Page 1: HOT WATER SYSTEMS - MIKROFILL Brochures...hot water generator that combines the advantages of both an instantaneous hot water heater and a storage system, creating perfect harmony

I N S P I R E D E F F I C I E N C Y

H I G H E F F I C I E N C Y

H O T W A T E R S Y S T E M S

EXTREME 200, 300 & 500 HIGH EFFICIENCY HOT WATER SYSTEMS wi th INJECTION DYNAMICS

Page 2: HOT WATER SYSTEMS - MIKROFILL Brochures...hot water generator that combines the advantages of both an instantaneous hot water heater and a storage system, creating perfect harmony

I N T R O D U C T I O N

C O N T E N T S

Renowned for developing innovative products, Mikrofill has built its success

on quality, reliability and outstanding customer service.

Our rapidly expanding range of products include commercial condensing

boilers, hot water loading systems and pressurisation equipment.

Mikrofill’s hot water loading systems have been developed specifically to meet

the demands of modern commercial buildings. The Extreme is a domestic

hot water generator that combines the advantages of both an instantaneous

hot water heater and a storage system, creating perfect harmony between

a condensing boiler and a hot water cylinder.

Extreme 200, 300 & 500 4 -5

Technical Data 6

Dimensions 7

Efficiency Data 8 - 9

Example Installation 10

Ancillaries 11

H I G H E F F I C I E N C Y H O T W A T E R S Y S T E M S

extreme

Page 3: HOT WATER SYSTEMS - MIKROFILL Brochures...hot water generator that combines the advantages of both an instantaneous hot water heater and a storage system, creating perfect harmony

H I G H E F F I C I E N C Y H O T W A T E R S Y S T E M S

I N J E C T I O N D Y N A M I C S

extremeThe Wras approved Extreme loading cylinder addresses and overcomes all of the disadvantages of the traditional coil type cylinder, whilst remaining simple and straightforward to install. In addition the operating principle ensures the efficiency of a condensing boiler is optimised during the production of domestic hot water.

Mikrofill’s uncompromising approach to quality materials, design flexibility and engineeringexcellence has resulted in the Mikrofill Extreme, the new standard in hot water generation.

Introducing ‘INJECTION DYNAMICS’, a breakthrough in domestic hot water technology. By utilising this revolutionary method of heating, the Extreme generates hot water faster, cleaner and more efficiently than ever before.

Exceptional flow rates in excess of 2500 litres an hour at 60ºC

F E AT U R E S●Stainless Steel construction.

●Fully insulated, in excess of all current standards.

● Suitable for unvented and open vented systems.

●Available in 200, 300 and 500 litre versions.

●Maximum primary input of 120kw.● Wras approved

B E N E F I T S●Exceptional flow rates – up to 2570

litres an hour at 60°C.

●Injection dynamics – allowing hot water draw off in minutes.

●Optimises boiler cylinder efficiency – up to 94% with a condensing boiler.

●Positive stratification – greatly reduces the risk of Legionella proliferation.

●Design principle achieves 100% of cylinder capacity at 60°C enabling reduced storage requirement.

54

Page 4: HOT WATER SYSTEMS - MIKROFILL Brochures...hot water generator that combines the advantages of both an instantaneous hot water heater and a storage system, creating perfect harmony

EXTREME LOADING CYLINDER WRAS APPROVAL NO 1810093 extreme 200 extreme 300 extreme 500

WEIGHT (EMPTY) 63kg 77kg 100kg

MAX WORKING PRESSURE 10 bar 10 bar 10 bar

MAX PRIMARY TEMPERATURE 90ºC 90ºC 90ºC

DHW FLOW CONNECTION 1” 1 1/4” 1 1/2”

DHW RETURN CONNECTION 1” 1” 1”

PRIMARY FLOW & RETURN CONNECTIONS 28mm 28mm 28mm

MCWS CONNECTION 1” 1 1/4” 1 1/2”

P&T VALVE SETTING 10 Bar & 90ºC

STANDING THERMAL LOSS 137 mj per month 163 mj per month 182 mj per month

ENERGY EFFICIENCY CLASS B B B

H I G H E F F I C I E N C Y H O T W A T E R S Y S T E M S

T E C H N I C A L D A T A D I M E N S I O N S

extreme 2 0 0 , 3 0 0 & 5 0 0

A B

C

H

D

E

F

G

extreme 200 extreme 300 extreme 500

A 380mm 910mm 910mm

B 280mm 810mm 810mm

C 465mm 465mm 570mm

D 735mm 1260mm 1265mm

E 995mm 1530mm 1510mm

F 1305mm 1830mm 1995mm

G 710mm 710mm 795mm

H 300mm 300mm 300mm

DHW Flow

DHW Return

MCWS

Htg Return

Htg Flow P&T VALVE CONNECTION

76

Page 5: HOT WATER SYSTEMS - MIKROFILL Brochures...hot water generator that combines the advantages of both an instantaneous hot water heater and a storage system, creating perfect harmony

H I G H E F F I C I E N C Y H O T W A T E R S Y S T E M S

extremeF L O W C H A R A C T E R I S T I C S

Primary Flow Characteristics for the Extreme 200, 300 and 500

Primary Flow Rate

10 min peak output @60°C

1st Hour continuous operation @60°C Continuous operation @60°C for the Extreme 200, 300 and 500

Primary Resistance

extreme 500

extreme 300

extreme 200

litres per hour

2100

2000

1900

1800

1700

1600

1500

1400

1300

1200

1100

1000

900

800

700

600

500

400

300

200

100

0

30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120

Heat Input kW

All graphs are calculated using a 30ºC⁰∆T primary temperature.All graphs are calculated using a 30ºC⁰∆T primary temperature.

litres per hour

2600

2500

2400

2300

2200

2100

2000

1900

1800

1700

1600

1500

1400

1300

1200

1100

1000

900

800

700

600

500

30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120

Heat Input kW

litres

1000

950

900

850

800

750

700

650

600

550

500

450

400

350

300

250

200

30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120

Heat Input kW

litres per second kPa

1.0 50

0.9 45

0.8 40

0.7 35

0.6 30

0.5 25

0.4 20

0.3 15

0.2 10

0.1 5

0

30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120

0

Primary Heat Input kW

98

Page 6: HOT WATER SYSTEMS - MIKROFILL Brochures...hot water generator that combines the advantages of both an instantaneous hot water heater and a storage system, creating perfect harmony

H I G H E F F I C I E N C Y H O T W A T E R S Y S T E M S

extremeE X T R E M E A N C I L L A R I E S

A schematic drawing of an Ethos wall mounted boiler installation, including a Mikrofill pressurisation package connected to an Extreme domestic hot water loading system.

The Extreme is suitable for installation on both open and unvented domestic hot water systems and comes complete with a preinstalled pressure and temperature relief valve.

The unvented kit supplied includes the following items and is designed to work in conjunction with each Extreme cylinder.

●50 litre potable expansion vessel

●Pressure reducing valve (6.0 bar limit)

●Safety relief valve and tundish

●Check valve

●28mm 2 port valve (to provide a permanent means of isolation to the primary supply)

In addition each cylinder can be ordered with a factory fitted 3kW immersion heater.

IVIV IV

CondenseWaste

MIKROFILL 3

ExpansionVessel

LSV DOC

AAV

Heating Circuit

Mains ColdWater Supply

DOC

IV

ServiceValve

ETHOS Boiler

ETHOSBoiler

TNEV

ORKIM

1110

Please note:- when operating on an “open vented” system additional filtration will be required.

Page 7: HOT WATER SYSTEMS - MIKROFILL Brochures...hot water generator that combines the advantages of both an instantaneous hot water heater and a storage system, creating perfect harmony

Mikrofill Systems Ltd.11 Merse Road, North Moons Moat, Redditch, Worcestershire B98 9HL

T +44 (0)3452 60 60 20 F +44 (0)3452 60 60 21 E [email protected] www.mikrofill.com