Category 5 Hurricane Wind Damage FEA stress analysis Highway Sign 10/29/2017 rev B Don Blanchet 3B Associates [email protected] Prepared for: F L - DOT 1
9

Highway wind damage

Jan 21, 2018

Download

Engineering

Don Blanchet
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Highway wind damage

Category 5 Hurricane Wind DamageFEA stress analysis

Highway Sign

10/29/2017 rev BDon Blanchet

3B Associates

[email protected]

Prepared for: FL-DOT1

Page 2: Highway wind damage

Solidworks 2018 model

2

Steel construction welded and boltedSteady 200 MPH wind loading

Page 3: Highway wind damage

FEA mesh – 450,000 d.o.f.

3

Page 4: Highway wind damage

Boundary Conditions

4

Bolted to heavyConcrete supports2 places

Page 5: Highway wind damage

Results: permanent deformation – 2.89 inches

5

Page 6: Highway wind damage

Results: peak stress

6

Steel yield pointExceeded

Near base of verticalsupports

Page 7: Highway wind damage

Conclusions

Simple static analysis predicts failure at a steady wind pressure.

More complex dynamic analysis recommended CFD turbulence calculations to predict vibration response due to downstream vortex shedding.