CUMMINS CONFIDENTIAL HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project Team Members: Kaela Hlaulani Prince Bedell William Broaddus Derek Vleck Trever Zike Seth Simonson
16

HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

Mar 21, 2016

Download

Documents

Said

HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project. Team Members: Kaela Hlaulani Prince Bedell William Broaddus Derek Vleck Trever Zike Seth Simonson. Goals. Calculate HDD Furnace on time Number of on-off cycles Heat Loss Correlate Data. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

HVAC Project

ME 414 – Thermal Fluid System DesignProfessor John Toksoy

Final Project

Team Members:Kaela HlaulaniPrince Bedell

William BroaddusDerek VleckTrever Zike

Seth Simonson

Page 2: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Goals Calculate HDD Furnace on time Number of on-off cycles Heat Loss Correlate Data

Page 3: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

HDD & Furnace On Time

Date HDD Calculated

HDDActual % Error Furnace

on Time

# of On-Off Cycles Calculated

# of on-off Cycles Seen on Graph

Difference Btwn Calc and Graph

1/22 31.93 30.0 6.04% 2.24 29 29 0

1/28 49.39 48.0 2.81% 2.04 51 51 0

1/29 50.79 50.0 1.56% 2.65 59 59 0

2/3 37.98 37.0 2.58% 1.42 33 33 0

2/4 35.68 35.0 1.91% 1.72 48 48 0

2/5 37.39 32.0 14.4% 1.79 57 57 0

2/6 46.11 41.0 11.1% 1.43 50 50 0

Page 4: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

HDD Calculated Vs. HDD Published

Page 5: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Furnace On Time Vs. HDD Calculated

Page 6: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Furnace On Time Vs. HDD Published

Page 7: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

On – Off Cycles

Page 8: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Calculated On/Off Cycles Vs. Observed

Page 9: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

First Floor Areas (ft.2)

Walls Windows Doors Total

North 288.41 117.55 20.45 426.4

South 386.53 131.22 20.25 538.0

East 360.23 0 18.17 378.4

West 289.71 0 0 289.71

Page 10: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Second Floor Areas (ft.2)

Walls Windows Doors Total

North 499.94 75.71 0 575.65

South 346.79 16.40 0 363.20

East 371.72 0 0 371.72

West 162.50 0 0 162.50

Page 11: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Basement Areas (ft.2)

Walls Windows Doors Total

North 142.29 0 0 142.29

South 263.42 0 0 263.42

East 291.13 0 0 291.13

West 157.25 0 0 157.25

Page 12: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

House Total (ft.2)

Walls Windows Doors Total

North 930.64 193.25 20.45 1144.34

South 996.74 147.62 20.25 1164.61

East 1023.08 0 18.17 1041.24

West 805.90 0 0 805.90

Walls (cedar) Walls (brick)

1310.57 1342.80

Page 13: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

R - Values

Walls (Brick) 5.63

Walls (Cedar) 5.94

Windows 2.00

Doors 1.00

Page 14: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Heat Losses

Date Avg. T-Out

DeltaT

Wall Heat Loss

Window Heat Loss

Door Heat Loss

Total Heat Loss

1/22 1.64 17.74 8144.70 3023.40 1044.24 12212.351/28 -9.22 27.44 12598.85 4050.78 1615.31 18264.941/29 -9.61 28.22 12956.30 2082.85 1661.14 16700.302/3 -2.15 21.10 9686.77 1557.24 1241.95 12485.962/4 -0.50 19.82 9101.74 1463.19 1166.95 11731.872/5 0.19 20.77 9538.45 1533.39 1222.94 12294.792/6 -5.14 25.61 11760.62 1890.64 1507.84 15159.10

Page 15: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

House Heat Loss

Month Heat Loss BTU/hr

Heat Loss Therms/mo

nthBTU/day Therms/

day BTU/month Therms/month

December 10321.10 76.79 247706.40 2.48 7678898.40 76.79

January 12744.70 94.82 305872.80 3.06 9482056.80 94.82

February 10613.50 71.32 254724 2.55 7132272 71.32

March 5220.50 38.84 125292 1.25 3884052 38.84

Page 16: HVAC Project ME 414 – Thermal Fluid System Design Professor John Toksoy Final Project

CUMMINS CONFIDENTIAL

Conclusion

HDD calculated vs. HDD published strong correlation and minimal error.

Excel program was modified to yield accurate furnace on/off calculations

Furnace on time vs. HDD & calculated vs. HDD published showed a poor correlation.

House Heat loss calculations yielded reasonable results.