Top Banner
ECOCLEAN AIR the most efficient malodour absorber by
12

Igl ecoclean air

Jan 18, 2017

Download

Technology

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Igl ecoclean air

ECOCLEAN AIRthe most efficient malodour absorberby

Page 2: Igl ecoclean air

2

ü fastestü longest lastingü only non-reversible

malodour absorber technology in the market

ECOCLEAN AIR IS THE

Page 3: Igl ecoclean air

3

ADDITIONAL BENEFITS

Ecoclean Air remove odours like

ü cigarette smokeü sweatü garbageü pet smellü onions and garlic

Page 4: Igl ecoclean air

4

removes malodours by permanent chemical bonding

ECOCLEAN AIR MODE OF ACTION

Page 5: Igl ecoclean air

5

ü textile & carpet refresherü bins and toilet sanitizersü pet careü cat litterü disinfecting

PRODUCT USE GUIDELINE

Page 6: Igl ecoclean air

66

DETERMINATION OF MALODORS

Reduction of•Ammonia•Isovaleric acid•Dimethylsulfide

Test Malodor Analytical Method

Ammonia Olfactory Panel Test

Isovaleric acid GasChromatography

Waste AirThreshold of Smell: <55000 ppb

Body OdorThreshold of Smell : <25 ppb

Simulation of

Dimethylsulfide SolidPhaseMicroExtractionKitchen Odor

Threshold of Smell : <200 ppb

Page 7: Igl ecoclean air

7

Elimination of Isovaleric Acid

EFFICIENCY OF ECOCLEAN AIR

0

200

400

600

800

1.000Isovaleric acid (µl )

Available conc: 200µl 250µl 300µl 350µl 800µl

eliminated

• Seal 50 ml of ecoclean air in a 1 litre flask with a septum.

• Heat up to 60 °C and add Isovaleric acid with a syringe.• Measure the concentration of isovaleric acid in vapour phase by GC 24

hours after addition.

• At the final stage: Detection of isovaleric acid traces after 24 hours

Page 8: Igl ecoclean air

6

SPME – MALADORS DETERMINATION EQUIPMENTSolidPhaseMicroExtraction with Autosampling and GC Detection

Page 9: Igl ecoclean air

SPME – MALADOR DETERMINATION METHOD

7

Ø 1ml sample is added into test flask

Ø Close the test flask with a septum on top

Ø Add 1 µl of DMF containing 0.2 to 40 µg DMS

Ø Shake the test flask for 10 Min.

Ø Sample with special modified fibre

Ø Place in GC-Detection

Ø Detect and compare the DMS-Peaks

Adsorption - Sampling Desorption - Detection

Page 10: Igl ecoclean air

8

COMPARISON SPME-EFFICIENCY

Water (control)

Ecoclean Air

Levels of DMS concentrations absorbed by different absorber systems

0 2 µg 4 µg 6 µg 8 µg 10 µg 12 µg 14 µg 16 µg 18 µg 20 µg DMS

Cyclodextrine

Uptake of Malodor compared to water

Page 11: Igl ecoclean air

9

AVOID PAIN AND CLOTHES PINS

It's your choice -

Ecoclean Air or clothes pins!

Page 12: Igl ecoclean air

10

THANK YOU