iConnect Car Wash Remote Data Acquisition System
Jan 13, 2016
iConnect
Car Wash Remote Data Acquisition System
iConnect
Data Acquisition System
Remote Control
Remote Diagnostics
Reporting and Tracking
Variable Wash Speed
Email and Text Messaging
by
“I Need Current Up To Date Car Wash Data!”
• For years car wash operators have dreamed of having current
up to date information on their car washes
• The need is even stronger for multiple site car wash operators
• Managing a car wash program with information months old
or even non-existent is very frustrating for managers
Car Wash Information
• Information is needed to:• Manage car washes
• Make replacement decisions
• Monitor promotional results
• Monitor and manage uptime and reliability
• Deliver better customer satisfaction• Increase revenues
• Deliver more bottom line profits
iConnectCar Wash Remote Data Acquisition System
RYKO Has A Solution!
The Solution
• Every day RYKO iConnect equipped car washes transmit data via the internet
• Information is received and compiled in a secure software application
• Reports are generated
• Data can be exported into Excel for custom reports
• Information is current from the day before
• Up to 25,000 car wash sites
How Does it Work?
• Each day the RYKO CAW automatically sends data to the receiving computer/server
• Connection:• Ethernet or• GSM
How Does it Work (Cont.)
• Receiving computer or server:
• Stores cumulative data from the CAW
• Back-up is provided in SQL server
• Calls are scheduled from the CAW• Remote computer creates the
schedule
• Call or transmission takes only a few seconds
How Does it Work (Cont.)
• Remote computer receives the information and compiles the reports
• Reports may be forwarded on to other computers
Ryko Designed Reports
The Data!
• Total washes counts at all sites
• Total carwash cash sales from all sites
• Diagnostic codes and times from all sites
• Total gross sales of all sites• Total refunds given at all
sites• Total rewashes (free
washes) done at all sites
• Total net revenue for the time period for all sites
• POS Sales• Fleet Account Sales• Total vacuum sales from all
sites• Total vacuum cycles done
at all sites• Total vending machine
sales from all sites• Total taxes collected for all
sites (if applicable)
RYKO’s Remote Data Acquisition system:
Export Data
• Data may be exported to Excel
• Custom sorting of information
• Custom reports
Excel Steps to Access Data
1
2
3
Revenue Date Item Name Description Quantity
6/20/2005 0:00 1 PLATINUM CAW Key 1 11 556/20/2005 0:00 2 GOLD CAW Key 2 4 166/20/2005 0:00 3 SILVER CAW Key 3 7 216/20/2005 0:00 4 BRONZE CAW Key 4 3 66/21/2005 0:00 1 PLATINUM CAW Key 1 16 806/21/2005 0:00 2 GOLD CAW Key 2 17 686/21/2005 0:00 3 SILVER CAW Key 3 11 336/21/2005 0:00 4 BRONZE CAW Key 4 13 266/22/2005 0:00 1 PLATINUM CAW Key 1 18 906/22/2005 0:00 2 GOLD CAW Key 2 26 1046/22/2005 0:00 3 SILVER CAW Key 3 21 636/22/2005 0:00 4 BRONZE CAW Key 4 11 226/23/2005 0:00 1 PLATINUM CAW Key 1 28 1406/23/2005 0:00 2 GOLD CAW Key 2 23 926/23/2005 0:00 3 SILVER CAW Key 3 18 546/23/2005 0:00 4 BRONZE CAW Key 4 16 32
£
Fault History Code Date Description DeviceNumber Duration EndDT Id SiteId StartDT
33 6/27/2005 0:00 Machine Not at Home 1 0:03:53 6/27/2005 11:29 33 3 6/27/2005 11:2621 6/27/2005 0:00 Bay Switch on Unexpected 1 0:03:35 6/27/2005 11:33 34 3 6/27/2005 11:2933 6/27/2005 0:00 Machine Not at Home 1 15:27:07 6/28/2005 3:00 35 3 6/27/2005 11:33
255 6/28/2005 0:00 Carwash OK 1 0:07:32 6/28/2005 8:50 36 3 6/28/2005 8:4281 6/28/2005 0:00 Back-Up Air Switch/Photoeye Problem 1 6:05:37 6/28/2005 14:55 37 3 6/28/2005 8:5012 6/28/2005 0:00 Measurment / Tire Locator Photoeye 1 0:02:12 6/28/2005 14:58 38 3 6/28/2005 14:5581 6/28/2005 0:00 Back-Up Air Switch/Photoeye Problem 1 3:58:06 6/28/2005 18:56 39 3 6/28/2005 14:5812 6/28/2005 0:00 Measurment / Tire Locator Photoeye 1 0:02:21 6/28/2005 18:58 40 3 6/28/2005 18:564 6/28/2005 0:00 Circuit Protector Tripped, Main 1 8:02:31 6/29/2005 3:01 41 3 6/28/2005 18:58
33 6/29/2005 0:00 Machine Not at Home 1 0:08:16 6/29/2005 7:22 42 3 6/29/2005 7:14255 6/29/2005 0:00 Carwash OK 1 0:09:49 6/29/2005 7:32 43 3 6/29/2005 7:2240 6/29/2005 0:00 Wash Open/Closed, CAW Reset / Emergency Stop 1 0:00:22 6/29/2005 7:32 44 3 6/29/2005 7:32
255 6/29/2005 0:00 Carwash OK 1 0:03:14 6/29/2005 7:35 45 3 6/29/2005 7:3233 6/29/2005 0:00 Machine Not at Home 1 0:00:39 6/29/2005 7:36 46 3 6/29/2005 7:35
255 6/29/2005 0:00 Carwash OK 1 0:36:07 6/29/2005 8:12 47 3 6/29/2005 7:3681 6/29/2005 0:00 Back-Up Air Switch/Photoeye Problem 1 12:58:42 6/29/2005 21:11 48 3 6/29/2005 8:12
12 Month Revenue History (Total)
0
500
1000
1500
2000
2500
6/27
/2005
7/27
/2005
8/27
/2005
9/27
/2005
10/27
/200
5
11/27
/200
5
12/27
/200
5
1/27
/2006
2/27
/2006
3/27
/2006
4/27
/2006
5/27
/2006
6/27
/2006
£’s
Week Commencing
YTD Value Revenue
0
500
1000
1500
2000
2500
1/2/
2006
1/16
/2006
1/30
/2006
2/13
/2006
2/27
/2006
3/13
/2006
3/27
/2006
4/10
/2006
4/24
/2006
5/8/
2006
5/22
/2006
6/5/
2006
6/19
/2006
Duration of Usage (hrs) by Time of Day
0:00:00
24:00:00
48:00:00
72:00:00
96:00:00
120:00:00
144:00:00
168:00:00
192:00:00
6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
There is More
• CAW can also send diagnostic and reports via:• Email
• SMS text messages to cell phones
• Reports could include• Machine status
• Wash counts
• Revenue totals
• Chemical levels
• Other
Equipment Requirements• CAW IV with color touch screen
with iConnect connection option• Ethernet with Firewall or• GSM connection
• Sim Card with Internet Access
• Car Wash• Ryko Net II (retrofit available)
• Remote computer/Server• High Speed Internet with IP Address• Program- Internet Information Service (ITS) • Windows XP Pro• Ethernet
Coinbox Requirement
Touchpad Only Global
AMTT Non EC ONLY
Price ListPART # DESCRIPTION Distributor Price
CAW IV Color Touch Screen iConnect Connectivity Option7100M Ethernet Connection $1,205
7101MEthernet Firewall Kit ( One per local site required for local Ethernet) $150
Recommed w/ Ethernet
7102MEthernet Switch Kit (Required for >6 local Ethernet devices on local Ethernet) $65
Very Large Customers
7104M GSM Cell Phone Connection $1,205
7105MBack-Up Power Supply (recommended for all iConnect applications) $220 optional
Data Acquisition System
7106MData Acquisition Software (PC server customer supplied) $1,105
one per computer/server
7101MEthernet Firewall Kit ( 1 Per Local Site Required for Local Ethernet) $150 optional
7105MBackup Power Supply (Recommended for all iConnect applications) $220 optional
Car Wash Remote Control
7107M Software $1,105one per computer/server
7101MEthernet Firewall Kit ( One per local site required for local Ethernet) $150 optional
FREIGHT, F.O.B. GRIMES, IOWA
iConnect
iConnect
Car Wash Remote Data Acquisition System
RYKO Manufacturing Co.