UP DN UP A 1 A101 SIM 1 A101 SIM NOT USED - DOOR TAG NOT USED - WINDOW TAG SECTION TAG ELEVATION TAG DETAIL TAG 0 A1.1 NOTE TAG COLUMN LINE WALL TAG 101 1 15 T C E T I H C R A D E R E T S I G E A N I L O R A C H T S T A T E O F S O U R DP3 ARCHITECTS LTD. GREENVILLE, SC B - 84017 MARGARETTA LAWRENCE TERRY GREENVILLE, SC 7297 A N I L O R A C H T S T A T E O F S O U T C E T I H C R A D E R E T S I G E R Copyright : These Drawings are the property of DP3 Architects, Ltd., and reuse on any other project without written permission will result in legal action. Seal Project Project Number Drawn By Checked By Date Revisions Drawing DP3 ARCHITECTS, LTD. 211 East Broad Street T. 864.232.8200 F. 864.232.7587 Greenville, SC 29601 www.DP3architects.com 28 APR 2014 14153 13 MAR 2014 LJD Hendrix Center Renovation Panda Express and Tiger Grill MLT T1.1 Cover Sheet Hendrix Student Center, South Palmetto Boulevard Clemson, SC Hendrix Food Court Renovation Panda Express and Tiger Grill DESIGN AND ENGINEERING TEAM INDEX OF DRAWINGS DRAWING LIST SHEET NUMBER SHEET NAME CURRENT REVISION CURRENT REVISION DATE Cover Sheet T1.1 Cover Sheet Architecture A1.1 Demolition Plan and Floor Plan A2.1 Reflected Ceiling Plan A6.1 Millwork Plans, Elevations, and Details Plumbing P1.1 Partial Plumbing Floor Plan & Schedule Mechanical M1.1 Partial HVAC Plan & Schedules Electrical E0.1 Electrical Legend and Schedules E1.1 Electrical Lighting and Power Plans Food Service FS1.1 Panda Express & Tiger Grill Food Service Drawings DRAWING SYMBOL LEGEND Owner Clemson University 191 Old Greenville Highway, Gentry Hall Clemson, SC 29634-5952 Contact: Channon Chambers P: 864.643.6216 F: 864.656.0167 Architect DP3 Architects 211 E. Broad Street Greenville, SC 29601 Contact: Meg Terry, AIA P: 864.232.8200 x1031 F: 864.232.7587 Electrical Engineer Burdette Engineering, Inc. 102 Pilgrim Road Greenville, SC 29607-5702 Contact: Don Burdette, PE P: 864.297.8717 F: 864.297.8719 Mechanical/Plumbing Engineer Peritus Engineers and Associates PO Box 16598 Greenville, SC 29606 Contact: Jody Parker, PE P: 864.277.8287 F: 864.277.8290 2007 EDITION ASHRAE 90.1: INTERNATIONAL ENERGY CONSERVATION CODE: 2009 EDITION INTERNATIONAL FIRE CODE: INTERNATIONAL BUILDING CODE: INTERNATIONAL PLUMBING CODE: 2012 EDITION 2012 EDITION 2012 EDITION 13 MARCH 2014 13 MARCH 2014 MARGARETTA L. TERRY, AIA CLEMSON UNIVERSITY HENDRIX STUDENT CENTER FOOD COURT CLEMSON, SOUTH CAROLINA DATE: COMPLETED BY: DRAWINGS DATED: PROJECT DESIGNED IN ACCORDANCE WITH: PROJECT: INTERNATIONAL MECHANICAL CODE: 2012 EDITION VICINITY MAP SITE GENERAL PROJECT NOTES A THE TERM "WORK" AS USED IN THESE NOTES SHALL INCLUDE ALL PROVISIONS AS DRAWN OR SPECIFIED IN THESE DOCUMENTS AS WELL AS ALL OTHER PROVISIONS SPECIFICALLY INCLUDED BY THE OWNER IN THE FORM OF DRAWINGS, SPECIFICATIONS, AND WRITTEN INSTRUCTIONS AND APPROVED BY THE ARCHITECT. B THE TERM "CONTRACTOR" AS USED IN THESE NOTES SHALL REFER TO THE GENERAL CONTRACTOR OR TO THE SUB-CONTRACTORS. THE OWNER MAY ELECT TO CONTRACT DIRECTLY WITH A SUB-CONTRACTOR FOR ANY PART OF THE WORK. C SCOPE OF WORK: THE CONTRACTOR SHALL INCLUDE AND PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, TRANSPORTATION, AND PAY ALL EXPENSES INCURRED IN THE PROPER COMPLETION OF WORK UNLESS SPECIFICALLY NOTED TO BE THE WORK OF OTHERS. CONTRACTOR SHALL PERFORM ALL WORK NECESSARY FOR PRODUCING A COMPLETE, HABITABLE PROJECT, INCLUDING BUT NOT LIMITED TO SITE WORK, ARCHITECTURAL, ELECTRICAL, PLUMBING AND HVAC. D BEFORE CONSTRUCTION BEGINS, THE CONTRACTOR SHALL VISIT THE SITE TO VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT, IN WRITING, OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THEWORK AND SHALL BE RESPONSIBLE FOR SAME. E IF THE CONTRACT DRAWINGS ARE FOUND TO BE UNCLEAR, AMBIGUOUS OR CONTRADICTORY, THE CONTRACTOR MUST REQUEST CLARIFICATION FROM THE ARCHITECT IN WRITING BEFORE PROCEEDING WITH THAT PART OF THE WORK. F THE ARCHITECT SHALL BE AVAILABLE TO VISIT THE SITE WHEN REQUESTED. IF A CONDITION EXISTS THAT REQUIRES OBSERVATION OR ACTION BY THE ARCHITECT OR STRUCTURAL ENGINEER, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT. G CONTRACTOR SHALL BE FAMILIAR WITH PROVISIONS OF ALL APPLICABLE CODES AND SHALL INSURE THE COMPLIANCE OF THE WORK WITH ALL LOCAL, STATE AND FEDERAL CODES, TRADE STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. IN THE EVENT OF CONFLICT BETWEEN LOCAL, STATE AND NATIONAL CODES, THE MORE STRINGENT SHALL GOVERN. BEFORE COMMENCING WORK NOT SHOWN IN DOCUMENTS, BUT REQUIRED TO ACHIEVE FULL COMPLIANCE WITH CODES, CONTRACTOR SHALL NOTIFY ARCHITECT. H THESE DOCUMENTS DO NOT INCLUDE THE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. SAFETY, CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, COMPLIANCE WITH STATE AND FEDERAL REGULATIONS REGARDING SAFETY AND COMPLIANCE WITH REQUIREMENTS SPECIFIED IN THE OWNER/CONTRACTOR CONTRACT IS, AND SHALL BE, THE CONTRACTOR'S RESPONSIBILITY. I CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES AND SAFETY PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK. J OWNER SHALL PAY ALL TAXES, SECURE ALL PERMITS AND PAY ALL FEES INCURRED IN THE COMPLETION OF THE PROJECT, INCLUDING BUT NOT LIMITED TO BUILDING PERMITS, WATER, ELECTRIC AND TELEPHONE SERVICE CONNECTION IMPACT FEES, CERTIFICATE OF OCCUPANCY, AND INSPECTIONS. K INSURANCE: WORKMEN'S COMPENSATION, AS REQUIRED BY LAW, AND PUBLIC LIABILITY SHALL BE CARRIED BY THE CONTRACTOR. L GUARANTEE: THE CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL MATERIALS, AND WORKMANSHIP FURNISHED OR INSTALLED BY HIM OR HIS SUBCONTRACTORS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE AND SHALL REPLACE ANY DEFECTIVE WORK WITHIN THAT PERIOD WITHOUT EXPENSE TO THE OWNER AND PAY FOR ALL DAMAGES TO OTHER PARTS OF THE BUILDING RESULTING FROM DEFECTIVE WORK OR ITS REPAIR. THE CONTRACTOR SHALL REPLACE DEFECTIVE WORK WITHIN TEN (10) DAYS AFTER IT IS BROUGHT TO HIS ATTENTION. M PROTECTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK AND THAT OF HIS SUBCONTRACTORS FOR LOSSES AND DAMAGES TO EQUIPMENT, TOOLS AND MATERIAL USED IN CONJUNCTION WITH THE WORK AND FOR ACTS OF HIS EMPLOYEES. N CLEANING UP: THE CONTRACTOR SHALL AT ALL TIMES KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH AND AT THE COMPLETION OF THE WORK THE CONTRACTOR SHALL REMOVE ALL RUBBISH, IMPLEMENTS, AND SURPLUS MATERIALS AND LEAVE THE BUILDING CLEAN, WITH PAINTED AND WOOD SURFACES CLEAN, ALL FLOORS WAXED AND/OR POLISHED AS SPECIFIED, AND ALL GLASS AND MIRRORS CLEANED AND POLISHED. O CONTRACTOR IS TO PROVIDE TO THE OWNER A LIST OF ALL SUBCONTRACTORS USED, COMPLETE WITH ADDRESSES, PHONE NUMBERS AND COPIES OF ALL WARRANTIES AND OPERATIONS AND MAINTENANCE MANUALS. P SUBWAY, DINING AREA, AND POD SHALL REMAIN OPEN AND ACCESIBLE DURING CONSTRUCTION. Q PROVIDE DUST PARTITIONS DURING CONSTRUCTION. R CONTRACTOR IS RESPONSIBLE FOR INSALLATION AND UTILITY CONNECTION OF ALL KITCHEN EQUIPMENT. GENERAL DEMOLITION NOTES A ALL MATERIALS THAT HAVE BEEN DEMOLISHED SHALL BE REMOVED IMMEDIATELY AND DISPOSED OF PROPERLY. NO DEMOLISHED MATERIALS SHALL BE STOCKPILED ON SITE. B THE CONTRACTOR SHALL MAKE A PERSONAL INSPECTION OF THE SITE AND INCLUDE EXECUTING EVERYTHING REQUIRED BYTHE DRAWINGS AND SPECIFICATIONS. NOTIFY THE ARCHITECT IN WRITING OF ANY INCONSISTENCIES IN THE DRAWINGS. C PROTECT OWNER'S PROPERTY AND PERSONS AT ALL TIMES. THIS SECTION INCLUDES ALL ITEMS AND SERVICES NECESSARY TO DEMOLISH OR DISMANTLE AND REMOVE ALL WALLS, EQUIPMENT, PIPING AND APPURTENANCES WHICH WILL INTERFERE WITH NEW CONSTRUCTION. ALL ITEMS TO BE REMOVED SHALL BE COORDINATED WITH NEW CONSTRUCTION. D ANY ITEMS NOT SHOWN TO BE DEMOLISHED THAT ARE DAMAGED SHALL BE REPAIRED BY THE CONTRACTOR. E COORDINATE ANY SYSTEMS SHUTDOWNS WHICH MAY BE REQUIRED WITH THE OWNER. F THE CONTRACTOR SHALL CONTROL AND LIMIT DUST RESULTING FROM DEMOLITION AND PREVENT THE SPREAD OF DUST TO THE BUILDING G PRIOR TO COMMENCING WITH THE DEMOLITION THE CONTRACTOR SHALL ASCERTAIN FROM THE OWNER WHETHER OR NOT THE OWNER WISHES TO RETAIN ANY ITEMS. ANY SUCH ITEMS SHALL BE REMOVED WITH CARE SO AS TO PREVENT UNNECESSARY DAMAGE. H CONTRACTOR SHALL MAKE FUNCTIONAL ALL CIRCUITS DISRUPTED BY ANY DEMOLITION IN THIS AREA. I HAZARDOUS MATERIALS ARE REQUIRED TO BE REMOVED DUE TO THE SCOPE OF WORK. THE REMOVAL WILL BE PROVIDED BY THE OWNER PRIOR TO PROJECT COMMENCEMENT. GENERAL FLOOR PLAN NOTES A GENERAL CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS AND REPORT DISCREPANCIES IMMEDIATELY TO THE ARCHITECT. B DIMENSIONS ARE TO CENTERLINE OF COLUMN LINES, FACE OF INTERIOR STUDS, FACE OF EXTERIOR WALL SHEATHING AND FACE OF MASONRY UNLESS NOTED OTHERWISE. C DOORS AND WINDOWS ARE DIMENSIONED TO THE CENTER OF THE OPENING. D THE CONTRACTOR SHALL COORDINATE ALL UNDERGROUND PIPING, MECHANICAL AND ELECTRICAL WORK. E DOOR JAMBS ARE 6" OFF NEAREST PERPENDICULAR WALL UNLESS NOTED OTHERWISE. F PROVIDE 1'-0" MINIMUM CLEARANCE FOR HANDICAP ACCESS FROM EDGE OF ALL DOORS ON "PUSH" SIDE TO THE ADJACENT FINISHED WALL AND 1'-6" MINIMUM CLEARANCE ON THE "PULL" SIDE. G DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS FOR ALL MEASUREMENTS. H ROOMS ARE DEFINED BY WALLS, FACES OF DOORS AND ROOM CHANGE INDICATORS. I PROVIDE WOOD BLOCKING IN PARTITIONS AT ALL LOCATIONS WHERE WORK SURFACE, SHELVING, BRACKETS, DISPLAYS, GRAB BARS, HANDRAILS AND/OR EQUIPMENT WILL BE MOUNTED OR ATTACHED TO THE FACE OF WALL FOR STRUCTURAL STABILITY. REFERENCE FLOOR PLAN FOR LOCATIONS OF SUCH EQUIPMENT. ALL CONCEALED WOOD SHALL BE FIRE-RETARDANT LUMBER. J LUMBER AND BLOCKING IN CONTACT WITH MASONRY AND CONCRETE SHALL BE PRESSURE TREATED. K USE WATER RESISTANT (TYPE "X" AS REQUIRED) GWB BEHIND ALL SINKS AND WET AREAS. L NON-FIXED FURNITURE AND EQUIPMENT IS SHOWN FOR INFORMATION ONLY. NO NON-FIXED FURNITURE, FURNISHINGS OR EQUIPMENT ARE A PART OF THE CONSTRUCTION CONTRACT UNLESS NOTED OTHERWISE. M USE TWO-STUD CORNERS WHERE POSSIBLE GENERAL CASEWORK NOTES A THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE DOCUMENTS AND THE CASEWORK ELEVATIONS IN THIS SET AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY ERROR, INCONSISTENCY OR OMISSION THAT IS DISCOVERED. B THE CONTRACTOR SHALL VERIFY AND COORDINATE CLEAR DIMENSIONS REQUIRED FOR EQUIPMENT WHICH IS LOCATED WITHIN OR ADJACENT TO ANY PIECE OF CASEWORK (REFER TO FLOOR PLANS FOR EQUIPMENT LOCATIONS). C CASEWORK DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO UNIT FABRICATION AND INSTALLATION. D COUNTERTOPS, UNLESS OTHERWISE NOTED, SHALL HAVE A 4" HIGH BACKSPLASH AND SIDE SPLASH SCRIBED TO CONFORM TO THE SURFACE OF ABUTTING WALLS AT BACKS AND ENDS. COUNTERTOPS AND BACKSPLASHES SHALL BE CAULKED TO THE WALL. E CASEWORK MANUFACTURER AND INSTALLER SHALL COORDINATE WITH APPROPRIATE SUBCONTRACTORS FOR INSTALLATION OF SINKS WITH ASSOCIATED PIPING AND FITTINGS, AND FOR INSTALLATION OF ELECTRICAL RECEPTACLES, LIGHT FIXTURES, ETC. WITHIN THE CASEWORK. F PROVIDE SCHEDULED BASE ALONG BOTTOM OF EXPOSED FRONTS, BACKS, SIDES, AND ENDS OF ALL AFFIXED CASEWORK, VERTICAL SUPPORTS, KNEE SPACES, ETC. (U.N.O.) G PROVIDE HIDDEN BLOCKING FOR MOUNTING OF ALL SHELVING, HOOKS, DISPENSERS, ETC. H ALL CASEWORK TO BE PAINTED SHALL BE SANDED SMOOTH, CLEANED FREE OF DUST AND DEFECTS CORRECTED PRIOR TO PAINTING. WOOD SHALL BE PRIMED AS RECOMMENDED BY THE MANUFACTURER AND PAINTED WITH TWO COATS OF PAINT OF THE TYPE, COLOR AND FINISH SPECIFIED HEREIN. GENERAL FINISH NOTES A ALL INTERIOR FINISH SPECIFICATIONS AS REQUIRED OF THE ARCHITECT ARE INCLUDED HEREIN. SHOULD THERE BE DISCREPANCIES OR OMISSIONS, THE ARCHITECT IS TO BE CONSULTED BEFORE PROCEEDING. THE ARCHITECT IS NOT RESPONSIBLE FOR DISCREPANCIES OR OMISSIONS THAT ARISE DUE TO CHANGES BY THE CONTRACTORS, CONSULTANTS OR OWNERS AFTER DATE OF DRAWINGS UNLESS NOTED AS A REVISION ON DRAWINGS. B IF THERE SHOULD BE ANY DISCREPANCIES, DISCONTINUED OR DELAYED MATERIALS, THE OWNER IS TO BE NOTIFIED IMMEDIATELY AND CONSULTED BEFORE PROCEEDING. UNDER NO CIRCUMSTANCES ARE SUBSTITUTIONS TO BE MADE WITHOUT APPROVAL OF ALL INVOLVED PARTIES. C ALL INTERIOR FINISHES TO BE CLASS "C" OR BETTER AS INDICATED. PROVIDE TEST DATA TO VERIFY FLAME SPREAD RATE. D ALL FINISHES AND MATERIALS SHALL BE AS INDICATED IN THE FINISH LEGEND. NO SUBSTITUTIONS WILL BE ACCEPTED WITHOUT PRIOR APPROVAL OF THE OWNER, TENANT, OR ARCHITECT. ANY SUBSTITUTIONS MUST BE DOCUMENTED IN WRITTEN FORM AND SIGNED BEFORE CONTRACTOR PROCEEDS WITH SUBSTITUTIONS. E ALL SURFACES WHICH ARE TO RECEIVE A FINISH APPLICATION SHALL BE COMPLETELY SMOOTH. IF SURFACES ARE NOT ACCEPTABLE TO RECEIVE FINISHES, CONTRACTOR TO HAVE SURFACES CORRECTED BEFORE BEGINNING FINISH APPLICATION. F PAINTING CONTRACTOR SHALL PAINT OUT 4'X4' AREAS IN SPECIFIED SPACES WITH ADEQUATE LIGHTING, FOR EACH COLOR SPECIFIED FOR APPROVAL BY THE ARCHITECT PRIOR TO BEGINNING WORK. SAMPLE AREAS SHALL HAVE THE SAME FINISH AND NUMBER OF COATS AS REQUIRED FOR THE ACTUAL WORK. G ALL MISCELLANEOUS GRILLES, PLATES, ETC. OCCURRING ON WALLS OR CEILINGS ARE TO BE FINISHED TO MATCH WALL OR CEILING ON WHICH THEY OCCUR. H CARPET OR OTHER FLOOR COVERING TRANSITIONS TO OCCUR UNDER CENTER LINE OF DOOR IN CLOSED POSITION. I INSTALL ALL FLOORING IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. J EXPOSED CONCRETE FLOORS SHALL BE SEALED (U.N.O.) K TRANSITION STRIP BETWEEN CERAMIC TILE AND CARPET SHALL BE AS MANUFACTURED BY SCHLUTER (3/8" HIGH) OR EQUAL. FINISH TO BE AS SPECIFIED IN THE FINISH SCHEDULE. L DOOR FRAMES SHALL BE PAINTED WITH SEMIGLOSS ENAMEL. M PRIME ALL SURFACES PRIOR TO APPLYING FINAL PAINT FINISHES. N ALL SURFACES SHALL RECEIVE A FINISH WHETHER NOTED OR NOT. ITEMS NOT NOTED WILL BE SELECTED BY THE ARCHITECT DURING CONSTRUCTION. O PROVIDE TRANSITION STRIP OF APPROPRIATE DESIGN AT ALL CONDITIONS. P PAINT ALL VENTS, GRILLES, PIPING, ETC. TO MATCH ADJACENT PAINT COLOR. Q PROVIDE SAMPLES AS PER SPECS. FOR APPROVAL PRIOR TO INSTALLING ALL FINISHES. R ALL COVER PLATES (COMPUTER, LIGHTS, TELEPHONE, ETC. TO BE STAINLESS STEEL. ALL DEVICES TO BE GREY. S PROTECT EXPOSED CONCRETE SLABS FROM MUD AND OIL STAINS. ALL MUD STAINS MUST BE COMPLETELY REMOVED FROM CONCRETE. NATIONAL ELECTRICAL CODE (NEC) NFPA 70: 2011 EDITION KEY PLAN AREA OF CONSTRUCTION: GROUND FLOOR HENDRIX STUDENT CENTER FOOD COURT FOR CONSTRUCTION