This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Hydraulic piston pumps
Model 1: *CY14-1B (F) Series Pumps
Ordering Code:
Specification: Theoretic
Flow(LPM)
Max,
theoretic
Torque(N.m)
Type Nominal
Pressure
(Mpa)
Nominal
Displacement
(CC/rev)
1000rpm 1500rpm
Max Drive power
KW
1000rpm
2.5 MCY14-1B 31.5 2.5 2.5 3.75 1.43 17.5
MCY14-1B
SCY14-1B
YCY14-1B
PCY14-1B
10
MYCY14-1B
BCY14-1B
31.5 10 10 15 5.7 54.6
MCY14-1B
SCY14-1B
YCY14-1B
PCY14-1B
25
MYCY14-1B
BCY14-1B
31.5 25 25 37.5 14.1 134.9
40 MCY14-1B
SCY14-1B
31.5 40 40 60 22.6 201.5
www.hydraulics-china.com
www.hydraulics-china.com
www.hydraulics-china.com
YCY14-1B
PCY14-1B
MYCY14-1B
BCY14-1B
MCY14-1B
SCY14-1B
YCY14-1B
PCY14-1B
63
MYCY14-1B
BCY14-1B
31.5 63 63 94.5 35.6 339.9
MCY14-1B
SCY14-1B
YCY14-1B
PCY14-1B
80
MYCY14-1B
BCY14-1B
31.5 80 80 120 46.6 405.1
MCY14-1B
SCY14-1B
YCY14-1B
PCY14-1B
160
MYCY14-1B
BCY14-1B
31.5 160 160 240 92.2 880.3
MCY14-1B
SCY14-1B
YCY14-1B
PCY14-1B
250
MYCY14-1B
BCY14-1B
31.5 250 250 375 133.2 1272.4
MCY14-1B
SCY14-1B
YCY14-1B
PCY14-1B
400
MYCY14-1B
BCY14-1B
31.5 400 400 199.5 1905.2
When the nominal pressure is 31.5MPa,the displacement with 1.25、5、13、16、32、100ml/r also can offer.
www.hydraulics-china.com
www.hydraulics-china.com
www.hydraulics-china.com
MCY14-1B Series
Slanting disc type quota ram pump/Motor
STRUCTURE:
PRINCIPLE OF WORKING:
The main body are partial (sees also structure to split) revolves by the drive shaft impetus cylinder body, causes the u
distribution to circle the drive shaft middle line rotation on the cylinder body seven plungers, presses through the central
www.hydraulics-china.com
www.hydraulics-china.com
www.hydraulics-china.com
column slippery module in slippery boots in variable (or slanting plate) on. Thus, the plunger revolves along with the cylindebut makes the reciprocal motion, completes blots and presses the oil movement.
In the quota organization the slanting plate fixes throughout on the quota end cover, cannot change the plunger the traveling therefore its current capacity is fixed. Should pump only must replace matches the oil disk also to be possible to take the oil m POWER COMPUTATION: N=QP/ (60η) (Kw) Actual use electrical machinery power Q——Current capacity L/min (Actual use current capacity) P——Pressure MPa (Actual working pressure) η——Overall effectiveness index 0.85 the user may select the electrical machinery according to the actual use load after the upper row formula computation.