Top Banner
HP Fibre Channel Mass Storage Adapters Support Guide FibrChanl-01 (fcd) Driver HP-UX 11i v1, 11i v2, and 11i v3 Edition 17 Manufacturing Part Number : J6374-90052 February 2007 Printed in the US © Copyright 2007 Hewlett Packard Development Company L.P.
67

HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Mar 18, 2018

Download

Documents

trinhnguyet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

HP Fibre Channel Mass Storage Adapters Support Guide

FibrChanl-01 (fcd) Driver

HP-UX 11i v1, 11i v2, and 11i v3

Edition 17

Manufacturing Part Number : J6374-90052

February 2007

Printed in the US

© Copyright 2007 Hewlett Packard Development Company L.P.

Page 2: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Legal Notices The information in this document is subject to change without notice.

Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material.

Warranty

A copy of the specific warranty terms applicable to your Hewlett-Packard product and replacement parts can be obtained from your local Sales and Service Office.

U.S. Government License

Proprietary computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license.

Trademark Notices

UNIX is a registered trademark in the United States and other countries, licensed exclusively through The Open Group.

2

Page 3: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Contents

1. Adapter OverviewHP Fibre Channel Mass Storage Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7AD300A PCI-e Dual Port 4 Gb Fibre Channel Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8AB378B PCI-X Single Port 4 Gb Fibre Channel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10AB379B PCI-X Dual Port 4 Gb Fibre Channel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11AB378A PCI-X Single Port 4 Gb Fibre Channel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12AB379A PCI-X Dual Port 4 Gb Fibre Channel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13A6826A PCI-X Dual Port 2 Gb Fibre Channel Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14A9782A Fibre Channel-Ethernet Combination Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15A9784A Fibre Channel-Ethernet Combination Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16AB465A Fibre Channel-Ethernet Combination Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

2. Fibre Channel Adapter InstallationPrerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Installing Driver Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Installing Adapter Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Installing the Fibre Channel Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Attaching the Adapter to Other Fibre Channel Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Verifying the Fibre Channel Adapter Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Verifying Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Interpreting Hardware Paths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

3. Troubleshooting and MaintenanceIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Combination Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Adapter LED States. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36fcmsutil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Reading VPD Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Auto-Speed Negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Device Replacement without System Reboot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

HP Support Tools Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Event Monitoring Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Fibre Channel Adapter Monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Supported Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Installing and Configuring Support Tools Manager and EMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

System requirements: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Offline Diagnostics Environment (ODE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Diagnostic Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Flowchart 1: Configuration Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

Fibre Channel Connections Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Flowchart 2 Connections Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

3

Page 4: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Contents

Flowchart 3: Boot Test Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Firmware Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

Fibre Channel Host Bus Adapter Online Firmware Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Fibre Channel Host Bus Adapters Offline Driver and Firmware Updates . . . . . . . . . . . . . . . . . . . . . 55

Fibre Channel Device Scanning Policy Configuration for HP Integrity Systems . . . . . . . . . . . . . . . . . 56

A. Regulatory StatementsRegulatory Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

FCC Statement (USA Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58IEC Statement (Worldwide) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58DOC Statement (Canada) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Spécification ATI Classe A (France) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58VCCI Statement (Japan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59

Laser Safety Statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Certification and Classification Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

Usage Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Laser Safety (Finland) LASERTURVALLISUUS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

B. Technical SpecificationsA6826A Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62AB378A & AB378B Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63AB379A & AB379B Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

C. Additional FeaturesFibre Channel SNIA HBA API . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66

4

Page 5: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

1 Adapter Overview

This manual contains information about HP Fibre Channel Mass Storage Host Bus Adapters that use the FCD driver. Each adapter is identified along with installation and troubleshooting instructions. This chapter addresses the following topics:

“HP Fibre Channel Mass Storage Overview” on page 7“AD300A PCI-e Dual Port 4 Gb Fibre Channel Adapter” on page 8

Chapter 1 5

Page 6: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter Overview

“AB378B PCI-X Single Port 4 Gb Fibre Channel Adapter” on page 10“AB379B PCI-X Dual Port 4 Gb Fibre Channel Adapter” on page 11“AB378A PCI-X Single Port 4 Gb Fibre Channel Adapter” on page 12“AB379A PCI-X Dual Port 4 Gb Fibre Channel Adapter” on page 13“A6826A PCI-X Dual Port 2 Gb Fibre Channel Adapter” on page 14“A9782A Fibre Channel-Ethernet Combination Card” on page 15“A9784A Fibre Channel-Ethernet Combination Card” on page 16“AB465A Fibre Channel-Ethernet Combination Card” on page 17

Chapter 16

Page 7: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewHP Fibre Channel Mass Storage Overview

HP Fibre Channel Mass Storage Overview

NOTE For the latest copy of this document and related HP Fibre Channel documentation:

1. Go to http://www.docs.hp.com

2. In the “Internet & Networking” category, select “I/O Cards and Networking Software”.

3. Select “Fibre Channel”.

HP Fibre Channel Mass Storage is a high-speed connection for mass storage. It transmits data faster than existing SCSI mass storage interconnects.

HP Fibre Channel Mass Storage networks are ideal for data-intensive applications, including data mining, atmospheric modeling, multimedia, geographic information systems, and medical imaging.

HP Fibre Channel host bus adapters (HBAs) are available for HP/9000 and HP Integrity servers.

For all supported configurations, see the HP Fibre Channel Host Bus Adapter Support Matrix at:http://www.docs.hp.com

Installation steps differ for various systems. Be sure to follow the information in this guide for your adapter. See the system’s documentation for detailed installation procedures and illustrations.

Chapter 1 7

Page 8: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAD300A PCI-e Dual Port 4 Gb Fibre Channel Adapter

AD300A PCI-e Dual Port 4 Gb Fibre Channel AdapterThe AD300A is a dual port 4 Gb-capable adapter that operates in PCI 66 MHz and PCI-e 66 MHz/133 MHz/266 MHz bus speeds with a 64-bit bus width. Both ports support Auto-Speed Negotiation, and are independently capable of 1 Gb, 2 Gb, or 4 Gb data transfer rates. Auto-Speed Negotiation enables each port to automatically negotiate the highest speed common to the port and the infrastructure connecting the port.

Use the fcmsutil diagnostic tool to display link speed and other Vital Product Data (VPD) information.

The AD300A dual port adapter supports Online Addition and Replacement (OLAR) on OLAR-capable systems running HP-UX 11i v2. OLAR refers to the ability of a PCI card to be replaced (removed or added) without shutting down and rebooting the system.

The AD300A dual port adapter supports fabric topologies. The direct attach topology is supported using arbitrated loop topology.

Chapter 18

Page 9: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAD300A PCI-e Dual Port 4 Gb Fibre Channel Adapter

For supported configurations, firmware requirements and information about supported Fibre Channel devices, see the HP Fibre Channel Host Bus Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

Figure 1-1 AD300A PCI-e Dual Port 4 Gb Fibre Channel Adapter

Chapter 1 9

Page 10: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAB378B PCI-X Single Port 4 Gb Fibre Channel Adapter

AB378B PCI-X Single Port 4 Gb Fibre Channel AdapterThe AB378B is a single-port 4 Gb-capable adapter that operates in PCI 33 MHz/66 MHz and PCI-X 66 MHz/133 MHz/266 MHz bus speeds with a 64-bit bus width. The port supports Auto-Speed Negotiation and is capable of 1 Gb, 2 Gb, or 4 Gb data transfer rates. Auto-Speed Negotiation enables each port on the adapter to automatically negotiate the highest speed common to the port and the infrastructure connecting the port.

The AB378B is an updated version of the AB378A, with support for a broader range of servers. It is backward compatible with the AB378A.

Use the fcmsutil diagnostic tool to display link speed and other Vital Product Data (VPD) information.

The AB378B single port adapter supports Online Addition and Replacement (OLAR) on OLAR-capable systems running HP-UX 11i v1 or 11i v2. OLAR refers to the ability of a PCI card to be replaced (removed or added) without shutting down and rebooting the system.

The AB378B single port adapter supports fabric topologies. The direct attach topology is supported using arbitrated loop topology.

Figure 1-2 AB378B PCI-X Single Port 4 Gb Fibre Channel Adapter

For supported configurations, firmware requirements and information about supported Fibre Channel devices, see the HP Fibre Channel Host Bus Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

Chapter 110

Page 11: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAB379B PCI-X Dual Port 4 Gb Fibre Channel Adapter

AB379B PCI-X Dual Port 4 Gb Fibre Channel AdapterThe AB379B is a dual port 4 Gb-capable adapter that operates in PCI 33 MHz/66 MHz and PCI-X 66 MHz/133 MHz/266 MHz bus speeds with a 64-bit bus width. Both ports support Auto-Speed Negotiation, and are independently capable of 1 Gb, 2 Gb, or 4 Gb data transfer rates. Auto-Speed Negotiation enables each port to automatically negotiate the highest speed common to the port and the infrastructure connecting the port.

The AB379B is an updated version of the AB379A, with support for a broader range of servers. It is backward compatible with the AB379A.

Use the fcmsutil diagnostic tool to display link speed and other Vital Product Data (VPD) information.

The AB379B dual port adapter supports Online Addition and Replacement (OLAR) on OLAR-capable systems running HP-UX 11i v1 or 11i v2. OLAR refers to the ability of a PCI card to be replaced (removed or added) without shutting down and rebooting the system.

The AB379B dual port adapter supports fabric topologies. The direct attach topology is supported using arbitrated loop topology.

Figure 1-3 AB379B PCI-X Dual Port 4 Gb Fibre Channel Adapter

For supported configurations, firmware requirements and information about supported Fibre Channel devices, see the HP Fibre Channel Host Bus Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

Chapter 1 11

Page 12: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAB378A PCI-X Single Port 4 Gb Fibre Channel Adapter

AB378A PCI-X Single Port 4 Gb Fibre Channel AdapterThe AB378A is a single-port 4 Gb-capable adapter that operates in PCI 33 MHz/66 MHz and PCI-X 66 MHz/133 MHz/266 MHz bus speeds with a 64-bit bus width. The port supports Auto-Speed Negotiation and is capable of 1 Gb, 2 Gb, or 4 Gb data transfer rates. Auto-Speed Negotiation enables each port on the adapter to automatically negotiate the highest speed common to the port and the infrastructure connecting the port.

Use the fcmsutil diagnostic tool to display link speed and other Vital Product Data (VPD) information.

The AB378A single port adapter supports Online Addition and Replacement (OLAR) on OLAR-capable systems running HP-UX 11i v1 or 11i v2. OLAR refers to the ability of a PCI card to be replaced (removed or added) without shutting down and rebooting the system.

The AB378A single port adapter supports fabric topologies. The direct attach topology is supported using arbitrated loop topology.

Figure 1-4 AB378A PCI-X Single Port 4 Gb Fibre Channel Adapter

For supported configurations, firmware requirements and information about supported Fibre Channel devices, see the HP Fibre Channel Host Bus Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

Chapter 112

Page 13: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAB379A PCI-X Dual Port 4 Gb Fibre Channel Adapter

AB379A PCI-X Dual Port 4 Gb Fibre Channel AdapterThe AB379A is a dual port 4 Gb-capable adapter that operates in PCI 33 MHz/66 MHz and PCI-X 66 MHz/133 MHz/266 MHz bus speeds with a 64-bit bus width. Both ports support Auto-Speed Negotiation, and are independently capable of 1 Gb, 2 Gb, or 4 Gb data transfer rates. Auto-Speed Negotiation enables each port to automatically negotiate the highest speed common to the port and the infrastructure connecting the port.

Use the fcmsutil diagnostic tool to display link speed and other Vital Product Data (VPD) information.

The AB379A dual port adapter supports Online Addition and Replacement (OLAR) on OLAR-capable systems running HP-UX 11i v1 or 11i v2. OLAR refers to the ability of a PCI card to be replaced (removed or added) without shutting down and rebooting the system.

The AB379A dual port adapter supports fabric topologies. The direct attach topology is supported using arbitrated loop topology.

Figure 1-5 AB379A PCI-X Dual Port 4 Gb Fibre Channel Adapter

For supported configurations, firmware requirements and information about supported Fibre Channel devices, see the HP Fibre Channel Host Bus Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

Chapter 1 13

Page 14: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewA6826A PCI-X Dual Port 2 Gb Fibre Channel Adapter

A6826A PCI-X Dual Port 2 Gb Fibre Channel AdapterThe HP A6826A is a dual port 2 Gb-capable adapter that operates in PCI 33 MHz/66 MHz and PCI-X 66 MHz/133 MHz bus speeds with a 64-bit bus width.

Both ports support Auto-Speed Negotiation and are independently capable of a 1 Gb/2 Gb data transfer rate. Auto-Speed Negotiation enables each port on the adapter to automatically negotiate the highest speed common to the port and the infrastructure connecting the port.

Use the fcmsutil diagnostic tool to display link speed and other Vital Product Data (VPD) information.

The A6826A dual port adapter supports Online Addition and Replacement (OLAR) on OLAR-capable systems running HP-UX 11i v1 or 11i v2. OLAR refers to the ability of a PCI card to be replaced (removed or added) without shutting down and rebooting the system.

The A6826A dual port adapter supports arbitrated loop and fabric topologies and is compatible with 1 Gb, 2 Gb and 4 Gb devices.

Figure 1-6 A6826A Dual Port Fibre Channel Adapter

For supported configurations and firmware requirements for the A6826A, see the HP Fibre Channel Host Bus Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

PCI - X

DUAL PORT

2 Gb / 1 Gb

FIBRE

CHANNEL

PORT 1

2 Gb 1 Gb

2 Gb 1 Gb

TX

RX

TX

RX

PORT 2

Chapter 114

Page 15: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewA9782A Fibre Channel-Ethernet Combination Card

A9782A Fibre Channel-Ethernet Combination CardThe HP Fibre Channel component of the HP A9782A Fibre Channel-Ethernet combination card uses the same driver (FibrChanl-01) as the HP A6826A Fibre Channel adapter. All information about the A6826A Fibre Channel adapter also applies to the HP Fibre Channel component of the A9782A Fibre Channel-Ethernet combination card.

For A9782A installation information, see the A9782A & A9784A PCI-X 2 Gigabit Fibre Channel and Gigabit Ethernet Combination Card Installation Guide at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

For Fibre Channel Troubleshooting and Maintenance information, see Chapter 3, “Troubleshooting and Maintenance,” on page 33.

Figure 1-7 A9782A Fibre Channel-Ethernet Combination Card

For supported configurations and firmware requirements specific to the A9782A combination card, see the HP A9782A & A9784A 2 Gigabit Fibre Channel-Gigabit Ethernet Combination Card Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

CH

AN

NE

LA

CT

1Gb

2Gb

FIB

RE

1000B-SX

LIN

K

PC

I-X133 M

Hz

Chapter 1 15

Page 16: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewA9784A Fibre Channel-Ethernet Combination Card

A9784A Fibre Channel-Ethernet Combination CardThe HP Fibre Channel component of the HP A9784A Fibre Channel-Ethernet combination card uses the same driver (FibrChanl-01) as the HP A6826A Fibre Channel adapter. All information about the A6826A Fibre Channel adapter also applies to the HP Fibre Channel component of the A9784A Fibre Channel-Ethernet combination card.

For A9784A installation information see the A9782A & A9784A PCI-X 2 Gigabit Fibre Channel and Gigabit Ethernet Combination Card Installation Guide at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

For Fibre Channel Troubleshooting and Maintenance information, see Chapter 3, “Troubleshooting and Maintenance,” on page 33.

Figure 1-8 A9784A Fibre Channel-Ethernet Combination Card

For supported configurations and firmware requirements specific to the A9784A combination card, see the HP A9782A & A9784A 2 Gigabit Fibre Channel-Gigabit Ethernet Combination Card Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

CH

AN

NE

L1G

b2G

b

FIB

RE

1000B-T

LN

K/A

CT

PC

I-X133 M

Hz

100010010

Chapter 116

Page 17: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAB465A Fibre Channel-Ethernet Combination Card

AB465A Fibre Channel-Ethernet Combination CardThe HP Fibre Channel component of the HP AB465A Fibre Channel-Ethernet combination card uses the same driver (FibrChanl-01) as the HP A6826A Fibre Channel adapter. It operates in PCI 66 MHz and PCI-X 66 MHz / 133 MHz bus speeds with a 32-bit or 64-bit bus width. It operates in 3.3V slots only.

For AB465A installation information see the AB465A PCI-X 2-Port 2 Gigabit Fibre Channel and 2-Port Gigabit Ethernet Combination Card Installation Guide at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

For Fibre Channel Troubleshooting and Maintenance information, see Chapter 3, “Troubleshooting and Maintenance,” on page 33.

Figure 1-9 AB465A Fibre Channel-Ethernet Combination Card

For supported configurations and firmware requirements specific to the A9784A combination card, see the HP AB465A Combination Fibre Channel / Gigabit Ethernet Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

PC

I-X133 M

Hz

Chapter 1 17

Page 18: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Adapter OverviewAB465A Fibre Channel-Ethernet Combination Card

Chapter 118

Page 19: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

2 Fibre Channel Adapter Installation

This chapter contains installation prerequisites, guidelines, and procedures for each host bus adapter. This chapter addresses the following topics:

“Prerequisites” on page 21“Installing Driver Software” on page 22“Installing Adapter Hardware” on page 24

Chapter 2 19

Page 20: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter Installation

“Attaching the Adapter to Other Fibre Channel Devices” on page 26“Verifying the Fibre Channel Adapter Installation” on page 28“Verifying Connectivity” on page 29“Interpreting Hardware Paths” on page 30

Chapter 220

Page 21: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationPrerequisites

PrerequisitesBefore installing the adapter, follow these steps:

Step 1. Verify compliance with supported configurations using the HP Fibre Channel Host Bus Adapter Support Matrix at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

Step 2. Determine if the adapter is a Customer Replaceable Unit (CRU) using the HP Fibre Channel Host Bus Adapter Support Matrix. If the adapter is not a CRU, contact your HP representative for installation assistance.

Field Replaceable Units (FRUs) must be installed or replaced by qualified Hewlett-Packard service representatives only. CRUs can be installed or replaced by customers or qualified Hewlett-Packard service representatives.

Step 3. Check the following conditions:

• To verify that the /usr/bin, /usr/sbin, and /sbin directories are in the PATH, enter the following command:

echo $PATH

• Verify that you have the following items:

— Grounding wrist strap

— Fibre Channel driver software media (included with the OS or application CD)

— Fibre Channel host bus adapter with an optical port protector attached (not included with all adapters)

• Verify that you have the following cabling items:

— Fiber optic cable terminated with a duplex LC connector.

— Cable map (optional)

Chapter 2 21

Page 22: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationInstalling Driver Software

Installing Driver SoftwareThese instructions apply to software installation for the following configurations:

• AD300A Fibre Channel Adapter with HP-UX 11i v2• AB378A Fibre Channel Adapter with HP-UX 11i v1 - 11i v2• AB379A Fibre Channel Adapter with HP-UX 11i v1 - 11i v2• AB378B Fibre Channel Adapter with HP-UX 11i v1 - 11i v2• AB379B Fibre Channel Adapter with HP-UX 11i v1 - 11i v2• A6826A Fibre Channel Adapter with HP-UX 11i v1 - 11i v2• A9782A Fibre Channel Adapter with HP-UX 11i v1 - 11i v2• A9784A Fibre Channel Adapter with HP-UX 11i v1 - 11i v2• AB465A Fibre Channel Adapter with HP-UX 11i v1 - 11i v2

Table 2-1 on page 22 lists the bundle and product name for each adapter.

To install the software bundle, follow these steps:

Step 1. Log in to the system as root.

Step 2. Insert the CD into the CD drive.

Step 3. Mount the CD using the following command:

mount /dev/dsk/<cd_rom_dev_file> /<tmp_mnt>

Step 4. Run swinstall to install the software. Enter the following command:

/usr/sbin/swinstall

The Software Selection window and the Specify Source window open.

Step 5. In the Specify Source window, change the Source Host Name if necessary. Enter the mount point of the drive in the Source Depot Path field and click OK to return to the Software Selection window.

Table 2-1

Adapter OS Version

Software Bundle Software Name Driver

AD300A 11i v2 only FibrChanl-01 FC-FCD fcd

AB378AAB378B

11i v2

11i v3

FibrChanl-01 FC-FCD fcd

AB379AAB379B

11i v2

11i v3

FibrChanl-01 FC-FCD fcd

A6826A 11i v1 FibrChanl-01 FC-FCD fcd

A9782AA9784A

11i v2

11i v3

FibrChanl-01 FC-FCD fcd

AB465A 11i v2

11i v3

FibrChanl-01 FC-FCD fcd

Chapter 222

Page 23: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationInstalling Driver Software

Click Help to get more information.

Step 6. Select the appropriate software bundle for your adapter.

Step 7. Select Mark for Install from the Actions menu.

Step 8. Select Install from the Actions menu. Installation begins and the Install Analysis window opens.

Step 9. Click OK in the Install Analysis window to confirm that you want to install the software. The Install window opens.

View the Install window to read processing data while the software installs. When the Status field indicates Ready, the Confirmation window opens.

Step 10. Click OK. A second Confirmation window opens.

Step 11. Click OK again. The Install window opens.

Step 12. Click Done. The Note window opens.

Step 13. Click OK in the Note window to reboot. The user interface disappears and the system reboots.

Step 14. Once the system comes back up, log in as root and open the following files to see any error or warning messages that may have occurred during the installation:

/var/adm/sw/swagent.log

/var/adm/sw/swinstall.log

Step 15. Install OnlineDiag, which is available at http://www.software.hp.com. OnlineDiag is also available from the HP Support PLUS CD. Installation instructions are available at: http://docs.hp.com/hpux/onlinedocs/diag/st/st_inst.htm

Chapter 2 23

Page 24: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationInstalling Adapter Hardware

Installing Adapter Hardware

The Online Addition and Replacement feature, OLAR for HP-UX 11i v3, or OL* for HP-UX 11i v2 and later HP-UX releases, enables PCI host bus adapters to be added or replaced without shutting down and rebooting the system, and without adversely affecting other system components. The system hardware uses slot-specific power control, combined with HP-UX operating system support, to enable these features.

Confirm whether OLAR or OL* are supported on the system in wich you plan to install a Fibre Channel adapter. See the HP Fibre Channel Host Bus Adapter Support Matrix, at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

For detailed instructions on using OLAR on HP-UX 11i v3, see Chapter 2 of Configuring HP-UX for Peripherals, which can be accessed at:http://docs.hp.com/en/hpux11i.html

For detailed instructions on using OL* on HP-UX 11i v2 and later HP-UX releases, see the Interface Card OL* Support Guide and the Interface Card OL* Support Matrix at: http://docs.hp.com/en/hpux11iv2.html

NOTE HP rp54xx servers have slot restrictions for OLAR.

PCI slots 1 through 4 do not support OLAR. In these servers, use PCI slots 5 through 12 for OLAR.

IMPORTANT Superdome systems are not intended to be maintained by customers. HP recommends that Superdome systems only be opened by a qualified HP service engineer. Failure to observe this recommendation can invalidate any support agreement or warranty to which you may be entitled.

Table 2-2 summarizes the PCI slot numbers that are compatible with Online Addition and Replacement for select HP server products.

Table 2-2 OLAR-compatible PCI Slot Numbers

Server Name Product Number Supported Slots

L1000 A5576A 8, 10, 12

L2000 A5191A 3, 4, 5, 6, 8, 10, 12

N4000 Rev. A A3639A 2, 4, 6, 8, 10, 12

N4000 Rev. B A3639B 2, 4, 6, 8, 10, 12

N4000 Rev. C A3639C If upgraded from A3639A or A3639B

2, 4, 6, 8, 10, 12

Chapter 224

Page 25: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationInstalling Adapter Hardware

Installing the Fibre Channel Adapter

CAUTION Observe all ESD safety precautions before attempting this procedure. Failure to follow ESD safety precautions could result in damage to equipment.

NOTE The optical port protector is used only to protect the adapter port when it is not in use. Do not use the protector as a diagnostic tool.

Install OnlineDiag, which is available at: http://www.software.hp.com

OnlineDiag is also available from the HP Support PLUS CD for HP/9000 systems or the IPFxxxx CD for Itanium systems. Installation instructions are available at:http://docs.hp.com/hpux/onlinedocs/diag/st/st_inst.htm

Install all driver software and dependent patches before you install the adapter. For more information, see FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes available at: http://docs.hp.com/en/netcom.html#Fibre%20Channel

NOTE See the system documentation for information about how to safely shut down your system and obtain access to expansion slots.

To install the Fibre Channel adapter, follow these steps:

Step 1. Install all driver software and dependent patches.

Step 2. Shut down the system.

Step 3. Install the adapter in an available PCIe slot.

Step 4. Attach fiber cabling to the adapter. All Fibre Channel host bus adapters that use the FCD driver use a cable terminated with an LC connector.

Chapter 2 25

Page 26: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationAttaching the Adapter to Other Fibre Channel Devices

Attaching the Adapter to Other Fibre Channel DevicesTo attach the adapter to other Fibre Channel devices, follow these steps:

1. Remove the Fibre Channel host bus adapter’s optical port protector (if included).

2. Attach a connector cable to the Fibre Channel host bus adapter.

a. Align the slotted plug with the keyed connector.

b. Push the connector in until you hear it click.

3. Attach the free end of the cable to a compatible Fibre Channel device.

4. Reconnect the power cord, if necessary, and power on the system.

Table 2-3 lists the Fibre Channel cables that you can use when connecting devices to Fibre Channel host bus adapters.

NOTE Be sure to use LC-LC or LC-SC cables for the Fibre Channel host bus adapters which use the FCD driver.

Table 2-3 Multimode Fibre Channel Cables

Product Type

Product Number Length Fibre Width Duplexing

SC-SC A3583A 2M 50uM/125uM no

A3531A 16M

A3735A 50M

A3736A 100M

LC-LC C7524A 2M yes

C7525A 16M

C7526A 50M

C7527A 100M

LC-SC C7529A 2M

C7530A 16M

Chapter 226

Page 27: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationAttaching the Adapter to Other Fibre Channel Devices

Table 2-4 lists the cable adapter products that you can use when connecting devices to Fibre Channel host bus adapters.

Table 2-4 Cable Adapter Products

Product Number Product Name Description

C7534A Fibre Channel Adapter SC F/F

C7540A Fibre Channel Adapter Kit Includes 2M LC/SC Cable and F/F extenders

Chapter 2 27

Page 28: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationVerifying the Fibre Channel Adapter Installation

Verifying the Fibre Channel Adapter InstallationTo verify that your Fibre Channel Adapter has been correctly installed, follow these steps:

Step 1. Enter the following command:

ioscan -f

Step 2. Verify that the correct drivers appear for each installed adapter. If all drivers display, proceed to the next section, “Verifying Connectivity” on page 29.

Sample ioscan output:

fc 0 0/0/2/1/0 fcd CLAIMED INTERFACE HP AB379-60001 4Gb Dual Port PCI/PCI-X Fibre Channel Adapter (FC Port 1) /dev/fcd0fc 1 0/0/2/1/1 fcd CLAIMED INTERFACE HP AB379-60001 4Gb Dual Port PCI/PCI-X Fibre Channel Adapter (FC Port 2) /dev/fcd1fcp 0 0/0/2/1/1.97 fcd_fcp CLAIMED INTERFACE FCP Domainext_bus 2 0/0/2/1/1.97.5.19.0 fcd_vbus CLAIMED INTERFACE FCP Array Interfacetarget 11 0/0/2/1/1.97.5.19.0.0 tgt CLAIMED DEVICEdisk 11 0/0/2/1/1.97.5.19.0.0.0 sdisk CLAIMED DEVICE HP OPEN-9 /dev/dsk/c2t0d0 /dev/rdsk/c2t0d0disk 14 0/0/2/1/1.97.5.19.0.0.1 sdisk CLAIMED DEVICE HP OPEN-9 /dev/dsk/c2t0d1 /dev/rdsk/c2t0d1disk 18 0/0/2/1/1.97.5.19.0.0.2 sdisk CLAIMED DEVICE HP OPEN-9 /dev/dsk/c2t0d2 /dev/rdsk/c2t0d2disk 21 0/0/2/1/1.97.5.19.0.0.3 sdisk CLAIMED DEVICE HP OPEN-9 /dev/dsk/c2t0d3 /dev/rdsk/c2t0d3

NOTE The third column represents the hardware path of the slot in which the adapter is installed. The hardware path is different for each installed adapter.

If an installed Fibre Channel adapter requires the fcd driver and the appropriate driver does not appear as shown above, the driver is not installed.

If the ioscan output is similar to the following:

fc 0/0/2/1/0 UNCLAIMED UNKNOWN

HP-UX detected the adapter, but the drivers are not properly loaded.

If the correct driver is installed, but the adapter does not show in the ioscan output, the driver is not recognizing the adapter.

Step 3. If the ioscan output indicates a problem, contact HP for assistance.

Chapter 228

Page 29: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationVerifying Connectivity

Verifying ConnectivityOnce your HP Fibre Channel Mass Storage software and hardware is installed and running, follow these steps to verify connectivity:

Step 1. Check the state of all Fibre Channel hardware and interfaces. Enter the ioscan command and verify that the Hardware State and the HW-Interface State are CLAIMED.

If the Fibre Channel device file has not been created, enter the following commands:

# insf -e

# ioscan -f

Step 2. Verify that all devices you attached to the Fibre Channel adapter are listed in the ioscan output. For example, if you have a direct attach Fibre Channel device attached to the system, the ioscan output may look like the following:

8/12.8.0.255.0.1.0 sdisk CLAIMED DEVICE DGC C3400WDR5

The example above is the hardware path of LUN0 of a directly attached Fibre Channel Mass Storage device with Loop ID of 1. For details on interpreting hardware paths for Fibre Channel devices, see “Interpreting Hardware Paths” on page 30.

If all attached devices are not listed or appear as UNCLAIMED, see the Troubleshooting and Maintenance chapter of the HP Fibre Channel Adapters Support Guide.

Chapter 2 29

Page 30: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationInterpreting Hardware Paths

Interpreting Hardware PathsExample 2-1, Example 2-2 and Example 2-3 illustrate the Fibre Channel hardware path format:

Example 2-1 Hardware Path for a Public Loop Device

Example 2-2 Hardware Path for a Direct Fabric Attach Device

Example 2-3 Hardware Path for a Private Loop Device

Table 2-5 describes each field in the hardware path.

Table 2-5 Hardware Path Field Descriptions

Field ValueFibre Channel Topology of HBA

Fabric Topologies Private Loop

Adapter The hardware path of the Fibre Channel adapter through which the Logical Unit Number (LUN) is seen. For multiport adapters, this field describes a specific port on the adapter.

Domain Dependent on the Fibre Channel topology of the HBA.

Typically the Domain ID of the switch to which the target device is attached, taken from the most significant byte of the N_Port ID of the target device.

8

HP-UX uses a Domain ID of 8 to indicate private loops. Fibre Channel switches seen by HP-UX hosts cannot be configured with domain ID of 8.

Adapter Area Port Bus Target LUNDomain

0/1/2/0.1.19.255.15.4.0

Adapter Area Port Bus Target LUNDomain

0/1/2/0.1.19.255.0.0.0

Adapter Area Port Bus Target LUNDomain

0/1/2/0.8.0.255.0.1.0

Chapter 230

Page 31: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationInterpreting Hardware Paths

Area Depends on the Fibre Channel topology of the HBA.

Taken from the second byte of the N_Port ID of the target device.

On some switches, the second byte of the N_Port ID encodes the switch port to which the device is connected. The encoding method depends on the switch. See your switch manual to interpret this field.

0

Port Depends on the Fibre Channel topology of the HBA and the target device, and on the LUN addressing method used.

For LUNs with Peripheral Device Addressing, the value of this field is always 255.

For other LUN methods, the value of this field is the least significant byte of the N_Port ID of the target device.

For other LUN methods, the value of this field is the Loop ID of the target device.

Bus Depends on the Fibre Channel topology of the HBA and the target device, and on the LUN addressing method used.

For LUNs with Peripheral Device Addressing, the value of this field is the upper 4 bits of the least significant byte of the N_Port ID of the target device.

For LUNs with Peripheral Device Addressing, the value of this field is the upper 4-bits of the Loop ID of the target device.

For LUNs with Logical Unit Addressing, the value is the Bus Number field of the LUN.

For LUNs with Volume Set Addressing (Flat Space Addressing), the value is bits 7 - 13 of the LUN.

Target Depends on the Fibre Channel topology and the LUN addressing method used.

For LUNs with Peripheral Device Addressing, the value of this field is the lower 4-bits of the third byte of the N_Port ID of the target device.

This field usually corresponds to the Arbitrated Loop Physical Address (AL_PA) of the target device.

With Peripheral Device Addressing, the value of this field is the lower 4-bits of the Loop ID of the target device.

For LUNs with Logical Unit Addressing, the value is the Target field of the LUN.

For LUNs with Volume Set Addressing (Flat Space Addressing), the value is bits 3 - 6 of the LUN.

LUN Depends only on the LUN addressing method used.

Table 2-5 Hardware Path Field Descriptions (Continued)

Field ValueFibre Channel Topology of HBA

Fabric Topologies Private Loop

Chapter 2 31

Page 32: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Fibre Channel Adapter InstallationInterpreting Hardware Paths

LUN Addressing Method Value of LUN field in Fibre Channel hardwarePath.

Peripheral Device Addressing The Target or LUN field of the Logical Unit Number.

Logical Unit Addressing The LUN field of the Logical Unit Number.

Volume Set Addressing (Flat Space Addressing) Bits 0 - 2 of the Logical Unit Number.

For more information about the fields in the Logical Unit Number, please see the SCSI Architecture Model - 3 (SAM-3) standards document.

Fibre Channel devices can connect to a fabric using either Direct Fabric Attach or Public Loop. Different devices can have different types of connections to the same fabric; for example, an HBA can have a Direct Fabric Attach connection to the fabric, while an array has a Public Loop connection to the same fabric.

Public Loop devices have an Arbitrated Loop Physical Address (AL_PA). The AL_PA usually appears in the least significant byte of the device's N_Port ID. Direct Fabric Attach devices do not have an AL_PA and the least significant byte of their N_Port ID is usually 0. This is dependent on the switch implementation. Not all switches adhere to this scheme.

Some switches enable devices in Private Loop mode to connect to a fabric. These switches typically translate the Private Loop device as either a Public Loop or Direct Fabric Attach device to the rest of the fabric. These switches also typically translate the rest of the fabric as Private Loop devices to the Private Loop device.

Chapter 232

Page 33: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

3 Troubleshooting and Maintenance

This chapter describes the troubleshooting and maintenance tools available for Fibre Channel Mass Storage adapters. This chapter addresses the following topics:

“Introduction” on page 35“Adapter LED States” on page 36“fcmsutil” on page 37

Chapter 3 33

Page 34: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and Maintenance

“HP Support Tools Manager” on page 42“Event Monitoring Service” on page 44“Offline Diagnostics Environment (ODE)” on page 46“Diagnostic Flowcharts” on page 47“Firmware Updates” on page 54“Fibre Channel Device Scanning Policy Configuration for HP Integrity Systems” on page 56

Chapter 334

Page 35: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceIntroduction

IntroductionTroubleshooting Fibre Channel problems can involve a variety of hardware and software components. A problem affecting the system may originate in another part of the Fibre Channel Mass Storage interconnect. If you cannot solve the problem on your own, contact your HP representative.

Combination Cards

The Fibre Channel component of the HP A9782A, A9784A, and AB465A Fibre Channel-Ethernet combination cards use the same driver (FibrChanl-01) as the HP A6826A Fibre Channel adapter. The information that pertains to the A6826A Fibre Channel adapter also applies to the Fibre Channel component of the A9782A and A9784A Fibre Channel-Ethernet combination cards.

For additional information on HP Fibre Channel-Ethernet combination cards, see the Combination Card documentation at:http://docs.hp.com/en/netcom.html#Combination%20Cards

Chapter 3 35

Page 36: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceAdapter LED States

Adapter LED StatesThe Fibre Channel Mass Storage Adapter status LEDs indicate the state of the adapter. Table 3-1 and Table 3-2 list the different LED states for each adapter.

Table 3-1 A6826A LED States

2 Gb Link (Green)

1 Gb Link (Amber) Probable Cause Recommended

Action

Off Off System is not powered on. Power on the system

On On Power On, before firmware initialization

No action is required.

1 flash/second, simultaneous with amber LED

1 flash/second, simultaneous with green LED

Power On, after firmware initialization

No action is required.

2 flashes/second, alternate with amber LED

2 flashes/second, alternate with green LED

Firmware fault Contact HP for assistance.

Off On 1 Gb link-up No action is required.

On Off 2 Gb link-up No action is required.

Off 5 Flash/second Activity on 1 Gb link No action is required.

5 Flash/second Off Activity on 2 Gb link No action is required.

Table 3-2 AB378A, AB378B, AB379A & AB379B LED States

4 Gbps Link (Yellow)

2 Gbps Link (Green)

1 Gbps Link (Amber) Probable Cause Recommended

Action

Off Off Off Power off Power on the system.

On On On Power on (before firmware initialization)

No action is required.

1 flash/second 1 flash/second 1 flash/second Power on (after firmware initialization)

No action is required.

2 flashes/second 2 flashes/second 2 flashes/second Firmware Fault No action is required.

Off Off On, blinking 1 Gb Link UP/ACT

No action is required.

Chapter 336

Page 37: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and Maintenancefcmsutil

fcmsutilUse the fcmsutil command-line diagnostic tool with the following host bus adapters:

• AD300A• AB378B• AB379B• AB378A• AB379A• A6826A• A9782A• A9784A• AB465A

Use the fcmsutil command to perform test and echo functions, read card registers, and display information such as the N_Port ID, Node World-Wide Name, Port World-Wide Name, link speed, chip revision number, Vital Product Data (VPD) information and more. When you use fcmsutil with dual port adapters, each port is accessed and configured independently through the appropriate device driver.

CAUTION The fcmsutil command is a powerful diagnostic tool that can cause problems if used incorrectly. Read and understand the manpage carefully before using fcmsutil.

The primary fcmsutil options for system administrators are:

• echo• test• reset• get

For detailed information on this utility and its options, see the fcmsutil manpage.

To use fcmsutil, you must know the device file name. Enter the following command to determine the device file:

ioscan -fknd fcd

The output varies depending on the device. A sample follows:

fc 1 1/0/2/1/1 fcd CLAIMED INTERFACE HP AB379-60001 4Gb Dual Port PCI/PCI-X Fibre Channel Adapter (FC Port 2)

Off On, blinking Off 2 Gb Link UP/ACT

Contact HP for assistance.

On, blinking Off Off 4 Gb Link UP/ACT

No action is required.

3 flashes/second 3 flashes/second 3 flashes/second Beacon. No action is required.

Table 3-2 AB378A, AB378B, AB379A & AB379B LED States (Continued)

4 Gbps Link (Yellow)

2 Gbps Link (Green)

1 Gbps Link (Amber) Probable Cause Recommended

Action

Chapter 3 37

Page 38: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and Maintenancefcmsutil

/dev/fcd1

If the device file does not display in the ioscan output, run /sbin/rc2.d/S900hpfcms start to recreate the device file.

To use the basic fcmsutil command, enter the following command:

/opt/fcms/bin/fcmsutil /dev/<device_filename>

If you use fcmsutil with dual port universal adapter A6826A, enter the following command:

fcmsutil /dev/fcdx

where:

x is the number assigned to the adapter port being accessed.

The output is similar to the following example:

Vendor ID is = 0x001077 Device ID is = 0x002312 PCI Sub-system Vendor ID is = 0x00103c PCI Sub-system ID is = 0x0012ba PCI Mode = PCI-X 66 MHZ ISP Code version = 3.2.26 ISP Chip Version = 3 Topology = PTTOPT_FABRIC Link Speed = 1Gb Local N_Port_id is = 0x211413 Previous N-Port_id is = None N_Port Node World Wide Name = 0x50060b00001d21fd N_Port Port World Wide Name = 0x50060b00001d21fc Switch Port World Wide Name = 0x2014080088404800 Switch Node World Wide Name = 0x1000080088404800 Driver state = ONLINE Hardware Path is = 0/4/1/0 Maximum Frame Size = 2048 Driver-Firmware Dump Available = NO Driver-Firmware Dump Timestamp = N/A Driver Version = @(#) libfcd.a HP FibreChannel ISP 23xx Driver B.11.11.02/ux/kern/kisu/FCD/src/common/wsio/fcd_init.c:Feb 19 2004,17:46:19**********************************************************

Check to see that the driver state is ONLINE.

You cannot use all fcmsutil options with all the adapters. In the manpage for fcmsutil, (QL) follows the options that can be used with the FibreChannel port of the A6826A, A9782A, A9784A, AB378A, AB379A, and AB465A adapters. Options without the (QL) indicator can be used with all adapters.

You can the echo, test, reset, and get options with fcmsutil. Use other fcmsutil options only at the request of your HP support representative.

Reading VPD Information

You can use fcmsutil with Fibre Channel Host Bus Adapters to read Vital Product Data (VPD) information on the adapter, which can be useful in troubleshooting problems remotely. The command for retrieving VPD information is as follows:

Chapter 338

Page 39: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and Maintenancefcmsutil

fcmsutil <device_filename> vpd

Example 3-1 shows the VPD information from an A6826A adapter:

Example 3-1 Sample VPD information, A6826A Adapter

V I T A L P R O D U C T D A T A --------- ------------- -------

Product Description :’Dual Port 2Gbps/1Gbps Fibre Channel Universal PCI-X Adapter’

Part number :’A6826-60001’

Engineering Date Code :’X-4306’

Part Serial number :’US00000066’

Misc. Information :’PW=15W;PCI 66MHZ;PCI-X 133MHZ’

Mfd. Date :’4306’ Check Sum :’0x52’

EFI version :’001.30’

ROM Firmware version :’03.02.168’

Asset Tag :’NA’

Example 3-2 shows the VPD information from an AB378A adapter:

Example 3-2 Sample VPD information, AB378A Adapter

V I T A L P R O D U C T D A T A --------- ------------- -------

Product Description : HP PCI-X 2.0 4Gb Fibre Channel HBA

Part number : AB378-60001

Engineering Date Code : X-4532

Part Serial number : JW45370268

Misc. Information : PW=15W;PCI=66MHZ;PCI-X=266MHZ

Mfd. Date : 4537

Mfd. ID : AB378-60001

Check Sum : 0x4d

EFI version : 01.01

ROM Firmware version : 04.00.70

Chapter 3 39

Page 40: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and Maintenancefcmsutil

BIOS version : 01.04

FCODE version : 01.08

Asset Tag : NA

Example 3-3 shows the VPD information from the AB379A:

Example 3-3 Sample VPD information, AB379A Adapter

#fcmsutil /dev/fcd1 vpd

V I T A L P R O D U C T D A T A

--------- ------------- -------

Product Description : HP PCI-X 2.0 Dual Port 4Gb Fibre Channel HBA

Part number : AB379-60001

Engineering Date Code : A-4602

Part Serial number : US00016362

Misc. Information : PW=15W;PCI=66MHZ;PCI-X=266MHZ

Mfd. Date : 4602

Mfd. ID : FC2410401-10 04

Check Sum : 0xc5

EFI version : 01.01

ROM Firmware version : 04.00.70

BIOS version : 01.06

FCODE version : 01.12

Asset Tag : NA

Auto-Speed Negotiation

The A6826A, A9782A, A9784A and AB465A adapters are capable of transferring data at 1 Gb or 2 Gb per second. The AB378A, AB378B, AB379A, and AB379B are capable of 1 Gb, 2 Gb or 4 Gb per second. The adapters automatically negotiate to find the highest speed common to the port and the infrastructure connecting the port. Each port on dual port adapters negotiates speed independently.

To display the link speed along with other existing adapter information, enter the following command:

fcmsutil <device_filename>

Once the adapter has negotiated a transfer speed, it does not attempt to negotiate again unless a link fails or it detects a chip reset.

Device Replacement without System Reboot

The fcmsutil <device_file> replace_dsk <remote-N-Port-ID> command described in this section enables target device replacement without a system reboot. This command is available for Fibre Channel adapters or Fibre Channel combination cards that use the fcd driver, including the following:

Chapter 340

Page 41: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and Maintenancefcmsutil

• AD300A• AB378B• AB379B• AB378A• AB379A• A6826A• A9782A• A9784A• AB465A

For more information on this command, see the fcmsutil (1M) manpage.

When the fcd driver discovers a new target device, it creates a hardware path for that device based on the N_Port ID. The N_Port ID is the Fibre Channel address for a device, and a way of identifying the device in a Storage Area Network (SAN). The fcd driver will also associate a device’s World Wide Name (WWN) with its N_Port ID.

Each time the fcd driver opens a target device at an N_Port ID, it compares the WWN for the target device to the WWN of the driver associated with the N_Port ID for that device, when the device was discovered. If the WWNs are not the same, the fcd driver logs an error message and does not allow access to that device. This prevents data corruption if a target device is connected through an N_Port ID that belongs to a different target device; for example, if two JBODs are plugged into each other’s switch ports by mistake.

If you want to intentionally replace a target device, for example a bad disk, use the fcmsutil <device_file> replace_dsk <remote-N-Port-ID> command to force the fcd driver to recognize a new target device at an N_Port ID that was previously used by a different target device. The replace_dsk command replaces the device WWN that is currently associated with a particular N_Port ID with the WWN of the device that is actually connected through that N_Port ID at the time the replace_dsk command is executed.

The association between a target device WWN and an N_Port ID persists until the system is rebooted, or the fcmsutil <device_file> replace_dsk <remote-N-Port-ID> command is executed for that N_Port ID.

Chapter 3 41

Page 42: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceHP Support Tools Manager

HP Support Tools ManagerThis section describes how to use HP Support Tools Manager (STM) to gather information about the Fibre Channel adapters, diagnose problems, and update firmware.

STM runs in three modes:

• Menu Mode

Use the mstm command to start STM in Menu Mode.

• X Windows environment

Use the xstm & command to start STM in X Windows.

• Command Line Mode

Use the cstm command to start STM in Command Line Mode.

Three tools are available in STM for Fibre Channel Mass Storage adapters:

• Information Tool

The Information Tool provides information about a Fibre Channel adapter without resetting the adapter. The following is an example information log for a K-class system:

Log creation time: Tue Jun 6 14:12:23 2000

Hardware path: 8/12

Product ID: Fibre Channel InterfaceHardware Path: 8/12Module Type: Type-A DMA I/OHardware Model: 0x15Hardware Revision Number: 0Software Revision Number: 0Software Model Number: 0xa7Software Option: 0x80Hard Physical Address: 0xffb4c000Slot Number: 3IODC Revision: 0World Wide Name: 1000080009F64883Date Code: 3822

• Logtool Utility

The Logtool Utility extracts log errors and enables you to view them. This tool provides information about a Fibre Channel adapter without resetting the adapter. The following is an example utility log for a K-class system:

Log creation time: Mon Sep 11 17:47:07 2000

Device Path : 8/12

Product ID: Fibre Channel InterfaceProduct Qualifier: 15Logger: tdDevice Type: InterfaceDevice Qualifier: Fibre

Chapter 342

Page 43: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceHP Support Tools Manager

-----------------------------------------------------------Severity Level: Error1Bolt Value: 88417

Error 17: The Fibre Channel Driver received a LINK DOWN interrupt.

Additional Information: Frame Manager Status Register = 0x1 Received AL_PA Register = 0x2 Loss of Signal Counter = 3 Bad Received Character Count = 4 Loss of Synchronization Count = 5 Link Failure Count = 6 Received EOF Count = 9 Generated EOF Count = 8 Bad CRC Count = 9 Protocol Error Count = 10

Possible Causes/Recommended Actions: It is possible for link down errors to occur under normal operation. No action is required. The system will recover.

• Diagnose Tool

The Diagnose Tool runs a loopback test on a Fibre Channel adapter. This test is destructive and must only be run by qualified personnel or on instruction from an HP Support Representative.

NOTE STM also includes a Firmware Update tool. This tool cannot be used to update the firmware on Fibre Channel adapters.

The rom_fw_update option within the fcmsutil command can be used to update the firmware on A6826A, A9782A, A9784A, AB465A, AB378A, AB378B, AB379A, AB379B, and AD300A adapters.

Chapter 3 43

Page 44: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceEvent Monitoring Service

Event Monitoring ServiceEvent Monitoring Service (EMS) notifies you when an event occurs on the system.

A hardware event monitor monitors the hardware for unusual behavior (known as an event) and sends a message to the EMS, which notifies you of the event and provides suggestions for correcting the problem. This service is available for all of the Fibre Channel host bus adapters.

Fibre Channel Adapter Monitor

The Fibre Channel Adapter Monitor monitors the operation of all supported fibre channel host bus adapter cards on your system. If the monitor detects a problem with any of the adapters, it immediately sends an event to EMS, which alerts you using the notification methods defined for the monitor. Error messages identify the problem, its cause, and corrective actions.

The Fibre Channel Adapter Monitor employs asynchronous event detection. The monitor continuously checks for any errors or abnormal behavior reported by the device driver during I/O operations. If an error occurs, it passes directly to the monitor for immediate analysis. If the error warrants notification, the monitor immediately generates an event.

The monitor launches automatically when the system starts, ensuring protection for all supported Fibre Channel adapters from undetected hardware failure.

Supported Products

The Fibre Channel Adapter Monitor supports the following products:

• AD300A• AB378B• AB379B• AB378A• AB379A• A6826A• A9782A• A9784A• AB465A

Installing and Configuring Support Tools Manager and EMS

System requirements:

• HP-UX computer (servers or workstations)

• HP-UX 11i v1, 11i v2, 11i v3, or later HP-UX operating system versions

• Support Plus Media CD

• If you are using ServiceGuard (optional), check for the correct version you must have for HP-UX 11i v1, 11i v2 or later HP-UX operating system versions

Chapter 344

Page 45: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceEvent Monitoring Service

Procedure

Step 1. Install the Support Tools Manager (STM) from the latest Support Plus Media CD. The EMS hardware monitors automatically install when you install STM.

a. Enter the following command to see if STM is installed on your system:/usr/sbin/cstm

The message --Information-- Support Tools Manager should appear on your screen, indicating that STM is installed on your system.

b. If this does not appear, STM needs to be installed. For instructions on how to install STM see Chapter 5, “Using the Support Plus Media to Install Diagnostics”, in the manual Support Plus: Diagnostics User's Guide, available at:http://docs.hp.com/diag/index.html

Step 2. Examine the list of supported products to see if any of your devices have special requirements to be monitored.

Step 3. Add or modify monitoring requests to customize the monitoring configuration for your system.

Step 4. (Recommended) Verify that monitors are correctly operating; for example, simulate a hardware failure or event and view the logs.

The default hardware monitoring configuration meets most monitoring requirements. By default, messages regarding warning, serious, and critical events are written to /var/adm/syslog/syslog.log and sent to the root e-mail address. All events are also stored in /var/opt/resmon/log/event.log.

If you must customize the default monitoring configuration, you can add or modify monitoring requests as needed.

Chapter 3 45

Page 46: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceOffline Diagnostics Environment (ODE)

Offline Diagnostics Environment (ODE)All HP Fibre Channel adapters support the HP Offline Diagnostics Environment (ODE). ODE is an offline support tools platform for troubleshooting HP/9000 and HP Integrity systems running without an operating system, or systems that cannot be tested using online tools. The offline environment is also useful for testing before a system is booted.

ODE provides a user-friendly interface for diagnostics and utilities developed to run in an offline environment.

ODE has a distributed architecture consisting of several modules. Each module has a specific function and uses well defined protocols to communicate with the other modules.

You can use either the command-line interface or the menu-driven interface. The command-line interface enables you to select tests and utilities to execute on a specific hardware module. The menu-driven interface enables you to specify the hardware module to be tested, then ODE selects the appropriate tests to execute on the module.

ODE consists of the following:

Test Controller Acts as the user interface and launches the execution of the Test Modules.

Test Modules Diagnostic or utility programs designed to execute within ODE. These modules exercise or diagnose user-specified hardware units.

System Library (SysLib) A set of common routines for use by both the Test Controller and the Test Modules. These routines perform I/O, string parsing, and system control.

For more information on ODE, see the Itanium Processor Family (IPF) Offline Diagnostics and Utilities CD Overview at:http://docs.hp.com/en/diag.html#Offline%20Diagnostics

Chapter 346

Page 47: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceDiagnostic Flowcharts

Diagnostic FlowchartsThe diagnostic flowcharts illustrate the following tests:

Flowchart 1: Configuration Test

Verifies the configuration of the mass storage interface on a host using the ioscan (1M) command.

Flowchart 2: Fibre Channel Connections Test

Checks all hardware connections between your system and Fibre Channel mass storage devices, to confirm that they are connected and operational.

Flowchart 3: Boot Test

Verifies that the system boots correctly over Fibre Channel.

See the Support Matrix for the Fibre Channel adapter you are troubleshooting for current system and adapter firmware requirements and other information. Support Matrixes for HP Fibre Channel adapters are available at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

Chapter 3 47

Page 48: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceDiagnostic Flowcharts

Figure 3-1 Flowchart 1: Configuration Test

1

HPadapter

displayed?

Enter the ioscan command

no

no4

yes

yes

yes

no

B

A

C

E

H

F

2

Enter theswlist command

ReinstallFibre Channel software

DONE

Device displayed?

1

Is theFC FILESET

displayed?

Go to Flowchart 2

On Flowchart 2

CLAIMED?

Hardware2

yes

no

IsSystem Firm-ware version

adequate?

yes

Update

Firmware

1

Go to Flowchart 2

G

I

D

no

state =

System

Chapter 348

Page 49: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceDiagnostic Flowcharts

Flowchart 1: Configuration Test Procedures

The sections below provide additional detail on the procedures listed in Flowchart 1.

A. Enter the ioscan command to display information about attached peripherals that are successfully bound to the system; for example, enter /etc/ioscan-f. For more information, see the ioscan manpage.

B. HP adapter displayed? The ioscan output displpays information about every peripheral adapter in the system backplane.

C. Hardware state = CLAIMED? The hardware state is operational if “CLAIMED” displays for the Fibre Channel adapter under the Hardware State heading. If the Fibre Channel adapter is “CLAIMED”, go to H. If the Fibre Channel adapter is not “CLAIMED”, go to number 2 on Flowchart 2.

D. Check the Support Matrix for the minimum system firmware version required to support the Fibre Channel adapter in your system, then confirm which system firmware version you have. If the system firmware meets or exceeds the minimum required version, go to E. If not, go to G.

E. Enter the swlist command to see if the Fibre Channel Mass Storage filesets have been installed. For example, enter swlist -l fileset.

F. Does FC FILESET display? The file sets displayed depend on the Fibre Channel adapter product you are using. An example of file set for the PCI Tachyon TL and XL2 adapters is:

FC-TACHYON-TL-FC-TL-KRN and FC-TACHYON-TL-RUN

An example file set for the A6826A dual port adapter is:

FC-FCD-KERN and FC-FCD-RUN

An example file set for other Fibre Channel adapters is:

FCMassStorage.FCMS-KRN and FCMassStorage.FCMS-RUN

If the proper FILESET displays, and you still do not see the adapter, the adapter may have a problem. Go to Flowchart 2. If the file sets do not display, proceed to I.

G. Update the system firmware. Then go back to number 1 on Flowchart 1.

H. Device Displayed? If devices do not display, go to number 4 on Flowchart 2.

Chapter 3 49

Page 50: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceDiagnostic Flowcharts

Fibre Channel Connections Test

Figure 3-2 Flowchart 2: Fibre Channel Connections Test

Run the devicediagnostics

F

Verify that theFC adapter is

properly seated

Verify that the connectors are

solidly connected

Verify theconnection to

A

C

the device

D

4

2

no

yes

Reinstall

Adapter problem,Call HP

B

Verify that the

powered on

E

device is

1

1

Flowchart 1

Go to Flowchart 1

Go to

the adapter

Chapter 350

Page 51: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceDiagnostic Flowcharts

Flowchart 2 Connections Test Procedures

The sections below provide additional detail on the procedures listed in Flowchart 2.

A. Verify that the Fibre Channel adapter is properly seated. Shut down the system by entering /usr/sbin/shutdown -h. Power off the system and disconnect the cables. Check that the adapter is properly seated in the backplane. To verify that it is seated correctly, power on the system.

B. Adapter problem, call HP. Contact your HP service representative for assistance.

C. Verify that the connectors are solidly connected. Without powering off the system, make sure that the connectors on the fiberoptic cable match the keyed connectors on the adapter, and that they are solidly connected.

D. Verify the connection to the Fibre Channel Mass Storage device. Make sure the Fibre Channel cable is fully connected to the Fibre Channel Mass Storage device, and the device is operating. Follow the instructions in the device manual to check the device state. Try changing the connection to a different port on the Fibre Channel Mass Storage device, if possible. After checking the connections, go to Flowchart 3.

E. Verify that the Fibre Channel Mass Storage device is powered on. If not, power on the device.

F. Run Fibre Channel Mass Storage device-specific diagnostics. If diagnostics are available to troubleshoot the Fibre Channel Mass Storage device, follow the steps to verify that the device is functioning properly. After verification, go to Flowchart 3.

Chapter 3 51

Page 52: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceDiagnostic Flowcharts

Figure 3-3 Flowchart 3: Boot Test

B

no

no

yes

D

C

Is the

yes

noAsystem bootable

over FC?

See the boot devicein your system manual

yes

Update firmware

E

Update adapterROM firmware

G

noF

34

Update adapterEFI version

Go to Flowchart 2

Go to Flowchart 1

Go to Flowchart 1

Go to Flowchart 1

31

31

31

33

IsSystem Firm-ware version

adequate?

Isminimum ad-

apter ROM firmwareinstalled?

Isminimum ad-

apter EFI versioninstalled?

Chapter 352

Page 53: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceDiagnostic Flowcharts

Flowchart 3: Boot Test Procedures

The sections below provide additional detail on the procedures listed in Flowchart 3.

A. Is the system bootable over the Fibre Channel adapter? Only certain systems can boot over the Fibre Channel adapter. If your system cannot do this, you must boot from a SCSI device.

B. Is the system firmware version adequate? Check the system firmware version on your system for the minimum required date code for your adapter. If Yes, go to step D; if No, go to step C.

C. Update firmware. Update the firmware to the appropriate level.

D. Is the minimum required Fibre Channel adapter ROM firmware installed? This step applies to Fibre Channel adapters installed in HP/9000 and HP Integrity systems. If the minimum ROM firmware version (or a later version) is installed, go to 4 on Flowchart 2. If not, go to step E.

E. Is the minimum required EFI version for the Fibre Channel adapter installed? This step applies to Fibre Channel adapters installed in HP Integrity systems only. If the minimum EFI version (or a later version) is installed, go to 4 on Flowchart 2. If not, go to step G.

Chapter 3 53

Page 54: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceFirmware Updates

Firmware UpdatesThis section explains the process for updating the firmware of your Fibre Channel host bus adapter.

Fibre Channel Host Bus Adapter Online Firmware Updates

The Fibre Channel host bus adapters that use the FCD driver can be updated while the system is online by using the rom_fw_update option of the fcmsutil command.

CAUTION Do not attempt to use the following procedure if the adapter is attached to a boot disk, swap, or dump device; this will result in a system hang.

An example of updating the A6826A firmware is as follows:

# fcmsutil /dev/fcd8 rom_fw_update romfw.bin

WARNING: This is a DESTRUCTIVE operation.This might result in failure of current I/O requests.Do you want to continue? (y/n) [n]...y##### IMPORTANT NOTICE:

If boot disks are connected to this HBA and your system isnot configured with LVM or if LVM is configured withoutfailover capablity, this operation can cause significantsystem downtime in case any error occurs during the ROMupdate operation.

Do you want to continue? (y/n) [n]...y

Please save the below Vital Product Data (VPD) information.If the ROM update fails due to an irrecoverable error, thisdata may be lost forever. In such a scenraio, this data canbe used to restore back the VPD onto the failed ROM, duringODE recovery procedures.

V I T A L P R O D U C T D A T A--------- ------------- -------

Product Discription : "Dual Port 2Gbps/1Gbps Fibre Channel Universal PCI-X Adapter"Part number : "A6826-60001"Engineering Date Code : "X-4306"Part Serial number : "US00000083"Misc. Information : "PW=15W;PCI 66MHZ;PCI-X 133MHZ"Mfd. Date : "4306"Check Sum : 0x52EFI version : "001.00"ROM Firmware verision : "03.02.07"Asset Tag : "NA"

This operation may take upto 30 secs to complete...

<ROM GETS UPDATED HERE>

ROM has been updated successfully. The new firmwareand the VPD updation will take effect only after thethe system has been rebooted.#

Chapter 354

Page 55: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceFirmware Updates

Fibre Channel Host Bus Adapters Offline Driver and Firmware Updates

The Extensible Firmware Interface (EFI) is an Itanium-based preboot environment used to update the EFI driver and firmware on the adapter. EFI can be used in either command-line interface mode or batch mode. The following example demonstrates the use of the efiutil command-line interface stored on a CD to update an EFI driver:

1. From the EFI prompt, enter the map -r command.

2. Enter the cd command to change to the directory containing efiutil.

3. Enter the efiutil command to get to the command line interface for efiutil.

4. Choose the adapter you want to update as shown below:

efiutil> adapter

Adapter Index number [0]? <n>

Where: <n> represents the adapter index you want to update.

5. To update the EFI driver, enter the following command:

efiutil> efi_write=<EFI driver file name>

6. To update the card firmware, enter the following command:

efiutil> risc_fw_write=<firmware file name>

7. After the update process is complete, reset the system by entering the following command:

fsx:\> reset

Chapter 3 55

Page 56: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Troubleshooting and MaintenanceFibre Channel Device Scanning Policy Configuration for HP Integrity Systems

Fibre Channel Device Scanning Policy Configuration for HP Integrity SystemsThe drvcfg utility is an EFI shell command that can be used to set the Device Scanning Policy in the Fibre Channel EFI driver.

The -s option for the drvcfg utility provides two enumeration policy options for Fibre Channel: 0 and 1. With this setting, the Fibre Channel driver only scans devices that are in the current boot order list in NVRAM. If option 1 is selected, the Fibre Channel driver scans all the devices connected to the Fibre Channel cards installed on the system. Review the EFIFCScanLevel setting in the drvcfg utility for more information.

NOTE When the setboot command is invoked on a device, that device is added implicitly to the boot order list as a primary or alternate boot path. When HP-UX is cold installed on a device, that device is automatically set as the primary path by the implicit invocation of setboot during the installation process.

For more information on using the drvcfg utility, enter help drvcfg at the EFI shell prompt.

Chapter 356

Page 57: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

A Regulatory Statements

This appendix contains the regulatory statements and declarations of conformity for the HP Fibre Channel host bus adapters.

Appendix A 57

Page 58: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Regulatory StatementsRegulatory Statements

Regulatory Statements

FCC Statement (USA Only)

The Federal Communications Commission (in 47 CFR 15.105) has specified that the following notice be brought to the attention of the users of this product.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The end user of this product should be aware that any changes or modifications made to this equipment without the approval of Hewlett-Packard could result in the product not meeting the Class A limits, in which case the FCC could void the user’s authority to operate the equipment.

IEC Statement (Worldwide)

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

DOC Statement (Canada)

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil numerique de la classe A respecte toutes les exigences du Réglement sur le materiel brouilleur du Canada.

Spécification ATI Classe A (France)

DECLARATION D’INSTALLATION ET DE MISE EN EXPLOITATION d’un matériel de traitement de l’information (ATI), classé A en fonction des niveaux de perturbations radioélectriques émis, définis dans la norme Européenne EN 55022 concernant la Compatibilité Electromagnétique.

Cher Client,

Conformément à la Réglementation Française en vigueur l’installation ou le transfert d’installation, et l’exploitation de cet appareil de classe A, doivent faire l’objet d’une déclaration (en deux exemplaires) simultanément auprès des services suivants:

• Comité de Coordination des Télécommunications 20, avenue de Ségur - 75700 PARIS

• Préfecture du département du lieu d’exploitation

Le formulaire à utiliser est disponible auprès des préfectures.

La déclaration doit être faite dans les 30 jours suivant la mise en exploitation.

Le non respect de cette obligation peut être sanctionné par les peines prévues au code des Postes et Télécommunications et celles indiquées dans la loi du 31 mai 1993 susvisée.

Arrêté du 27 Mars 1993, publié au J.O. du 28 Mars - ATI

Appendix A58

Page 59: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Regulatory StatementsLaser Safety Statements

VCCI Statement (Japan)

Figure A-1 Japanese VCCI Statement

Laser Safety Statements

Certification and Classification Information

This product contains a laser internal to the Optical Link Card/Optical Link Module (OLC/OLM) for connection to the Fibre communications port.

In the USA, all models of the OLC/OLM are certified as Class 1 laser product and conform to the requirements contained in the Department of Health and Human Services (DHHS) Regulation 21 CFR subchapter J. The certification is indicated by a label located on the plastic OLC/OLM housing.

Outside the USA, all models of the OLC/OLM are certified as Class 1 laser components that conform to the requirements contained in the International Electrotechnical Commission (IEC) standard 825 (1994) and Amendment 1 (1990) along with the CENELEC (European Committee for Electrotechnical Standardization) European Normalization Standard EN 60825 (1992).

Certifications include one or more of the following: Recognized Component by Underwriters Laboratories, Certified by the Canadian Standards Association, Certified by VDE (Germany) and/or Certified by Statens Provningsanstalt (SP) in Sweden.

Figure A-2 shows the Class 1 information label specified in IEC 825 and CENELEC HD 482 51.

Figure A-2 Class 1 Laser Label

Class 1 Laser Product

Laser Klasse 1

Luckan 1 Laserlaite

Appareil A’Laser de Classe1

Appendix A 59

Page 60: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Regulatory StatementsLaser Safety Statements

Product Information

Each communications port consists of a transmitter and receiver optical subassembly. The transmitter subassembly contains internally a semiconductor laser diode in the wavelength of 770 to 850 nanometers. In the event of a break anywhere in the fibre path, the OLC/OLM control system prevents laser emissions from exceeding Class 1 levels.

Class 1 laser products are not considered hazardous.

WARNING There are no user maintenance or service operations or adjustments to be performed on any OLC/OLM model.

Usage Restrictions

Failure to comply with these usage restrictions may result in incorrect operation of the system and points of access may emit laser radiation above the Class 1 limits established by the IEC and U.S. DHHS.

Laser Safety (Finland) LASERTURVALLISUUS

LASERTURVALLISUUS

LUOKAN 1 LASERLAITE

KLASS 1 LASER APPARAT

Fibre Channel 1063 MBaud Optical Link -kortille on asennettu optista tiedonsiirtoa varten laserlähetin, joka lähettää signaalit siihen kytketyn optisen kuidun kautta.

Normaalissa toimintatilassa lähetin on käyttäjälle turvallinen luokan 1 laserlaite, eikä käyttäjä voi altistua sen lähettämälle säteilylle. Optisen lähetinmoduulin turvallisuusluokka on määritetty standardin

EN 60825 (1991) mukaisesti.

Optisessa lähetinmoduulissa ei ole huollettavia kohteita eikä sen tehtaalla tehtyjä säätöjä tule muuttaa. Lähetinmoduuli on myös suunniteltu siten, että turvallisuusluokan 1 säteilyrajat eivät ylity, vaikka lähetinmoduuliin kytketty optinen kuitu rikkoutuu tai kytketään irti lähettimen toimiessa.

Lähetinmoduulin turvallisen toiminnan varmistamiseksi on noudatettava tarkoin sen asentamisesta ja toiseen vastaanottavaan laitteistoon kytkemisestä annettuja ohjeita.

Tiedot optisessa lähetinmoduulissa käytettävien laserdiodien säteilyominaisuuksista:

Aallonpituus

(SW) 770-850 nm

Appendix A60

Page 61: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

B Technical Specifications

This appendix provides technical specifications for the Fibre Channel Host Bus Adapters.

Appendix B 61

Page 62: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Technical SpecificationsA6826A Technical Specifications

A6826A Technical SpecificationsTable B-1

Characteristics 2125 Mbps/1063 Mbps short-wave, SFF non-OFC

Connector Two LC Duplex

Slot PCI/PCI-X

Physical

Length 168 mm (6.61 inches)

Width 63.8 mm (2.50 inches)

Height 9.8 mm (0.39 inches)

Weight 87.9 g (3.1 Oz)

Electrical 5.5 watts (nominal); 15 watts (max)

Standards Complies with ANSI standards (ANSI X3T11) for standard Fibre Channel

Environmental

Temperature +5 to +40 degrees C (+41 to +104 F) operating-40 to +70 degrees C (-40 to +177 F) nonoperating

Relative Humidity

5% to 90% @ 65 degrees C (149 degrees F) noncondensing, nonoperating

20% to 80% @ 40 degrees C (104 degrees F) non-condensing, operating

Altitude 4.5 km (15,000 ft)

Electromagnetic

USA FCC Class A

Europe CISPR-22 Class A

Germany FTZ-1046 (VDE Level B)

Japan VCCI Class I

Laser Safety Class 1

Appendix B62

Page 63: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Technical SpecificationsAB378A & AB378B Technical Specifications

AB378A & AB378B Technical Specifications

Performance Characteristics

Local bus mode and speed PCI-X 266MHz, PCI-X 133MHz, PCI-X 66MHz, PCI 66MHz, PCI 33MHz

Connectivity Single port Fibre Channel, multi-mode short-wave optical link

Link Speed 4Gbps / 2Gbps / 1Gbps

Link Distance 4Gbps : 150m; 2Gbps : 300m; 1Gbps : 500mOver 50/125um multi-mode fiber optic cable

Connector One LC Duplex Connector

Bus Slot 3.3V only, 64-bit PCI-X 266MHz, PCI-X 133MHz, PCI-X 66MHz, PCI 66MHz

Physical

Length 168 mm (6.61 inches)

Width 63.8 mm (2.5 inches)

Height 9.8 mm (0.39 inches)

Weight 91 g (3.2 Oz)

Electrical 6.5 watts (nominal); 7.5watts (max)

Standards Complies with ANSI standards (ANSI X3T11) for standard Fibre Channel, PCI Local Bus specification Rev 2.3, PCI-X protocol addendum rev 2.0a, and PCI-X Electrical/Mechanical spec 2.0a

Environmental

Temperature +5 to +40 degrees C (+41 to +104 F) operating-40 to +70 degrees C (-40 to +177 F) non operating

Relative Humidity 5% to 90% @ 65 degrees C (149 degrees F) non-condensing, non-operating20% to 80% @ 40 degrees C (104 degrees F) non-condensing, operating

Altitude 4.5 km (15,000 ft)

Electromagnetic

USA FCC Class A

Europe CISPR-22 Class A

Germany FTZ-1046 (VDE Level B)

Japan VCCI Class I

Laser Safety Class 1

Appendix B 63

Page 64: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Technical SpecificationsAB379A & AB379B Technical Specifications

AB379A & AB379B Technical SpecificationsTable B-2

Performance Characteristics

Local bus mode and speed PCI-X 266MHz, PCI-X 133MHz, PCI-X 66MHz, PCI 66MHz, PCI 33MHz

Connectivity Dual port Fibre Channel, multi-mode short-wave optical link

Link Speed 4 Gbps / 2 Gbps / 1 Gbps

Link Distance 4Gbps : 150m; 2Gbps : 300m; 1Gbps : 500mOver 50/125um multi-mode fiber optic cable

Connector Two LC Duplex Connectors

Bus Slot 3.3V only, 64-bit PCI-X 266MHz, PCI-X 133MHz, PCI-X 66MHz, PCI

Physical

Length 168 mm (6.61 inches)

Width 64.5 mm (2.54 inches)

Height 9.8 mm (0.39 inches)

Weight 104 g (3.7 Oz)

Electrical 6.5 watts (nominal); 8.0watts (max)

Standards Complies with ANSI standards (ANSI X3T11) for standard Fibre Channel, PCI Local Bus specification Rev 2.3, PCI-X protocol addendum rev 2.0a, and PCI-X Electrical/Mechanical spec 2.0a

Environmental

Temperature +5 to +40 degrees C (+41 to +104 F) operating-40 to +70 degrees C (-40 to +177 F) non operating

Relative Humidity 5% to 90% @ 65 degrees C (149 degrees F) non-condensing, non-operating20% to 80% @ 40 degrees C (104 degrees F) non-condensing, operating

Altitude 4.5 km (15,000 ft)

Electromagnetic

USA FCC Class A

Europe CISPR-22 Class A

Germany FTZ-1046 (VDE Level B)

Japan VCCI Class I

Laser Safety Class 1

Appendix B64

Page 65: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

C Additional Features

This chapter discusses the SNIA Application Programming Interface that can be used with the Fibre Channel Host Bus Adapters.

Appendix C 65

Page 66: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Additional FeaturesFibre Channel SNIA HBA API

Fibre Channel SNIA HBA APISoftware applications managing SANs require information from host bus adapters (HBAs) to operate. Every vendor, operating system, and platform provides HBA information differently.

The HP Fibre Channel Storage Network Industry Association Host Bus Adapter Application Programming Interface (FC SNIA HBA API) is a C library interface that was created to provide a common HBA API library for all Fibre Channel HBA vendors, and a vendor specific API library for HP supported Fibre Channel adapters. The API is part of the driver software. It is loaded when you install the driver.

HP created the FC SNIA HBA API for programmers who want to use this API to write applications for managing SANs. This API can be used with the Fibre Channel host bus adapters using the FCD driver.

At a high level, the common HBA library handles multiple vendor implementations of the API by dynamically loading libraries. At a lower level, a vendor-provided library provides vendor-specific implementations of the API.

The FC SNIA HBA API supports multithreading and OLAR on OLAR supported platforms and adapters.

The Fibre Channel SNIA HBA API Programmer's Guide is available at:http://docs.hp.com/en/netcom.html#Fibre%20Channel

It is also available on the HP-UX Instant Information CD delivered with your HP-UX product updates.

Appendix C66

Page 67: HP Fibre Channel Mass Storage Adapters Support Guide ...kmcs-service.austin.hp.com/km-ext/kmcsdirect/emr_na-c02013757-1.pdf · Chapter 1 Adapter Overview HP Fibre Channel Mass Storage

Index

AA6684A HSC Tachlite adapter, 44

installing software, 22A6685A HSC Tachlite adapter, 38, 44, 62

installing software, 22A6795A FC PCI XL2 adapter, 14, 21

description, 14supported topologies, 14

adapter LEDsA3591A/B, 36A5158A, 36A6684A, 36A6826A, 36

AL_PA, 32Arbitrated Loop Physical Address (AL_PA), 32auto-speed negotiation, 14

Ccable products, 26cabling requirements, 21customer replaceable units (CRUs), 21

Ddiagnose tool, 43diagnostic flowcharts

flowchart 1, configuration test, 48flowchart 2 procedures, 49flowchart 2, FC connections test, 50flowchart 3 procedures, 51flowchart 3, boot test, 52

EEvent Monitoring Service (EMS), 44

FFC SNIA HBA API, 66fcmsutil, 37

device file, 37options, 37

Fibre Channel adapter monitordescription, 44installation procedures, 45installation requirements, 44supported products, 44

Fibre Channel System Network Industry Association HBA Application Programming Interface, 66

field replaceable units (FRUs), 21

Hhardware monitor, 44HBAs (host bus adapters), 7host bus adapters, 7

Iinformation tool, 42installing driver software

A6684A, 22A6685A, 22

for A6795A, 22interpreting hardware path

private loop devices, 30public loop devices, 30

LLEDs, 36logtool utility, 42

Ooffline diagnostics, 42online diagnostics, 37

SSTM modes, 42STM tools

diagnose, 43information, 42logtool utility, 42

Support Tools Manager (STM), 42

Ttechnical specifications, 62

A5158A, 62troubleshooting overview, 35

Uusing EMS, 44using fcmsutil, 38

Vverifying connectivity, 29Vital Product Data, 14, 37, 38VPD (Vital Product Data), 14, 37, 38VPD example, 39, 40

67