PIPING SYMBOLS MECHANICAL SYMBOLS: SINGLE LINE DUCTWORK SYMBOLS DOUBLE LINE MECHANICAL ABBREVIATIONS: GENERAL NOTES: DELIVERY, STORAGE, AND HANDLING WELDING DIFFUSER SYMBOLS CONTROL SYMBOLS PIPING CONT'D. 140 Park Avenue New City, NY 10956 Tel 845-708-9200 www.shilale.com IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO FULL SCALE 1/2 1 0 335 WESTERN HIGHWAY TAPPAN, NY 10983 TOWN OF ORANGETOWN COUNTY OF ROCKLAND HOMES FOR HEROES 3062 ROUTE 9W, SUITE 500 NEW WINDSOR, NY 12553 TEL: 845-562-7005 FAX: 845-562-7007 M-001 NOTES & SYMBOLS
11
Embed
IF THIS BAR DOES NOTMEASURE 1 THEN DRAWING · PDF filemechanical abbreviations: general notes: delivery, storage, and handling welding diffuser symbols piping cont'd. control symbols
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
PIPING SYMBOLS
MECHANICAL SYMBOLS:
SINGLE LINEDUCTWORK SYMBOLS
DOUBLE LINE
MECHANICAL ABBREVIATIONS: GENERAL NOTES:
DELIVERY, STORAGE, AND HANDLING
WELDING
DIFFUSER SYMBOLS
CONTROL SYMBOLSPIPING CONT'D.
140
Par
k A
venu
e
N
ew C
ity, N
Y 1
0956
T
el 8
45-7
08-9
200
ww
w.s
hila
le.c
om
IF THIS BAR DOES NOT
MEASURE 1" THEN DRAWING IS
NOT TO FULL SCALE
1/2
10
335 WESTERN HIGHWAY
TAPPAN, NY 10983
TOWN OF ORANGETOWN
COUNTY OF ROCKLAND
HOMES FOR HEROES
3062 ROUTE 9W, SUITE 500
NEW WINDSOR, NY 12553
TEL: 845-562-7005
FAX: 845-562-7007
M-0
01
NO
TE
S &
SY
MB
OLS
CIRCULAR BRANCH CONNECTON TO SINGLE OUTLET
ROUND DUCT HANGERS
PIPE PENETRATION THROUGH ROOF DETAIL
PIPE HANGER DETAIL
TOILET EXHAUST ROOF CURB/HOOD DETAIL
FAN COIL UNIT SCHEDULE
AIR-COOLED CONDENSING UNIT SCHEDULE
DIFFUSER, GRILLE AND REGISTER SCHEDULE (ANEMOSTAT AS STD.)DESIGNATION CFM SERVICE NECK SIZE (IN.)/ NOMINAL FACE TYP. BRANCH REMARKS
NO. OF SLOTS SIZE - W x L (IN.) DUCT SIZECD-A 0-175 SUPPLY 6 24X24 12x4 EPLCD-B 176-350 SUPPLY 8 24X24 14x6 EPLCD-C 351-450 SUPPLY 10 24X24 16x6 EPLCD-D 451-650 SUPPLY 12 24X24 16x8 EPL
CG-A 0-1100 RET / EXH - 24X24 - XAC35LD W/ LIGHT SHIELD PAINTED BLACKCG-B 0-1100 RET / EXH - 24X24 - X3HD-81-L FILTER GRILLECG-C 151-270 RET / EXH 10X10 10X10 12x4 X35H-D W/ LIGHT SHIELD PAINTED BLACK
NOTES:1. SEE HVAC FLOOR PLAN FOR CFM'S.2. COORDINATE BORDER AND FRAME TYPES WITH ARCHITECTUAL CEILING DETAILS.3. PROVIDE VOLUME DAMPERS AT ALL BRANCH OUTLETS.4. PROVIDE ALL DIFFUSERS WITH FLOW EQUALIZING DEFLECTORS.5. PROVIDE ALL DIFFUSERS AND REQISTERS WITH OPPOSED BLADE DAMPERS.6. ALL DIFFUSERS, GRILLES AND REGISTERS TO HAVE MANUFACTURERS STANDARD WHITE BAKED-ON FINISH.
TR - SUPPLY SEE DWGS S20V WITH OPPOSED BLADE DAMPERSSEE DWGS SEE DWGS