Drive electronics pQ12Amplifier module with constant current controller for proportional valves 7503109.06.02.06 • Control of one solen oid • Easy mounting directly on bearing rails acc . to EN 50022 • Standard voltage and current signal forsetpoint inputs • Control from computer also possible • Impressed sol enoi d current, thus no change in the control variable due to environmental influences (e.g. tempera- tures and main fluctuations) Mounting position: Any position Ope rat ing temper ature: 0 to +50°C Weight: 0.18 kg Protection class: IP20 Electrical connect ion: Screw terminals up to 2.5 mm 2 Technical data Drive electronics for proportional valve, output current 0 to 1000 mA Ty p: 598 012 7 Ordering information SymbolHERION Systemtechnik GmbH Untere Talstraße 65 D-71263 Weil der Stad t- Merklingen Tel.: +49 (0) 70 33/30 18-0 Fax: +49 (0) 70 33/30 18-10 www.herion-systemtechnik.de [email protected]
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Drive limitation „A B“ (Fig. 1)If the customer-specific working range represents onlypart of the valve adjustment range, the trimming poten-tiometer „A B“ can be used to match the working rangeto the full setpoint signal from 0 to 100%. This providesthe possibility of assignment a defined pressure or adefined flow volume to the end point in order to obtaingreater resolution.
Zero pointVia a potentiometer the solenoid current can beincreased. This is possible in two ways. For theselection use jumper D2 according to the installationinstructions.
Zero-shift (Fig. 2)Via the trimming potentiometer „NUL“ the solenoidcurrent can be increased. This provides the possibilityof assigning a defined pressure or defined flow volumeto the start point (setpoint = 0).
Zero-step function (Fig. 3)By means of the zero-step function, valve overlappingcan be eliminated. As soon as the setpoint adjustmentis exceeded by more than 2% the solenoid current israised corresponding to the adjustment of the trimmingpotentiometer „NUL“. This way it is assured that withsetpoint = 0 the solenoid current is 0 mA.
Ramp shaper (Fig. 4)Trimming potentiometer F2 „RMP“The ramp module provides a ramp-like change of the
solenoid current if the setpoint changes abruptly. Thefinal value of the solenoid current thereby correspondsto the setpoint. The adjustment time between two wor-king points can be adjusted, measured with a setpointchange of 100%. The ramp shaper is switched off withthe jumper F1 (refer to installation instructions).
Dither amplitude (Fig. 5)Trimming potentiometer „OSZ“In order to improve the hysteresis characteristics in avalve, static friction on the valve piston must beavoided. This is achieved by superimposing a dither signal on the valve current. Via the trimming potentio-meter„OSZ“ the amplitude of the superimposed current
can be adjusted within the range of 0 to 30% of therated current.Optimum setting is achieved when small changes in thesetpoint are registered on the final control element. Theminimum dither amplitude possible should be used atall times. The frequency can be switched on from 40 Hzto 80 Hz with the switch C1 (refer to installationinstructions).
Voltage supply 18 ... 32 V (incl. residual ripple.)Excess voltage may destroy the electronic system!
2. Avoidance of interferences
2.1 Screening
In order to prevent interferences by electric fields,
screened lines must be used. The screen must beconnected to PE (see circuit diagram).
2.2 Laying of cables
Supply and signalling lines shall not be laid in parallel topower mains or high-voltage lines.
3. Line cross section
According to VDE 01134.
Zero potentials
For zero potentials (0 V), the supply voltage and the
setpoint signal, two separate wires must be used inorder to prevent distortion of the setpoints.
General
Transport, storage, default setting, cleaning
The product can only be transported and stored in theoriginal Herion packaging which ensures suitableprotection against mechanical damage.The product is shipped in a ready-to-operate-state(default settings). After correct installation, it is readyfor use.
In case it is necessary to clean porduct, we recom-