Top Banner
HEI Engineering Group completed an emergency domestic water heater replacement for the Green YMCA in Green, Ohio. The YMCA had a storage tank fail and their locker room showers were left without hot water. HEI Engineering Group was able to design a system and create bid documents within two days to expedite bids. The existing system consisted of two 350,000 btu boilers and a 460 gallon storage tank. HEI designed a system using two A.O. Smith Cyclone 300,000 btu high efficient water heaters and a 175 gallon storage tank. The system was designed with bypass valves in case any of the components would require maintenance or in case of failure, the YMCA could still have domestic hot water. The installing contractor worked evenings and Easter weekend to complete the project as quickly as possible. Within two weeks from start of design, the system was installed and operating. Green YMCA – Water Heater Replacement One of the Old Boilers New Storage Tank New Water Heaters
1

HEI Project - Green YMCA Water Heater Project - Green YMCA Water Heater.pdf · +(, (qjlqhhulqj *urxs frpsohwhg dq hphujhqf\ grphvwlf zdwhu khdwhu uhsodfhphqw iru wkh *uhhq

Mar 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: HEI Project - Green YMCA Water Heater Project - Green YMCA Water Heater.pdf · +(, (qjlqhhulqj *urxs frpsohwhg dq hphujhqf\ grphvwlf zdwhu khdwhu uhsodfhphqw iru wkh *uhhq

HEI Engineering Group completed an emergency domestic water heater replacement for the Green YMCA in Green, Ohio. The YMCA had a storage tank fail and their locker room showers were left without hot water. HEI Engineering Group was able to design a system and create bid documents within two days to expedite bids. The existing system consisted of two 350,000 btu boilers and a 460 gallon storage tank. HEI designed a system using two A.O. Smith Cyclone 300,000 btu high efficient water heaters and a 175 gallon storage tank. The system was designed with bypass valves in case any of the components would require maintenance or in case of failure, the YMCA could still have domestic hot water. The installing contractor worked evenings and Easter weekend to complete the project as quickly as possible. Within two weeks from start of design, the system was installed and operating.

Green YMCA – Water Heater Replacement

One of the Old Boilers New Storage Tank

New Water Heaters