Page 1: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Hele-Shaw Experimental Group

Lucas LambAndrea Roeser

Chen Shu

Page 2: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Set Up

Page 3: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Pour Glycerol or PEO

Procedure:

Page 4: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Clamp the plastic plates

Page 5: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Note the wax paper background and ruler

Page 6: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Insert needle

Page 7: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Place mass onto syringe

Page 8: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Record the whole process

Page 9: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Our Set Up

Page 10: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Parameters Varied

Volume of injected water remains constant (1.2 mL)

Mass: 500 -> 1000 -> 1500 -> 2000 gCell spacing: 0.32 -> 0.52 -> 0.83 mm

Newtonian -> Non-Newtonian, then process repeated

Page 11: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

datetrial

numbernumber

of spacers

width of spacers (mm) Mass (g)

volume inside syringe

(mL) time (s)Flow Rate (mL/min)

3/25/2015 1 3 0.32 500 1.2 4.6 * 15.7 *3/25/2015 2 3 0.32 1000 1.2 3.2 * 22.5 *3/25/2015 3 3 0.32 1500 1.2 3.2 * 22.5 *3/25/2015 4 3 0.32 2000 1.2 2.1 * 34.3 *3/30/2015 1 3 0.32 2000 1.2 1.9 * 37.9 *3/30/2015 2 3 0.32 2000 1.2 2.2 * 32.7 *3/30/2015 3 5 0.52 500 1.2 5.1 * 14.1 *3/30/2015 4 5 0.52 1000 1.2 3 * 24 *3/30/2015 5 5 0.52 1500 1.2 2.2 * 32.7 *3/30/2015 6 5 0.52 200 1.2 8 * 9 *4/1/2015 1 5 0.52 1500 1.2 2 * 36 *4/1/2015 2 5 0.52 2000 1.2 1.8 * 40 *4/1/2015 3 5 0.52 200 1.2 13.3 * 5.4 *

5/4/2015 1 8 0.83 500 1.2 5 14.4

5/4/2015 2 8 0.83 1000 1.2 2.4 30

5/4/2015 3 8 0.83 1500 1.2 1.7 42.4

Newtonian Trials

Page 12: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

datetrial

numbernumber

of spacers

width of spacers (mm) Mass (g)

volume inside syringe

(mL) time (s) *Flow Rate *

(mL/min)4/1/2015 5 3 0.32 1000 1.2 2.4 304/6/2015 1 3 0.32 500 1.2 2.9 24.84/6/2015 2 3 0.32 250 1.2 6 124/6/2015 3 3 0.32 750 1.2 2.5 28.84/6/2015 4 3 0.32 125 1.2 14.8 4.94/6/2015 5 3 0.32 250 1.2 6.3 11.44/6/2015 6 5 0.52 500 1.2 3.5 20.6

4/13/2015 1 5 0.52 250 1.2 24.8 2.94/13/2015 2 5 0.52 125 1.2 18.4 3.94/13/2015 3 5 0.52 750 1.2 3.1 23.24/13/2015 4 5 0.52 250 1.2 7.4 9.74/13/2015 5 8 0.83 125 1.2 20.2 3.64/20/2015 1 8 0.83 250 1.2 10 7.24/20/2015 2 8 0.83 500 1.2 4.8 154/20/2015 3 8 0.83 750 1.2 2.8 25.7

Non-Newtonian Trials

Page 13: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Experimental [Trial and] Error• Placing mass on syringe – slides off

• Air bubbles – in syringe or in cell

• Glycerol or PEO clog needle

• Possible tilt to cell – water leaks to one side

• Clamping of syringe – unnecessary forces

• Flow rates! iPhone’s slow motion affected video timing

Page 14: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Analysis- Varied Mass

Newtonian Fluid (glycerol)Cell Spacing 0.52mm

Mass (L to R): 200g, 500g, 1000g, 1500g

Page 15: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Analysis- Varied Spacing

Newtonian Fluid (glycerol)Mass: 500 g

Cell Spacing (L to R): 0.32mm, 0.52mm, 0.83mm

Page 16: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Analysis- Varied Spacing

Newtonian Fluid (glycerol)Mass: 1000 g

Cell Spacing (L to R): 0.32mm, 0.52mm, 0.83mm

Page 17: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Analysis- Varied Mass

Non-Newtonian Fluid (PEO)Cell Spacing: 0.52mm

Mass (L to R): 125g, 250g, 500g, 750g

Page 18: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

Analysis- Varied Spacing

Non-Newtonian Fluid (PEO)Mass: 500 g

Cell Spacing: 0.32mm (left), 0.52mm (middle), 0.83mm (right)

Page 19: Hele-Shaw Experimental Group Lucas Lamb Andrea Roeser Chen Shu.

THE END

Thank you Michael Lam