Top Banner
1 © Hitachi Power Systems America, Ltd. 2010. All rights reserved. Wednesday, May 12, 2010 Hitachi Power Systems America Copyright © 2010, Hitachi Power Systems America, Ltd., All rights reserved. FCURT Company Showcase Presentation 9:45 AM 10:05 AM Longboat Key Club and Resort Longboat Key, Florida
24

Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

May 22, 2018

Download

Documents

hoangdang
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 1© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Wednesday, May 12, 2010

Hitachi Power Systems America

Copyright © 2010, Hitachi Power Systems America, Ltd., All rights reserved.

FCURT Company Showcase Presentation

9:45 AM – 10:05 AM

Longboat Key Club and Resort

Longboat Key, Florida

Page 2: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 2© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Consolidated figures for FY 2008, ended March, 2009

Exchange rate: 101 yen to the US dollar

Revenue US $102 Billion (Power & Industrial Sector = 29%)

Head Office of Hitachi Ltd.

Stock Exchange Listings

of Hitachi Ltd.

Outside Japan: New York

In Japan: Tokyo, Osaka, Nagoya,

Fukuoka, Sapporo

Number of Employees 400,129

Consolidated Subsidiaries 943 manufacturing over 20,000 products

Tokyo, Japan

R&D Expenditure US $4.3 Billion (4.2% of revenue)

Hitachi, Ltd. Summary – as of March, 2009

Page 3: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 3© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Europe

Companies: 141

Employees: 11,056

Revenues: $9.2 Billion

Japan

Companies: 403

Employees: 260,677

Revenues: $60 Billion

Asia including China

Companies: 275

Employees: 107,647

Revenues: $19.5 Billion

North America

Companies: 79

Employees: 14,867

Revenues: $9.1 Billion

OtherCompanies: 45

Employees: 5,882

Revenues: $4.3 Billion

As of March 31, 2008 (Revenue as of March 31, 2009 in FY 2008)

Regional Headquarters in Americas, Europe, China, and Asia

Hitachi at a Glance

HITACHI Credit Rating

“BBB+” S&P Rating

“A3” Moody’s Rating

Page 4: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 4© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Hitachi Power Systems America Summary

Established in 2005

Headquartered in Basking Ridge, New Jersey

Fully Integrated Power Supplier

Steam Generators

Turbines

Air Quality Control Systems

After Market Services

Renewables

Nuclear

Single Point of Responsibility

Sales & Marketing

Technology

Project Execution

Engineering/Design

Procurement

Profit and Loss

Page 5: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 5© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

President & CEO

H. Bartoli

•Finance- S. Lee

•Legal – K. McEwen

•HR- L. DiDonato/J. Wladich

•IT – D. Kovalsky

QA/QC

T. Staed

Commercial & Strategic

Operations

M. Seshamani

Strategic Planning

Proposal Development

Cost Estimating

Project Operations

W. Buffa

Project Management

Project Control

Construction

Management

Procurement

Engineering

A. Kukoski

Engineering

Design

Service

BHK Engineering

R&D

Sales & Marketing

D. Brozek

Field Sales

Marketing

Product Sales

Nuclear Group

J. Yoshinari / T. DiFransico

Plant

Commissioning/Start-up

After Market

Services

B. Studley

HPSA Organization

Administration

S. Davidek

T. LaBar

Y. Ross

M. Hermo

H. Horwath

Page 6: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 6© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Renewables

FGD SCR

Nuclear Reactors

Hydro EquipmentSteam Generators

Vertically Integrated

Product Line-up for

Power Generation

Facilities

HPSA Charter – Total Energy Company

Turbines

Substation Equipment

Page 7: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 7© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Steam Generators

Utility Boilers

• Subcritical

• Supercritical

Turbines

Steam Turbines

• Subcritical

• Supercritical

• Nuclear

• Combined Cycle

Gas Turbines

• H-15

• H-25

Hydro Turbines

Products and Services for USA Market

Page 8: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 8© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Products and Services for USA Market

AQCS

WFGD

SCR

Catalyst

Low NOx Burners

Complete Air Quality Control Systems

EPC / Extended Scope

Turnkey Services

Wrap-around guarantees for total performance and schedule

Nuclear

Hitachi 40% owner of GEH focused on ABWR and ESBWR technology

EPC of ABWR project

Renewables / Energy Conservation

Wind

Solar

Hydro

Smart Grid

Carbon Capture Sequestration

Aftermarket Services for Boilers, Turbines (MD&A) and AQCS

Page 9: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 9© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Extended Scope and Wrap-Around Guarantees

More than 65% of high efficient power stations

can be supplied by Hitachi Companies

Boiler

Turbine/Generator

DeNOx

FGD

Engineering

BOP

I & C System

Civil works

Infrastructure

BOP others

Total Fossil

Plant Cost

FGD

ESP/FF

DeNOx

Boiler

Turbine/ Generator

Page 10: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 10© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Hitachi’s Value to North American Energy Business

EPCOR / Genesee Project 495 MW

MEC / Walter Scott, Jr. Energy Center 850 MW

EPCOR / Keep Hills Project 495 MW

Exelon Victoria County 2 x 1500 MW (ABWR)

Seminole / Palatka 1&2 2 x 750 MW (SCR Retrofit)

EPC Projects

EPCOR / Genesee Project 495 MW

MEC / Walter Scott, Jr. Energy Center 850 MW

EPCOR / Keep Hills Project 495 MW

Duke / Cliffside 825 MW

WE / Elm Road 2 x 660 MW

Boiler Projects

Page 11: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 11© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Hitachi’s Value to North American Energy Business

EPCOR / Genesee Project 495 MW

MEC / Walter Scott, Jr. Energy Center 850 MW

WE / Elm Road 2 x 660 MW

EPCOR / Keep Hills Project 495 MW

E.ON US / Trimble County 750 MW

CLECO / Rodemacher 600 MW

Chase / Las Brisas Energy Center 660 MW

Turbine Generators

CPS Energy / Spruce 750 MW

E.ON US / Trimble County 750 MW

LS Power / Sandy Creek 900 MW

WE / Elm Road 2 x 660 MW

Boiler Feed Pump Turbines

Page 12: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 12© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Hitachi’s Value to North American Energy Business

Minn. Power / Boswell AQCS Retrofit 375 MW

Ameren FGD Units (Alliance Agreement) 360-590 MW

Seminole / Palatka 1&2 SCR Retrofit 2 x 750 MW

Duke / Cliffside SCR 825 MW

PSE&G / Hudson SCR Retrofit 600 MW

East Kentucky SCR Retrofit 250 MW

E.ON US / Trimble County SCR System 750 MW

Confidential SCR Retrofit 3 x 850 MW

Multiple US Utilities Catalyst i.e. Southern and AEP

Fleet Contracts

AQCS

Significant Technology Presence in Market

NYPA / Gilboa 1160 MW

Over 11,000 MW of installed Hydro Turbines in the US

inclusive of 8,000 MW of Pump Storage Turbines

Hydro

Page 13: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 13© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Once-Through, Benson

853MW

5,579,000 lb/h

3,803 psig/ 1057 ゚F / 1103 ゚F

PRB

Boiler Type :

Generator Output :

Main Steam Flow :

Steam Conditions :

Commercial Operation : June 2007

Fuel :

MidAmerican Energy Company

Walter Scott, Jr. Energy Center Unit 4

Latest Hitachi Boilers in North America

GUARANTEE

VALUES

PERFORMANCE

TEST

Heat Rate 8,899 Btu/kWh 8,697 Btu/kWh

MW’s 790,000 814,904

Six supercritical variable pressure boilers awarded to Hitachi in North America in

the last eight years.Three already in operation.

Better Heat Rate / Output Guarantee

Power Plant of the Year 2007

Page 14: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 14© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Power Magazine Top Plant of the Year - 2009

2009 Power Magazine Top Plant Award

In 2006, Hitachi Power Systems America, Ltd. was awarded an EPC

contract through the competitive bidding process by Seminole Electric

Cooperative, Inc. (SECI) for the SCR System retrofit on both Units 1 and 2

(750MW each) located in Palatka, Florida. As a non-profit cooperative,

Seminole seeks the most cost effective solution to meet its long-term

objective of environmentally friendly and sustainable operation. Seminole

decided installing these SCR Systems would be the best option to meet

the Clean Air Interstate Rule requirements……..

Page 15: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 15© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

on behalf of the Seminole staff and our Member Cooperatives to thank you, the Hitachi Power Systems America staff, and your partners for a superb job in supporting and installing the Selective Catalytic Reduction (SCR) System

We, and our Members were pleased to learn that SGS’s Pollution Control

Project (in which the SCR installation was a major contributor) received a

prestigious award from Power Magazine as one of the world’s top coal-fired

plant projects; distinguishing itself as an industry leader

Power Magazine Top Plant of the Year

Page 16: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 16© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Seminole SCR Scope Depiction – SCR Area

Boiler

AIG

MixersSCR

Catalyst (Two Layers)

ESP

Diverter Damper Air Heater Upgrades

Seminole Unit 1 & 2 SCR Retrofit

HPSA Contract 52-1017-0000

Structural Steel

Existing: Green

New: Other Color

Page 17: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 17© Hitachi Power Systems America, Ltd. 2010. All rights reserved.

Seminole Unit 1 & 2 SCR Retrofit

HPSA Contract 52-1017-0000

All Shown Equipment is New

and in HPSA’s Scope

Seminole SCR Scope Depiction – U2A System

Page 18: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 18© Hitachi Power Systems America, Ltd. 2010. All rights reserved.Copyright © Hitachi,Ltd.2009 All rights reserved

SEMINOLE SCR RETROFIT

START

OF THE

FIRST

OUTAGE

Page 19: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 19© Hitachi Power Systems America, Ltd. 2010. All rights reserved.Copyright © Hitachi,Ltd.2009 All rights reserved

SEMINOLE SCR RETROFIT

Before

After (End of First Outage)

Page 20: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 20© Hitachi Power Systems America, Ltd. 2010. All rights reserved.Copyright © Hitachi,Ltd.2009 All rights reserved

SEMINOLE SCR SITE PHOTOS

PROGRESS WORK

OCCURING

BETWEEN

END OF FIRST OUTAGE

AND

START OF THE

SECOND OUTAGE

Page 21: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 21© Hitachi Power Systems America, Ltd. 2010. All rights reserved.Copyright © Hitachi,Ltd.2009 All rights reserved

SEMINOLE SCR SITE PHOTOS

PROGRESS WORK

OCCURING

BETWEEN

END OF FIRST OUTAGE

AND

START OF THE

SECOND OUTAGE

Page 22: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 22© Hitachi Power Systems America, Ltd. 2010. All rights reserved.Copyright © Hitachi,Ltd.2009 All rights reserved

SEMINOLE SCR SITE PHOTOS

COMPLETE

SCR

ERECTED

Page 23: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 23© Hitachi Power Systems America, Ltd. 2010. All rights reserved.Copyright © Hitachi,Ltd.2009 All rights reserved

SEMINOLE SCR SITE PHOTOS

COMPLETE

U2A SYSTEM

ERECTED

Page 24: Hitachi Power Systems America - SCOAR Company Showcase.pdfFGD SCR Nuclear Reactors ... Boiler Feed Pump Turbines. ... the Hitachi Power Systems America staff, and your partners for

Proprietary 24© Hitachi Power Systems America, Ltd. 2010. All rights reserved.