

12IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

NM Image ActorsNM Image ActorsAcquisition Modalities Create NM objects as specified (Series, attribute & vector handling) Include specific codes in Cardiac studies

Evidence Creators Create NM objects as specified (Series, attribute & vector handling) Include specific codes in Cardiac studies

Image Manager/Archives Store/Retrieve NM & Secondary Capture (SC & MFSC) Objects Support Query on Study Description

Image Displays Display NM and Secondary Capture (SC & MFSC) Images Support specified display capabilities

Page 13: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

13IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Image DisplayImage Display

Display NM and Result-Screen Images

Support specified NM essential display capabilities

Additional attribute handling e.g. Patient State, Image Orientation, Detector Sequence, View

Code Sequence

Page 14: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

14IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Options: Image DisplaysOptions: Image Displays

General NM Option Whole body display

Cardiac NM Option ACC NM Cardiac display

Displays must support at least one of these options!

Page 15: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

15IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Handle multi-frame / multi-vector images

Multiple simultaneous cines

Grayscale and color result screens

Dynamic and static result screens

Original resolution and scaled

Separate adjustment of upper and lower window levels

Apply local color tables to grayscale screens

Add new local color tables to system

Change intensity of grayscale result screens

Display Series Description tag

Image DisplayImage Display

Page 16: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

16IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

NM Image FormatNM Image Format

Understood by dedicated NM systems

Often Misunderstood by general storage and display systems

Multiframe Dynamic

Anterior Posterior Multi-energy

NM Image

Image vectors

Page 17: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

17IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Image DisplayImage Display

Scale “intelligently” to avoid presenting postage-stamp size NM images

Allow user to select different vectors/framesets of complex multi-frame images

Allow user to separately adjust intensity for different framesets (eg, phases) in the same “image”

Page 18: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

18IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Display FormatsDisplay Formats

Grid display Frames from one

image set

A32

…………………

……………………

…………………A9

A8 A7 A6A5 A4 A3 A2 A1

C1 C1

B2B1 A2 A1 Fit display Frames from multiple image

sets

Page 19: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

19IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

ACC NM Cardiac DisplayACC NM Cardiac Display

Generate long axis from short axis images

Display of 2 image sets (Stress and Rest)

Use patient state tags to set display order

Follow ACC guidelines for display

Controls for adjusting stress and rest Image alignment Window upper and lower levels.

Page 20: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

20IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

ACC NM Display ExampleACC NM Display ExampleShort axis

Horizontal Long

Vertical Long

Page 21: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

21IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

ACC NM Display ExampleACC NM Display ExampleShort

Horizontal

Vertical

Stress

Rest

Stress

Rest

Stress

Rest

Stress

Rest

Page 22: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

22IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Another ACC Display ExampleAnother ACC Display Example

Different Layout

Same stress and rest views

Page 23: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

23IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

MPR Option: Image DisplaysMPR Option: Image Displays

Adds Image Display requirements to support Review of SPECT NM Images with Multi-planar reconstruction (MPR) Transaxial Sagittal Coronal

Page 24: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

24IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Result Screen Export OptionResult Screen Export Option

Page 25: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

25IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Result Screen Export Option:Result Screen Export Option:Evidence CreatorsEvidence Creators

Render Dynamic Result Screens Based on the following DICOM Objects:

• Multi-Frame Grayscale Byte Secondary Capture• Multi-Frame True Color Secondary Capture

Creating multiple single frame objects is NOT sufficient.Render Static Result Screens Using single frame DICOM Secondary Captures is sufficient Using Multi-frame to render single or several related static result

screens is recommended• provides better image comment/label attributes• provides implicit display order• displayed by stepping, not cine

Must generate appropriate Secondary Capture objects from any Result Screens created.

Page 26: IHE Workshop – February 2007What IHE Delivers 1 Marco Eichelberg IHE-D Technical Manager NM Image.

26IHE Workshop – Feb. 2007IHE Workshop – Feb. 2007

Points of Interest - NMPoints of Interest - NM

Appendix E, Volume 1 (Informative) New to Nuclear Medicine? Trouble matching NM to Scheduled Workflow? Start Here.

E.2 NM Workflow – What happens in NM procedures E.3 NM Worklists – How to schedule/model it E.4 NM Data – What to expect in the DICOM E.5 NM Display – How it should be presented

Many subtleties here