IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification System for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ITA 12.0014X Status: Current Date of Issue: 2020-04-21 Applicant: CCG Cable Terminations Pty Ltd 33-37 Forge Road, Spartan Ind Area Kempton Park 1619 South Africa Equipment: Range of cable glands for armoured and non-armoured cables Optional accessory: Type of Protection: d, t, nR, e Marking: Page 1 of 4 Issue No: 5 Certificate history: Issue 4 (2017-07-26) Issue 3 (2016-09-06) Issue 2 (2015-12-22) Issue 1 (2013-07-04) Issue 0 (2012-12-20) Ex d I Mb/Ex d IIC Gb, Ex e I Mb/Ex e IIC Gb, Ex nR IIC Gc, Ex tb III C Db (as applicable) IP66/67/68 (2m), IP65 (As applicable) See Attachment. 1. 2. 3. Approved for issue on behalf of the IECEx Certification Body: Position: Signature: (for printed version) Date: This certificate and schedule may only be reproduced in full. This certificate is not transferable and remains the property of the issuing body. The Status and authenticity of this certificate may be verified by visiting www.iecex.com or use of this QR Code. Certificate issued by: Ex Testing and Certification Pty Ltd 1/30 Kennington Drive Tomago NSW 2322 Australia Ajay Maira Certification Authority 2020-04-21
22
Embed
IECEx Certificate of Conformity...of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification System for Explosive Atmospheres for rules and details of the IECEx Scheme
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
IECEx Certificateof Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSIONIEC Certification System for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Certificate No.: IECEx ITA 12.0014X
Status: Current
Date of Issue: 2020-04-21
Applicant: CCG Cable Terminations Pty Ltd33-37 Forge Road, Spartan Ind Area Kempton Park 1619 South Africa
Equipment: Range of cable glands for armoured and non-armoured cables
Approved for issue on behalf of the IECEx Certification Body:
Position:
Signature:(for printed version)
Date:
This certificate and schedule may only be reproduced in full.This certificate is not transferable and remains the property of the issuing body.The Status and authenticity of this certificate may be verified by visiting www.iecex.com or use of this QR Code.
Certificate issued by:
Ex Testing and Certification Pty Ltd1/30 Kennington Drive Tomago NSW 2322 Australia
Ajay Maira
Certification Authority
2020-04-21
IECEx Certificateof Conformity
Certificate No.: IECEx ITA 12.0014X
Date of issue: 2020-04-21
Page 2 of 4
Issue No: 5
Manufacturer: CCG Cable Terminations Pty Ltd33-37 Forge Road Spartan Ind Area Kempton Park 1619 South Africa
Additional manufacturing locations:
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements.This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended
STANDARDS :The equipment and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards
IEC 60079-0:2011 Edition:6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1:2007-04 Edition:6
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-15:2010 Edition:4
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-31:2013 Edition:2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
IEC 60079-7:2006-07 Edition:4
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
This Certificate does not indicate compliance with safety and performance requirements other than those expressly included in the Standards listed above.
TEST & ASSESSMENT REPORTS:A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in:
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above)
Annex:
IECEx ITA 12.0014X-5 - Certificate Annex final.pdf
Please refer to attached Annex.
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 7 of 18
Specific Conditions of Use pertaining to all issues of this Certificate:
� Instructions according to clause 30 of IEC 60079-0 and a copy of the Certificate must be provided / made available with the equipment. In addition, the installation torque and applicable maximum / minimum cable diameters must be made available / included in the instructions to the end user.
� When the quick stop glands are supplied with the metal sleeve and cementing it must be fitted with the metal sleeve and cementing since the internal gland construction only accommodates the large diameter of the metal sleeve for clamping
� For the Stopex glands the barrier putty must be finished off to be fully formed within the cone and smooth along the full length of the cone since it forms a flamepath with the cone.
� The cable glands shall only be used where the temperature, at the point of entry, is between -20°C and + 95°C, -50°C to 120°C or -60°C to 160°C depending on non-metallic materials used (See Description Table�2�row�‘Service�Temperature).
� Only the compounds as supplied by the manufacturer may be used in the glands.
� Cable glands for unarmoured cable and approved only for group IIC (Not group I) may only be used on fixed installations where the cable is clamped or stress applied to the cable in the gland is prevented.
� The appropriate ingress protection level / restricted breathing and / or flameproof characteristics must be achieved and maintained at the interface of the gland with the enclosure.
� An IP rating of IP66/67/68 is maintained for units with parallel threads when used with the supplied washer and for units with tapered thread when thread sealing is conducted as indicated in IEC60079-14. Alternatively an IP65 rating is applicable.
Additional conditions applicable to specific glands:
� A2EX-FHC / VRTX: The cable glands may only be used on fixed installations where the cable is clamped or stress applied to the cable in the gland is prevented.
� Armortex and E1EX-U: The Armortex and E1EX-U glands have been tested for braided cable for group II and III only. When braided cable is fitted it may only be used on fixed installations where the cable is clamped or stress applied to the cable in the gland is prevented.
� Posigrip: The gland may only be installed / dismantled using the tool provided by CCG.
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 8 of 18
Drawing list pertaining to Issue 0 of this Certificate:
Manufacturer’s�Documents
Part Drawing Number Title Edition Date
A2EX (QS)
Assembly 0537 - ASSY No."X" A2EX CABLE GLAND Original 2012/08/21
Cone 0537 - C No."X" A2EX & POSI GRIP CONE Original 2012/08/21
Gripper Seal 0537 - GS No."X" A2 GRIPPER SEAL Original 2012/08/21
NPT Assembly 0537 - NPT -ASSY
No."X" A2EX CABLE GLAND - NPT Original 2012/08/21
Outer 0537 - O No."X" A2EX OUTER Original 2012/08/21
Skid Ring 0537 - SR No. "X" A2 SKID RING Original 2012/08/21
Material 0537 - MATL No."X" A2EX Ex de CABLE GLAND Original 2012/08/21
A2F (QS)
Assembly 0541 - ASSY No. "X" A2F GLAND Original 2012/08/22
Inner 0541 - I No."X" A2F INNER Original 2012/08/22
Material 0541 - MATL No. "X" A2F GLAND MATERIAL Original 2012/08/22
NPT Assembly 0541 - NPT -ASSY
No. "X" A2F NPT CABLE GLAND Original 2012/08/22
Outer 0541 - O No. "X" A2F OUTER Original 2012/08/22
Inner NPT 0541 - NPT - I No."X" A2F INNER NPT Original 2012/08/22
Marking 0541- MARK No. "X" A2F GLAND MARKING Original 2012/09/21
A2F CG (QS)
Assembly 0543 - ASSY No."X" A2F CORROSION GUARD Original 2012/08/22
Outer 0543 - CG - O No "M" A2F CORROSION GUARD OUTER
Original 2012/09/19
Material 0543 - MATL No."X" A2F CORROSION GUARD Original 2012/08/22
A2FH (QS)
Hose Tail 0549 - HT No. "X" A2FH OUTER - HOSE TAIL Original 2012/08/22
Material 0549 - MATL No."X" A2FH GLAND MATERIALS Original 2012/08/22
Assembly 0549 - ASSY No. "X" A2FH GLAND Original 2012/08/22
NPT Assembly 0549 - NPT -ASSY
No. "X" A2FH GLAND ASSEMBLY - NPT Original 2012/08/22
A2FX (QS)
Assembly 0542-ASSY No. " X" A2FX GLAND Original 2012/08/22
Material 0542-MATL No."X" A2FX GLAND MATERIALS Original 2012/08/22
NPT Assembly 0542 - NPT-ASSY
No. " X" A2FX GLAND Original 2012/08/22
Outer 0542 - O No."X" A2FX OUTER Original 2012/08/22
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 9 of 18
D1EX (QS)
- 0519 -W No."X" D1EX, A2EX E1EX WASHER Cancelled
Assembly 0519 -ASSY No."X" D1EX Ex de CABLE GLANDS Original 2012/08/22
Materila 0519 - MATL No."X" D1EX Ex de CABLE GLANDS Original 2012/08/23
NPT Assembly 0519 - NPT -ASSY
No. "X" D1EX Ex de CABLE GLANDS -NPT
Original 2012/08/23
Outer 0519 - O No."X" D1EX OUTER Original 2012/08/23
E1EX (VS)(LS)(QS)
Assembly 0523 - ASSY No."X" E1EX Ex de CABLE GLANDS Original 2012/08/21
Body 0523-B No."X" E1EX, EXCG, STOPEX & STOPEX CG BODY
Original 2012/08/21
Cone 0523 - C No."X" EIEX, D1EX & EXCG CONE Original 2012/08/21
Cone Ring 0523 - CR No."X" E1EX, D1EX, EXCG, STOPEX & STOPEX CG CONE RING
Original 2012/08/21
Inner 0523 - I No."X" EIEX,A2EX, D1EX & EXCG INNER
Original 2012/08/21
Inner / Displacement Seal
0523 - IS No"X" E1EX,A2EX,EXCG & D1EX INNER/DISPLACEMENT SEAL
Original 2012/08/21
Marking 0523 - MARK No."X" EX GLAND MARKING Original 2012/08/21
Material 0523 - MATL E1EX Ex de CABLE GLANDS Original 2012/08/21
Outer Nut 0523 - ON No."X" E1EX OUTER NUT Original 2012/08/21
Outer Seal 0523 - OS No "X" E1EX OUTER SEAL Original 2012/08/21
Skid Ring 0523 - SR No "X" E1EX & EXCG SKID RING Original 2012/08/21
EXCG (VS)(LS)(QS)
Assembly 0547 - ASSY No. "X" Ex de CORROSION GUARD Original 2012/08/22Material 0547 - MATL No. "X" EXCG de GLAND MATERIAL Original 2012/08/22Outer Seal 0547 - OS No "X" EXCG OUTER SEAL Original 2012/08/22Body Components 0547 -BODY-
ASSYNo."X" EXCG BODY COMPONENTS Original 2012/08/22
Sealing Gasket 0547 - CGSG No�“X”�EXCG�SEALING�GASKET Original 2012/08/22
STOPEX
Marking 0515 - MARK No."X" STOPEX GLAND MARKING Original 2012/09/21NPT Assembly 0515 - NPT -
ASSYNo."X" STOPEX NPT GLAND ASSEMBLY
Original 2012/08/23
Assembly 0515 - ASSY No."X" STOPEX GLAND ASSEMBLY Original 2012/08/23NPT Inner 0515 -I- NPT No."X" STOPEX NPT INNER Original 2012/08/23Cone 0515 - C No."X" STOPEX CONE Original 2012/08/23Inner 0515 - I No."X" STOPEX INNER Original 2012/08/23Material 0515 - MATL No."X" STOPEX GLAND MATERIAL Original 2012/08/23Assembly 0516-CG- ASSY No."X" STOPEX - CG GLAND
ASSEMBLYOriginal 2012/08/23
Material 0516-MATL - CG No."X" STOPEX - CG GLAND MATERIAL
Original 2012/08/23
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 10 of 18
STOPEX- F
Assembly 0550- ASSY No."X" STOPEX- F Original 2012/08/22Cone 0550 - C No."X" STOPEX- F- CONE Original 2012/08/22Material 0550 - MATL No. "X" STOPEX - F - MATERIAL Original 2012/08/22NPT Assembly 0550- NPT -
ASSYNo."X" STOPEX- F - NPT Original 2012/08/22
Outer 0550 - O No."X" STOPEX- F- OUTER Original 2012/08/22
GENERALQuick Stop Sleeve Assembly
0523-ASSY-SL TYPICAL QUICK STOP WITH SLEEVE ASSEMBLY
Original 2012/09/09
Sealing Gasket 8055-SG No�“X”�CCG�SEALING GASKET Original 2012/09/14
Variations permitted by Issue 1 of this certificate:
The body of the Stopex and E1Ex series of glands is optionally extended to allow better seal of the rear IP seal on the external sheath of the armoured cable.
Specific Conditions of Use pertaining to Issue 1 of this certificate:
- These have been amalgamated and provided in ‘Specific Conditions of Use pertaining to all issues of this�Certificate’.
Drawings Associated with the Issue 1 of this Certificate:
No."X" E1EX Ex de CABLE GLANDS 0523 - ASSY - 1 2013-06-19
No."X" E1EX, EXCG, STOPEX & STOPEX CG BODY 0523 - B - 1 2013-06-19
No."X" E1EX Ex de CABLE GLANDS - NPT 0523 - NPT - ASSYSheet 1 of 3
- 1 2013-06-19
Variations permitted by Issue 2 of this certificate:
- Optional seals (Silicone) / gaskets (PTFE) are used for higher service temperature.- Additional series of glands were added as per description (Shown in Italics in the tables 1 and 2). - Other changes also indicated in the description (Shown in Italics in the tables 1 and 2)).- Special conditions of use were updated.- The original conditions of certification / manufacture were removed based on the instructions format
being submitted and included as part of the certification documents.
Specific Conditions of Use pertaining to Issue 2 of this certificate:
- These have been amalgamated and provided in ‘Specific Conditions of Use pertaining to all issues of this�Certificate’.
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 11 of 18
Drawings Associated with the Issue 2 of this Certificate:
Manufacturer’s�Documents
Part Drawing Number
Title Edition Date
E1EX (VS)(LS)(QS)
Assembly 0523 - ASSY No."X" E1EX Ex de CABLE GLANDS 1 2015-03-02
Assembly 0549 - ASSY No. "X" A2FH GLAND 1 2015-02-27
Outer - Hose Tail 0549 - HT No. "X" A2FH OUTER -
HOSE TAIL
1 2014-11-14
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 15 of 18
A2EX (QS)
Assembly 0537-ASSY No " X" A2EX ASSEMBLY 2 2015-09-10
Outer 0537 - O No."X" A2EX OUTER 6 2015-09-10
Cone 0537 – C No."X" A2EX & POSI GRIP
CONE
3 2015-09-10
A2EX-FHC (QS)
Assembly 0537 - ASSY No. " X" A2EX FHC GLAND
ASSEMBLY
1 2015-02-27
Marking 0537 – MARK REV 1
A2EX-FHC GLAND MARKING 1 2015-05-05
Outer 0537 - O No. "X" A2EX- FHC OUTER Original 2013-05-09
Coupling 0537 - CO No. "X" A2EX FHC
COUPLING
Original 2014-05-15
Outer Coupling 0537 - OC No."X" A2EX FHC OUTER
COUPLING
Original 2013-05-15
VRTX
Assembly 0531-VRTX No."X" VRTX GLAND
ASSEMBLY
1 2015-03-02
Inner 0531-I No."X" VRTX INNER 1 2011-01-03
Body 0531- B No."X" VRTX BODY Original 2009-09-23
Compression Nut 0531-CN No."X" VRTX COMPRESSION
NUT
1 2011-01-03
Outer Nut 0531-ON No."X" OUTER NUT Original 2009-08-28
Skid Ring 0531-SR No."X" SKID RING Original 2009-09-11
Outer Seal 0531-OS No."X" OUTER SEAL Original 2009-09-11
Sealing Gasket 0531- SG No."X" SEALING GASKET Original 2009-09-14
Marking 0531-MARKING
No.”X”�VRTX�GLAND�MARKING 1 2015-05-05
STOPEX-F
Assembly 0550- ASSY No."X" STOPEX- F 1 2015-03-02
Cone 0550-C No."X" STOPEX- F- CONE 1 2014-11-23
Outer 0550 - O No."X" STOPEX- F- OUTER Original 2012-08-22
A2FX-R (QS)
Assembly 0577- ASSY No. "X" A2FX-R ASSY 2 2015-09-10
Inner 0577-I No."X" A2FX-R INNER 1 2015-09-10
Body 0577-B No."X" A2FX- R BODY 1 2015-09-10
Outer 0577-O-R No."X" A2FX-R OUTER 1 2015-09-10
Marking 0577-MARKING
No.”X”�A2FX-R MARKING Original 2015-04-29
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 16 of 18
Variations permitted by Issue 3 of this certificate:
1. Table 1 from previous revision split into two tables.2. Table 1: Gland A2FCG (QS) NPT thread type was removed.3. Table 3:�The�Model�number�of�multiple�gland�types�was�corrected�to�show�“(QS)”�on�applicable�
by�“0536�- ASSY”,�“0536�- O”�and�“0536 - C”�respectively.10. Quick�stop�note�added�to�the�Posi�Grip�assembly�drawing�“0545�– ASSY”.11. The description has been updated to reflect the changes. All changes in Tables 1,2 and 3 are
indicated in italic font.12. Added an option for the use of copper foil sheathed (VS) armoured cable with the E1EX, E1EX-U
and EXCG glands.13. Added an option for the use of lead sheathed (LS) armoured cable with the E1EX, E1EX-U and
EXCG glands.14. Glands CWe and CXe have been added to the range.15. Additional special condition of use regarding the Armortex and E1EX-U glands have been updated to
include the CXe gland.16. The�maximum�armour�diameter�(dimension�‘F’)�for�the�glands�D1EX,�E1EX,�E1EX-LS, E1EX-U and
EXCG has been increased from 3.5mm to 4mm for the gland size 10-100.17. An additional condition of use has been added relating to the use of washers for parallel threads and
thread sealant for NPT threads for achieving IP66/67/68 (2m)18. Manufacturing drawing tables throughout this annex have been updated to fix minor editorial issues
Specific Conditions of Use pertaining to Issue 3 of this certificate:
The specific condition of use has been added:� An IP rating of IP66/67/68 is maintained for units with parallel threads when used with the supplied
washer and for units with tapered thread when thread sealing is conducted as indicated in IEC60079-14. Alternatively an IP65 rating is applicable.
The specific condition of use regarding the Armortex and E1EX-U has been updated to:� Armortex, E1EX-U and CXe:
o The Armortex, E1EX-U and CXe glands have been tested for braided cable for Group II and III only. When braided cable is fitted it may only be used on fixed installations where the cable is clamped or stress applied to the cable in the gland is prevented.
Drawings Associated with the Issue 3 of this Certificate:
Manufacturer’s�Documents
Part Drawing Number
Title Edition Date
A2F (QS)
Marking 0541 - MARK No.�“X”�A2F�GLAND�MARKING 4 2016-06-30
IECEx Certificate of Conformity
Annex
Annexe for Certificate No.: IECEx ITA 12.0014X Issue No.: 5
This form is identified as QMA-HAE-08-710 Issued 2019-03-15 Page 17 of 18
Part Drawing Number
Title Edition Date
Gripper Seal 0536 - GS No."X" A2 GRIPPER SEAL 6 2016-05-20
Skid Ring 0536 - SR No. "X" A2 SKID RING 6 2016-05-20
A2X-R (QS)
Marking 0577-MARKING
No.�“X”�A2FX-R MARKING 1 2016-06-30
A2EX (QS)
Assembly 0536-ASSY No " X" A2EX ASSEMBLY 3 2016-05-20