This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
(size approx. 68 mm x 102 mm) TERMINAL DESCRIPTION
Figure 2: Terminals
P1 5 V Power Jack (plus pole on inside)P2 5 V External Supply Input and Ground
Change power selection jumper to EXT.(Typ. ≈ 60 mA, ≈ 130 mA with loaded outputs)
P3 USB Connector (Mini B)
P4* External SPI Interface(for in-circuit programming of externaliC-TW28)
P5 Board Power Selector:from USB (P3) or EXT (P1 or P2)
P6* External Encoder Link Interface(for in-circuit programming of externaliC-TW28)
P7 Controller Interface(factory programming)
P8 Terminal to on-board LED D7
P9 Sensor Interface (Inputs)3.3 V Supply Output to SensorSIN +/– Sine Signal InputsCOS +/– Cosine Signal InputsZERO +/– Index Signal InputsGND Ground Link to SensorLED LED Output of iC-TW28
P10 Onboard SPI InterfaceThis port is controlled by the evalboard’s MCU when the GUI is running.
P11 Encoder Interface (Outputs)3.3 V Supply OutputA+, A– A/U Signal OutputsB+, B– B/V Signal OutputsZ+, Z– Z/W Signal OutputsGND Ground Link
The TW28_1D evaluation board can be used as a pro-gramming adapter for in-circuit programming of an ex-ternal iC-TW28 (the target device). The target devicecan be a second evaluation board or part of a customermodule or product.
Two methods are provided for in-circuit programming,SPI and Encoder Link. SPI programming can only beused when the external iC-TW28 is in serial configura-tion mode (PINCFG = 0V). Encoder Link programmingcan be used in both serial and pin configuration modes.
SPI ProgrammingFor SPI programming, the external SPI interface ofthe TW28_1D evaluation board (P4) is used to com-municate with the target device. The target iC-TW28must be in serial communication mode (PINCFG = 0V)
and powered. The required connections are shown inTable 1.
For example, if the target device is a second TW28_1Devaluation board, connect P4 of the first TW28_1Dboard (the PC adapter) to P10 of the second board (thetarget device) as shown in Figure 4.
Figure 4: Using the TW28_1D as a PC Adapter for SPI Programming of a Target Device
The target TW28_1D board must be powered externallyusing either P1 (as shown) or P2, and P5 must be set toEXT. Do not connect a PC to the USB interface (P3) onthe target board. Note that when using a 10-conductorribbon cable as shown, the xIRQ LED (D8) on the targetTW28_1D board is illuminated whether or not a fault orinterrupt request exists.
The PC adapter TW28_1D board is connected to a PCrunning the GUI software and powered from the USBinterface (P5 set to USB). Activate the external SPI in-terface on the PC adapter TW28_1D board by selectingSPI from the GUI Interface menu as shown in Figure 5.
Figure 5: Activating the External SPI Interface
The SPI LED (D6) near P4 illuminates to indicate thatthe external SPI interface is active.
Confirm SPI communication with the target iC-TW28 byverifying that the chip serial number in the Device Infoblock of the GUI is that of the target device and not thatof the iC-TW28 on the PC adapter TW28_1D board asshown in Figure 6.
Figure 6: Verify Target iC-TW28 Serial Number
Encoder Link ProgrammingFor encoder link programming, the external encoderlink interface of the TW28_1D evaluation board (P6) isused to communicate with the target device using theA+ and A– encoder outputs. The required connectionsare shown in Table 2.
For example, if the target device is a second TW28_1Devaluation board, connect P6 of the PC adapterTW28_1D board (left) to P11 of the target TW28_1Dboard (right) as shown in Figure 7.
Figure 7: Using the TW28_1D as a PC Adapter for Encoder Link Programming of a Target Device
The target TW28_1D board must be powered externallyusing either P1 (as shown) or P2, and P5 must be setto EXT. Do not connect a PC to the USB interface (P3)on the target board. Any terminating resistor on the A+or A– outputs of the target device must be removedbefore attempting to use encoder link.
The PC adapter TW28_1D board is connected to a PCrunning the GUI software and powered from the USBinterface (P5 set to USB). Enable the external encoderlink interface on the PC adapter TW28_1D board byselecting ELink from the GUI Interface menu as shownin Figure 8.
Figure 8: Enabling the External Encoder LinkInterface
The ELink LED (D5) near P6 illuminates to indicate thatthe external encoder link interface is enabled.
Activate the encoder link interface on the PC adapterTW28_1D board by clicking Start ELink in the GUI Inter-face menu (see Figure 8). This sends the encoder linkactivation sequence from the PC adapter TW28_1Dboard to the target.
Confirm encoder link communication with the targetiC-TW28 by verifying that the chip serial number in theDevice Info block of the GUI is that of the target de-vice and not that of the iC-TW28 on the PC adapterTW28_1D board as shown in Figure 6.
Note that if the target board is reset or power cycled,encoder link must be re-activated by clicking Start Elinkin the GUI Interface menu again.
iC-Haus expressly reserves the right to change its products and/or specifications. An Infoletter gives details as to any amendments and additions made to therelevant current specifications on our internet website www.ichaus.com/infoletter and is automatically generated and shall be sent to registered users by email.Copying – even as an excerpt – is only permitted with iC-Haus’ approval in writing and precise reference to source.
The data specified is intended solely for the purpose of product description and shall represent the usual quality of the product. In case the specifications containobvious mistakes e.g. in writing or calculation, iC-Haus reserves the right to correct the specification and no liability arises insofar that the specification was froma third party view obviously not reliable. There shall be no claims based on defects as to quality in cases of insignificant deviations from the specifications or incase of only minor impairment of usability.No representations or warranties, either expressed or implied, of merchantability, fitness for a particular purpose or of any other nature are made hereunderwith respect to information/specification or the products to which information refers and no guarantee with respect to compliance to the intended use is given. Inparticular, this also applies to the stated possible applications or areas of applications of the product.
iC-Haus products are not designed for and must not be used in connection with any applications where the failure of such products would reasonably beexpected to result in significant personal injury or death (Safety-Critical Applications) without iC-Haus’ specific written consent. Safety-Critical Applicationsinclude, without limitation, life support devices and systems. iC-Haus products are not designed nor intended for use in military or aerospace applications orenvironments or in automotive applications unless specifically designated for such use by iC-Haus.iC-Haus conveys no patent, copyright, mask work right or other trade mark right to this product. iC-Haus assumes no liability for any patent and/or other trademark rights of a third party resulting from processing or handling of the product and/or any other use of the product.
Software and its documentation is provided by iC-Haus GmbH or contributors "AS IS" and is subject to the ZVEI General Conditions for the Supply of Productsand Services with iC-Haus amendments and the ZVEI Software clause with iC-Haus amendments (www.ichaus.com/EULA).