Top Banner
Horizontal Firetube Boilers Fulton RB and FBS Steam or Hot Water Boilers Sizes from 60 to 800 BHP Fulton FBS Steam Boiler Fulton RB Steam Boiler
8

Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

Aug 21, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

Horizontal Firetube BoilersFulton RB and FBS Steam or Hot Water Boilers

Sizes from 60 to 800 BHP

Fulton FBS Steam Boiler

Fulton RB Steam Boiler

Page 2: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

Overview:Fulton's RB horizontal firetube boiler features a large furnace area anda large steam space, while offering a smaller footprint than othercomparable boilers. The RB is simple and rugged.

Key Design Features• High Efficiency• Large Steam Disengagement Area• Hinged Door Construction with Integral Burner• Wet Back Design & Low Skin Losses• Seamless Heavy Walled Tubing with Turbulators• Small Footprint

Built to Code• ASME Section I or IV• CSD-1 GasTrain• UL Control Panel

SpecificationsTYPE:

3-pass reverse flame, wet back,firetube steam or hot water boiler

SIZE:60-300 BHP up to 300 psig

BURNER:Gas, Oil, or Combination

EFFICIENCY:Up to 85%

RB • Horizontal Firetube Boiler

Seamless tubes are 30% thicker thanthose typically used in comparableboilers.

No tubes above furnace

Generoustube spacing

Door withIntegral Burner

Page 3: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

Door with self-adjustinghinges and ceramic

fiber insulation.

UL control panelprovided as standard.

Fully modulated gas,oil, or dual fuel burner.

Full length "beam" skid.

Flue Outlet

Steam Outlet Large Steam Disengagement AreaFeed Water InletLevel Control ProbesLarge Steam Volume

Easy access handholesfor cleanout and inspection.

1

2

23

3

3-Pass Design

First Pass - The burner fires down the middle of the furnace.

Second Pass - Hot gases return along the furnace walls to the front door.

Third Pass - The hot gases turn at the door and travel downthrough the submerged tubes, into the exhaust chamber, andexit out the flue.

The Fulton DifferenceThe Fulton Difference

1

2

3

Take a look Inside

Page 4: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

SpecificationsTYPE:

Traditional 3-pass, wet back,firetube steam or hot water boiler

SIZE:100-800 BHP

BURNER:Gas, Oil, or Combination

EFFICIENCY:Up to 84%

FBS • Horizontal Firetube BoilerOverview:The Fulton FBS is a traditional three-pass wet back horizontal firetubeboiler. The furnace is corrugated to maximize efficiency while alsominimizing thermal stress. High water volume and high mass firetubeboiler with a proven design.

Key Design Features• High Efficiency• Large Pressure Vessel and Water Content• Corrugated Furnace• Wet Back Design & Low Skin Losses• Small Footprint• Seamless Heavy Walled Tubing• Three Year PV Warranty

Built to Code• ASME Section I or IV• CSD-1 GasTrain• UL Control Panel

Open Protocol Burner Options:

Page 5: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

3-Pass Design

First Pass - The burner fires down the middle of the furnace.

Second Pass - The hot gases are collected in the rear chamberand then pass through a series of submerged tubes returning tothe front chamber behind the insulated front door.

Third Pass - The hot gases turn at the door and travel downthrough the submerged tubes, into the exhaust chamber, andexit out the flue.

The Fulton DifferenceThe Fulton Difference

1

2

3

Features of the FBS Horizontal Boiler

Flue Outlet

UL control panelprovided as standardFull length "beam" skid Large diameter corrugated furnace

Water-backed design eliminates heavyrefractory and increases efficiency

Steam Outlet Level Control ProbesFeed Water InletLarge Steam Volume

Fully modulatedoil, gas or

combination burner

12

2

3

3

Take a look Inside

Page 6: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

Building Heat:

Fulton horizontal boilers can often be found inlarge building heating applications - such asschools, hospitals and government buildingswhere a reliable source of heat is crucial.Available in low pressure steam and hot waterversions.

Process Steam:

Food, plastic and chemical processing as well aspharmaceutical and bio-fuel production areonly a few of the many existing applicationsusing Fulton horizontal firetube boilers.

A Wide Range Of Applications

Clean Steam:

Hospitals and laboratories rely on a steadysupply of clean steam to operate sterilizers andautoclaves. Fulton horizontal boilers are alsoideal for large humidification demandapplications.

Commercial / Hotel Laundry:

Fulton horizontal firetube boilers are used in avariety of applications throughout manyindustries. Large scale laundry applications relyon Fulton horizontal boilers every day toprovide a steady supply of steam for ironers,presses and steam injection for washers andtunnels.

Page 7: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

Optional Ancillaries

Optional Ancillaries:

Fulton offers a complete line of high quality ancillaries for usewith any of our horizontal firetube boilers.

PLC Control System:

Fulton’s own boiler monitoring system with Human MachineInterface (HMI) is available upon customer’s request. Fulton’sPLC based system, including O2 trim, monitors the boileroperating status. It’s user friendly screen makes the boileroperating data easy to understand and simple to operate. ThePLC monitors and displays the following: boiler operatingpressure, pump operating status, boiler water level, burneroperating status, and stack temperature. The PLC is expandableto show additional operating and measurement data.

Enhanced Level & Pressure Controls:

Pressure differential transmitter level controller with 4-20maoutput to modulate a feedwater valve or pump, VFD is availableand highly recommended on boilers larger than 150 HP. Anupgrade to PID type pressure or temperature controls areavailable if tighter tolerances are required than standardpressure or temperature switches.

Automatic Blowdown Systems:

Blowdown protects the boiler from severe scaling or foulingproblems. Fulton’s automatic surface or bottom blowdownsystems have all the necessary components to keep boiler totaldissolved solid levels in check. Fulton can design energyrecovery systems that transfer heat from the blowdown waterto the feedwater or makeup water systems.

Other Optional Boiler Ancillaries:

• Thermal Shock Protection• Flue Gas Temperature Interlock• VFD Pump Controls• BMS Interfacing Controls• Stack Economizers

Page 8: Horizontal Firetube Boilersliterature.puertoricosupplier.com/032/MQ32150.pdf · Pressure differential transmitter level controller with 4-20ma output to modulate a feedwater valve

2009-0428

FBS_RB BRO

The Fulton Companies972 Centerville Road

Pulaski, NY 13142

Call: (315) 298-5121

Fax: (315) 298-6390

www.fulton.comFulton is a global manufacturer of steam,