Page 1: High Performance Concrete Building Design Insulating Concrete ...

CICFI.org

High Performance Concrete Building Design Insulating Concrete Forms – a solution to current and future Energy and Building Codes in North America

Kevin Davis Director of Sales

Quad-Lock Building Systems

Page 2: High Performance Concrete Building Design Insulating Concrete ...

CICFI.org

A consortium operating under the auspices of the Ontario Ready Mix Association.

Page 3: High Performance Concrete Building Design Insulating Concrete ...

Environmental Role of Buildings

FACT #1: Our buildings consume the largest percentage of our total energy use

Source: US Energy Information Agency

Page 4: High Performance Concrete Building Design Insulating Concrete ...

Environmental Role of Buildings

FACT #2: The “Appetite for Energy” of our buildings is driven

50% by space heating & cooling demands

Source: US Energy Information Agency

Residential Building

Page 5: High Performance Concrete Building Design Insulating Concrete ...

Current Residential Energy Code Adoption Status

Page 6: High Performance Concrete Building Design Insulating Concrete ...

Can We Change Cultural Priorities?

Change a culture that is

focused on the glittering

amenities?

Change a culture that is

focused on “first-cost” vs

total cost of ownership?

Not very likely!

Page 7: High Performance Concrete Building Design Insulating Concrete ...

The Secret Is In Our Name

“Insulating” “Concrete” “Forms”

Two layers of high value EPS insulation provide continuous thermal barrier

Reinforced concrete provides durable structure & protection of occupants

Lightweight EPS forms are easily shaped & adapted to architectural designs

Page 8: High Performance Concrete Building Design Insulating Concrete ...

Two ICF Use-Categories:

• Two-sided ICFs

Vertical concrete structures Flat, pitched or tilt-up concrete structures

• One-sided ICFs

Page 9: High Performance Concrete Building Design Insulating Concrete ...

Strategic use of 3 unique

qualities:

9

Zero Porosity

Concrete Air Barrier

High R-Value &

Unbroken Insulation

Layers

High Mass for

Thermal Storage

9

How do ICFs control heat gain/loss?

Page 10: High Performance Concrete Building Design Insulating Concrete ...

ICF vs. Neighbors

Page 11: High Performance Concrete Building Design Insulating Concrete ...

ICF vs. Neighbors

11

Page 12: High Performance Concrete Building Design Insulating Concrete ...

ICF Progress in the Market

12

Page 13: High Performance Concrete Building Design Insulating Concrete ...

Available Insulation Options

Page 14: High Performance Concrete Building Design Insulating Concrete ...

ICF Complete Concrete Building Enclosure

Walls Floors

Roofs

14

© 2013 Quad-Lock Building Systems, Ltd

Page 15: High Performance Concrete Building Design Insulating Concrete ...

Desired Characteristics of Building Shells

$$ Yes Yes

Desired Characteristics ** Code Mandated

Moisture Resistant**

Wind Resistant**

Seismic Resistant**

Thermal Continuity**

Fire Resistant**

Safe/Non-toxic**

Impact Resistant

Adaptable to Design &

Utilities

$$ $ Yes Yes

$ $$ $$ Yes

$$ Yes Yes

$$ $ Yes Yes

$ $$ $$ Yes

Yes Yes Yes Yes

Yes Yes

Wood

Frame

Steel

Frame

Conv.

Concrete

ICF

Concrete

15

Page 16: High Performance Concrete Building Design Insulating Concrete ...

ICF/Concrete Wall Reinforcement

Prescriptive Designs

to 150 mph (all exposures)

IRC Prescriptive Designs

16

Page 17: High Performance Concrete Building Design Insulating Concrete ...

Lateral Strength Comparison

Wood Frame

ICF & Concrete

Concrete % Advantage

Global Lateral Stiffness (lbs/in)

18,500 708,000 +3,827%

Load at First Major Damage (lbs)

3,500 8,500 +243%

Displacement at First Major Damage

(in) 0.51 0.06 +850%

Maximum Lateral Resistance (lbs)

4,553 34,254 +752%

Displacement at Max. Lateral Resist.

(in) 0.89 2.66 +299%

Test performed by PCA based on ASTM E564-95

17

Page 18: High Performance Concrete Building Design Insulating Concrete ...

Relevant Codes and Standards: USA

International Residential Code • Chapters 3, 6 & 11

International Building Code • Chapters 16 & 19

International Energy Conservation

Code

ASCE 24-05 • Flood Resistant Design & Construction

ACI 318 • Building Requirements for Structural Concrete

18

Page 19: High Performance Concrete Building Design Insulating Concrete ...

Relevant Codes and Standards: Canada

National Building Code of Canada or Provincial Codes • Parts 3, 4, 5 & 9

• Post-Disaster Category

CAN/CSA A23.3

• Design of Concrete Structures

ASCE 24-05 • Flood Resistant Design & Construction

19

2011 National Model Energy Code for

Buildings

ASCE 7 • Minimum Design Loads for Buildings

Page 20: High Performance Concrete Building Design Insulating Concrete ...

Disaster Resistant ICF/Concrete Designs

20

Page 21: High Performance Concrete Building Design Insulating Concrete ...

Community Centres Custom Homes

Elevated Single Family Residence

Schools

ICF Designs For Efficiency and Survivability

Building Types

21

Page 22: High Performance Concrete Building Design Insulating Concrete ...

Construction Time With ICF.

Thermal Resistance.

ICFs are considered by ICC and IECC as mass walls

with continuous insulation

Typical whole wall ICF assembly has an R value of

R24

ICFs exceed the requirements for all climate zones

for commercial thermal envelopes above and below

grade.

Page 23: High Performance Concrete Building Design Insulating Concrete ...

CICFI.org

Kevin Davis Director of Sales / Quad-Lock Building Systems Email: [email protected] Phone: (604)590-3111 extension 244 Mobile: (604)314-1065