Category 5 Hurricane Wind Damage FEA stress analysis Highway Sign 10/29/2017 rev B Don Blanchet 3B Associates [email protected] Prepared for: F L - DOT 1
Category 5 Hurricane Wind DamageFEA stress analysis
Highway Sign
10/29/2017 rev BDon Blanchet
3B Associates
Prepared for: FL-DOT1
Solidworks 2018 model
2
Steel construction welded and boltedSteady 200 MPH wind loading
FEA mesh – 450,000 d.o.f.
3
Boundary Conditions
4
Bolted to heavyConcrete supports2 places
Results: permanent deformation – 2.89 inches
5
Results: peak stress
6
Steel yield pointExceeded
Near base of verticalsupports
Conclusions
Simple static analysis predicts failure at a steady wind pressure.
More complex dynamic analysis recommended CFD turbulence calculations to predict vibration response due to downstream vortex shedding.
7
8
9