Top Banner
“Bringing Physical & Electronic solutions together” 0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together
14

High Security Group Presentation 6.10.08

Feb 10, 2017

Download

Business

Richard Holmes
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: High Security Group Presentation 6.10.08

“Bringing Physical & Electronic solutions together”

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

Page 2: High Security Group Presentation 6.10.08

National Fire & Security ConvergenceSpecialists

• High Security Physical Ltd• (Manufacturing Plant in Birmingham)• High Security Ltd• Modular Doors Ltd• Total Fire Services Ltd 25 fire risk assessors• STAR LTD BS 7858 Vetting & Recruitment Company• 24 hour engineering central service & alarm response

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

Page 3: High Security Group Presentation 6.10.08

Security ConvergenceSpecialists

• Bespoke Banking ATM protection physical attacks• Retail Loss prevention Electronic tagging IP CCTV• Commercial & Industrial Integrated systems• Personnel vetting & accreditation business

consultancy• Fire Risk assessments• Fire alarm design Installation0210/2008 High Security group Ltd Bringing Physical &

Electronic Security Together

Page 4: High Security Group Presentation 6.10.08

High Security Physical Ltd• Perimeter guard (electronic & physical protection)• High Security Perimeter Fencing• High Security Steel doors• High Security pods• Roller shutters• High speed doors• Grills/bars• Aluminium window shutters• Insulated roller garage doors

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

Page 5: High Security Group Presentation 6.10.08

High Security Ltd

• Project Management• Monitored Intruder alarms• IP Digital CCTV Solutions• Access Control• Fire Alarms• Fire Extinguishing services• Door entry systems

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

Page 6: High Security Group Presentation 6.10.08

High Security Ltd

• Fire Risk Assessment• Fire Alarm Design L1-L5• Fire Alarm Installation• Supply & Commission• Fire Alarm Maintenance• Fire Extinguishing services• Emergency Lighting Design & Installation & Maintenance

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

Page 7: High Security Group Presentation 6.10.08

High Security Ltd

• Turn Key Security Solutions• Access Control• CCTV• Intruder• Door Entry Systems

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

Page 8: High Security Group Presentation 6.10.08

Risk Assessment

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

SYSTEM DESIGN - RISK ASSESSMENT

PREMISES ACTIVITIESCONTENTS OF HOME/BUSINESS

Q Do you consider your home/business to be classed as a target for thieves? YES

TYPE OF STOCK/PROPERTY

Q Is your stock/property easy to dispose? YES

Q Does your stock/property pose an attraction to a burglar? YES

BULK/SIZE OF STOCK/PROPERTY

Q Is the stock/property easy to Remove/Transport? YES

Q Is there easy Access to premises (to aid removal of stock/property)? NO

STORAGE/CONTROL

Q Are High Value Goods quarantined? YES

Q Are High Value Goods restricted to certain personnel? YES

THEFT HISTORY

Q Have you been broken into before? YES

1SYSTEM DESIGN GRADE - based on risk assessment above 2

PD 6662 En 50131

Page 9: High Security Group Presentation 6.10.08

• Q Maximum probable value in a single loss? • • Q Daily Turnover of business? • • Q How long will it take to restock/resume normality? • • Projected loss of earnings until normal operation • • Q Cost Of Insurance Excess • • Q Cost By Vandalism Of Contents • • Total Cost of Burglary

• SYSTEM DESIGN GRADE - based on cost of loss• 2

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

CONSEQUENTIAL COST OF LOSS -

Page 10: High Security Group Presentation 6.10.08

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

Bigger Picture -LOCALITY

High crime risk area

Proximity of adjacent occupied premises

Presence of adjacent building to aid attack

Speed & quality of response to IAS

EXISTING SECURITY

Quality & extent of physical devices

Quality & extent of existing IAS

THEFT HISTORY

Methods of attack in previous break-ins

LOCAL LEGISLATION/REGULATION

Fire/Safety Requirements that may affect IAS design

Building Construction that may affect IAS design

SECURITY ENVIRONMENT

Location of Building - Rural or Urban area

Page 11: High Security Group Presentation 6.10.08

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

TIME -

Response

Police 20 MinutesKey Holder 20 MinutesManned Security 5 MinutesRemote Viewing 2 minutes + police/key-holderMSL in relation to the above

(Maximum single loss)

Page 12: High Security Group Presentation 6.10.08

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

TIME DELAY vs. LOSS -

• Physical Perimeter 2 minutes no alarm• Physical openings 30 seconds to 10 minutes• LPCB • Electronic detection ACPO delay

Page 13: High Security Group Presentation 6.10.08

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

PD6662 Grade 4 Security

Delay & DeterPhysical Perimeter 8 minutes with alarm• Physical openings 8 minutes with alarm• LPCB ,NSI, ACPO, SSAIB,Insurance Companies• Physical detection systems

Page 14: High Security Group Presentation 6.10.08

0210/2008 High Security group Ltd Bringing Physical & Electronic Security Together

PD6662 Grade 4 Security

Integrated Electronic & physical products