Introduction and Quick Reference Guide
8/10/2019 Honeywell Internet Downloading Rev A
2/16
8/10/2019 Honeywell Internet Downloading Rev A
3/16
3
Table of Contents
What is Internet Downloading?...............................................................................................5
What Panels Can Be Downloaded Using This Method? .......................................................5
What Components are Required?...........................................................................................5
INTERNET COMMUNICATION ......................................................................................................... 6
INTRANET (PRIVATE LAN) COMMUNICATION........................................................................... 7
How Do I Set Up the Control Panel? .......................................................................................8
Vista-10P/Vista-25P/Vista-20P, FA130CP, FA148CP, FA168CPS Families........................................ 8
Vista-128/250BP, Vista-128/250FBP, FA1660C, FA1700C ................................................................. 9
Where Do I Get Help?.............................................................................................................14
8/10/2019 Honeywell Internet Downloading Rev A
4/16
4
8/10/2019 Honeywell Internet Downloading Rev A
5/16
5
What is Internet Downloading?
Internet downloading is uploading/downloading of control panel programming information
over the Internet or a Private local area network (Intranet) instead of using telephone lines.
This allows site maintenance independent of central station monitoring, and modification to
sites globally via the Internet or through a private LAN. Depending on the module used,
high speed (broadband) Internet connection from the protected premises is either hardwired
via cable service, DSL phone line, or fiber optic service (wired (i) modules), or wireless via theGSM/GPRS network (GSM modules). The main advantages of downloading over the Internet
are that it eliminates the need to tie up customers telephone lines, as well as improves the
speed at which the information can be delivered to and from the control panel. It is
estimated that the transfer of information using IP downloading is two-to-three times faster
than using conventional phone lines.
Currently, certain communication modules can be used for communicating either over the
internet to Alarmnet or to a 7810iR-ent receiver on a private LAN (internal intranet). These
include the 7845i-ent and 7847i-E. Private LAN refers to an internal network that includes
a 7810iR-ent receiver communicating directly with each communication device. In this
configuration, the messages do not go through Alarmnet. 7845GSM, 7845i-GSM, and 7847i
modules currently must communicate through Alarmnet (Internet communication).
What Panels Can Be Downloaded Using This Method?
This feature is currently available for the following control panels:
ADEMCO Controls
LynxR-I (Using the Communications port)
Vista-10P: Rev. 2.0 or higher (Using the ECP (keypad) bus)
Vista-10PSIA: Rev. 3.0 or higher (Using the ECP (keypad) bus)
Vista-15P: Rev. 5.2 or higher (Using the ECP (keypad) bus)
Vista-20P/Vista-20PSIA: Rev. 5.2 or higher (using the ECP (keypad) bus)
Vista-128BP/Vista-250BP (using the J8 trigger connector)
Vista-128FBP/Vista-250FBP (using the J2 trigger connector)
First Alert Professional Controls
ReadyGuard-RI (Using the Communications port)
FA130CP: Rev. 2.0 or higher (Using the ECP (keypad) bus)
FA130CPSIA: Rev. 3.0 or higher (Using the ECP (keypad) bus)
FA148CP/FA148CPSIA: Rev. 5.2 or higher (Using the ECP (keypad) bus)
FA168CPS/FA168CPSSIA: Rev. 5.2 or higher (using the ECP (keypad) bus)
FA1660C (using the J8 trigger connector)
FA1700C (using the J2 trigger connector)
What Components are Required?
System requirements depend upon whether you intend to communicate over the Internet or
over a Private LAN (Intranet).
8/10/2019 Honeywell Internet Downloading Rev A
6/16
6
INTERNET COMMUNICATION
For communication over the Internet, the following components are required:
At the Installation Site:
Alarmnet Internet Communication Module (e.g., 7845i-ent, 7845GSM, 7845i-
GSM, 7847i, 7847i-E, etc.)
7720P Programmer unlessusing Alarmnet Direct website for programming(website programming not available for 7845i-ent)
Internet Access and Cable/DSL/Fiber Modem (if using wired module)
Router (optional, if using wired communication module and connecting more than
one device to the internet)
Control Panel (one of the models listed earlier in this document)
Cable or appropriate Communication Kit: 4142TR Trigger Cable supplied with
7845i-ent; VBPCOMMKIT for Vista-128/250BP panels; VFBPCOMMKIT for
Vista-128/250FBP Series Control Panels (refer to diagrams at the back of this
document).
At the Downloading Office:
Internet Access and Cable/DSL/Fiber Modem
Router (optional, if connecting more than one device)
Computer Running Compass version 1.5.8.54A or higher*
* Available through My Web Tech. Go to:
http://www.security.honeywell.com/sce/
Under "Resources" Click on "MyWebTech."
Log in with username and password.
Click on "Software Downloads."
Click "Vista IP Intranet / Internet Installation Software."Click on "Internet Installation."
Here you will find a new version of Compass, and a document describing new
Communications Screen options required for Internet downloading (K10441).
Click on the application to download, and review the accompanying
information.
The system block diagram for Internet communication is shown in Figure 1.
INTERNET
ALARMNETROUTING CENTER
COMPASSVISTA PANEL
ALARMNETCOMMUNICATIONS
DEVICE
INTERNET FLOW DIAGRAM Internet_applications-2
Figure 1: Communicating Over the Internet
8/10/2019 Honeywell Internet Downloading Rev A
7/16
7
INTRANET (PRIVATE LAN) COMMUNICATION
For communication over an Intranet, the following components are required:
At the Installation Site:
Intranet Communication Module (7845i-ent, 7847i-E, etc.)
7720P Programmer unlessusing Alarmnet Direct website for programming
(website programming not available for 7845i-ent)
Control Panel (one of the models listed in the second paragraph of this document)
Cable or appropriate Communication Kit: 4142TR Trigger Cable supplied with
7845i-ent; VBPCOMMKIT for Vista-128/250BP Series panels; VFBPCOMMKIT
for Vista-128/250FBP Series panels (refer to diagrams at the back of this
document).
At the Downloading Office:
7810iR-ent IP Receiver
Internal Router
Computer Running Compass version 1.5.8.54A or higher*
Computer Running Compass Connect Data Server Application*
Computer Running Compass Connect Control Server Application*
* Available through My Web Tech. Go to:
http://www.security.honeywell.com/sce/
Under "Resources" Click on "MyWebTech."
Log in with username and password
Click on "Software Downloads."
Click "Compass.
Click on Interactive Download Document.
You will see the Software License Agreement. Once you agree to the license
terms, you will advance to the Interactive Download Documentpage.
From here, you can select the latest Compass version, the Control Server
software, and the Data Server software.
You can also access documents describing new Communications Screen options
required for Intranet downloading (K10441), Compass Connect Control Server
and Data Server applications, and the Installation and Setup Guide for these
applications (K10178). Click on the applications to download, and review the
accompanying information.
Note:Compass, the Compass Connect Data Server, and the Compass ConnectControl Server applications may all be installed on the same computer if desired. Ifthey are installed on one computer, the computer must have a fixed IP Address. Ifon separate computers, each computer will need a fixed IP Address.
8/10/2019 Honeywell Internet Downloading Rev A
8/16
8
The system block diagram for Intranet communication is shown in Figure 2.
VISTAPANELS
CONTROLSERVER
COMPASS
7845i-ent7847i-E
DATASERVER
7810iR-ent
Intranet_ApplicationINTRANET FLOW DIAGRAM
Figure 2: Communicating Over a Private LAN
How Do I Set Up the Control Panel?The system setup for downloading over IP depends upon whether you are using a Vista-
10P/15P/20P Series control panel, or a Vista-128/250BP or FBP Series control panel, and also
whether you are communicating over the Internet or a private LAN. For detailed wiring
connections, see Figures 3 and 4 and refer to the steps provided for the control panel you are
setting up.
Vista-10P/Vista-25P/Vista-20P, FA130CP, FA148CP, FA168CPS Families
These control panels communicate with the Internet/Intranet Communications Module over
the ECP (keypad) bus. To set up the control panel, do the following:
1. Connect the module to the control panel s ECP (keypad) terminals as you would a
keypad.
2. Internet users: For wired modules, connect the module to the internet via a
Cable/DSL/Fiber modem and router.
Intranet Users: For wired modules, connect the module to the intranet (LAN) via
the appropriate Ethernet connection.
3. Enable the module as a Long Range Radio in the control panel (programming
field *29) to enable alarm reporting and module supervision.
4. Set the module for address 3.
5. Program the module as required using one of the methods available (e.g., 7720P
programmer, Alarmnet Direct, etc.).
Note:Alarmnet Direct cannot be used to program the 7845i-ent.
6. Register the module with the Alarmnet, or with the associated 7810iR-ent (if
Private LAN) per the instructions in the communication modules Installation &
Setup Guide.
Note:The module must be registered before downloading or alarm reporting can
take place.
8/10/2019 Honeywell Internet Downloading Rev A
9/16
9
Vista-128/250BP, Vista-128/250FBP, FA1660C, FA1700C
These control panels communicate over the ECP (keypad) bus for central station reporting.
The Vista-128/250BP and FA1660C communicate over the control s J8 trigger connector for
uploading/downloading purposes, and the Vista-128/250FBP and FA1700C communicate
over the controls J2 trigger connector for uploading/downloading purposes. To set up the
control panel, do the following:
1. Connect the module to the control panel s ECP (keypad) terminals as you would a
keypad.
2. Connect the download trigger cable between the control panel trigger connector
and the communication module as applicable for your system (see Figures 3, 4, 5
and 6).
3. For wired units, connect the communication module to the Internet via a
Cable/DSL/Fiber modem and router, or directly to the Ethernet router if
communicating over a private LAN. For GSM units, physical connection to the
internet is not necessary.
4. Enable a device address for the communication module as a Long Range Radio
(LRR) in the control panels Device Programming Mode. This enables the control
panel to send central station reports over IP. For most modules, this address can
be between 01 and 30. For the7845i-ent, the address must be between 01 and 06.
5. Enable a second address for the communication module as a keypad in the
control panels Device Programming Mode if using either downloading over IP, or
the Remote Access web service. For the 7845i-ent, only legacy Symphony Remote
Access is available, and this address must be between 01 and 06. Do not
connect an actual keypad or any other device at this address.
6. Program the communication module as required using the 7720P programmer or
through the Alarmnet Direct web site. (Note:Alarmnet Direct cannot be used to
program the 7845i-ent.)
6a. Remember to program an address for communication as a LRR device (at the
appropriate prompt) with the same address programmed in Step 4. Also,
enable the Keypad Address(DW Addresson some modules) to tell thecommunication module what keypad address the communication module is
going to use for direct wire downloading or Remote Access web service (same
address as entered in Step 5).
Note: For the 7845i-ent, the DW Address and the address used for Remote
Access are two separate addresses, as the 7845i-ent can only be used with
legacy Symphony Remote Access. On other modules, the same address is
used for Remote Access and direct wire downloading.
7. Register the module with the Alarmnet, or with the associated 7810iR-ent (if
Private LAN) per the instructions in the communication modules Installation &
Setup Guide. The module must be registered before downloading or alarm
reporting can take place.
8/10/2019 Honeywell Internet Downloading Rev A
10/16
10
CAT5(4PAIR)
(BROADBANDCONNEC
TION)
7845i-ent
INTERNET/
INTRANET
COMMUNICATION
MODULE
(ONPREMISES)
TOPANELDATAIN TOPANELDATAOUT
HSIOAHSIOB
GND12V
RJ-11
RJ-45
private_
LAN_applications-2
WHITE
YELLOW
GREEN
RED
GRAY
4142TR
CABLE
K46
68WH
RJ1
1CABLE
VIOLET
BLACK
BLUE
BROWN
RED
GREEN
WHIT
E
BLAC
K
YELL
OW
TOPANELJ2
BLUE
NOCONNECTION
CO
NNECTIONSFORVISTA-FBPSERIES
WHITE
YELLOW
GREEN
RED
GRAY
4142TR
CABLE
K46
68WH
RJ1
1CABLE
VIOLET
BLACK
BLUE
BROWN
RED
GREEN
WHIT
E
BLAC
K
YELL
OW
TOPANELJ8
BLUE
NOCONNECTION
CO
NNECTIONSFORVISTA-BPSERIES
OR
COMPUTER
FORVISTA-BP
ANDFBPSERIES
CONTROLSONLY
RJ-45
RJ-45
RJ-45
RJ-45
CABLE/DSL/FIBER
MODEM
ALARMNET
ROUTINGCENTER
(OPTIONAL)
(OPTIONAL)
INTERNET
(O
NPREMISES)
COMPASS
VERSION
1.5.8.54A
784
5i-ent/7847i/7847i-EINTERNETAPPLICATION
INTERCONNECTIONDIAGRA
M
CABLE/DSL/FIBER
MODEM
R
OUTERWITH
FIREWALL
LINKSYSBEFSR41
(O
REQUIVALENT)
ROUTERWITH
FIREWALL
LINKSYSBEFSR41
(OREQUIVALENT)
GND(BLACK)
DATAOUT(YELLOW)DATAIN(GREEN)
12VDC(RED)
ECPBUS
GND
(+)
DI
DO
CONTROLPANELKEYPAD
TERMINALS
(ECPBUS)
Figure 3: 7845i, 7845i-ent, 7847i, 7847i-E Connections for Internet Application
8/10/2019 Honeywell Internet Downloading Rev A
11/16
11
NOTES
1.FOR
INSTALLATIONS,THELISTEDCLASS27720V2TRMUSTBEPOWEREDBYALISTEDUNINTERRUPTIBLE
POW
ERSUPPLY(UPS)WITHAUDIBLEANDVISUALINDICATIONSOFSWITC
HOVERTOSECONDARYPOWER.
2.FOR
INSTALLATIONS,ALISTEDCLASS27720V2TR-CNMUSTBEUSE
D.
3.COM
PASSANDTHECOMPASSCONNECTDATAANDCONTROLSERVERAPPLICATIONSMAYRUNONTWODIFFERENT
COM
PUTERSIFDESIRED.
4.THE
COMPASSCONNECTDATAANDCONTROLSERVERAPPLICATIONSMU
STBERUNNINGONTHENETWORKBEFORE
DOW
NLOADINGISATTEMPTED.
CAT5(4PAIR)
ETHERNET
7845i-ent
/7847i-EPRIVATELANAPPLICATION
(INTRANET)INTERCONNECTIONDIAGRAM
CAT5
(4PAIR)
ETHE
RNET
GND(BLACK)
DATAOUT(YELLOW)DATAIN(GREEN)
12VDC(RED)
ECPBUS
UNINTERRUPTIBLE
P
OWERSUPPLYWITH
24-HRSUPERVISION
7810iR-ent
IPRECEIVER
MODULE
CAT5CABLE
12VINGND
DATAIN
SERIALPRINRTER
DATAOUT
12VAUX
3(RX)
2(TX)
7(GND)
private_
LAN_applications-1
TOMAS
SERIAL
PRINTER
UL
CUL
ETHE
RNETNETWORK
7720V2TR
WHITE
YELLOW
GREEN
RED
GRAY
4142TR
CABLE
K4668
WH
RJ11CABLE
VIOLET
BLACK
BLUE
BROWN
RED
GREEN
WHITE
BLACK
YELLOW
TOPANELJ2
BLUE
NOCONNECTION
CONN
ECTIONSFORVISTA-FBPSERIES
WHITE
YELLOW
GREEN
RED
GRAY
4142TR
CABLE
K4668
WH
RJ11CABLE
VIOLET
BLACK
BLUE
BROWN
RED
GREEN
WHITE
BLACK
YELLOW
TOPANELJ8
BLUE
NOCONNECTION
CONNECTIONSFORVISTA-BPSERIES
GND
(+)
DIDO
RJ-45
OR
CONTROLPANELKEYPADTERMINALS
(ECPBUS)
COMPUTER
-COMPASSVERSION1.5.8.54A
-COMPASSCONNECTDATA
SERVER
-COMPASSCONNECTCON
TROLSERVER
FORVISTA-BPAND
FBPSERIES
CONTROLSONLY
7845i-ent
INTERNET/
INTRANET
COMMUNICATION
MODULE
(ONPREMISES)
TOPANELDATAINTOPANELDATAOUT
HSIOAHSIOB
GND12V
RJ-11
RJ-45
Figure 4: 7845i-ent, 7847i-E Connections for Intranet Application
8/10/2019 Honeywell Internet Downloading Rev A
12/16
12
Figure 5: 7845GSM Connections for Internet Application
G
ND
DATA
IN
DATAO
UT
+12V
GND(BLACK)
DATAOUT(YELLOW)
DATAIN(GREEN)
12VDC(RED)
WHITE
YELLOW
GREEN
RED
VIOLET
RED
GRAY
4142TR
CABLE
VIOLET
BLACK
BLUE
BROWN
TOPANELJ2
WHITE
YELLOW
GREEN
RED
GRAY
4142TR
CABLE
K4668WH
RJ11CABLE
VIOLET
BLACK
BLUE
BROWN
RED
GREEN
WHITE
BLACK
YELLOW
TOPANELJ8
BLUE
NOCONNECTION
ADDITIONALCONNECTIONS
FORVISTA-BPSERIES
ANDFA1660C
ADDITIONALCONNECTIONS
FORVISTA-FBPSERIES
ANDFA1700C
GND(+)DIDO
OR
C
ONTROLPANELKEYPADTERMINALS
(ECPBUS)
COMPUTER
ROUTERWITH
FIREWALL
LINKSYSBEFSR41
(OREQUIVALENT) R
J-45
RJ-45
CABLE/DSL/FIBER
MODEM
GSM
SERVICE
PROVIDER
AL
ARMNET
ROUTINGCENTER
(OPTIONAL)
INTERNET
7845GSMINTERNETAPPL
ICATION
INTERCONNECTIONDIA
GRAM
7845GSM-Internet-Application-V0
7845GSM
TB1
6 7 8511
1092 3 41
GSM
GPPS
WEB
MODE2
MODE1
RSSI
4100SM
8 7 6 5 4 3 2 1
FORVISTA-BP
ANDFBPSERIES
CONTROLSONLY
PARTSSUPPLIEDWITHDOW
NLOADERKITS:
VBPCOMKITFORVISTA-128B
P/FA1660C,
VFBPCOMKITFORVISTA-128
FBP/FA1700C.
K14394LF
25-PINTO
RJ-11CABLE
COMPASS
VERSION
1.5.8.54A
ORHIGHER
8/10/2019 Honeywell Internet Downloading Rev A
13/16
13
Figure 6: 7845i-GSM Connections for Internet Application
GND
DATAIN
DATAOUT
+12V
GND(BLACK)
DATAOUT(YELLOW)
DATAIN(GREEN)
12VDC(RED)
WHITE
YELLOW
GREEN
RED
VIOLET
RED
GRAY
4142TR
CABLE
VIOLET
BLACK
BLUE
BROWN
TOPAN
ELJ2
WHITE
YELLOW
GREEN
RED
GRAY
4142TR
CABLE
K4668WH
RJ11CABLE
VIOLET
BLACK
BLUE
BROWN
RED
GREEN
WHITE
BLACK
YELLOW
TOPANELJ8
BLUE
NOCONNECTION
G
ND(+)DIDO
OR
CONTROLPA
NELKEYPADTERMINALS
(ECPBUS)
COMPUTER
CABLE/DSLROUTER
WITHFIREWALL
LINKSYSBEFSR41
(OREQUIVALENT) R
J-4
5
RJ-45
CABLE/DSL/FIBER
MODEM
GSM
SERVICE
PROVIDE
R
A
LARMNET
ROUT
INGCENTER
(OPTIONAL)
INTERNET
7845i-GSMINTERNETAPPLICATION
INTERCONNECTIONDIAGRAM
7845
i-GSM-Internet-Application-V0
7845i-GSM
TB1
6 7 8511
1092 3 41
GSM
GPPS
WEB
MODE2
MODE1
RSSI
4100
SM
8 7 6 5 4 3 2 1
FORVISTA-BP
ANDFBPSERIES
CONTROLSONLY
K14394LF
25-PINTO
RJ-11CABLE
RJ-45
RJ-11
CAT
5(4PAIR)
(BROADBANDCONNECTION)
CABLE/DSLROUTER
WITHFIREWALL
LINKSYSBEFSR41
(OREQUIVALENT) R
J-45
RJ-45
(OPTIONAL)
(ONPREMISES)
FORBACKUP
REPORTING/DOWNLOA
DING
ADDITIONALCONNECTIONS
FORVISTA-BPSERIES
ANDFA1660C
PARTSSUPPLIEDWITHDO
WNLOADERKITS:
VBPCOMKITFORVISTA-128BP/FA1660C,
VFBPCOMKITFORVISTA-1
28FBP/FA1700C.
COMPASS
VERSION
1.5.8.54A
ORHIGHER
ADDITIONALCONNECTIONS
FORVISTA-FBPSERIES
ANDFA1700C
CABLE/DSL/FIBER
MODEM
8/10/2019 Honeywell Internet Downloading Rev A
14/16
14
Where Do I Get Help?
If you need technical help, call Alarmnet Technical Support between the hours of 8:00AM
and 8:00PM EST Monday through Friday at 1-800-222-6525. Press 1 for Technical Support.
8/10/2019 Honeywell Internet Downloading Rev A
15/16
15
8/10/2019 Honeywell Internet Downloading Rev A
16/16
K6126V1KK6126V1 6/07 R A
2 Corporate Center Drive, Melville, NY 11747Copyright 2007 Honeywell International Inc.