Page 1: icenta oval gear flow meters

Oval Gear Flow Meters

Traditional, mechanical, positive

displacement flow meters, with oval

shaped gears; first invented more

than 60 years ago by OVAL

Corporation of Japan and now widely

used for flow metering applications

Page 2: icenta oval gear flow meters

OVAL Corporation of JapanA leading manufacturer of precision and speciality flow

meters and is recognised as a pioneer in the field of

flow measurement and control:

• Specialists in flow measurement and control for over 60 years

• Recognised throughout the world for its high quality flow solutions

• Product range based on state-of-the-art and traditional flow technologies

• Modern manufacturing facilities with high precision machining and quality control systems

• Master meters traceable to national and international standards

Page 3: icenta oval gear flow meters

Oval gear meters are available in a

range sizes and designs .......

Page 4: icenta oval gear flow meters

.... and with a range of

gear profiles

Page 5: icenta oval gear flow meters

Example: Compact Oval Gear Flow Meter

The Flowmate series of compact oval gear flow meters offers a

cost effective yet accurate and stable solution for flow

measurement in low flow ranges:

• Flow range 0.1 to 500 L/h or from 0.09 L/hr (size 38)

• Simple, robust construction

• Operating temperature range: -20 to +80°C

• Built-in pulse generator for remote control

• Ideal for metering fuels, fuel oils and lubricants

• Nominal size: BSP 1/8 or 1/4

Page 6: icenta oval gear flow meters

Example: Flanged Oval Gear Flow Meter

The Flowpet EG is a positive displacement, oval

geared flow meter for fuel oil metering or boiler

feed water with high temperature option:

• Robust, proven technology with inherent accuracy of measurement

• Digital LCD register shows total and instantaneous flow

• Meter face can be orientated to any angle over 180°

• Operates on an external power source or internal battery

• Wide flow range covered, up to 24000 L/h for oil service

• High temperature version operating at up to 150°C

Page 7: icenta oval gear flow meters

Oval gear meters

measure flow by

employing a geared

rotor to pass known

volumes of a fluid

through a housing …..

Page 8: icenta oval gear flow meters

Oval GearsDisplay Transmission Gear

Pulse Generator

.... Counting the ‘known volumes’ gives a measurement of the

volumetric flow rate. This is typically achieved by embedding

magnets in the rotors, which then actuate a reed switch or

provide a pulse output as they rotate.

Page 9: icenta oval gear flow meters

OVAL Gear Flow Meter Advantages• Traditional proven flow technology

• Simple to install

• No straight pipe runs required so flow meters can be installed in restricted areas

OVAL Gear Flow Meter Limitations• Not suitable for steam or multi-phase fluids

• Fluid slippage adversely affects accuracy; this varies with flow rate, differential pressure, temperature, viscosity and clearance

• Accuracy adversely affected by bubbles present in fluids

Page 10: icenta oval gear flow meters

OVAL Gear Flow Meter Applications

The oval gear flow meter is designed primarily for use with higher-

viscosity fluids, which has led to applications in metering of oils,

syrups and fuels, for example:

• Dosage and metering of additives

• Determination of net fuel consumption

• Leakage monitoring

• Fuel cell applications

• Fuel oil metering

• Shipping and accepting petroleum products

Page 11: icenta oval gear flow meters

The main questions which need to be considered

before selecting an oval gear flow meter:

• What is the viscosity range of the fluid being metered?

• What is the minimum and maximum working flow range?

• Is the fluid clean; are there any solids present?

• What is the minimum and maximum process pressure?

• What is the minimum and maximum process temperature ?

• What is the degree of accuracy required?

• Is an output required and, if so, what type?

• Is the meter operating in a hazardous area?

• Are specific approvals (eg ATEX) required?

• Is a flow instrument required?

• What type of connection is required?

Page 12: icenta oval gear flow meters

For more information or to discuss your application, please contact

icenta Controls LtdExclusive distributor in the UK for OVAL Corporation of Japan