H Install and Optimize Cell Sites Faster! Brochure HP 8921A Cell Site Test Set HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular Adapter HP 83236A PCS Interface
12

HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

Jun 28, 2018

Download

Documents

haduong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

H

Install andOptimize Cell SitesFaster!

Brochure

HP 8921A Cell Site Test SetHP 11807B Cell Site Test SoftwareHP 83204A TDMA Cellular AdapterHP 83205A CDMA Cellular AdapterHP 83236A PCS Interface

Page 2: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

2

A partner you

can count on

. . .Hewlett-Packard

can help you with

fast, high-quality,

installation and

maintenance testing

As a service provider,

manufacturer or

installer, you know

how difficult it is

to keep up with the

demand for new

technologies. . .

The HP 8921A

RF Test Set

Family —

a total solution

for wireless

infrastructure

test

Page 3: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

3

Worldwide training and support to

help you manage your support

organization more effectively -

• On-site training

• 1-800 technical phone support

• Worldwide support

AMPS/TACS/TDMA

Proven Performance in

Infrastructure Test

Hewlett-Packard's fully-automatedinstallation and maintenance test solu-tion has freed technicians from hours oftedious manual testing. Our customershave found the HP 8921A/11807B in-creases technician efficiency for basestation maintenance while improvingcellular system reliability.

Test equipment with

performance and auto-

mation advantages to

help you establish and

maintain customer

preference for your

system’s quality -

CDMA

HP pioneered the waveform qualitymeasurement rho (r) for CDMA basestations to indicate the overall perfor-mance level of CDMA transmitters.Rho and code domain analysis (a newmeasurement concept to measurepower in each code channel) giveHewlett-Packard’s CDMA solution aclear performance advantage forbase station maintenance.

Page 4: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

4

HP 8921A Cell Site

Test Set

The HP 8921A Cell Site Test Setcombines over twenty highperformance instruments withan internal controller to auto-mate installation and mainte-nance testing on base stations.

HP 8921A Standard

Features

• Synthesized AM/FM signalgenerator

• AM/FM modulation analyzer

• Duplex offset generator

• RF power meter

• RF frequency counter/errormeter

• Synthesized spectrumanalyzer

• Tracking generator

• Audio frequency counter

• AF power meter

• AC voltmeter

• DC voltmeter

• DC current meter

• Distortion meter

• SINAD meter

• Signal-to-noise meter

• Two synthesized variableaudio sources

• Function generator

• Cellular signaling encoder/decoder

• Digital oscilloscope

• Built-in IBASIC controller

• IEEE 488.2, parallel printer,and RS-232 interfaces

High Performance Spectrum

Analyzer and Tracking

Generator

The spectrum analyzer of theHP 8921A has the wide dynamicrange and synthesized frequencyaccuracy found in expensivestand-alone spectrum analyzers.

• Wide dynamic range to locatelow-level signals in thepresence of high-powertransmitters

• Synthesized accuracy for highconfidence that you’ve locatedthe correct signals

• Adjacent channel powerscreen for transmittermeasurements

• Built-in tracking generatorwith performance featuresoptimized for measuringduplexers

• Flexible display- 1/2/10 dB per division scale- Markers- Display averaging- Trace normalization

Reliability

A large percentage of techniciantime is spent getting to and fromremote cell sites. Reliable testequipment is essential to makesure each visit is productive.The HP 8921A is tested tostringent MIL-STD environmen-tal specifications; operatingtemperatures from 0 to 55degrees C, humidity up to 95%and shock forces as great as30 g’s.

Cell Site Troubleshooting

Simplified

Streamline cell site trouble-shooting with the HP 8921Ausing HP 11807B or HP 11807AOption 100 system supporttest software.

Measurements on cell-sitecables, antennas, filters, andattenuators can be automatedfor faster, more consistenttroubleshooting.

Measurement routines include:

• Cable fault

• AMPS channel return loss

• Swept gain and loss

• Swept return loss

• Field strength

• Frequency scanner

Cellular Phone Test

HP 8921A performance includescellular phone test capability inaddition to cell site test. SeveralHP 11807A cellular phone testsoftware packages are compatiblewith HP 8921As, providing a fast,fully-automated phone testsolution.

Compatible HP 11807A packagesinclude:

AMPS/EAMPS/NAMPS: Option 004

TACS/ETACS: Option 005

JTACS/NTACS: Option 007

TDMA Dual-Mode using TIA adapter(IS-54) DAMPS: Option 008

AMPS/EAMPS/NAMPS/TDMA(IS-54) DAMPS over-the-air:Option 009

For more information on HP 11807Asoftware, refer to the HP 11807A/Eproduct overview, part number5965-2783E. For configurationinformation, refer to the HP 8921Aconfiguration guide, part number5965-1577E.

Page 5: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

5

HP 8921A with TDMA or CDMA Adapter

HP 8921A Performance Features

PCS Interface

• High-power input teststransmitters up to 60 watts(to 100 W intermittently)

• 2 mV sensitivity at theantenna input allows over-the-air signal monitoring

• Power meter with 5% accuracy

• Signal-to-noise ratio meter foraudio signals

User Features

• SAVE/RECALL saves entireinstrument states and can bestored internally, or to amemory card for quickretrieval of custommeasurement setups

• Easy printout of measurementresults, test results, andspectrum analyzer and scopescreens to external RS-232,parallel, or HP-IB printers

• Store test results, spectrumanalyzer and scope screens toRAM cards or to your PC forretrieval and printing at aconvenient time

• Quick and easy instrumentcontrol with front-panelcontrol knob

Page 6: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

6

Test conditions Measured value Lower limit Upper limit P/F===========================================================Frequency error -356.59 Hz -900.00 900.00Transmitter power 45.92 Watts 40.00 50.00TX audio level 775.6 mV 770.0 780.0Voice channel deviation 8.2 kHz 6.6 9.4TX data (const. symbol) freq. 10.000 kHz 9.995 10.005TX data (const. symbol) dev. 8.0 kHz 6.6 9.4TX SAT freq. error @ 5970 0.1 Hz -3.0 3.0

Easy Setup

The HP 11807B software guidesyou through each step of optimiz-ing your cell site. When connec-tion changes are required, theHP 8921A graphically displaysthe connection diagram. TheHP 11807B follows the test andadjustment procedures recom-mended by the manufacturers.Clear labeling on the connectiondiagram eliminates errors andreduces the need to refer to thebase station documentation.

Visual and Audio Feedback

The HP 11807B Cell Site TestSoftware gives both visual andaudible feedback when adjust-ments are required. A largeanalog meter displays thecurrent reading while highlight-ing the specified tolerancerange. Audible feedback in theform of audio tones allowsadjustments to be made whenthe HP 8921A display cannot beseen. High and low tonesindicate high or low measure-ments while a repetitive toneindicates proper adjustment.

Flexible Configuration

Customize the HP 11807Bsoftware to fit your cell site testand maintenance needs. Oncespecific setups are developedthat fit your needs, store themfor further use on rugged, non-volatile memory cards. Withpersonalized procedures, main-tenance can be standardized toimprove network quality andtechnician efficiency.

Test Results

The HP 11807B Cell Site TestSoftware displays measurementresults on the HP 8921A screen.Alternatively, send results to anHP-IB, RS-232, or parallel printerto document test results. Dualserial ports enable the HP 8921Ato control the base station undertest via the HP 11807B softwareas well as send test results to aserial printer. If archiving testresults is desirable, use optionalbattery-backed RAM cards tosave test results or store themto your PC.

HP 11807B Automation

Benefits for AMPS,

TACS, and TDMA

Thorough Testing in

Less Time

The fast measurement speedof the HP 8921A coupled withHP 11807B automated softwareresults in less time off-line foreach transceiver during mainte-nance work.

Since all cell sites are uniformlytested with the same proce-dures, problems are detectedearlier. Errors due to testvariability are eliminated andhuman errors are reduced.Standardizing system main-

tenance increases system

integrity.

Measurement data can be outputto an external printer or storedon memory cards for futurereference. By analyzing

measured data, suspect

transceivers can be identi-

fied and failures anticipated.

The end result is a cellular

system that provides more

reliable service with fewer

unexpected problems.

Page 7: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

7

AMPS / TACS

Install and maintain AMPS,NAMPS, TACS, ETACS, andUTACS cell site radio equipmentwith the HP 8921A Cell Site TestSet and the HP 11807B Cell SiteTest Software.

Complete Testing

The HP 8921A/11807B testsolution uses the HP 8921A’sbuilt-in IBASIC controller tofully automate base station testprocedures with the HP 11807Bsoftware test packages.

Developed from manufacturer’srecommended maintenanceprocedures, the HP 11807B CellSite Test Software ensurescomplete test and adjustmentof cell sites as recommendedby the manufacturers. By usingthe standardized maintenanceprocedures, each cell sitereceives the same high qualityanalysis and adjustment.

Coverage for Analog and

Digital Cellular Systems

Besides testing current AMPSand TACS base stations, theHP 8921A is ready to grow withyour measurement needs forfuture cellular systems.

TDMA - The HP 83204A TDMACellular Adapter adds a com-plete p/4 DQPSK signal genera-tor, modulation analyzer, andBER analyzer to the HP 8921Awhile maintaining all analogmeasurements for dual-modetesting of IS-136 digital cellularformats.

HP 11807B AMPS / TACS / TDMA Cell Site Test Software

Installation / maintenance test procedures are available formanufacturer base stations listed below:

Motorola: • HDII/AMPS, HDII /NAMPS, LD AMPS• TACS/ETACS/UTACS/EUTACS• Micro C•I•T•E AMPS/NAMPS

General Electric RCU: • Analog, Extended Frequency Analog,and Compact RCU AMPS

Ericsson: • 882, 882M, 882D AMPS Analog, Microcell and TDMA• 883, and 883M TACS/ETACS Analog and Microcell

Lucent (formerly AT&T) Autoplex Series II:

• AMPS Analog, LMT and Universal Microcell AMPS and TDMA

Nortel: • AMPS Analog, TDMA Digital DRU and Analog P-Series

Hughes: • GMH 2000 AMPS

For universal use: • AMPS Call Analysis, Logging and MonitoringSoftware. See HP 11807B Option 120 Product Overview,part number 5963-6891 for more information.

CDMA - For test and support ofIS-95A/97 CDMA base stationequipment, add the HP 83205ACDMA Cellular Adapter forsignal generation and analysisof QPSK/OQPSK signals.The HP 8921A retains its fullcapabilities for testing theanalog performance of dual-mode CDMA base stations.

CDPD - The HP 8921A hasoptional Cellular Digital PacketData (CDPD) test capabilityfor installing and maintainingCDPD Mobile Data Base Station(MDBS) RF infrastructureequipment. Select CDPD test

as an option to the HP 83204ATDMA Cellular Adapter or theHP 83205A CDMA CellularAdapter.

PCS - Adding the HP 83236APCS Interface to HP 8921ATDMA and CDMA systems is acost-effective way to extendTDMA and CDMA measurementsto the 1850 to 1990 MHz fre-quency band (Contact your localHewlett-Packard sales represen-tative for PCS solutions at otherfrequencies). The HP 83236Acan be combined with existingHP 8921A systems withoutreturning them to the factory.

For additional information, refer to other sectionsin this brochure as well as the following literature:

• Technical Specifications: p/n 5965-1576E• Configuration Guide: p/n 5965-1577E• Price List: p/n 5965-1578EUS

Page 8: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

8

For additional information , refer to other sectionsin this brochure as well as the following literature:

• Technical Specifications: p/n 5965-1576E• Configuration Guide: p/n 5965-1577E• Price List: p/n 5965-1578EUS

TDMA

The HP 83204A TDMA CellularAdapter adds TDMA (IS-136)digital measurement capability tothe HP 8921A. It can be orderedstand-alone to add to an existingHP 8921A or as an HP 8921AOption 500 (HP 8921A/83204AOption 001).

The HP 8921A/83204A retains allanalog functions, plus adds thefollowing digital features:

• p/4 DQPSK signal generator

• p/4 DQPSK analyzer

• Bit Error Rate (BER) meter

• Adjacent/alternate channelpower measurements

Digital Measurements

TDMA measurement modes andsettings are accessed on a singletest screen. User setups providequick configuration of the testset to measure key TDMAperformance parameters. Thefollowing measurements canbe performed:

Transmitter Tests:

• RF power

• Frequency error

• Modulation accuracy- Error Vector Magnitude (EVM)including phase errorand magnitude error

- I/Q origin offset

• Adjacent and alternatechannel power

Receiver Tests:(dependent on receiver being tested)

• TDMA sensitivity (BER)

• TDMA RSSI

PCS

Adding the HP 83236A PCSInterface to the HP 8921AOption 500 is a cost-effectiveway to extend TDMA measure-ment capabilities to the 1850to 1990 MHz frequency band(Contact your local Hewlett-Packard sales representative forPSC solutions at other frequen-cies). The HP 83236A can becombined with existingHP 8921A systems withoutreturning them to the factory.

Automation

HP 11807B software fully auto-mates TDMA test proceduresrecommended by equipmentmanufacturers to optimize sys-tem performance. Time-inten-sive setups are eliminatedthrough powerful IBASIC pro-grams. Iterative tests such asreceiver sensitivity are com-pleted in a minimal amount oftime.

CDPD

The HP 83204A TDMA CellularAdapter has optional CDPD testcapability for installing andmaintaining CDPD MDBS RFinfrastructure equipment.HP 8921A Option 503 (HP 8921Aplus HP 83204A Option 003)configures the test set for bothTDMA and CDPD test.

Page 9: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

9

For additional information, refer to other sectionsin this brochure as well as the following literature:

• Technical Specifications: p/n 5965-1576E• Configuration Guide: p/n 5965-1577E• Price List: p/n 5965-1578EUS

CDMA

Test IS-95A/97 base stationswith the HP 8921A Option 600CDMA Cell Site Test System.This system consists of anHP 8921A Cell Site Test Set andthe HP 83205A Option 001CDMA Cellular Adapter. Exist-ing HP 8921As can be upgradedfor CDMA digital testing byadding the HP 83205A. (OlderHP 8921As require the OptionG21 upgrade for complete CDMAcapabilities.) The HP 8921Aretains its full capabilities fortesting the analog performanceof dual-mode CDMA base stations.

The HP 83205A CDMA Adapterfor the HP 8921A embodies anew measurement conceptcalled code-domain analysis.Because multiple users sharethe same transmit frequency,CDMA signals appear aspseudo-random, noise-likewaveforms. Conventionalanalyzers display signals byfrequency and cannot displayindividual code channels. TheHP 8921A/83205A measurespower in each code channel, aswell as measuring code-channeltiming and code-channel phaserelative to the pilot.

Power measurements are madewith a true-average powerdetection scheme to optimizecharacterization of CDMAsystem performance.Another significant contributionof the HP 8921A/83205A is itsmeasurement of waveformquality rho (r) for CDMA basestations. This new measurementwas developed by Hewlett-Packard to indicate the overallperformance level of the CDMAtransmitter.

CDPD

The HP 83205A CDMA CellularAdapter has optional CDPD testcapability for installing andmaintaining CDPD MDBS RFinfrastructure equipment.HP 8921A Option 603 (HP 8921Aplus HP 83205A Option 003)configures the test set for bothCDMA and CDPD test.

PCS

Adding the HP 83236A PCSInterface to the HP 8921AOption 600 is a cost-effectiveway to extend CDMA measure-ment capabilities to the 1850to 1990 MHz frequency band(Contact your local Hewlett-Packard sales representative forPSC solutions at other frequen-cies). The HP 83236A can becombined with existingHP 8921A systems withoutreturning them to the factory.

Digital Measurements

The HP 83205A adds the follow-ing capabilities to the HP 8921A:

• Measurements of waveformquality rho (r), frequencyerror,and pilot time offset

• Code domain power, timingand phase analysis

• True-average power and CDMAchannel power measurements

• CDMA QPSK/OQPSK RFsource with data buffer andIS-95 reverse link coding

• Built-in Added White GaussianNoise (AWGN) source pro-vides calibrated E

b/N

o settings

• Flexible RF and CDMA refer-ence sections

Page 10: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

10

For additional information, refer to other sectionsin this brochure as well as the following literature:

• Technical Specifications: p/n 5965-1576E• Configuration Guide: p/n 5965-1577E• Price List: p/n 5965-1578EUS

HP 8921A with HP 83204A

TDMA/CDPD Adapter

HP 8921A with HP 83205A

CDMA/CDPD Adapter

CDPD

To assure high accuracy powerand sensitivity measurements,the software allows you to entercable loss and coupler lossassociated with connecting thetest set to your MDBS.

The software, included withHP 8921A CDPD options, guidesthe operator to make the properconnections prior to each test.Calibration factors such as cableloss and coupler loss can besaved to a memory card andquickly retrieved when testingdifferent sites.

Measured results and pass failinformation for each test can besaved to a card or to a portablecomputer file via RS-232.

Tests Performed with

CDPD Software:

Transmitter Tests:

• Output power

• Carrier frequency accuracy

• 0.5 GMSK modulationindex accuracy

• Adjacent and alternatechannel power

Receiver Tests:

• Block error rate sensitivity

• Busy set and busy clearflag performance

• Sniffer functionality

System Level Tests:

• Decode and display thefollowing packet data units:

- Channel stream identifier

- Channel configuration

- Channel quality

- Channel access

- Switch channel

The HP 8921A has optionalCellular Digital Packet Data(CDPD) capabilities for install-ing and maintaining CDPDMobile Data Base Station(MDBS) RF infrastructureequipment. CDPD capabilitycan be ordered with TDMA,CDMA, or analog test systemsby selecting the desired "500"or "600" option to the HP 8921A.Existing HP 8921As can beretrofitted with CDPD measure-ment capability by adding anHP 83204A or HP 83205A withthe appropriate option.

CDPD Test

CDPD MDBS test capability isdesigned to quickly and accu-rately test key RF parameters onboth the forward channel trans-mitter and the reverse channelreceiver. In addition, a snifferreceiver test verifies propersniffer functionality. Measure-ment procedures and defaultpass / fail limits are takendirectly from the CDPD systemspecification 1.1.

To perform tests on the MDBS, itis necessary to tap into both theforward channel TX path and thereverse channel RX path di-rectly, or with couplers. All RXtests and sniffer tests require theRX antenna be disconnected.

Page 11: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

11

For additional information, refer to other sectionsin this brochure as well as the following literature:

• Technical Specifications: p/n 5965-1576E• Configuration Guide: p/n 5965-1577E• Price List: p/n 5965-1578EUS

PCS

1 Contact your local Hewlett-Packardsales representative for PSC solutionsat other frequencies.

PCS test solutions for TDMA andCDMA build on the successfulcellular-band HP 8921A testsolutions by adding theHP 83236A PCS Interface toextend testing to the U.S. PCSband (1850 to 1990 MHz)1.(For GSM-based PCS infrastruc-ture equipment testing, refer toHP 85722B literature [SpecialOption H19] part number 5091-9025E).

The HP 83236A PCS Interfacetranslates 1850-1990 MHz PCSsignals to the RF range of theHP 8921A, enabling the sameTDMA and CDMA measurementsperformed by the solutionsin the cellular band. Powermeasurements are performeddirectly in the HP 83236A tomaximize power measurementaccuracy and speed.

Adding the HP 83236A to exist-ing HP 8921A systems is a cost-effective solution for PCS-bandmeasurement capability. TheHP 83236A can be combinedwith existing HP 8921A systemswithout returning them to thefactory.

PCS Test Solutions

U.S. PCS CDMA:

- HP 8921A- HP 83205A Option 001- HP 83236A

U.S. PCS TDMA:

- HP 8921A- HP 83204A Option 001- HP 83236A

OR

- HP 8921D plus HP 83236A

The HP 83236A is controlled viaHP-IB for base station test. Formanufacturing test, HP-IB com-mands written by the operatorcan be executed from an exter-nal controller, or from theIBASIC controller built into theHP 8921A. The HP 83224AIBASIC Developers Tool Kit isavailable for programmers whoare new to IBASIC languageprograms for the HP 8921A.For more information on theDevelopers Tool Kit, refer toHP 83224A product overview,part number 5964-3897E.

Page 12: HP 8921A Cell Site Test Set HP 11807B Cell Site Test ... · HP 11807B Cell Site Test Software HP 83204A TDMA Cellular Adapter HP 83205A CDMA Cellular ... Ericsson: • 882 ... •

on-line support is obtainedthrough your local Hewlett-Packard representative.

Training

Assure productive testing uponreceipt of the HP 8921A/11807Bwith customer Start-up Assis-tance. Start-up Assistance(HP11807B +36H) should beordered with the HP 8921A/11807B for all first-time opera-tors. Start-up Assistance is aone-day, on-site class taught byan HP 8921A/11807B specialist.Course material demonstratesuse of the software and hard-ware to ensure operators areproductive from the time theyreceive the test equipment.HP 11807B Start-up Assistanceshould be scheduled with your

Hewlett-Packard field engineer tocoordinate training with de-liveryof hardware and software. Classsize is limited to five or lessstudents for efficient learning ina cell site environment.

Software Update Service

To be assured that you alwayshave the most current version ofthe HP 11807B test software,order Software Update Services.With these services a new soft-ware card will be shipped to youwhenever a revision to the pack-age occurs. This service isordered on a yearly basis. Theadvantage of the update serviceis knowing you will automaticallyreceive the latest version ofsoftware as revisions are made.

Application

Support

Videos

Call the HP 8921A Information Line (1-800-344-3802) to get oneof our free 40 minute videos showing AMPS/TACS/TDMA cellsite testing with the HP 8921A/11807B.

• “Install and Maintain AT&T Cell Sites Fast” - p/n 1000-1304E

• “Optimize Motorola Cell Sites Fast” - p/n 1000-1307E

• “Install and Maintain Ericsson Cell Sites Fast” - p/n 1000-1297E

Literature

• “HP 8921A Cell Site Test Set, HP 11807B Cell Site Test Software,HP 83204A TDMA Cellular Adapter, HP 83205A CDMA CellularAdapter, HP 83236A PCS Interface”:

- Technical Specifications - p/n 5965-1576E

- Configuration Guide - p/n 5965-1577E

- Price List - p/n 5965-1578EUS

• “HP 8921A/11807B Option 120 Call Analysis, Logging, andMonitoring Software” Product Overview - p/n 5963-6891EUS

• “HP 83236A PCS Interface” Product Overview - p/n 5964-9655E

• “HP 83224A IBASIC Developers Tool Kit for RF CommunicationTest Sets” Product Overview - p/n 5964-3897E

• “HP 8921A Cell Site Test Set for AMPS Base Station Testing”Product Note 8921-1 - p/n 5962-9475E

• “HP 8921A Cell Site Test Set for TACS Base Station Testing”Product Note 8921-2 - p/n 5962-0157E

Worldwide Support

The HP 8921A Cell Site TestSolution is backed with Hewlett-Packard warranty and world-wide support services. WithHewlett-Packard sales andservice centers worldwide youcan be assured of getting theglobal support you need.

On-line Support

In the U.S. and Canada, on-linetechnical support is a direct toll-free call to a factory technicalrepresentative. Outside the U.S.,

For more information call

1-800-452-4844 or 1-303-452-

4844 or via the Web through

AccessHP at http:www.hp.com