    OSCILLOSCOPES & W AVEFORM ANAL YZERS200 Megasample/Second Digitizing OscilloscopesModels 54200A/D, 54201A/D. Dual 200 megasample/second digitizers,50 MHz single-shot capture. Pre-trigger viewing. Automatic waveform measurements

    HP 54200A/D. Dual 200 megasample/seconddigitizers. 50 MHz bandwidth. Pre-trigger display. Auto-scaling of input signal. Automatic measurementsof waveform parameters. Infinite persistencedisplay, plus envelopeand averagedisplaymodelTbe HP 54200D model adds:. Up to 27 channels of state triggering. Missingbit trinenng mode. Extra bit trinering modeHP 54201A/D. 00 MHz repetitive bandwidth. Dual 200 megasample/seconddigitizers. SOMHz single-shot bandwidth. Pre-trigger display. Auto-scaling of input signal. Automatic measurementsof waveform parameters. Infinite pcrsistencedisplay, plus envelopeand averagedisplaymodelTbc HP 54201D modcl adds:. Up to 27 channels of state triggering. Missing bit triggering mode. Extra it riggering ode

    allowlng Up to 27 channels of state triggeringInfinite variable persistenceInstant hardcopy output300 MHz repetitive bandwidth(HP 54201A/D only)

    ....

    ... .1~-i ~...~,~~~~",

    Simpli" Waveform Capture end AnalysisEasy nstrument Setup. Pressing he Auto-Scale button automatically provides a scaleddisplay of a wide range of input signals.. Save and recall your front panel setups or quick return toprevious measurements.. ECL and TTL preset keys automatically set up vertical range,offset, and trigger levels for viewing digital signals.. Input and memory labels aid in signal and setup dentification.. "Configuration" menu gives nstrument status in a single displayto aid in instrument setup and measurement documentation.. Built-in 50 ohm switchable inputs eliminate the need or extemaltermination devices (HP 54201A/D only).Digital Storage. Bright, fade-free, non-blooming displays.. Waveforms can be stored for comparison or analysis. Storedwaveforms can be displayed concurrently with live waveforms

    and can be output directly to a printer or plotter.. Time/voltage CursoR enable measurementson or between iveand stored waveforms.. Average mode improves signal-to-noise ratio on repetitive signals.. Envelope mode savesmaximum and minimum values of repetitiveevents or wont-case analysis.. Accumulate mode displays multi-valued waveforms.. Connect-the-dots mode aids signal interpretation (HP5420IA/D).

    With compliments

    Helmut Singer Elektronikwww.helmut-singer.de [email protected] +49 241 155 315 fax +49 241 152 066Feldchen 16-24 D-52070 Aachen Germany

  • 7/27/2019 hp54200a_54200d_54201a_54201d

    2/3

    $oecitlcatlonsCh.nnels.nd 2(Vertic8l) HPM200A/D .. 54201A/DAcqulsitlon R~ ~.. :..peC-,;{,B8ndWldth(-3 dB)ck-COUpled dc 50MHz dc 50MHz dc Blitzac

  • 7/27/2019 hp54200a_54200d_54201a_54201d

    3/3

    OSCILLOSCOPES & W AVEFORM ANAL YZERS200 Megasample/Second Digitizing Oscilloscopes (cont'd)Models 54200A/D, 54201A/DStete Trigger Mode(HP 542000 and HP 542010 only)Clock Repetition Re"Single phase: 25 MHz max. with single clock and single edge;20 MHz max. with any ORed combination of clocks and edges.Mul-tiplexed: master/slave clock timing; master clock must follow slaveclock by at least IOns and precede next slave clock by 50 ns or more.Minimum Clock Pulse Wldth: 20 ns at thresholdMinimum Setup Time: 20 ns, the time data must be present beforethe clock transition.Minimum Hold TIme: 0 seconds. be time data mUll be present afterthe clock transition.Probes (HP 10271A)Input RC: 100k :2% shuntcdby -5 pF attbe probebody.Minimum Input: 600 mV peak-to-peakMinimum Input Overdrive: 250 mV or 30% of input amplitude,whichevers greater.Maximum Safe nput YOIt8ge:~ V peakThrelhold R8nge: 9.9 V to +9.9 V in 0.1 V incrementsThrelhold Accur8cy: 2.5% ~120 mVDynamicR8nge: 10 V about hresboldDigitizerDigitizing TechnlqueReal-time digitizing: all data points are acquircd on a single acqui-sition.Random repetitive digitizing (HP 54201A/D): data points are ac-quired on multiple acquisitions.Resolution: 6 bits; 1 part in 64. Effective resolution can be extendedup to -7 bits by using data filtering and averaging.Acqul.ltion Aecord Length: 1001 sampies 1000 intervals).DisplayData Display Formats: one, two, or Courwaveforms can be displaycdat tbe same ime. Tbey can be ive waveforms (channell or 2 display)or stored waveforms (from waveform memoriea 0,1,2, or 3) in anycombination.Display/Store Mode.Normal: tbe display is repetitively updated witb eacb newwaveform acquisition.Accumulate: all successivewaveform acquisitions are displayeduntil erased. Erasure modes are manual, slow (after 64 acquisitions),and fast (after 16 acquisitions).Envelope: provides a display of tbe running maximum and mini-mum voltage at eacb sampie point for a repetitive input waveform.

    Average: provides a display of tbe average voltage at eacb sampIepoint for 4, 16, 64, or 256 user-defined waveform acquisitions. Oneacb acquisition I/n times, tbe new data is added to (n-I)/n of tbeprevious value at eacb time coordinate. Operates in a continuousmode.Connect-The-Dots (HP 54201A/D): provides a display of tbe sam-pie points connected by straigbt lines.MeasurementAidsAutomatie Me..urements: tbe following waveform measurementscan be performed automatically on live or stored waveforms. Tbestandard measurement bresbolds are tbe 10%, 50%, and 90% pointsof tbe waveform. In tbe user-defined mode, voltages, percentages,orECL/TTL presetscan be used to define tbe upper and lower tbresb-aids. Meaaurementsare continuously updated with eacb new acquisi-tion.Frequency Duty CyclePeriod Delay+ Pulse Widtb Delay [Ave], [Max],- Pulse Widtb [Min], [Last] (HP S420IA/D)Rise Time VamplFall Time VmaxVminVrmsSetup AidsAuto-SC8J8: pressing the Auto-Scale key sets the vertical and hori-zontal ranges, offset, and trigger level to display the input signals.Period, positive pulse, negative pulse, rising edge, or falling edge maybe selectedas the horizontal display criterion. Requires a duty cycleof > 1%, frequency > 50 Hz, and amplitude> 20 mV peak. Vertical,horizontal, and trigger auto-scaling functions may be selectively en-abled or disabled. The HP 54201A/D requires a frequency between50 Hz and 200 MHz.Presets: scales he vertical range, offset, and trigger level to predeter-mined values tor displaying ECL or TTL waveforms.Setup Memori..: tour front-panel setups 0 through 3) may be savedin non-volatile memory. Labels may be assianed o each setup.Ordering InformationHP 54200A 50 MHz digitizing oscilloscopeHP 54200D 50 MHz, logic triggering digitizingoscilloscopeHP 54201A 300 MHz digitizing oscilloscopeHP 54201D 300 MHz, logic triggering digitizingoscilJoscope