Page 1
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Jacob Fred Channel Technical Sales Specialist
IBM Systems and Technology Group
Tel: +55 11 2322 7089Mobile: +55 11 97597 9133
Tie Line 740 7089E-mail: [email protected]
IBM PureSystemsSKiLLs – Webcast2012
Page 2
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM PureFlex SystemsIBM Flex System Overview xtw280t1
Abril 2012
Page 3
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Agenda
IBM Flex System Overview
IBM Flex System Enterprise Chassis Overview
Nodes Overview
I/O Overview
Management Overview
Power Overview
Cooling Overview
Rack Overview
Soluções Oferecidas
Page 4
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM Flex System Overview
Proteção de investimento de avançada tecnologia por diversos anos– Novos processadores, memória, I/O, Storage– Barramentos internos de maior velocidade– I/Os ainda mais rápidos
Novo IBM Flex System Manager – Suportado para gerenciar múltiplos IBM Flex System Enterprise Chassis
Novos Compute e Storage Systems Novos Scalable Switch Elements (ScSE) e I/O adapters Novo IBM Flex System Enterprise Chassis Management Module Mais eficiência de energia e sistema de resfriamento
– Componentes de máxima eficiência– Sofisticado e prático controle do sistema– Compatível com futuras instalações de infraestrutura
de Data Centers de alta eficiência
Page 5
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM Flex System Enterprise Chassis - Overview
Chassis– 10 U (Rack Units)– 14 baias de Nodes
• Suporte para Nodes de tamanhos half e full• Suporte para Nodes duplos• Suporta interconexão de Nodes de expanção
– 4 baias de Switch– 2 baias de Gerenciamento– 6 Power Supplies (2 já inclusas)– 10 baias de FANs
Page 6
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM Flex System Enterprise Chassis - Frente
Storage node
Half node
Full node
Manager node
Page 7
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Power Supplies (6X)Scalable Switch Elements (4X)
40 mm Fans (2X)
IBM Flex System
Enterprise Chassis
Management Modules (2X)
80 mm FanPacks (8X)
Fan MuxCard (2X)
IBM Flex System Enterprise Chassis - Trás
Page 8
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Node Bay Shelf
- Remove para Node Full Wide
- Remove dois Shelves para Node Full Wide, Double High
IBM Flex System Enterprise Chassis
Shuttle
IBM Flex System Enterprise Chassis - Baias
Page 9
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Compute Nodes - Flex System Manager
IBM Flex System Manager (8731)– Appliance de gerenciamento– Node de baia Half-wide– 2 sockets Sandy Bridge-EP
• 1 – 8 Cores 2.0GHz 20MB L3 95W– 24 LP DDR3 DIMM Sockets / 1600MT/s
• 32GB DDR3 SDRAMS– 8x 4GB
– 1x HS 2.5” 1TB SAS HDD– 2x 1.8” 200GB SSDs (RAID 1)– Systems Management Software Stack
• Ferramenta de fácil implementação• Ferramentas de Automação de Virtualização• Ferramentas de Migração de Workload
Page 10
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Compute Nodes - Flex System Manager IBM PureApplication System IBM Flex System Manager (7955)
– Appliance de gerenciamento– Node de baia Half-wide– 2 sockets Sandy Bridge-EP
• 2 – 8 Cores 2.0GHz 20MB L3 95W– 24 LP DDR3 DIMM Sockets / 1600MT/s
• 192GB DDR3 SDRAMS– 24x 8GB
– 1x HS 2.5” 1TB SAS HDD– 2x 1.8” 200GB SSDs (RAID 1)– IBM Flex System CN4054
10Gb Virtual Fabric Adapter– IBM Flex System FC3172 2-port 8Gb FC Adapter– Systems Management Software Stack– IBM Workload Deployer
Page 11
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Compute Nodes - Intel EP
IBM Flex System x240 Compute Node– Node de baia Half-wide– 2 sockets Sandy Bridge-EP– 24 LP DDR3 DIMMs / 1600MT/s– 2 HS 2.5” SAS/SATA HDDs or SSDs
Trás
Frente
Page 12
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Compute Nodes - POWER 7
IBM Flex System p260 Compute Node – Node de baia Half-wide– 2 sockets POWER 7
• 64-bit Power7 RISC processor 190w• 8 cores
– 16 VLP DIMMs DDR3, 1066MT/s, 256GB Max – 2x 2.5 SAS/SATA HDDs ou SSDs
IBM Flex System p460 Compute Node – Node de baia Full wide– 4 sockets POWER 7
• 64-bit Power7 RISC processor 190w• 4 / 8 cores
– 32 VLP DIMMs DDR3, 1066MT/s, 256GB Max– 2x 2.5 SAS/SATA HDDs ou SSDs
Page 13
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM Flex System V7000 Storage Node
IBM Storewize V7000 Storage System– Node de baias Double High / Full Width– 24x 2.5” HDDs ou SSDs– Duas controladoras hot swappable para alta disponibilidade
Trás
Frente
Page 14
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Compute Nodes - I/O
Ethernet– IBM Flex System EN2024 4-port 1Gb Ethernet Adapter P e X– IBM Flex System EN4054 4-port 10Gb Ethernet Adapter P somente– IBM Flex System CN4054 10Gb Virtual Fabric Adapter X somente– IBM Flex System CN4054 Virtual Fabric Adapter X somente– IBM Flex System EN4132 2-port 10Gb Ethernet Adapter X somente
FibreChannel– IBM Flex System FC3172 2-port 8Gb FC Adapter P e X– IBM Flex System FC5022 2-port 16Gb FC Adapter X somente, P futuro– IBM Flex System FC3052 2-port 8Gb FC Adapter P* e X
InfiniBand– IBM Flex System IB6132 2-port QDR InfiniBand Adapter P somente– IBM Flex System IB6132 2-port FDR InfiniBand Adapter X somente
* Não suportado com AIX
Page 15
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
I/O - Scalable Switch Element (ScSE)
Ethernet I/O– IBM Flex System EN4091 10Gb Ethernet Pass-thru– IBM Flex System EN2092 1Gb Ethernet Scalable Switch– IBM Flex System EN4093 10Gb Virtual Fabric Scalable Switch– FoD Enhancement Licenses
FibreChannel I/O– IBM Flex System FC5022 16Gb SAN Scalable Switch– IBM Flex System FC5022 16Gb ESB SAN Scalable Switch– FoD Enhancement Licenses
InfiniBand I/O– IBM Flex System IB6131 InfiniBand Switch– FoD Enhancement Licenses
Page 16
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM Flex SystemEnterprise Chassis Management Module Monitors IBM Flex System
Operating Parameters Coleta de inventário Atualização de Firmwares Gerenciamento Low Level
de Nodes Configuração L2 de Switch e
gerenciamento Interface de usuário Web,
CLI, SNMP, CIM
Para redundância, utilize dois Enterprise Chassis Management Module
Page 17
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM Flex System - Power Supplies
Suporte para até 6 Power Supplies Inclui 2 Power supplies por padrão I2C Managed Element 2500W 208 - 240VAC Input Range 12.2VDC 205A - 225A Output Range 92% eficiência em plena carga Redundância N+M, N+N, N+1
Page 18
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Cooling Resfriamento direcionado - Nodes (esq./ dir.), switches Escalável / Expansível 2x FANs de 40mm para ScSEs (Scalable Switches) Até 8 FANs de 80mm para Nodes (4 inclusos) Controle de resfriamento adaptável Acústica avançada e otimizada Eficiência líde de indústria Melhoria das características
de operacionalidade
80mm Fan40mm Fan
Fan Multiplexer Card
Page 19
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM 42U 1100mm Deep Dynamic Rack
Novo IBM Rack otimizado– 100mm mais fundo que os racks
padrões, ocupando 2 placas de piso elevado
– Nova porta com dissipador de calor disponível
Trilhos do chassis de fácil instalação
Orgnização de cabos aprimorado– Ampla saída de cabos– Pistas de cabos da frente para trás
6 encaixes laterais de PDU
Cable Egress
Rear of Rack
Cable Channels
Strip PDU Support 4X
Cable Egress
Cable Egress
Cable Channels
Thermal Sealing Plane (front EIA flange)
Rear PDU Access 6x
Front of Rack
Cable Tie Points Outrigger
Page 20
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM PureFlexConfig mínima Express Standard Enterprise
HardwareRack Incluso Incluso InclusoChassis Incluso Incluso InclusoPower Supplies / Fans 2/4 4/6 6/8Ethernet Switch BNT 10GB BNT 10GB BNT 10GB (2)TOR Switch n/a n/a 2 Eth,2 FC – somente PowerFC Switch QLogic 8GB QLogic 8GB (2) QLogic 8GB (2)FSM HW Incluso Incluso Incluso V7000 HW Incluso
com DrivesIncluso
com DrivesIncluso
com Drives
INode P260 ou x P260 / p460 ou x Dois p460 ou Dois xMezz cards FC, Enet FC(2), Enet FC(2), Enet (2)
SoftwareV7000 SW Incluso Incluso InclusoFSM SW Incluso Incluso InclusoOS Incluso Incluso InclusoPowerVM (Power only) Incluso Incluso InclusoPowerSC (Power only) Incluso Incluso InclusoSmart Cloud Entry opcional Incluso / possível deselecionar Incluso / possível deselecionarServicesSWMA 1 ano 9x5 3 anos 9x5 default
1 ano 9x5 selectable3 anos 9x5
HWMA 3 ano 9x5 3 ano 9x5 3 anos 9x5MTS 3 anos microcode (1) 3 anos microcode (1)
WSU 24x7Account Advocate 9x5
3 anos microcode (2)WSU 24x7
Account Advocate 24x7
Lab Services 3 dias 5 dias 7 dias
Page 21
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM PureFlex
IBM PUREFLEX SYSTEM
EXPRESS STANDARD ENTERPRISEFEATURE
CODE DESCRIPTION
1 1 1 Flex System Enterprise Chassis (7893-92X), with the following features:
1 1 2 #3593 IBM FLEX System EN4093 10 Gb Virtual Fabric Scalable Switch
2 #3596 Port Upgrade1 for #3593
2 #3597 Port Upgrade 2 for #3593
1 2 2 #3595 IBM Flex System FC3171 8 Gb SAN Switch
2 4 4 #3282 10 GbE SFP+ Transceiver
2 4 8 #3286 8 GB SFP+ Transceiver
5 5 6 #EB29 1000Base-T SFP RJ45 Transceiver
1 1 1 #9039 Base CME
1 1 1 #3592 Redundant CME
2 2 2 #9059 Base Power Module (2X)
2 4 #3590 Redundant Power Module
2 4 6 #4558 Power Cord (2.5M) to PDU/UPS
1 1 1 #9038 Base Fans (4X)
1 2 #7805 Additional Fans (2X)
2 2 2 #1111 CAT5E Ethernet Cable, 3M Blue
4 #ECB4 10 GbE SFP+ Copper DAC Cable,1 M
1 1 1 #EFM1 Open Fabric Manager
Page 22
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM PureFlex
IBM PUREFLEX SYSTEM
EXPRESS STANDARD ENTERPRISEFEATURE
CODE DESCRIPTION
1 1 1 Flex System Manager (FSM) (7955-01M), with the following features:
1 1 1 #EB31 Platform Manager S/W Bundle
4 4 4 #EM09 32 GB Memory
2 2 2 #1771 IBM 200 GB 1.8" SATA SSD
1 1 1 #3767 1TB 7.2K RPM 2.5" SATA Disk Drive
1 1 2 Flex System x240 Compute Node (7863-10X), with the following features:
1 1 1 #EN20 Compute Node with 10Gb Virtual Fabric
or or
1 1 1 #EN21 Compute Node without 10Gb Virtual Fabric
1 1 1#EM05 or #EEM2 4 GB minimum memory
1 1 1 #1759IBM Flex System CN4054 10 Gb Virtual Fabric Adapter (Not required with #EN20)
1 1 1 #1764 IBM Flex System FC3172 2-port 8Gb Fibre Channel Adapter
1 1 1 #EBK2 IBM Flex System x240 USB Enablement Kit
1 1 1 #EBK3 2 GB USB Hypervisor Key (VMWare 5.0)
Page 23
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM PureFlex
IBM PUREFLEX SYSTEM
EXPRESS STANDARD ENTERPRISEFEATURE
CODE DESCRIPTION
1 1 1 Storwize V7000 Disk System (2076-124), with the following features:
1 1 1 #0010 Storwize V7000 S/W Preload
2 4 4 #5305 1M or 5M Fiber Optic Cable
8 8 8 #3206 600 GB 2.5-inch 20k HDD
2 2 4 #3512 or #3214 200 or 400 GB 2.5-inch SSD
2 2 2 #6008 Cache 8 GB
1 1 1 #9730 Power Cord - PDU Connection
2 2 2 #9801 AC Power Supply
1 1 1 Flex System Enterprise Rack (7953-94X), with the following features:
2 2 2 #7189 or #7196 Optional PDUs
1 1 1 #EC02 or #EC05 Rack Rear Door or RDHX
1 1 1 #EC03 Side Doors
1 1 1 #EC06 Rack Front Door
Page 24
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM SmartCloud Entry
Self Service Private Cloud Portal Permite o cliente:
– Provisionar (implantação) e de-provisionar servidores virtuais– Elaboração e clone de workloads virtualizados– Tirar workloads snapshots– Inicializando e desligando servidores virtuais como parte de um workload– Redimensionando servidores virtuais existentes
Estes e muitos outros features estão inclusos nesta versão do IBM SmartCloud Entry
https://www.ibm.com/developerworks/mydeveloperworks/wikis/home/wiki/W21ed5ba0f4a9_46f4_9626_24cbbb86fbb9?lang=en
Page 25
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM PureApplication System - High Performance Model
1 U2 U3 U4 U5 U6 U7 U8 U9 U10 U11 U12 U13 U14 U15 U16 U17 U18 U19 U20 U21 U22 U23 U24 U25 U26 U27 U28 U29 U30 U31 U32 U33 U34 U35 U36 U37 U38 U39 U40 U41 U42 U
V 7000 Controller
V 7000 Expansion
V 7000 Controller
V 7000 Expansion
BNT 64 PT Enet SW
BNT 64 PT Enet SW
Cable ingress / egress
PD
UP
DU
PD
UP
DU
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
MGMT MGMT
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
Intel Compute Intel Compute
MGMT MGMT
Cable ingress / egress
Intel Compute2.6 GHz 8C Intel processor, 110 W
256 KB L2 per core 4 MB eDRAM L3 per core
2x 4 Port 10 GbE 2x 2 Port 8 Gb/s FC
New ChassisCommon Management Module
2x 10Gb Ethernet Switch2x 16 Gb FC Switch
VM Management Node
Top of Rack SwitchesBLADE Network Technologies Top of
Rack SwitchesCustomer Data Center & Rack-to-rack
communications
IBM PureApplication System Management Node
IBM Workload Deployer
V7000 Disk ExpansionPer enclosure:
4 x 400 GB SAS SSD20 x 600 GB SAS HDD
Storage ControllerIBM Storwize V7000 Disk System
4 x 400 GB SAS SSD per enclosure20 x 600 GB SAS HDD per enclosure
Overall
Power ~30 KW
Cores 608 Cores
Memory 9.7 TB
SSD 6.4 TB (unformatted)
Storage 48.0 TB (unformatted)
http://www-01.ibm.com/software/webservers/workload-deployer/
Page 26
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM PureApplication – Soluções OferecidasSmall
(Part 1)Medium(Part 2)
Large(Part 3)
Cores/Threads 96/384 192/768 384/1536 608/2432PVUs 9600 19200 38400 60800Memory (GB) 1536 3072 6144 9728Raw SSD/HDD (TB) 6.4 / 48 6.4 / 48 6.4 / 48 6.4 / 48Usable SSD/HDD (TB) 4.8 / 38.4 4.8 / 38.4 4.8 / 38.4 4.8 / 38.4PDU L Volt 4x60A 3ph 4x60A 3ph 4x60A 3ph 4x60A 3phPDU H Volt 4x32A 3ph 4x32A 3ph 4x32A 3ph 4x32A 3phPower (Max) 10.6 kW 14.4 kW 22.2 kW 31.2 KWApplication Services Included Included Included Included
1 U2 U3 U4 U5 U6 U7 U8 U9 U10U11U12U13U14U15U16U17U18U19U20U21U22U23U24U25U26U27U28U29U30U31U32U33U34U35U36U37U38U39U40U41U42U
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
V7000 Controller
V7000 Expansion
V7000 Controller
V7000 Expansion
Enet SW 64 PTEnet SW 64 PT
Mgmt
Mgmt
1 U2 U3 U4 U5 U6 U7 U8 U9 U10U11U12U13U14U15U16U17U18U19U20U21U22U23U24U25U26U27U28U29U30U31U32U33U34U35U36U37U38U39U40U41U42U
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
V7000 Controller
V7000 Expansion
V7000 Controller
V7000 Expansion
Enet SW 64 PTEnet SW 64 PT
Mgmt
Mgmt
1 U2 U3 U4 U5 U6 U7 U8 U9 U10U11U12U13U14U15U16U17U18U19U20U21U22U23U24U25U26U27U28U29U30U31U32U33U34U35U36U37U38U39U40U41U42U
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
V7000 Controller
V7000 Expansion
V7000 Controller
V7000 Expansion
Enet SW 64 PTEnet SW 64 PT
Mgmt
Mgmt
1 U2 U3 U4 U5 U6 U7 U8 U9 U10U11U12U13U14U15U16U17U18U19U20U21U22U23U24U25U26U27U28U29U30U31U32U33U34U35U36U37U38U39U40U41U42U
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
Mgmt
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4SP7 FW Firebird 4S
P7 FW Firebird 4S
V7000 Controller
V7000 Expansion
V7000 Controller
V7000 Expansion
Enet SW 64 PTEnet SW 64 PT
Mgmt
MgmtCompute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute Nodes
Compute NodesCompute Nodes
Part #7Part #5 Part #6
Page 27
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Page 28
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
IBM Flex System – Tour Virtual
• Enterprise Chassis
http://www-03.ibm.com/systems/data/flash/flex/virtual-tours/chassis/index.html
• x240 Compute node
http://www-03.ibm.com/systems/data/flash/flex/virtual-tours/compute-nodes/x240/index.html
• x440 Compute node
http://www-03.ibm.com/systems/data/flash/flex/virtual-tours/compute-nodes/x440/index.html
• p460 Compute node
http://www-03.ibm.com/systems/data/flash/flex/virtual-tours/compute-nodes/p460/index.html
Page 29
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Skill 1 - IBM PureFlex Systems - Posicionamento (Técnico/Comercial)Dia: 16/08/2012Horário: das 10:00h às 11:30hLink de inscrição:https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpru&lang=pt-BR
Skill 2 - IBM PureFlex Systems - IBM Flex System Enterprise Chassis Overview (Técnico)Dia: 23/08/2012Horário: das 10:00h às 11:30hLink de inscrição:https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpta&lang=pt-BR
Skill 2 - IBM PureFlex Systems - IBM Flex System Nodes OverviewDia: 30/08/2012Horário: das 10:00h às 11:30hLink de inscrição:https://www-950.ibm.com/events/wwe/ap/apeptreg.nsf/enrollall?openform&seminar=kworfbm8wqpuh&lang=pt-BR
PureSystems - Webcasts Brasil 2H-2012Foco na certificação técnica
Acompanhe o comunicado de canais para mais datas!
Page 30
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Dúvidas?
Jacob [email protected]
Page 31
© 2012 IBM CorporationThis document is for IBM and IBM Business Partner use only
Obrigado!