Top Banner
2015 Heating Pricelist Version 1
48

Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

Jun 04, 2018

Download

Documents

lykhuong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

2015HeatingPricelist

Version 1

Page 2: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

2

> Daikin Altherma low temperature split

System Introduction 4

Technical Specifications 6

Pricelist 8

> Daikin Altherma low temperature monobloc

System Introduction 10

Technical Specifications 12

Pricelist 14

> Daikin Altherma high temperature

System Introduction 16

Technical Specifications 18

Pricelist 20

> Daikin Altherma hybrid heat pump

System Introduction 22

Technical Specifications 24

Pricelist 25

Flue Gas System 26

> Daikin Altherma ground source heat pump

System Introduction 28

Technical Specifications 30

Pricelist 31

> Daikin Altherma Flex Type

System Introduction 32

Technical Specifications 34

Pricelist 36

> Daikin heat pump convector

System Introduction 38

Technical Specifications 39

Pricelist 39

> Daikin solar system

System Introduction 40

Technical Specifications 42

Pricelist 43

> Table of contents

▪ NOTESThe pricelist is valid from 15. April 2015. All prior pricelists are not valid anymore. All prices are list prices in Euro and excl. VAT. The Daikin Commercial Terms

and Conditions apply (see last page or http://www.daikin-ce.com). We reserve the right for printing errors and model changes.

NEW!

Page 3: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

3

You and your customer have decided to switch to an energy-effi cient heating

system that produces low CO2 emissions. Daikin Altherma is a total heating

and domestic hot water system based on air source heat pump technology.

One that represents a fl exible and cost-eff ective alternative to a fossil fuel boiler.

It also has an option for cooling.*

The inherent energy-effi ciency characteristics of Daikin Altherma make it

an ideal solution for reduced energy consumption and low CO2

emissions. Its high- and low-temperature heating systems provide optimal

comfort. Highly energy-effi cient heat pumps with advanced compressor

technology transform unused and inexhaustible heat from the surrounding air

into usable heat, either as part of the overall climate-control system or to

heat domestic hot water. Moreover, the system is easy to install.

*The Daikin Altherma cooling option is available for low-temperature heating systems (under fl oor heating system, heat pump convectors).

Page 4: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

4

High heat pump effi ciencies at all outdoor and water

temperatures guarantee low running costs and low CO2

emissions.

High heating capacities enable best effi ciencies down to low

outside temperature. The electrical back-up heater assistance is

no longer required or only very limited.

Daikin inverter compressors with high modulation range

provide:

– Higher compressor effi ciency in partial load operation.

– Delivered capacities exactly matching the actual heating

demand of the building.

– Obtaining the capacities needed with minimum energy

consumption.

– Less on/off operation, increasing the operation life cycle

of the compressor.

Limiting electrical inputs of auxiliary components

contribute to the high seasonal effi ciencies:

– Factory-mounted high effi ciency circulating pump

already qualifying for future regulations (ErP2015) with

an A-energy label (EEI ≤ 0.23)

– No standby losses of inverter drive PCB, lowering

electricity consumption during standby mode

– No bottom plate heater needed on 4-8kW class

– Low-capacity bottom plate heater on 11-16kW class

(ERLQ-C series), only operating during defrost cycles.

NEW: Optimised unit for low heat loads available

The new-build house market in Europe is moving towards

smaller heat loads, due to:

– Growing importance of low-energy houses

– Strengthened legislation on energy consumption in

new residential constructions (e.g. EPBD regulations)

– Decreasing size of new-build houses

– EU member states planning to reach their

20-20-20 targets

The new Daikin Altherma low temperature is designed to

meet the requirements of newly built and low-energy houses

characterised by low heat loads.

With capacities from 4 to 16kW Daikin Altherma covers 90%

of all new built applications.

All types of heat emitters are possible:

– Under-fl oor heating: 25°C à 35°C

– Heat pump convector: 35°C à 45°C

– Low temperature radiators: 40°C à 50°C

Daikin Altherma is suitable for all climates, even

withstanding severe winter conditions.

Best seasonal effi ciencies,providing the highest savings on

running costs and CO2 emissions.

Perfect fi t

for new builds,

as well as for low-energy houses

> Daikin Altherma low temperature split

COP up to 4,02

A2/W35 (according to

EN14511)

Page 5: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

5

Easiest and fastest installation, domestic hot water tank included

– Fast installation: the stainless steel domestic hot water

tank is included in the unit, with all connections between

heat pump module and tank factory made.

– All hydraulic components are included.

– Lower installation footprint.

Minimised installation space, both in terms of footprint

and height:

– Small footprint with a width

of only 60cm and a depth of 74cm

– The required installation height is

less than 2m

– Sleek design and modern look

Best solution for domestic hot water

heating with high effi ciency and high comfort

– 50% less heat loss compared to a standard insulated tank.

– High hot water volumes: 300l at 40°C, enough for

6 showers without any electrical assistance.

Wall-mounted indoor unit including all hydraulic components.

Quick and easy commissioning:

– Quick confi guration wizard to guide installer through

commissioning process

– Menu-based navigation to fi ne-tune the basic parameters

– Parameters are up- and downloadable from/to PC

– Actuator test mode to activate all wired components

one by one

– Automatic screed-drying function

Room temperature control functionality:

The user interface itself is equipped with a temperature sensor

and can be directly used as a rom thermostat, resulting in more

stable room temperatures, increased effi ciency and operation

life cycle.

User-friendly with intuitive control:

– The large graphical interface allows an intuitive and

self-explanatory menu

– Provides additional information such as the energy

consumption and heat production of the system

74

cm

60 cm

Graphical screen with backlight

On/Off

Menu back

Navigational buttonsConfi rm

Home

Error info

Integratedindoor unit: best solution for domestic

hot water for installer & customer

User interface:

high functionalities, easy to use

> Daikin Altherma low temperature split

Page 6: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

6

HEATING & COOLING

INDOOR UNIT - WALL MOUNTEDEHBX04CB3V

EHBX08CB3VEHBX08CB9W

Dimensions Unit H x W x D mm 890x480x344 890x480x344

Operation range Heating Water side Min.~Max. °C 15~55 15~55

Cooling Water side Min.~Max. °C 5~22 5~22

Domestic hot water Water side Min.~Max. °C 25~80 25~80

Sound pressure level* Nom. dBA 26 26

Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V

HEATING ONLY

INDOOR UNIT - FLOORSTANDINGEHVH04S18CB3V

EHVH08S18CB3VEHVH08S26CB9W

Dimensions Unit H x W x D mm 1.732x600x728 1.732x600x728

Operation range Heating Water side Min.~Max. °C 15~55 15~55

Domestic hot water Water side Min.~Max. °C 25~60 25~60

Sound pressure level* Nom. dBA 28 28

Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V

HEATING & COOLING

INDOOR UNIT - FLOORSTANDINGEHVX04S18CB3V

EHVX08S18CB3VEHVX08S26CB9W

Dimensions Unit H x W x D mm 1.732x600x728 1.732x600x728

Operation range Heating Water side Min.~Max. °C 15~55 15~55

Cooling Water side Min.~Max. °C 5~22 5~22

Domestic hot water Water side Min.~Max. °C 25~60 25~60

Sound pressure level* Nom. dBA 28 28

Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V

OUTDOOR UNIT ERLQ004CV3 ERLQ006CV3 ERLQ008CV3

Heating capacity Min. kW 1,80 1 1,801 1,801

Nom. kW 4,401 / 3,272 6,001 / 4,582 7,401 / 5,802

Max. kW 5,121 8,351 10,021

Cooling capacity Nom. kW 5,003 / 4,174 6,763 / 4,844 6,863 / 5,364

COP nom. 5,041 / 4,022 4,741 / 3,682 4,451 / 3,532

EER nom. 3,373 / 2,324 3,453 / 2,344 3,423 / 2,294

Dimensions Unit H x W x D mm 735x832x307 735x832x307 735x832x307

Operation range Heating Min.~Max. °C -25~25 -25~25 -25~25

Cooling Min.~Max. °C 10~43 10~43 10~43

Domestic hot water Min.~Max. °C -25~35 -25~35 -25~35

Sound pressure

level*

Heating Nom. dBA 48 48 49

Cooling Nom. dBA 48 49 50

Power supply (phase/voltage) 1~/230V 1~/230V 1~/230V

▪ Technical specifi cations

> Daikin Altherma low temperature split

INDOOR UNIT - WALL MOUNTEDEHBH04CB3V

EHBH08CB3VEHBH08CB9W

Dimensions Unit H x W x D mm 890x480x344 890x480x344

Operation range Heating Water side Min.~Max. °C 15~55 15~55

Domestic hot water Water side Min.~Max. °C 25~80 25~80

Sound pressure level* Nom. dBA 26 26

Power supply (phase/voltage) 1~/230V 1~/230V / 3~/400V

HEATING ONLY

Page 7: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

7

*Measured in 1m distance from the unit.

(1) EW 30°C; LW 35°C; ambient conditions: 7°CDB/6°CWB

(2) EW 30°C; LW 35°C; ambient conditions: 2°CDB/1°CWB

(3) EW 23°C; LW18°C; ambient conditions: 35°C

(4) EW 12°C; LW 7°C; ambient conditions 35°C

EHBX11CB3V

EHBX11CB9W*

EHBX16CB3V

EHBX16CB9W*

890x480x344 890x480x344

15~55 15~55

5~22 5~22

25~80 25~80

33 33

1~/230V / *3~/400V 1~/230V / *3~/400V

EHVH11S18CB3V

EHVH11S26CB9W*

EHVH16S18CB3V

EHVH16S26CB9W*

1.732x600x728 1.732x600x728

15~55 15~55

25~60 25~60

33 33

1~/230V / *3~/400V 1~/230V / *3~/400V

EHVX11S18CB3V

EHVX11S26CB9W*

EHVX16S18CB3V

EHVX16S26CB9W*

1.732x600x728 1.732x600x728

15~55 15~55

5~22 5~22

25~60 25~60

33 33

1~/230V / *3~/400V 1~/230V / *3~/400V

ERLQ11CV3 / ERLQ11CW1 ERLQ14CV3 / ERLQ14CW1 ERLQ16CV3 / ERLQ16CW1

– – –

11,201 / 8,562 14,501 / 10,302 16,001 / 11,102

11,381 14,551 16,101

15,053 / 11,724 16,063 / 12,554 16,763 / 13,124

4,601 / 3,602 4,301 / 3,452 4,251 / 3,352

3,323 / 2,724 2,963 / 2,474 2,723 / 2,294

1.345x900x320 1.345x900x320 1.345x900x320

-25~35 -25~35 -25~35

10~46 10~46 10~46

-20~35 -20~35 -20~35

51 51 52

50 52 54

1~/230V / 3~/400V 1~/230V / 3~/400V 1~/230V / 3~/400V

> Daikin Altherma low temperature split

EHBH11CB3V

EHBH11CB9W*

EHBH16CB3V

EHBH16CB9W*

890x480x344 890x480x344

25~55 25~55

25~80 25~80

33 33

1~/230V / *3~/400V 1~/230V / *3~/400V

Page 8: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

8

Daikin Altherma Low Temperature Outdoor Unit

Inverter Split Heat pump outdoor unit with nominal capacities from 4 to 8 kW. Nominal capacity is measured at A7/W35**. PRICE CZK

Daikin Altherma 4 kW outdoor unit* ERLQ004CV3 Power Supply 1~ 230V 44.921,-

Daikin Altherma 6 kW outdoor unit ERLQ006CV3 Power Supply 1~ 230V 49.439,-

Daikin Altherma 8 kW outdoor unit ERLQ008CV3 Power Supply 1~ 230V 67.465,-

Daikin Altherma wallmounted indoor unit for heating only applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included.PRICE CZK

Wallmounted indoor unit 4kW with 3kW BUH* EHBH04CB3V Electrical Backup Heater 1~ 230V 69.562,-

Wallmounted indoor unit 6-8 kW with 3kW BUH EHBH08CB3V Electrical Backup Heater 1~ 230V 76.847,-

Wallmounted indoor unit 6-8kW with 3-9 kW BUH EHBH08CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 80.749,-

Daikin Altherma wallmounted indoor unit for heating & cooling applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK

Wallmounted indoor unit 4kW with 3kW BUH* EHBX04CB3V Electrical Backup Heater 1~ 230V 75.915,-

Wallmounted indoor unit 6-8 kW with 3kW BUH EHBX08CB3V Electrical Backup Heater 1~ 230V 79.908,-

Wallmounted indoor unit 6-8kW with 3-9 kW BUH EHBX08CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 83.629,-

Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating only applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK

Floorstanding indoor unit 4kW with 3kW BUH & 180L Tank* EHVH04S18CB3V Electrical Backup Heater 1~ 230V 101.236,-

Floorstanding indoor unit 6-8 kW with 3kW BUH & 180L Tank EHVH08S18CB3V Electrical Backup Heater 1~ 230V 108.550,-

Floorstanding indoor unit 6-8kW with 3-9 kW BUH & 260L Tank EHVH08S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 116.561,-

Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating & cooling applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK

Floorstanding indoor unit 4kW with 3kW BUH & 180L Tank* EHVX04S18CB3V Electrical Backup Heater 1~ 230V 107.584,-

Floorstanding indoor unit 6-8 kW with 3kW BUH & 180L Tank EHVX08S18CB3V Electrical Backup Heater 1~ 230V 111.588,-

Floorstanding indoor unit 6-8kW with 3-9 kW BUH & 260L Tank EHVX08S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 119.450,-

Daikin Altherma Low Temperature Outdoor Unit

Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35**PRICE CZK

Daikin Altherma 11 kW outdoor unit ERLQ011CV3 Power Supply 1~ 230V 70.005,-

Daikin Altherma 14 kW outdoor unit ERLQ014CV3 Power Supply 1~ 230V 83.397,-

Daikin Altherma 16 kW outdoor unit ERLQ016CV3 Power Supply 1~ 230V 94.700,-

Daikin Altherma Low Temperature Outdoor Unit

Inverter Split Heat pump outdoor unit with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35**. PRICE CZK

Daikin Altherma 11 kW outdoor unit ERLQ011CW1 Power Supply 3~ 400V 78.197,-

Daikin Altherma 14 kW outdoor unit ERLQ014CW1 Power Supply 3~ 400V 91.956,-

Daikin Altherma 16 kW outdoor unit ERLQ016CW1 Power Supply 3~ 400V 113.863,-

Daikin Altherma wallmounted indoor unit for heating only applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included.PRICE CZK

Wallmounted indoor unit 11kW with 3KW BUH EHBH11CB3V Electrical Backup Heater 1~ 230V 81.600,-

Wallmounted indoor unit 11 kW with 3-9 kW BUH EHBH11CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 86.700,-

Wallmounted indoor unit 16 kW with 3 kW BUH EHBH16CB3V Electrical Backup Heater 1~ 230V 88.603,-

Wallmounted indoor unit 16 kW with 3-9 kW BUH EHBH16CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 93.058,-

Daikin Altherma wallmounted indoor unit for heating & cooling applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included.PRICE CZK

Wallmounted indoor unit 11kW with 3KW BUH EHBX11CB3V Electrical Backup Heater 1~ 230V 85.300,-

Wallmounted indoor unit 11 kW with 3-9 kW BUH EHBX11CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 89.275,-

Wallmounted indoor unit 16 kW with 3 kW BUH EHBX16CB3V Electrical Backup Heater 1~ 230V 91.949,-

Wallmounted indoor unit 16 kW with 3-9 kW BUH EHBX16CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 96.275,-

Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating only applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK

Floorstanding indoor unit 11 kW with 3kW BUH & 180 L Tank EHVH11S18CB3V Electrical Backup Heater 1~ 230V 116.800,-

Floorstanding indoor unit 11 kW with 3-9 kW BUH & 260 L Tank EHVH11S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 124.200,-

Floorstanding indoor unit 16 kW with 3kW BUH & 180L Tank EHVH16S18CB3V Electrical Backup Heater 1~ 230V 118.168,-

Floorstanding indoor unit 16 kW with 3-9 kW BUH & 260 L Tank EHVH16S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 126.459,-

▪ Pricelist

Daikin Altherma is a low temperature, inverter driven air to water split heat pump system. The outdoor unit is connected to the indoor unit (wallmounted or fl oorstanding) with refrigerant piping. The heat pump system can be used for space heating, space cooling and domestic hot water production.

> Daikin Altherma low temperature split

Page 9: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

9

INDOOR UNIT

Wallmounted Floorstanding Wallmounted FloorstandingEHBH04CB3V

EHBX04CB3V

EHBH08CB3V

EHBX08CB3V

EHBH08CB9W

EHBX08CB9W

EHVH04S18CB3V

EHVX04S18CB3V

EHVH08S18CB3V

EHVX08S18CB3V

EHVH08S26CB9W

EHVX08S26CB9W

EHBH11CB*

EHBX11CB*

EHBH16CB*

EHBX16CB*

EHVH11S18CB*

EHVX11S18CB*

EHVH16S26CB*

EHVX16S26CB*

OU

TD

OO

R U

NIT

ERLQ004CV3 ● – – ● – – – – – –ERLQ006CV3 – ● ● – ● ● – – – –ERLQ008CV3 – ● ● – ● ● – – – –ERLQ011CV3 – – – – – – ● – ● –ERLQ014CV3 – – – – – – – ● – ●ERLQ016CV3 – – – – – – – ● – ●ERLQ011CW1 – – – – – – ● – ● –ERLQ014CW1 – – – – – – – ● – ●ERLQ016CW1 – – – – – – – ● – ●

*3V versions and 9W versions (1~ 230V and 3~ 400V versions)

▪ Combinations

Controller and User Interface, mandatory for each *CB unit. (Other languages you will fi nd on page 25)Applicable for:

PRICE CZK4-8kW 11-16kW

Controller EKRUCBL1 User interface with languages FR, NL, DE, IT ● ● 3.296,-

Controller EKRUCBL5 User interface with languages DE, SI, CZ, SK ● ● 3.296,-

Options & AccessoriesApplicable for:

PRICE CZK4-8kW 11-16kW

Drainpan for outdoor unit

(exl. drainpan heater)

EKDP008C Collect water from defrost cycle and drain via central hole to remote location.

If installed additional heater tape EKDPH00bC is mandatory!● 4.997,-

Heater tape for outdoor unit drainpan EKDPH008C Heater tape to install in central hole of drain pan to prevent ice blockage ● 7.555,-

Remote temperature sensor for outdoor unit EKRSC1 Ambient temperature measurement remotely from outdoor unit ● 2.617,-

U-beams for outdoor unit EKFT008CA Beams to mount outdoor unit on (height 25cm) ● 3.112,-

Remote indoor sensor KRCS01-1 Temperature measurement remotely from user interface ● ● 2.432,-

PC cable EKPCCAB2 Cable to upload fi eld settings from PC to unit ● ● 7.555,-

Drain pan kit for indoor unit EKHBDPC2 Collect and drain condensate during cooling operation ● ● 4.527,-

Wired room thermostat EKRTWA Wired Digital Room Thermostat ● ● 3.938,-

Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● ● 6.713,-

Thermostat external sensor EKRTETS Temperature measurement remotely from wireless room thermostat (e.g. fl oor temperature) ● ● 516,-

Digital I/O PCB EKRP1HBA Remote alarm / operation status ● ● 4.144,-

Demand PCB EKRP1AHT Power consumption limitation with 4 digital inputs on hydrobox ● 4.158,-

Demand PCB KRP58M51 Power consumption limitation via outdoor unit ● 5.640,-

Solar Kit EKSOLHW Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank ● ● 23.134,-

Electricity meter K.ELECMETV Single phase electricity meter ● ● 4.962,-

Electricity meter K.ELECMETW Three phase electricity meter ● ● 10.353,-

Domestic hot water connection kit for EKHWP300B H/O EKDVCPLT3H/X Connection kit for LT 4-8kW in combination with EKHWP300B ● 7.140,-

Domestic hot water connection kit for EKHWP500B H/O EKDVCPLT5H Connection kit for LT 4-16kW heating only in combination with EKHWP500B ● ● 15.049,-

Domestic hot water connection kit for EKHWP500B H/C EKDVCPLT5X Connection kit for LT 4-16kW heating & cooling in combination with EKHWP500B ● ● 19.967,-

Electrical Booster Heater EKBH3S Electrical booster heat for EKHWP-B tanks ● ● 9.803,-

Domestic Hot Water Tank Sets

(consists of tank, booster heater, contactor/fuse assembly for BH, tanksensor + 12m connection wire, 3 Way Valve + motor)

Applicable for:PRICE CZK

4-8kW 11-16kW

Stainless Steel Domestic Hot Water Tank 150L EKHWS150B3V3 incl. 3kW booster heater 1~ 230V, height 900mm, diameter 580mm, weight 37kg ● ● 30.657,-

Wallbracket for 150L stainless steel tank EKWBSWW150 ● ● 8.701,-

Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3V3 incl. 3kW booster heater 1~ 230V, height 1150mm, diameter 580mm, weight 45kg ● ● 31.670,-

Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3Z2 incl. 3kW booster heater 2~ 400V, height 1150mm, diameter 580mm, weight 45kg ● ● 31.670,-

Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3V3 incl. 3kW booster heater 1~ 230V, height 1600mm, diameter 580mm, weight 59kg ● ● 35.814,-

Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3Z2 incl. 3kW booster heater 2~ 400V, height 1600mm, diameter 580mm, weight 59kg ● ● 35.814,-

Enameled Domestic Hot Water Tank 150L EKHWE150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 80kg ● ● 25.556,-

Enameled Domestic Hot Water Tank 150L (wallmounted) EKHWET150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 82kg ● ● 26.620,-

Enameled Domestic Hot Water Tank 200L EKHWE200A3V3 incl. 3kW booster heater 1~ 230V, height 1580mm, diameter 545mm, weight 104kg ● ● 26.412,-

Enameled Domestic Hot Water Tank 200L EKHWE200A3Z2 incl. 3kW booster heater 2~ 400V, height 1580mm, diameter 545mm, weight 104kg ● ● 26.412,-

Enameled Domestic Hot Water Tank 300L EKHWE300A3V3 incl. 3kW booster heater 1~ 230V, height 1572mm, diameter 660mm, weight 140kg ● ● 29.815,-

Enameled Domestic Hot Water Tank 300L EKHWE300A3Z2 incl. 3kW booster heater 2~ 400V, height 1572mm, diameter 660mm, weight 140kg ● ● 29.815,-

Domestic Hot Water Tanks with pressureless buff er tank and hygienic domestic hot water production

(can be used for solar option)

Applicable for:PRICE CZK

4-8kW 11-16kW

Pressureless 300L Domestic Hot Water Tank EKHWP300B Pressureless hygienic domestic hot water tank with solar option for 4-8 kW LT heat pumps ● 44.212,-

Pressureless 500L Domestic Hot Water Tank EKHWP500B Pressureless hygienic domestic hot water tank with solar option for 4-16kW LT heat pumps ● ● 50.615,-

> Daikin Altherma low temperature split

Daikin Altherma Indoor unit (fl oorstanding with domestic hot water tank) for heating & cooling applications.

Controller is not included, EKRUCBL is mandatory for system operation. All basic necessary hydraulic components included. PRICE CZK

Floorstanding indoor unit 11 kW with 3 kW BUH & 180 L Tank EHVX11S18CB3V Electrical Backup Heater 1~ 230V 123.581,-

Floorstanding indoor unit 11 kW with 3-9 kW BUH & 260 L Tank EHVX11S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 128.032,-

Floorstanding indoor unit 16 kW with 3kW BUH & 180L Tank EHVX16S18CB3V Electrical Backup Heater 1~ 230V 125.200,-

Floorstanding indoor unit 16 kW with 3-9 kW BUH & 260 L Tank EHVX16S26CB9W Electrical Backup Heater 1~ 230V or 3~ 400V 129.732,-

* The 4kW outdoor ERLQ004CV3 unit can only be combined with a 4kW indoor unit (either wallmounted or fl oorstanding)!

** Ta DB/WB 7°C / 6°C - LWC 35°C (DT = 5K)

Page 10: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

10

Page 11: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

11

Monobloc system

Outdoor unit:

11, 14 and 16 kW Under floor heating

Heat pump convectorDomestic hot water Solar connection (optional)

Everything combined in one outdoor unit

In addition to Daikin Altherma split systems, Daikin has introduced a monobloc

version in which all hydraulic parts are located within the outdoor unit.

In this system, the water pipes, rather than the refrigerant pipes, run indoors

from the outdoor unit, making installation much quicker and easier

for the domestic installer.

Available capacities for monobloc: 11, 14, 16 kW

> Daikin Altherma low temperature monobloc

Page 12: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

12

THREE

PHASE

SINGLE

PHASE

HEATING ONLY

EDLQ011BC6V3 EDLQ014BC6V3 EDLQ016BC6V3

Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692

Power input Heating Nom. kW 2,561 / 2,572 3,291 / 3,122 3,881 / 3,442

COP 4,381 / 3,162 4,251 / 3,122 4,121 / 3,112

Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382

Weight Unit kg 180

Hydraulic

component

Back-up

heater current

Type 6V3

Power

supply

Phase/Frequency/

Voltage

~/Hz/V1~/50/230

Operation range Heating Ambient Min.~Max. °C -20~35

Water side Min.~Max. °C 15 ~55

Domestic hot

water

Ambient Min.~Max. °C -20~43

Water side Min.~Max. °C 25~80

Refrigerant Type R-410A

Charge kg 2,95

Sound power level Heating Nom. dBA 64 65 66

Sound pressure level Heating Nom. dBA 51 52

Compressor

component

Main power

supply

Name V3

Phase 1~

Frequency Hz 50

Voltage V 230

(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)

(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)

HEATING ONLY

EDLQ011BC6W1 EDLQ014BC6W1 EDLQ016BC6W1

Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692

Power input Heating Nom. kW 2,601/ 2,612 3,301 / 3,132 3,811 / 3,442

COP 4,311 / 3,112 4,241 / 3,112 4,201 / 3,112

Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382

Weight Unit kg 180

Hydraulic

component

Back-up

heater current

Type 6W1

Power

supply

Phase/Frequency/

Voltage

~/Hz/V3~/50/400

Operation range Heating Ambient Min.~Max. °C -25~35

Water side Min.~Max. °C 15 ~55

Domestic hot

water

Ambient Min.~Max. °C -25~43

Water side Min.~Max. °C 25~80

Refrigerant Type R-410A

Charge kg 2,95

Sound power level Heating Nom. dBA 64 65 66

Sound pressure level Heating Nom. dBA 49 51 53

Compressor

component

Main power

supply

Name W1

Phase 3N~

Frequency Hz 50

Voltage V 400

(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)

(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)

> Daikin Altherma low temperature monobloc

▪ Technical specifi cations

Page 13: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

13

SINGLE

PHASE

THREE

PHASE

HEATING & COOLING

EBLQ011BC6V3 EBLQ014BC6V3 EBLQ016BC6V3

Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692

Cooling capacity Nom. kW 12,851 / 10,002 15,991 / 12,502 16,731 / 13,102

Power input Cooling Nom. kW 3,871 / 3,692 5,751 / 5,392 6,361 / 5,932

Heating Nom. kW 2,561 / 2,572 3,291 / 3,122 3,881 / 3,442

COP 4,381 / 3,162 4,251 / 3,122 4,121 / 3,112

EER 3,321 / 2,712 2,781 / 2,322 2,631 / 2,212

Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382

Weight Unit kg 180

Hydraulic

component

Back-up

heater current

Type 6V3

Power

supply

Phase/Frequency/

Voltage

~/Hz/V1~/50/230

Operation range Heating Ambient Min.~Max. °C -20~35

Water side Min.~Max. °C 15~55

Cooling Ambient Min.~Max. °C 10~46

Water side Min.~Max. °C 5~22

Domestic hot

water

Ambient Min.~Max. °C -20~43

Water side Min.~Max. °C 25~80

Refrigerant Type R-410A

Charge kg 2,95

Sound power level Heating Nom. dBA 64 65 66

Cooling Nom. dBA 65 66 69

Sound pressure

level

Heating Nom. dBA 5 52

Cooling Nom. dBA 50 52 54

Compressor

component

Main power

supply

Name V3

Phase 1~

Frequency Hz 50

Voltage V 230

(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)(nom. values according to EN14511)

(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)

HEATING & COOLING

EBLQ011BC6W1 EBLQ014BC6W1 EBLQ016BC6W1

Heating capacity Nom. kW 11,201 / 8,112 14,001 / 9,722 16,001 / 10,692

Cooling capacity Nom. kW 12,851 / 10,002 15,991 / 12,502 16,731 / 13,102

Power input Cooling Nom. kW 3,871 / 3,692 5,401/ 5,062 6,151 / 5,752

Heating Nom. kW 2,601/ 2,612 3,301 / 3,132 3,811 / 3,442

COP 4,311 / 3,112 4,241 / 3,112 4,201 / 3,112

EER 3,321 / 2,712 2,961 / 2,472 2,721 / 2,282

Dimensions Unit Height X Width X Depth mm 1.418 X 1.435 X 382

Weight Unit kg 180

Hydraulic

component

Back-up

heater current

Type 6W1

Power

supply

Phase/Frequency/

Voltage

~/Hz/V3~/50/400

Operation range Heating Ambient Min.~Max. °C -25~35

Water side Min.~Max. °C 15~55

Cooling Ambient Min.~Max. °C 10~46

Water side Min.~Max. °C 5~22

Domestic hot

water

Ambient Min.~Max. °C -25~43

Water side Min.~Max. °C 25~80

Refrigerant Type R-410A

Charge kg 2,95

Sound power level Heating Nom. dBA 64 65 66

Cooling Nom. dBA 65 66 69

Sound pressure

level

Heating Nom. dBA 49 51 53

Cooling Nom. dBA 50 52 54

Compressor

component

Main power

supply

Name W1

Phase 3N~

Frequency Hz 50

Voltage V 400

(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (nom. values according to EN14511)

(2) cooling Ta 35°C - LWE 7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (nom. values according to EN14511)

> Daikin Altherma low temperature monobloc

Page 14: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

14

▪ Pricelist

Daikin Altherma monobloc is designed as a compact unit, including

refrigeration cycle and all necessary parts of the water cycle in the units

casing.

Daikin Altherma monobloc simply has to be connected to water pipings,

without the need for refrigeration piping done by the installer.

Beside hydraulic parts such as water pump, expansion vessel, safety valve,

water fi lter and fl ow switch monobloc also includes a 6 kW factory mounted

backup heater, which can be reduced during commissioning to a minimum

of 2 kW (400V heater) or 3 kW (230V heater).

Daikin Altherma low temperature monobloc heating only

Inverter monobloc heat pump with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35. PRICE CZK

Daikin Altherma 11kW Monobloc 230V EDLQ011BC6V3 6kW BUH, Power Supply 1~ 230V 162.600,-

Daikin Altherma 14kW Monobloc 230V EDLQ014BC6V3 6kW BUH, Power Supply 1~ 230V 178.000,-

Daikin Altherma 14kW Monobloc 230V EDLQ016BC6V3 6kW BUH, Power Supply 1~ 230V 191.600,-

Daikin Altherma 11kW Monobloc 400V EDLQ011BC6W1 6kW BUH, Power Supply 3~ 400V 177.000,-

Daikin Altherma 14kW Monobloc 400V EDLQ014BC6W1 6kW BUH, Power Supply 3~ 400V 194.000,-

Daikin Altherma 14kW Monobloc 400V EDLQ016BC6W1 6kW BUH, Power Supply 3~ 400V 209.000,-

Daikin Altherma low temperature monobloc heating & cooling

Inverter monobloc heat pump with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W35. PRICE CZK

Daikin Altherma 11kW Monobloc 230V EBLQ011BC6V3 6kW BUH, Power Supply 1~ 230V 169.000,-

Daikin Altherma 14kW Monobloc 230V EBLQ014BC6V3 6kW BUH, Power Supply 1~ 230V 184.900,-

Daikin Altherma 14kW Monobloc 230V EBLQ016BC6V3 6kW BUH, Power Supply 1~ 230V 198.200,-

Daikin Altherma 11kW Monobloc 400V EBLQ011BC6W1 6kW BUH, Power Supply 3~ 400V 183.300,-

Daikin Altherma 14kW Monobloc 400V EBLQ014BC6W1 6kW BUH, Power Supply 3~ 400V 200.300,-

Daikin Altherma 14kW Monobloc 400V EBLQ016BC6W1 6kW BUH, Power Supply 3~ 400V 216.000,-

> Daikin Altherma low temperature monobloc

Page 15: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

15

Options & accessoriesApplicable for:

11-16kWPRICE CZK

Wired room thermostat EKRTWA Wired Digital Room Thermostat ● 3.938,-

Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● 6.713,-

Digital I/O PCB EKRP1HBA Remote alarm / operation status / … ● 4.144,-

Thermostat external sensor EKRTETS Temperature measurement remotely from wireless

room thermostat (e.g. fl oor temperature) ● 516,-

Solar Kit EKSOLHW Heat exchanger to connect Daikin solar system to EKHWS and EKHWE DHW tank ● 23.134,-

Domestic hot water connection kit for

EKHWP500B H/O

EKDVCPLT5H Connection kit for EDLQ heating only models

in combination with EKHWP500B ● 15.049,-

Domestic hot water connection kit for

EKHWP500B H/C

EKDVCPLT5X Connection kit for EBLQ heating & cooling models

in combination with EKHWP500B ● 19.967,-

Electrical Booster Heater EKBH3S Electrical booster heat for EKHWP-B tanks ● 9.803,-

Domestic hot water tanks (can be used for solar option)Applicable for:

11-16kWPRICE CZK

Stainless Steel Domestic Hot Water Tank 150L EKHWS150B3V3 incl. 3kW booster heater 1~ 230V, height 900mm, diameter 580mm, weight 37kg ● 30.657,-

Wallbracket for 150L stainless steel tank EKWBSWW150 ● 8.701,-

Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3V3 incl. 3kW booster heater 1~ 230V, height 1150mm, diameter 580mm, weight 45kg ● 31.670,-

Stainless Steel Domestic Hot Water Tank 200L EKHWS200B3Z2 incl. 3kW booster heater 2~ 400V, height 1150mm, diameter 580mm, weight 45kg ● 31.670,-

Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3V3 incl. 3kW booster heater 1~ 230V, height 1600mm, diameter 580mm, weight 59kg ● 35.814,-

Stainless Steel Domestic Hot Water Tank 300L EKHWS300B3Z2 incl. 3kW booster heater 2~ 400V, height 1600mm, diameter 580mm, weight 59kg ● 35.814,-

Enameled Domestic Hot Water Tank 150L EKHWE150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 80kg ● 25.556,-

Enameled Domestic Hot Water Tank 150L

(wallmounted)

EKHWET150A3V3 incl. 3kW booster heater 1~ 230V, height 1205mm, diameter 545mm, weight 82kg ● 26.620,-

Enameled Domestic Hot Water Tank 200L EKHWE200A3V3 incl. 3kW booster heater 1~ 230V, height 1580mm, diameter 545mm, weight 104kg ● 26.412,-

Enameled Domestic Hot Water Tank 200L EKHWE200A3Z2 incl. 3kW booster heater 2~ 400V, height 1580mm, diameter 545mm, weight 104kg ● 26.412,-

Enameled Domestic Hot Water Tank 300L EKHWE300A3V3 incl. 3kW booster heater 1~ 230V, height 1572mm, diameter 660mm, weight 140kg ● 29.815,-

Enameled Domestic Hot Water Tank 300L EKHWE300A3Z2 incl. 3kW booster heater 2~ 400V, height 1572mm, diameter 660mm, weight 140kg ● 29.815,-

Pressureless 500L Domestic Hot Water Tank EKHWP500B Pressureless hygienic domestic hot water tank with solar option ● 50.615,-

> Daikin Altherma low temperature monobloc

Page 16: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

16

Domestic hot

water tank

For replacement of traditional boilers

Indoor unit

Outdoor unit

Solar connection (optional)

Daikin Altherma high temperature system off ers heating and domestic hot

water for your home. This system can perfectly replace a traditional boiler and

connect to the existing piping. Daikin Altherma high temperature is therefore

the ideal solution for renovations. The split system consists of an outdoor unit and

an indoor unit and can be completed with solar connection.

> Daikin Altherma high temperature

Page 17: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

17

A split system consists of an outdoor unit and an indoor unit

The Daikin Altherma outdoor unit includes a heat pump that extracts heat from the outside air resulting in nearly 2/3 of all

usable heat coming from a sustainable and free source.

The outdoor unit extracts heat from the ambient outdoor air. This heat is transferred to the indoor unit via refrigerant piping.

The indoor unit receives the heat from the outdoor unit and further increases the temperature, allowing water temperatures

up to 80°C for heating through radiators and for domestic hot water use. Daikin’s unique cascade compressor approach

to the heat pumps (one in the outdoor unit/one in the indoor unit) means optimum comfort at even the coldest outdoor

temperatures, without the need for an electric back-up heater.

Daikin Altherma high temperature heats up to 3 times more effi ciently than a traditional heating system based on fossil

fuels or electricity. A lower running cost is thus achieved, while you can still enjoy a stable and pleasant level of comfort.*

* COP (Coeffi cient of Performance) of up to 3.08

Daikin Altherma’s high water temperature is ideal for heating domestic hot water without the need for an additional electric

heater. Rapid heating of domestic hot water also means smaller heaters are needed. For a family of approximately 4 people,

the standard tank is the best solution. Should you require more hot water, a larger tank is also available.

Heat emitters

The Daikin Atherma high temperature system is designed

to work with high-temperature radiators, which come in

various sizes and formats to suit the interior design as well as

the heating requirement. The radiators can be individually

controlled or they can be regulated by the central heating

control programme.

Solar connection

The Daikin Altherma high temperature heating system can

optionally use solar energy for hot water production.

If the solar energy is not required immediately, the purpose-

built hot water tank (EKHWP) can store large quantities of

heated water for up to a day for later use as domestic hot

water or for heating.

Domestic hot water tank

Split system

Page 18: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

18

▪ Technical specifi cations

OUTDOOR UNIT ERRQ011AV1 ERRQ014AV1 ERRQ016AV1 ERRQ011AY1 ERRQ014AY1 ERRQ016AY1

Heating capacity Nom. kW 11 1 / 11 2 14 1 / 14 2 16 1 / 16 2 11 1 / 11 2 14 1 / 14 2 16 1 / 16 2

Power input Heating Nom. kW 3,57 1 / 4,40 2 4,66 1 / 5,65 2 5,57 1 / 6,65 2 3,57 1 / 4,402 4,66 1 / 5,65 2 5,57 1 / 6,65 2

COP 3,08 1 / 2,50 2 3,00 1 / 2,48 2 2,88 1 / 2,41 2 3,08 1 / 2,50 2 3,00 1 / 2,48 2 2,88 1 / 2,41 2

Dimensions Unit H x W x D mm 1.345x900x320

Weight Unit kg 120

Operation

range

Heating Min.~Max. °CWB -20~20

Domestic hot water Min.~Max. °CDB -20~35

Refrigerant Type R-410A

Charge kg 4,5

Sound power level Heating Nom. dBA 68 69 71 68 69 71

Sound pressure level Heating Nom. dBA 52 53 55 52 53 55

Power supply Name/Phase/Frequency/Voltage Hz/V 1~/50/220-440 3~/50/380-415

Current Recommended fuses A 25 16

(1) EW 55ºC; LW 65ºC; Dt 10ºC; ambient conditions: 7ºCDB/6ºCWB

(2) EW 70ºC; LW 80ºC; Dt 10ºC; ambient conditions: 7ºCDB/6ºCWB

INDOOR UNIT - fl oor standing EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1

Casing Colour Metallic grey

Material Precoated sheet metal

Dimensions Unit H x W x D mm 705x600x695

Weight Unit kg 144,25 147,25

Operation

range

Heating Ambient Min.~Max. °C -20~20

Water side Min.~Max. °C 25~80

Domestic hot

water

Ambient Min.~Max. °CDB -20~35

Water side Min.~Max. °C 25~80

Refrigerant Type R-134a

Charge kg 3,2

Sound pressure

level

Nom. dBA 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46 43 / 46 45 / 46 46 / 46

Night quiet mode Level 1 dBA 40 43 45 40 43 45 40 43 45 40 43 45

Power supply Name V1 Y1

Phase 1~ 3~

Frequency Hz 50

Voltage V 220-240 380-415

Current Recommended fuses A 25 16

> Daikin Altherma high temperature

Page 19: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

19

Domestic hot water tank EKHTS200AC EKHTS260AC

Casing Colour Metallic grey

Material Galvanised steel (precoated sheet metal)

Dimensions Unit H x W x D mm 2.010x600x695 2.285x600x695

Weight Unit Empty kg 70 78

Tank Water volume l 200 260

Material Stainless steel (EN 1.4521)

Maximum water temperature °C 75

Insulation Heat loss kWh/24h 1,2 1,5

Heat exchanger Quantity 1

Tube material Duplex steel (EN 1.4162)

Face area m² 1,56

Internal coil volume l 7,5

Domestic hot water tank EKHWP300B EKHWP500B

Dimensions Unit Height mm 1.640 1.640

Width mm 595 790

Depth mm 615 790

Weight Unit Empty kg 59 93

Tank Water volume l 300 500

Maximum water temperature °C 85

Insulation Heat loss kWh/24h 1,3 1,4

Heat exchanger Domestic hot

water

Tube material Stainless steel

Face area m² 5,8 6

Internal coil volume l 27,9 29

Operating pressure bar 6

Average specifc thermal output W/K 2.790 2.900

Charging Tube material Stainless steel

Face area m² 2,7 3,8

Internal coil volume l 13,2 18,5

Operating pressure bar 3

Average specifc thermal output W/K 1.300 1.800

Auxiliary solar

heating

Tube material Stainless steel

Face area m² - 0,5

Internal coil volume l - 2,3

Operating pressure bar 3

Average specifc thermal output W/K - 280

Solar collector EKSH26P EKSV21P EKSV26P

Dimensions Unit H x W x D mm 1.300x2.000x85 2.000x1.006x85 2.000x1.300x85

Weight Unit kg 42 35 42

Volume l 2,1 1,3 1,7

Surface Outer m² 2,6 2,01 2,6

Aperture m² 2,350 1,79 2,35

Absorber m² 2,360 1,8 2,36

Coating Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)

Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate

Glazing Single pane safety glass, transmission +/- 92%

Allowed roof angle Min.~Max. ° 15~80

Operating pressure Max. bar 6

Stand still temperature Max. °C 200

Thermal performance Zero loss collector effi ciency η0 % -

Solar controller EKSRPS3

Mounting On side of tank

Dimensions Unit H x W x D mm 815x230x142

Thermal performance Zero loss collector effi ciency η0 % -

Control Type Digital temperature diff erence controller with plain text display

Power consumption W 2

Sensor Solar panel temperature sensor Pt1000

Storage tank sensor PTC

Return fl ow sensor PTC

Feed temperature and fl ow sensor Voltage signal (3,5V DC)

Power supply Voltage V 230

> Daikin Altherma high temperature

Page 20: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

20

▪ Pricelist

Daikin Altherma HT represents the most innovative solution for refurbishment

projects. Equipped with a double inverter cascade system, it can produce

leaving water temperatures up to 80°C, reached purely on thermodynamic

principles – without an additional direct electrical heater.

Change a boiler directly to Daikin Altherma HT - your radiators can stay, no

additional investments are necessary.

Daikin Altherma high temperature outdoor units

Inverter Split Heat pump System with nominal capacities from 11 to 16 kW. Nominal capacity is measured at A7/W65, delta T 5K.

Can only be combined with an indoor unit of the same capacity class and power supply.

PRICE CZK

Daikin Altherma HT 11kW outdoor unit ERRQ011AV1 Power Supply 1~ 230V 80.161,-

Daikin Altherma HT 14kW outdoor unit ERRQ014AV1 Power Supply 1~ 230V 95.810,-

Daikin Altherma HT 16kW outdoor unit ERRQ016AV1 Power Supply 1~ 230V 108.783,-

Daikin Altherma HT 11kW outdoor unit ERRQ011AY1 Power Supply 3~400V 91.794,-

Daikin Altherma HT 14kW outdoor unit ERRQ014AY1 Power Supply 3~400V 108.434,-

Daikin Altherma HT 16kW outdoor unit ERRQ016AY1 Power Supply 3~400V 123.637,-

Daikin Altherma high temperature indoor units (fl oorstanding) for heating only applications.

All basic necessary hydraulic components included. Domestic Hot water tank can be mounted on top of or next to the indoor unit

as an option. Can only be combined with an outdoor unit of the same capacity class and power supply.

PRICE CZK

Daikin Altherma HT 11kW indoor unit EKHBRD011ACV1 Floorstanding unit, power supply 1~ 230V 127.626,-

Daikin Altherma HT 14kW indoor unit EKHBRD014ACV1 Floorstanding unit, power supply 1~ 230V 132.500,-

Daikin Altherma HT 16kW indoor unit EKHBRD016ACV1 Floorstanding unit, power supply 1~ 230V 136.574,-

Daikin Altherma HT 11kW indoor unit EKHBRD011ACY1 Floorstanding unit, power supply 3~ 400V 131.235,-

Daikin Altherma HT 14kW indoor unit EKHBRD014ACY1 Floorstanding unit, power supply 3~ 400V 136.429,-

Daikin Altherma HT 16kW indoor unit EKHBRD016ACY1 Floorstanding unit, power supply 3~ 400V 141.177,-

INDOOR UNIT

EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1

230V 400V

OU

TD

OO

R U

NIT

23

0V

ERRQ011AV1 ● - – – – –ERRQ014AV1 – ● – – – –ERRQ016AV1 – – ● – – –

40

0V

ERRQ011AY1 – – – ● – –ERRQ014AY1 – – – – ● –ERRQ016AY1 – – – – – ●

Daikin Altherma cascade technology

High performance in 3 steps:

1 The outdoor unit extracts heat

from the ambient outdoor air. This

heat is transferred to the indoor unit

via R-410A refrigerant.

> Daikin Altherma high temperature

▪ Combinations

Page 21: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

21

Options & accessoriesApplicable for:

11-16kWPRICE CZK

Wired room thermostat EKRTWA Wired Digital Room Thermostat ● 3.938,-

Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● 6.713,-

Digital I/O PCB EKRP1HBA Remote alarm / operation status / … ● 4.144,-

Modbus PCD RTD-W Monitoring and control ModBus interface ● 10.538,-

Sequencing Controller EKCC-W Master/slave control kit that can control and monitor up

to 16 hydroboxes, connected through RTD-W ● 28.562,-

Thermostat external sensor EKRTETS Temperature measurement remotely from wireless

room thermostat (e.g. fl oor temperature) ● 516,-

Demand PCB for connection of room

thermostat or backup heater

EKRP1AHT Required when EKRTWA or EKRTR is used as a room

thermostat or if a backup heater is installed ● 4.158,-

Remote user interface EKRUAHTB Can be used as a second user interface (master/slave)

besides the one delivered with the indoor unit ● 6.177,-

In-line backup heater 1~, 230V, 6kW EKBUHA6V3 Electrical backup heater for space heating support only ● 18.198,-

In-line backup heater 3~, 400V, 6kW EKBUHA6W1 Electrical backup heater for space heating support only ● 18.198,-

Option kit for standalone tank EKFMAHTB Kit required when EKHTS tanks are to be placed next to the indoor unit ● 15.427,-

Domestic hot water connection kit for

EKHWP300B

EKEPHT3H Connection kit for HT in combination with EKHWP300B ● 7.836,-

Domestic hot water connection kit for

EKHWP500B

EKEPHT5H Connection kit for HT in combination with EKHWP500B ● 14.066,-

Domestic hot water tanksApplicable for:

11-16kWPRICE CZK

Stainless steel domestic hot water tank

200LEKHTS200AC

Domestic hot water tank 200L, Dimensions HxBxT = 1.335x600x695,

height increases to 2.010 mm if mounted on top of indoor unit ● 41.962,-

Stainless steel domestic hot water tank

260LEKHTS260AC

Domestic hot water tank 260L, Dimensions HxBxT = 1.610x600x695,

height increases to 2.285 mm if mounted on top of indoor unit ● 47.397,-

Pressureless 300L domestic hot water tank EKHWP300B Pressureless hygienic domestic hot water tank with solar option ● 44.212,-

Pressureless 500L domestic hot water tank EKHWP500B Pressureless hygienic domestic hot water tank with solar option ● 50.615,-

Outdoor Indoor

1 2 3Step Step Step

3

2 The indoor unit receives the heat

and further increases the temperature

with R-134a refrigerant.

The heat is transferred from the R-134a

refrigerant circuit to the water circuit.

Thanks to the unique cascade compressor

approach, water temperatures of 80°

C can be reached without using an

additional back-up heater.

> Daikin Altherma high temperature

Page 22: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

22

There is a growing demand from home owners to replace heating systems, especially replacing

of gas boilers, with more effi cient, more cost-eff ective and more environmentally friendly systems

that reduce CO2 emissions, reduce energy consumption and protect their budget.

The answer is the Rotex hybrid heat pump.

For space heating, the Rotex hybrid heat pump will combine air-to-water heat pump technology with gas condensing technology by searching for the optimum economical condition for its operation,

combining parameters of energy costs (electricity, gas), heat pump effi ciency and heat load

requirements to deliver up to 35% more heating effi ciency, plus major cost savings.

For domestic hot water, the Rotex hybrid heat pump optimises the operation

of the most effi cient gas condensing boiler.

Hybrid technol

ogy

> Rotex hybrid heat pump

For replacement of a gas boiler

A unique opportunity in residential heating!

Your benefi ts ü Low running costs for heating

and domestic hot water

compared to traditional boilers

ü Low investment cost

ü Provides suffi cient heat in

renovation applications

ü Easy and fast installation

NEW!

Page 23: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

23

Hybrid operation

-7 0 15

Required

heat output

kWh/°C

Ambient

temperature °C

Gas

operation

Heat pump

operation

Looking at an average European climate, the largest part of the required heat output is covered by the hybrid and

heat pump operation, resulting in up to 35% more heating effi ciency.

1800

1600

1400

1200

1000

800

600

400

200

0

Illustration of an average European climate

+ 35% effi ciency (space heating) compared to condensing boiler

• Heat load: 14 kW

• 70% heat pump output

• 30% gas boiler output

Heat load = the capacity of the space heating system required to maintain comfortable indoor temperatures at any time.

Required heat output = heat load x n° of occuring hours per year

Heat pump operation

The heat pump integrated in the Rotex hybrid heat pump is the best available technology for optimizing running costs

at moderate outdoor temperatures, resulting in a coeffi cient of performance of 5,041 !

(1) heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

Gas operation

When outdoor temperatures are dropping drastically, it is no longer effi cient to operate in hybrid mode. At that point,

the unit will switch automatically to gas operation only.

Hybrid operation

If a high heat load is required, or to achieve the highest effi ciencies at the current conditions, both the gas boiler and heat pump

operate at the same time in the most economical way.

The water fl ow rate will be automatically regulated, in order to have the possibility of lowering the temperature of the water

fl owing from the radiators to the heat pump and so maximizing heat pump effi ciency.

The exact time the switch-over is made from heat pump operation to hybrid operation depends on the house characteristics,

energy prices and the requested indoor temperature setting.

> Rotex hybrid heat pump NEW!

Page 24: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

24

HEATING ONLY

INDOOR UNIT RHYHBH05AAV3 RHYHBH08AAV3 RHYKOMB33AA3

Casing Colour White White - RAL9010

Material Precoated sheet metal

Dimensions Unit H x W x D mm 902x450x164 710x450x240

Weight Unit kg 30 31,2 36

Operation

range

Heating Ambient Min.~Max. °C -25~25 -~-

Water side Min.~Max. °C 25~55 15 (1)~80 (1)

Domestic hot water Water side Min.~Max. °C -~- 40~65

Power supply Name/Phase/Frequency/Voltage Hz/V V3 / 1~ / 50 / 230 -

(1) DB/WB 7°C/6°C - LWC 35°C (DT=5°C), boiler bypassed

OUTDOOR UNIT RVLQ05CV3 RVLQ08CV3

Heating

capacity

Min. kW 1,80 (1) / 1,80 (2)

Nom. kW 4,40 (1) / 4,03 (2) / 3,27 (3) 7,40 (1) / 6,89 (2) / 5,80 (3)

Max. kW 5,12 (1) / 4,90 (2) / 4,81 (3) 10,02 (1) / 9,53 (2) / 7,68 (3)

Power input Heating Nom. kW 0,87 (1) / 1,13 (2) / 1,23 (3) 1,66 (1) / 2,01 (2) / 1,64 (3)

COP 5,04 (1) / 3,58 (2) / 4,02 (3) 4,45 (1) / 3,42 (2) / 3,53 (3)

Dimensions Unit H x W x D mm 735x832x307

Weight Unit kg 54 56

Operation range Heating Min.~Max. °CWB -25~25

Refrigerant Type R-410A

Charge kg 1,45 1,60

Sound power level Heating Nom. dBA 61 62

Sound pressure level Heating Nom. dBA 48 49

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230

Current Recommended fuses A 20

(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C); (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C); (3) Condition: Ta DB/WB 2°C/1°C - LWC 35°C (Dt=5°C)

HEATING & COOLING

INDOOR UNIT RHYHBX08AAV3 RHYKOMB33AA3

Casing Colour White White - RAL9010

Material Precoated sheet metal

Dimensions Unit H x W x D mm 902x450x164 710x450x240

Weight Unit kg 31,2 36

Operation

range

Heating Ambient Min.~Max. °C -25~25 -~-

Water side Min.~Max. °C 25~55 15 (1)~80 (1)

Cooling Ambient Min.~Max. °C 10~43 -

Water side Min.~Max. °C 5~22 -

Domestic hot water Water side Min.~Max. °C -~- 40~65

Power supply Name V3 -

Phase 1~

Frequency Hz 50

Voltage V 230

OUTDOOR UNIT RVLQ08CV3

Heating

capacity

Min. kW 1,80 (1) / 1,80 (2)

Nom. kW 7,40 (1) / 6,89 (2) / 5,80 (3)

Max. kW 10,02 (1) / 9,53 (2) / 7,68 (3)

Cooling

capacity

Min. kW 2,50 (4) / 2,50 (5)

Nom. kW 6,86 (4) / 5,36 (5)

Power input Heating Nom. kW 1,66 (1) / 2,01 (2) / 1,64 (3)

Cooling Nom. kW 2,01 (4) / 2,34 (5)

COP 4,45 (1) / 3,42 (2) / 3,53 (3)

EER 3,41 (4) / 2,29 (5)

Dimensions Unit H x W x D mm 735x832x307

Weight Unit kg 56

Operation range Heating Min.~Max. °CWB -25~25

Refrigerant Type R-410A

Charge kg 1,60

Sound power level Heating Nom. dBA 62

Sound pressure level Heating Nom. dBA 49 (3)

Power supply Name/Phase/Frequency/Voltage Hz/V V3/1~/50/230

Current Recommended fuses A 20

(1) Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C); (2) Condition: Ta DB/WB 7°C/6°C - LWC 45°C (Dt=5°C); (3) Condition: Ta DB/WB 2°C/1°C - LWC 35°C (Dt=5°C)

(4) Cooling: Ta 35°C - LWE 18°C (DT=5°C); (5) Cooling: Ta 35°C - LWE 7°C (DT=5°C)

▪ Technical specifi cations

> Rotex hybrid heat pump NEW!

Page 25: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

25

▪ Pricelist

Daikin Altherma hybrid heat pump combines air-to-water heat pump technology with gas condensing technology by

searching for the optimum economical condition for its operation, combining parameters of energy costs (electricity, gas),

heat pump effi ciency and heat load requirements to deliver up to 35% more heating effi ciency, giving major cost savings.

Please note that a complete hybrid system consists of one outdoor unit, one hydro module, one gas boiler module, one

user interface and one cover plate.

DAIKIN Altherma hybrid heat pump - outdoor units PRICE CZK

Rotex Hybrid Outodoor unit 5kW RVLQ05CV3 Power Supply 1~ 230V 40.641,-

Rotex Hybrid Outodoor unit 8kW RVLQ08CV3 Power Supply 1~ 230V 58.276,-

DAIKIN Altherma hybrid heat pump - hydro module

(Controller needs to be ordered separately!)PRICE CZK

Rotex Hybrid indoor unit for 5kW

outdoor unit, heating only

RHYHBH05AAV3 power supply 1~ 230V, incl. high effi ciency pump, expansion vessle,

safety valve assembly, fl ow guard...etc. (W x D x H) 450 x 164 x 902

34.714,-

Rotex Hybrid indoor unit for 8kW

outdoor unit, heating only

RHYHBH08AAV3 power supply 1~ 230V, incl. high effi ciency pump, expansion vessle,

safety valve assembly, fl ow guard...etc. (W x D x H) 450 x 164 x 902

36.552,-

Rotex Hybrid indoor unit for 8kW

outdoor unit, heating & cooling

RHYHBX08AAV3 power supply 1~ 230V, incl. high effi ciency pump, expansion vessle,

safety valve assembly, fl ow guard...etc. (W x D x H) 450 x 164 x 902

38.568,-

DAIKIN Altherma hybrid heat pump - gas condensing combi boiler* PRICE CZK

Rotex Hybrid

Gas condensing combi boiler

7,9 - 31,9kW (80°C/60°C)

RHYKOMB33AA3 gas condensing combi boiler with special 2 in 1 heat exchanger for

space heating and instantaneous domestic hot water production,

for natural and liquid gas, (W x D x H) 450 x 240 x 710

51.351,-

*The gas boiler module is standard equipped with a concentric fl ue gas connection diameter 60/100.

*The gas boiler is certifi ed for following fl ue gas systems : C13, C33, C43, C53, C63, C83

Necessary accessories for a complete installation

(please only order one of the 7 controllers listed below)

Applicable for:PRICE CZK

5kW model 8kW model

Remote Controller RKRUCBL1 User interface with languages FR, NL, DE, IT ● ● 3.296,-

Remote Controller RKRUCBL2 User interface with languages EN, SV, FI, NO ● ● 3.296,-

Remote Controller RKRUCBL3 User interface with languages EN, ES, PT, EL ● ● 3.296,-

Remote Controller RKRUCBL4 User interface with languages EN, RO, PL, TR ● ● 3.296,-

Remote Controller RKRUCBL5 User interface with languages DE, SI, CZ, SK ● ● 3.296,-

Remote Controller RKRUCBL6 User interface with languages EN, HR, HU, BG ● ● 3.296,-

Remote Controller RKRUCBL7 User interface with languages EN, DA, RU, LT ● ● 3.296,-

Cover plate EKHY093467 Cover plate to hide the pipe

connections underneath the unit ● ● 671,-

Optional Accessories PRICE CZK

Propane Set EKHY075787 Kit for connection with liquid gas supply ● ● 305,-

Valve kit EKVK1A Valves for space heating, domestic

hot water an gas connection ● ● 3.478,-

Mounting jig EKHYMNT1A Jig to help mount the indoor unit onto the wall ● ● 7.479,-

Flue gas connector EKHY090707 connection for 2x80 parallel

connection (C53/C83) ● ● 488,-

Double-walled connection set EKHY090717 Concentric connection set from

DN 60/100 to DN 80/125 ● ● 549,-

U-beams for outdoor unit EKFT008CA Beams to mount outdoor unit on (height 25cm) ● ● 3.112,-

PC cable EKPCCAB2 Cable to upload fi eld settings from PC to unit ● ● 7.555,-

Drain pan kit for indoor unit EKHYDP Collect and drain condensate

during cooling operation ● ● 3.296,-

Drainpan for outdoor unit (exl. drainpan heater) EKDP008C Collect water from defrost cycle and drain

via central hole to remote location ● ● 4.997,-

Heater tape for outdoor unit drainpan EKDPH008C Heater tape to install in central hole of

drain pan to prevent ice blockage ● ● 7.555,-

Pressureless 300L domestic hot water tank EKHWP300B pressureless hygienic domestic hot

water tank with solar option ● ● 44.212,-

Pressureless 500L domestic hot water tank EKHWP500B pressureless hygienic domestic hot

water tank with solar option ● ● 50.615,-

Domestic hot water connection kit EKEPHT3H connection kit for combination with

EKHWP300B & EKHWP500B ● ● 7.836,-

> Rotex hybrid heat pump NEW!

Page 26: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

26

▪ Flue gas system for Daikin Altherma hybrid boiler

For the combination with the Daikin Altherma hybrid gas condensing boiler, Daikin off ers a robust white concentric PP-fl ue

system. To safeguard an optimal operation of the system, Daikin advises to use this fl ue gas system in combination with it’s

Daikin Altherma hybrid heat pump system. The fl ue gas system is easy to set up in combination with the Daikin Altherma

hybrid gas condensing boiler.

In order to make the selection of you fl ue gas system easier for you, please visit http://fl uegas.daikin.eu/ and use the Daikin

fl ue gas selector tool.

C33 TOP

C33 FLAT C93 C33S

C13

C43

C43

> Rotex hybrid heat pump NEW!

Page 27: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

27

C13, C33 concentric 60/100

Material name

Description Price CZK

EKFGP6837 Roof Terminal PP/GLV

60/100 AR460

1.892,-

EKFGS0518 Weather Slate Steep

Pb/GLV 60/100 18°-22°

2.747,-

EKFGS0519 Weather Slate Steep

Pb/GLV 60/100 23°-27°

2.747,-

EKFGP7910 Weather Slate Steep

PF 60/100 25°-45°

1.099,-

EKFGS0523 Weather Slate Steep

Pb/GLV 60/100 43°-47°

2.869,-

EKFGS0524 Weather Slate Steep

Pb/GLV 60/100 48°-52°

2.991,-

EKFGS0525 Weather Slate Steep

Pb/GLV 60/100 53°-57°

3.051,-

EKFGP1296 Weather Slate Flat Alu

60/100 0°-15°

1.709,-

EKFGP6940 Weather Slate Flat Alu

60/100

793,-

EKFGP2978 Kit horizontal PP/GLV

60/100

1.221,-

EKFGP2977 Kit horizontal low

profi le PP/GLV 60/100

1.526,-

EKFGP4651 Extension PP/GLV

60/100 x 500mm

793,-

EKFGP4652 Extension PP/GLV

60/100 x 1000mm

915,-

EKFGP4664 Elbow PP/GLV

60/100 30°

1.037,-

EKFGP4661 Elbow PP/GLV

60/100 45°

671,-

EKFGP4660 Elbow PP/GLV

60/100 90°

733,-

EKFGP4667 Meas. Tee with Inspection

Panel PP/GLV 60/100

2.563,-

EKFGP4631 Fixation / Wall Bracket

Dn.100

245,-

C13, C33 Concentric 80/125

Material name

Description Price CZK

EKFGP6864 Roof Terminal PP/GLV

80/125 AR300 Ral-9011

2.259,-

EKFGT6300 Weather Slate Steep

Pb/GLV 80/125 18°-22°

2.807,-

EKFGT6301 Weather Slate Steep

Pb/GLV 80/125 23°-27°

2.869,-

EKFGP7909 Weather Slate Steep PF

80/125 25°-45° Ral-9011

1.159,-

EKFGT6305 Weather Slate Steep

Pb/GLV 80/125 43°-47°

3.051,-

EKFGT6306 Weather Slate Steep

Pb/GLV 80/125 48°-52°

3.112,-

EKFGT6307 Weather Slate Steep

Pb/GLV 80/125 53°-57°

3.356,-

EKFGP1297 Weather Slate Flat

Alu 80/125 0°-15°

1.831,-

EKFGW5333 Weather Slate Flat

Alu 80/125

793,-

EKFGW6359 Wall Terminal Kit PP/

GLV 80/125

2.137,-

EKFGP4801 Extension PP/GLV

80/125 x 500mm

915,-

EKFGP4802 Extension PP/GLV

80/125 x 10000mm

977,-

EKFGP4814 Elbow PP/GLV

80/125 30°

1.037,-

EKFGP4811 Elbow PP/ALU

80/125 45°

793,-

EKFGP4810 Elbow PP/ALU

80/125 90°

793,-

EKFGP4820 Inspection Elbow Plus PP/

ALU 80/125 90° EPDM

2.014,-

EKFGP4481 Fixation / Wall Bracket

Dn.125

305,-

Multi Flex PP Dn.100 & Dn.130 C43 60/100 ONLY

Material name

Description Price CZK

EKFGP6368 Tee Flex 100 Boiler

Connectionset 1

4.760,-

EKFGP6354 Flex 100-60 +

Support Elbow

3.478,-

EKFGP6215 Tee Flex 130 Boiler

Connectionset 1

5.248,-

EKFGS0257 Flex 130-60 +

Support Elbow

3.906,-

EKFGP4678 Chimney Connection

60/100

1.221,-

EKFGP5461 Extension PP

60x500

245,-

Flex PP Dn.100 in combination with C43

Material name

Description Price CZK

EKFGP5497 Chimney Top PP

100 incl. Flue Pipe

2.502,-

EKFGP6316 Adapter Flex-Fixed

PP 100

1.159,-

EKFGP6337 Support Breaket

Top Inox Dn.100

549,-

EKFGP6346 Extension Flex PP

100 L=10 M

6.225,-

EKFGP6349 Extension Flex PP

100 L=15 M

9.337,-

EKFGP6347 Extension Flex PP

100 L=25 M

15.379,-

EKFGP6325 Connector Flex-

Flex PP 100

1.037,-

Flex PP Dn.130 in combination with C43

Material name

Description Price CZK

EKFGP5197 Chimney Top PP

130 incl. Flue Pipe

3.662,-

EKFGS0252 Adapter Flex-Fixed

PP 130

1.465,-

EKFGP6353 Support Breaket

Top Inox Dn.130

1.037,-

EKFGS0250 Extension Flex PP

130 L=30 M

20.140,-

EKFGP6366 Connector Flex-

Flex PP 130

1.526,-

Flex PP Dn.60-80 C93/C33s

Material name

Description Price CZK

EKFGP1856 Flex Kit PP Dn.60-

80

6.285,-

EKFGP4678 Chimney

Connection 60/100

1.221,-

EKFGP2520 Flex Kit PP Dn.80 7.140,-

EKFGP4828 Chimney

Connection 80/125

1.221,-

EKFGP6340 Extension Flex PP

80 L=10 M

5.126,-

EKFGP6344 Extension Flex PP

80 L=15 M

7.690,-

EKFGP6341 Extension Flex PP

80 L=25 M

11.779,-

EKFGP6342 Extension Flex PP

80 L=50 M

21.971,-

EKFGP6324 Connector Flex-

Flex PP 80

915,-

EKFGP6333 Spacer PP 80-100 305,-

> Rotex hybrid heat pump NEW!

Page 28: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

28

Geothermal energy is a free source of energy for heating, and domestic

hot water. It delivers enormous cost savings in even

the coldest climates as the energy is at a relatively constant temperature

all year round. The compact design of the inside unit requires very

little space whilst, at the same time, making the system very

easy and quick to install. And, once commissioned, our easy,

user-friendly controls put the user in complete command.

For new build and replacement of boilers

> Daikin Altherma ground source heat pump

A new opportunity

for heating and domestic hot water.

NEW!

Daikin Altherma ground source heat pump horizontal Daikin Altherma ground source heat pump vertical

Page 29: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

29

Cap

acit

y (k

W)

Ambient temperature (Ta) °C

Typical application:

• Location: Sweden

• Design temperature: -17°C

• Heat load: 13kW

• Heating off temperature: 16°C

Heat load line

Traditional ON/OFF unit

Daikin unit

BUH* = Back-up heater

High seasonal effi ciency thanks

to our inverter heat pump technologyThe Daikin inverter heat pump technology has been shown to provide an increase in seasonal efficiency of up to

20% when compared to traditional on/off ground source heat pumps.

• The brine, a water/anti-freeze mixture that operates as heat transfer medium between the ground and the heat pump,

is kept at a higher stable temperature

• Back up operation is reduced to a minimum

• High operating efficiencies of the compressor are reached at partial load operation, i.e. when no full capacity of

the unit is required.

• This results in reduced running costs and a faster return on investment.

When no full capacity is required of the system the compressor works in partial load. In partial load conditions, a traditional

on/off ground source heat pump sequently switches ON and OFF, whereby the brine temperature decreases down to

-4°C when the unit is operating. Daikin’s inverter technology results in a stable outgoing brine temperature of around 0°C.

This increased stability in brine temperature results in a higher and more constant evaporating temperature which leads to

higher operating effi ciencies.

Compared to a traditional On/Off unit, the requirement for support from the back up heater is much lower for the

Daikin Altherma ground source heat pump, thanks to the boosting eff ect of our inverter compressors, also this leads to

lower running costs.

Less back up heater operation thanks to the boosting of the inverter compressor

frequency

10

8

6

4

2

0

-2

-4

-6

-8

10

8

6

4

2

0

-2

-4

-6

-8

T (°C) T (°C)

Outgoing Brine Temperature (HP as reference)

Operation ON/OFF unit

Partial load condition - ON/OFF

Operation Daikin unit

Partial load condition - Inverter controlled

tt

Outgoing Brine Temperature (HP as reference)

ON ON

ON

OFFOFF

Case study

Higher brine temperatures during continuous

compressor operation, in partial load conditions

BUH*

Required heat output of

your home

> Daikin Altherma ground source heat pump NEW!

Page 30: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

30

HEATING ONLY

INDOOR UNIT EGSQH10S18A9W

Heating

capacity

Min. kW 3,11 (1) / 2,47 (2)

Nom. kW 10,2 (1) / 9,29 (2)

Max. kW 13,0 (1) / 11,9 (2)

Power input Nom. kW 2,34 (1) / 2,82 (2)

COP 4,35 (1) / 3,29 (2)

Casing Colour White

Material Precoated sheet metal

Dimensions Unit HxWxD mm 1.732x600x728

Weight Unit kg 210

Tank Water volume l 180

Insulation Heat loss kWh/24h 1,36

Corrosion protection Anode

Operation

range

Installation

space

Min.~Max. °C 5~30

Brine side Min.~Max. °C -5~20

Heating Water side Min.~Max. °C 24~60 (heat pump) / 65 (heat pump + back up heater)

Domestic hot water Water side Min.~Max. °C 24~60 (heat pump) / 60 (back up heater)

Refrigerant Type R-410A

Charge kg 1,8

Sound power level Nom. dBA 46

Sound pressure level Nom. dBA 32

Power supply Name 9W

Phase 3~

Frequency Hz 50

Voltage V 400

Current Recommended fuses A 32

(1) EWB/LWB 0°C/-3°C - LWC 35°C (DT=5°C)

(2) EWB/LWB 0°C/-3°C - LWC 45°C (DT=5°C)

▪ Technical specifi cations

> Daikin Altherma ground source heat pump NEW!

Page 31: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

31

> Daikin Altherma ground source heat pump

▪ Pricelist

The Daikin Altherma ground source heat pump system features a compact indoor unit with a fully integrated inverter heat

pump module and hot water tank. It needs to be combined with either a deep or shallow collector to draw energy from

the ground. It is easy to use too, with smart room temperature controls and an energy usage display, helping to reduce

energy consumption, while ensuring high levels of comfort.

DAIKIN Altherma ground source heat pump PRICE CZK

Daikin Altherma ground source heat pump

10kW

EGSQH10S18A9W Daikin Altherma ground source heat pump unit

incl. 180L DHW tank

224.079,-

Necessary accessories for a complete installation

(please only order one of the 7 controllers listed below)PRICE CZK

Controller EKRUCBL1 User interface with languages FR, NL, DE, IT 3.296,-

Controller EKRUCBL2 User interface with languages EN, SV, FI, NO 3.296,-

Controller EKRUCBL3 User interface with languages EN, ES, PT, EL 3.296,-

Controller EKRUCBL4 User interface with languages EN, RO, PL, TR 3.296,-

Controller EKRUCBL5 User interface with languages DE, SI, CZ, SK 3.296,-

Controller EKRUCBL6 User interface with languages EN, HR, HU, BG 3.296,-

Controller EKRUCBL7 User interface with languages EN, DA, RU, LT 3.296,-

Optional accessories PRICE CZK

Digital I/O PCB EKRP1HBA Remote alarm / operation status / … 4.144,-

Brine fi lling kit KGSFILL Kit to fi l land fl ush the brine circuit 4.699,-

Demand PCB EKRP1AHT Power consumption limitation with 4 digital inputs on hydrobox 4.158,-

Remote indoor sensor KRCS01-1 Temperature measurement remotely from user interface 2.432,-

PC cable EKPCCAB2 Cable to upload fi eld settings from PC to unit 7.555,-

Wired room thermostat EKRTWA Wired Digital Room Thermostat 3.938,-

Wireless room thermostat EKRTR Wireless Digital Room Thermostat 6.713,-

Thermostat external sensor EKRTETS Temperature measurement remotely from wireless

room thermostat (e.g. fl oor temperature)516,-

NEW!

Page 32: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

32

One or more outdoor units

+ several indoor units

>> a modular system

Outdoor unit

Indoor installationDomestic hot

water tank

= +

Heating/Cooling

Indoor unit

Hot water

1 2Heating

3Cooling

Fit for purpose &Hot water on demand

The challenges for a fi tness center:

• Large exercise rooms with high levels

of heat being generated requiring

rigorous climate control throughout

the space

• High ‘on demand’ hot water usage

in the changing rooms

The solution:

• Daikin Altherma

Flex Type with its

modular and fl exible

approach.

Effi cient climate control for

residential applications

Commercial applications

Outdoor

1

2

3

> Daikin Altherma Flex Type

Page 33: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

33

1 Commercial space /

1 ApartmentTotal building

20kW

22kW

40kW

45kWInstall separate

outdoor units to reach higher

capacities

(Separate system:

the outdoor units are not

connected to each other)

Note:

Heating capacities 7°C ambient

temperature, cooling capacities

35°C ambient temperature

6kW 9kW 11kW 14kW 16kW

5kW 8kW

3-IN-1 SYSTEM

Daikin Altherma Flex Type heats, cools and produces domestic hot water:

• Heating: leaving water temperatures up to 80° C

• Cooling: leaving water temperatures down to 5° C

• Hot water: tank temperatures up to 75° C

Thanks to the heat recovery function, the system can heat up the hot water tank up to 60°C with rejected heat from

cooling operation.

ENERGY EFFICIENT HEAT PUMP TECHNOLOGY

Compared to an oil boiler, this results in:

• Up to 36% less running costs*

• Up to 71% reduction of CO2 emissions*

• Up to 35% reduction in primary energy use*

* Data calculated taking in account Belgian conditions: SCOP of 3, average energy prices 2007-2010, CO2 emission factor for electricity production

MODULAR SYSTEM

One or more inverter-controlled outdoor heat pump units can provide heating, cooling and hot water. Outdoor units

between 23 and 45 kW extract the heat from the outdoor air, raise it to an intermediate temperature and transfer this heat

energy to the individual indoor units.

Indoor units are available in several classes (6, 9, 11 ,14 and 16 kW), ensuring optimum effi ciency. One outdoor unit can be

combined with up to ten indoor units. Multiple outdoor units can be installed for larger applications.

3P, 400V1P, 230V

> Daikin Altherma Flex Type

Page 34: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

34

▪ Technical specifi cations

OUTDOOR UNIT EMRQ8A EMRQ10A EMRQ12A EMRQ14A EMRQ16A

Heating capacity Nom. kW 22,4 28 33,6 39,2 44,8

Cooling capacity Nom. kW 20 25 30 35 40

Dimensions Unit HxWxD mm 1.680x1.300x765

Weight Unit kg 331 339

Operation

range

Heating Min.~Max. °CWB -15~20

Domestic hot water Ambient Min.~Max. °CDB -15~35

Cooling Min.~Max. °CDB 10~43

Refrigerant Type R-410A

Piping

connections

Liquid OD mm 9,52 12,7

Suction OD mm 19,1 22,2 28,6

High and low pressure gas OD mm 15,9 19,1 22,2

Piping length OU - IU Max. m 100

System Equivalent m 120

Total piping length System Actual m 300

Sound power level Heating Nom. dBA 78 80 83 84

Sound pressure level Heating Nom. dBA 58 60 62 63

Power supply Phase/Voltage V 3~/380-415

Heating conditions: Ta = 7°CDB / 6°CWB, 100% connection ratio

Cooling conditions: Ta = 35°CDB, 100% connection ratio

* Capacity not guaranteed between -20°C and -15°C

> Daikin Altherma Flex Type

Page 35: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

35

INDOOR UNIT EKHVMRD50A EKHVMRD80A EKHVMYD50A EKHVMYD80A

Casing Colour Metallic grey

Material Precoated sheet metal

Dimensions Unit HxWxD mm 705x600x695

Weight Unit kg 92 120

Operation

range

Heating Ambient Min.~Max. °C -15~20

Water side Min.~Max. °C 25~80

Cooling Ambient Min.~Max. °CDB -~- 10~43

Water side Min.~Max. °C -~- 5~20

Domestic hot

water

Ambient Min.~Max. °CDB -15~35

Water side Min.~Max. °C 45~75

Refrigerant Type R-134a

Charge kg 2

Sound pressure

level

Nom. dBA 40 1 / 43 2 42 1 / 43 2 40 1 / 43 2 42 1 / 43 2

Night quiet mode Level 1 dBA 38 1

Power supply Name V1

Phase 1~

Frequency Hz 50

Voltage V 220-240

Current Recommended fuses A 20

INDOOR UNIT EKHBRD011ACV1 EKHBRD014ACV1 EKHBRD016ACV1 EKHBRD011ACY1 EKHBRD014ACY1 EKHBRD016ACY1

Casing Colour Metallic grey

Material Precoated sheet metal

Dimensions Unit HxWxD mm 705x600x695

Weight Unit kg 144,25 147,25

Operation

range

Heating Ambient Min.~Max. °C -20~20

Water side Min.~Max. °C 25~80

Cooling Ambient Min.~Max. °CDB -~-

Water side Min.~Max. °C -~-

Domestic hot

water

Ambient Min.~Max. °CDB -20~35

Water side Min.~Max. °C 25~80

Refrigerant Type R-134a

Charge kg 3,2

Sound pressure

level

Nom. dBA 43 1 / 46 2 45 1 / 46 2 46 1 / 46 2 43 1 / 46 2 45 1 / 46 2 46 1 / 46 2

Night quiet mode Level 1 dBA 40 1 43 1 45 1 40 1 43 1 45 1

Power supply Name V1 Y1

Phase 1~ 3~

Frequency Hz 50

Voltage V 220-240 380-415

Current Recommended fuses A 25 16

(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C

> Daikin Altherma Flex Type

Page 36: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

36

Daikin Altherma Flex Type outdoor units.

Nominal heating capacity is measured at Ta 7°C and nominal cooling capacity at Ta 35°C with a 100% connection ratio. PRICE CZK

Daikin Altherma Flex outdoor unit 8HP EMRQ8A Outdoor unit with 22,4kW heating and 20kW

cooling capacity, power suppy 3~ 400V

256.069,-

Daikin Altherma Flex outdoor unit 10HP EMRQ10A Outdoor unit with 28 kW heating and 25kW cooling

capacity, power suppy 3~ 400V

327.514,-

Daikin Altherma Flex outdoor unit 12HP EMRQ12A Outdoor unit with 33,6kW heating and 30kW

cooling capacity, power suppy 3~ 400V

372.323,-

Daikin Altherma Flex outdoor unit 14HP EMRQ14A Outdoor unit with 39,2kW heating and 35kW

cooling capacity, power suppy 3~ 400V

388.972,-

Daikin Altherma Flex outdoor unit 16HP EMRQ16A Outdoor unit with 44,8kW heating and 40kW

cooling capacity, power suppy 3~ 400V

478.315,-

Daikin Altherma Flex Type indoor units (fl oorstanding) for heating& cooling and heating only applications.

All basic necessary hydraulic components included. PRICE CZK

Daikin Altherma Flex 5kW indoor unit

heating only

EKHVMRD50A Power Supply 1~ 230V 129.521,-

Daikin Altherma Flex 5kW indoor unit

heating & cooling

EKHVMYD50A Power Supply 1~ 230V 143.646,-

Daikin Altherma Flex 8kW indoor unit

heating

EKHVMRD80A Power Supply 1~ 230V 133.781,-

Daikin Altherma Flex 8kW indoor unit

heating & cooling

EKHVMYD80A Power Supply 1~ 230V 147.853,-

Daikin Altherma Flex 11kW indoor unit

heating only

EKHBRD011ACV1 Power Supply 1~ 230V 127.626,-

Daikin Altherma Flex 14kW indoor unit

heating only

EKHBRD014ACV1 Power Supply 1~ 230V 132.500,-

Daikin Altherma Flex 16kW indoor unit

heating only

EKHBRD016ACV1 Power Supply 1~ 230V 136.574,-

Daikin Altherma Flex 11kW indoor unit

heating only

EKHBRD011ACY1 Power Supply 3~400V 131.235,-

Daikin Altherma Flex 14kW indoor unit

heating only

EKHBRD014ACY1 Power Supply 3~400V 136.429,-

Daikin Altherma Flex 16kW indoor unit

heating only

EKHBRD016ACY1 Power Supply 3~400V 141.177,-

▪ Pricelist

Daikin Altherma Flex Type for residential and commercial applications is a

3-in-1 system off ering heating, domestic hot water and cooling all-in-one

highly effi cient.

Daikin Altherma Flex Type achieves a typical seasonal COP of 3 in the

moderate Western and central European climate. Further more, Daikin

Altherma Flex Type is a modular system. Depending from your project one

or more outdoor units can be combined with up to ten indoor units per

outdoor unit.

> Daikin Altherma Flex Type

Page 37: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

37

Options & accessoriesApplicable for:

11-16kWPRICE CZK

Wired room thermostat EKRTWA Wired Digital Room Thermostat ● 3.938,-

Wireless room thermostat EKRTR Wireless Digital Room Thermostat ● 6.713,-

Digital I/O PCB EKRP1HBA Remote alarm / operation status ● 4.144,-

Modbus Interface RTD-W monitoring and control ModBus interface ● 10.538,-

Sequencing Controller EKCC-W master/slave control kit that can control and monitor up

to 16 hydroboxes, connected through RTD-W ● 28.562,-

Thermostat external sensor EKRTETS Temperature measurement remotely from wireless

room thermostat (e.g. fl oor temperature) ● 516,-

Demand PCB for connection of room

thermostat or backup heater

EKRP1AHT required when EKRTWA or EKRTR is used as a room

thermostat or if a backup heater is installed ● 4.158,-

Remote user interface EKRUAHTB can be used as a second user interface (master/slave)

besides the one delivered with the indoor unit ● 6.177,-

In-line backup heater 1~, 230V, 6kW EKBUHA6V3 Electrical backup heater for space heating support only ● 18.198,-

In-line backup heater 3~, 400V, 6kW EKBUHA6W1 Electrical backup heater for space heating support only ● 18.198,-

Option kit for standalone tank EKFMAHTB Kit required when EKHTS tanks are to be placed next to the indoor unit ● 15.427,-

Optionional billing kit EKMBIL1 Option kit for billing of tank mounted on indoor unit ● 4.308,-

Central drainpan kit for outdoor unit KWC25C450 drain pan kit to collect the condensate after defrost operation ● 36.601,-

Domestic hot water connection kit for

EKHWP300B

EKEPHT3H connection kit for HT in combination with EKHWP300B ● 7.836,-

Domestic hot water connection kit for

EKHWP500B

EKEPHT5H connection kit for HT in combination with EKHWP500B ● 14.066,-

Domestic hot water tanksApplicable for:

11-16kWPRICE CZK

Stainless steel domestic hot water tank

200L

EKHTS200AC Domestic hot water tank 200L, Dimensions HxBxT = 1335x600x695,

height increases to 2010 if mounted on top of indoor unit ● 41.962,-

Stainless steel domestic hot water tank

260L

EKHTS260AC Domestic hot water tank 200L, Dimensions HxBxT = 1610x600x695,

height increases to 2285 if mounted on top of indoor unit ● 47.397,-

Pressureless 300L domestic hot water tank EKHWP300B pressureless hygienic domestic hot water tank with solar option ● 44.212,-

Pressureless 500L domestic hot water tank EKHWP500B pressureless hygienic domestic hot water tank with solar option ● 50.615,-

Refrigerant branch kits for outdoor units 3 pipes 3 pipes

Outdoor unit capacity type (HP) imperial metric imperial metric

8 + 10 KHRQ23M29T9 KHRQM23M29T KHRQ22M29T9 KHRQM22M29T

Price CZK 5.046,- 5.046,- 4.542,- 4.542,-

12 ~ 16 KHRQ23M64T KHRQM23M64T KHRQ22M64T KHRQM22M64T

Price CZK 8.223,- 8.223,- 5.492,- 5.492,-

Refnet joints for indoor units 3 pipes 3 pipes

Indoor unit capacity index imperial metric imperial metric

< 200 KHRQ23M20T KHRQM23M20T KHRQ22M20T KHRQM22M20T

Price CZK 4.424,- 4.424,- 3.384,- 3.384,-

200 ≤ x < 290 KHRQ23M29T9 KHRQM23M29T KHRQ22M29T9 KHRQM22M29T

Price CZK 5.046,- 5.046,- 4.542,- 4.542,-

290 ≤ x < 520 KHRQ23M64T KHRQM23M64T KHRQ22M64T KHRQM22M64T

Price CZK 8.223,- 8.223,- 5.492,- 5.492,-

Refnet headers for indoor units 3 pipes 3 pipes

Indoor unit capacity index imperial metric imperial metric

<200 and 200 ≤ x < 290 KHRQ23M29H KHRQM23M29H KHRQ22M29H KHRQM22M29H

Price CZK 8.966,- 8.966,- 6.381,- 6.381,-

290 ≤ x < 520 KHRQ23M64H KHRQM23M64H KHRQ22M64H KHRQM22M64H

Price CZK 10.923,- 10.923,- 7.896,- 7.896,-

> Daikin Altherma Flex Type

Page 38: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

38

The heat pump convector unit can provide both heating and cooling if required, since the heat

pump convector is more than just a fan coil unit.

The heat pump convector also has a very low noise level.

When combining under fl oor heating and fan coil units, the

low leaving water temperatures, important for effi ciency,

are adequate for under fl oor heating, but the fan coil units

then need to be oversized in order to emit the proper levels

of heat at these low water temperatures. The heat pump

convector solves this problem.

The heat pump convector is able to emit the required

levels of heat at low leaving water temperatures, while

retaining a modest size.

Instead of the leaving water circuit being switched on

and off via a thermostat in a single master room, each

heat pump convector can be directly wired to the Daikin

Altherma indoor unit, the system’s intelligence centre. This

allows all rooms to have heat when required, regardless of

the state of the other rooms.

The heat pump convector saves on running costs thanks to the improved effi ciency by approximately

25% compared to a heating system that combines under-

fl oor heating and regular fan coil units. The heat pump

convector can easily replace existing heat emitters, thanks

to its plug and play installation.

Heat pump convector

> Heat pump convector

Page 39: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

39

INDOOR UNITS FWXV20A FWXV15A

Heating capacity Total capacity Nom. kW 2,0 1,5

Cooling capacity Total capacity Nom. kW 1,7 1,2

Sensible

capacity

Nom. kW 1,4 0,98

Power input Heating Nom. kW 0,015 0,013

Cooling Nom. kW 0,015 0,013

Dimensions Unit H x W x D mm 600/700/210

Weight Unit kg 15

Piping connections Drain/OD/Inlet/Outlet mm/

inch18/G 1/2/G 1/2

Sound pressure

level

Heating Nom. dBA 29 19

Cooling Nom. dBA 29 19

Power supply Phase/Frequency/Voltage Hz/V 1~/50/60/220-240/220

(1) Cooling: indoor temp. 27°CDB, 19°CWB; entering water temp. 7°C, water temperature rise 5K.

(2) Heating: room temperature 20°CDB and entering water temperature 45°C, water temperature drop 5K.

▪ Technical specifi cations

Daikin Altherma Heat pump Convector PRICE CZK

Daikin Altherma

Heat pump Convector 1,5kW

FWXV15A Heat pump convector with 1,5kW* heating capacity

and 1,2kW** and 0,3kW*** cooling capacity 19.149,-

Daikin Altherma

Heat pump Convector 2,0kW

FWXV20A Heat pump convector with 2,0kW* heating capacity

and 1,7kW** and 0,4kW*** cooling capacity 20.701,-

Options & Accessories PRICE CZK

2 way valve kit EKVKHPC needs to be used in all cooling and high temperature applications, where

watertemperatures of below 18°C and/or 60°C or above can occur 2.651,-

* water inlet temperature 45°C and water outlet temperature 40°C, room temperature 20°C DB - medium fanspeed

**water inlet temperature 7°C and water outlet temperature 12°C, room temperature 27°C DB / 19°C WB - medium fanspeed

***water inlet temperature 18°C and water outlet temperature 23°C, room temperature 27°C DB / 19°C WB - medium fanspeed

▪ Pricelist

Daikin‘s Heat pump convector with interlink function is another heating

innovation coming from the Daikin internal product development. Perfectly

suitable for low temperature applications, e.g. in combination with underfl oor

heating, the Heat pump convector is a stylish, compact, intelligent and very

silent solution for quick heating or cooling of residential areas.

> Heat pump convector

Page 40: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

40

Solar kit

The solar kit provides the transfer of solar heat to the Daikin

Altherma hot water tank via an external heat exchanger.

In contrast to tanks with two heat exchangers, this system

allows the entire content of the tank to be effi ciently heated

with solar heat and, if necessary, with heat pump energy.

Solar collector

The high-effi ciency collectors transfer all the short-wave

solar radiation into heat as a result of their highly selective

coating. The collectors can be mounted on the roof tiles.

Pressurised system

The system is fi lled with heat transfer fl uid with the correct

amount of of antifreeze to avoid freezing in winter. The

whole system is then pressurised and sealed.

Pressureless system

The system is fi lled with pure water which is transferred

from the pressureless energy storage tank, whenever the

sun is out. If no sun is out and thus no energy is needed, the

water is drained back into the pressureless energy storage

tank.

What do you need?

• Solar collector

• Plumbing network and solar pump station

• Supply tank: standard Daikin Altherma domestic hot

water tank

• Solar kit

• Re-heater (Daikin Altherma heat pump unit which also

provides the home with heating)

Solar connection

> Daikin solar system

1- Solar collector

2- Solar pump station

3- Solar kit available in combination with stand alone

(EKHWS - EKHWE) domestic hot water tank

3

2

1

Daikin off ers two types of solar

systems in combination with

their heat pumps.

Page 41: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

41

Solar collectors

Averaged over an entire year, the sun

delivers half of the energy we need to bring

our domestic hot water up to the desired

temperature. High-effi ciency collectors

with highly selective coating transfer all the

short-wave solar radiation into heat. The

collectors can be mounted on roof tiles.

Operation

The solar collectors are only fi lled with

water when suffi cient heat is provided by

the sun. In this case, both pumps in the

control and pump unit switch on briefl y

and fi ll the collectors with storage tank

water. After fi lling, which takes less than

a minute, one of the pumps switches off

and water circulation is maintained by the

remaining pump.

1. Cold water connection

2. Hot water connection

3. Storage tank charging flow

4. Storage tank charging return flow

5. Heating support flow

6. Heating support return

7. Drain Back solar flow

8. Storage tank (polypropylene double

walled jacket with PUR hard foam heat

insulation)

9. Mount for solar R3 controller / handle

10. Safety overflow connection

11. Drain-back solar - return flow / Filling

and draining connection for storage

tank water

12. Fill level indicator

13. Connection for booster heater

14. Electric immersion booster heater

15. Sensor pocket for tank temperature

sensor

16. Domestic hot water heat exchanger

17. Charging heat exchanger

18. Inlet from solar collector

19. Pressure-free storage tank water

20. Solar zone

21. Hot water zone

> Daikin solar system

EKHWP: domestic hot water tank

The domestic hot water tank has two sections: The upper, always hot, section – the active water zone – and the

lower, colder section – the solar zone.

1. The active water is heated in the upper section of the storage tank. The high temperature of this zone

ensures that sufficient hot water is always available.

2. Solar collectors work more efficiently when colder water flows through the solar collectors. Therefore, the water

that is fed directly to the solar collectors in solar operation is stored in the solar zone.

1413

126

5 71

24

3

1010

8

18

9

2417

16

9

11

1519

20

21

23

Solar collector

Indoor unit and

domestic hot water tank

Page 42: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

42

SOLAR CONNECTION EKSOLHWAV1

Dimensions Unit H x W x D mm 770x305x270

Weight Unit kg 8

Operation

range

Ambient

temperature

Min,~Max, °C1~35

Sound pressure

level

Nom, dBA27

Thermal

performance

Zero loss collector effi ciency η0

%-

Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240

Power supply intake Indoor unit

ACCESSORY EKSR3PA

Mounting On wall

Dimensions Unit H x W x D mm 332x230x145

Thermal

performance

Zero loss collector effi ciency η0

%-

Control Type Digital temperature diff erence controller with plain text display

Power consumption W 2

Sensor Solar panel temperature sensor Pt1000

Storage tank sensor PTC

Return fl ow sensor PTC

Feed temperature and fl ow sensor Voltage signal (3,5V DC)

Power supply Frequency/Voltage Hz/V 50/230

SOLAR COLLECTOR EKSV26P EKSH26P EKSV21P

Dimensions Unit H x W x D mm 2,000x1,300x85 1,300x2,000x85 2,000x1,006x85

Weight Unit kg 42 35

Volume l 1,7 2,1 1,3

Surface Outer m² 2,601 2,01

Aperture m² 2,364 1,795

Absorber m² 2,354 1,791

Coating Micro-therm (absorption max,96%, Emission ca, 5% +/-2%)

Absorber Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate

Glazing Single pane safety glass, transmission +/- 92%

Allowed roof

angle

Min,~Max, °C15~80

Operating

pressure

Max, bar6

Stand still

temperature

Max, °C200

Thermal

performance

Zero loss collector effi ciency η0

% 78,7 78,3

Heat loss coeffi cient a1 W/m²,K 4,270 4,25

Temperature dependence of

the heat loss coeffi cient a2

W/

m²,K²0,0070 0,0057

Thermal capacity kJ/K 6,5 -

Incident

angle

modifi er

AM at 50°

0,94 -

Installed position Vertical Horizontal Vertical

SOLAR CONNECTION EKSRPS3B

Dimensions Unit H x W x D mm -

Control Type Digital temperature diff erence controller with plain text display

Power consumption W -

Mounting On side of tank

Sensor Solar panel temperature sensor Pt1000

Storage tank sensor PTC

Return fl ow sensor PTC

Feed temperature and fl ow sensor Voltage signal (3,5V DC)

> Daikin solar system

▪ Technical specifi cations

Page 43: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

43

> Daikin solar system

▪ Pricelist

For Daikin Altherma LT, HT and Flex units a pressurised and pressureless solar system is available. Main components are the standard Daikin tanks as well as pressureless hygienic domestic hot water tanks, combined with Daikin‘s solar kits and controllers and solar panels for on-roof, in-roof and fl at roof installations.

Material Description Price per unit CZK

Solar Panel EKSV26P Vertical big solar panel 2000 x 1300 mm21.053,-

EKSH26P Horizontal big solar panel 2000 x 1300 mm21.689,-

EKSV21P Vertical small solar panel 2000 x 1006 mm17.896,-

Daikin hot water tanks & accessories EKHWS* Stainless steel tank see page 9

EKHWE* Enameled tank see page 9

EKSOLHW Solar heat exchanger kit 23.134,-

EKHWP300B Hygienic Domestic hot water tank, 300l 44.212,-

EKHWP500B Hygienic Domestic hot water tank, 500l 50.615,-

165070 Set of 2 gravity brakes 456,-

164102-RTX FLG FLG - fl ow regulating valve with fl ow rate indicator 2.279,-

156015 VTA32 Thermostatic antiscald mixing valve 2.888,-

156016 1“ screw connection set for VTA32 1.140,-

162070 MAGS12 Solar Expansion Vessel 12L 4.388,-

162050 MAGS25 Solar Expansion Vessel 25L 5.320,-

162051-RTX MAGS35 Solar Expansion Vessel 35L 8.209,-

Solar Controlers & Pump Stations EKSRPS3B Solar controller for drain back applications 22.918,-

EKSR3PA Solar controller for pressurized applications 10.214,-

EKSRDS1A Solar pump station 15.155,-

164116 Flow sensor for a pressurized system 4.694,-

Solar priority PCB + cable EKRP1HBA PCB kit to disable hot water mode through HP during solar water heating 4.144,-

164110-RTX BSKK Solar priority cable / connection cable to disable heatpump 684,-

Solar panel installation accessories 164732 CON15 Pressureless Connection piping between solar panel & pump station: 15m 5.244,-

164733 CON20 Pressureless Connection piping between solar panel & pump station: 20m 6.232,-

164261-RTX CONX25 Pressureless elongation pipe 2,5m including couplings 3.268,-

164262-RTX CONX50 Pressureless elongation pipe 5m including couplings 3.725,-

164263 CONX100 Pressureless elongation pipe 10m including couplings 4.864,-

164264 CONXV80 Pressureless elongation for inlet pipe 8m 4.181,-

162073 CON15P16 Pressure solar pipe DN16 - 15m 18.849,-

162071 CONXP16 Connectors DN16 456,-

162074 CON15P20 Pressure solar pipe DN20 - 15m 23.333,-

162072 CONXP20 Connectors DN20 684,-

162075 CONCP16 Pressure solar connection set DN 16 2.351,-

162076 CONCP20 Pressure solar connection set DN 20 3.384,-

EKSRCRP Connection kit, incl. red roof tile 8.164,-

EKSRCAP Connection kit, incl. anthracite roof tile 8.164,-

EKSRCP Connection kit ON ROOF 5.906,-

162037-RTX RCIP Mounting kit IN-ROOF 5.169,-

162038-RTX RCFP Mounting kit FLAT ROOF 9.880,-

164709 CONFE Additional roof breakthrough for opposite side connection 3.041,-

162016-RTX FIXVBP Connection kit between 2 solar panels 2.128,-

162035-RTX CONRVP Connection kit between 2 rows of collectors 2.736,-

162045 CONLCP Connection kit between 2 rows of collectors 4.181,-

162066 FIXMP100 Mounting rail for V21 1.520,-

162067 FIXMP130 Mounting rail for V26P 1.672,-

162068 FIXMP200 Mounting rail for H26P 2.279,-

164245 TS Suporting shell for pressureless connection pipe 304,-

162036-RTX FIXADP Variable height mounting set for on-roof mounting suitable for roof tiles 3.725,-

162069 FIXADD Standard mounting set for on-roof mounting suitable for roof tiles 746,-

164723 FIXADS Mounting set for on-roof mounting suitable for fl at tiles e.g. shingles 2.203,-

164703-RTX FIXWD Mounting set for on-roof mounting suitable for corrugated plates 2.128,-

164704-RTX FIXBD Mounting set for on-roof mounting suitable for metal roofs 2.509,-

162017 IBV21P Basic IN ROOF installation kit for 2 EKSV21P 18.849,-

162018 IEV21P Extension IN ROOF installation kit for 1 additional EKSV21P 8.437,-

162019 IBV26P Basic IN ROOF installation kit for 2 EKSV26P 20.142,-

162020 IEV26P Extension IN ROOF installation kit for 1 additional EKSV26P 8.816,-

164616-RTX FIXIES IN ROOF covering slate complementing kit 4.940,-

162058 FBV26P Basic FLAT ROOF support frame for 2 EKSV26P 22.649,-

162059 FEV26P Extension FLAT ROOF support frame for additional EKSV26P 9.045,-

162060 FBH26P Basic FLAT ROOF support frame for 1 EKSH26P 10.717,-

162061 FEH26P Extension FLAT ROOF support frame for additional EKSH26P 6.992,-

162029-RTX FIXLP Release tool 304,-

162052-RTX GFL 20l ready to use glycol Tmin

= -28°C 3.573,-

Page 44: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

44

▪ Drain back combination tables

▪ Additional items drain back in function of installation

> Daikin solar system

EKSV21P Drain back

# of panels 2 3 4 5

Material On

roof

In

roof

On

roof

In

roof

On

roof

In

roof

On

roof

In

roof

EKSV21P 2 2 3 3 4 4 5 5

FIXVBP 1 1 2 2 3 3 4 4

FIXMP100 2 2 3 3 4 4 5 5

FIXADP

2 0 3 0 4 0 5 0FIXADS

FIXWD

FIXDB

IBV21P 0 1 0 1 0 1 0 1

IEV21P 0 0 0 1 0 2 0 3

EKHWP***B 1 1 1 1 1 1 1 1

EKSRPS3B 1 1 1 1 1 1 1 1

EKRP1HBA 1 1 1 1 1 1 1 1

BSKK 1 1 1 1 1 1 1 1

FLG 1* 1* 1* 1* 1* 1* 1* 1*

TS 1 1 1 1 1 1 1 1

CON15 1 1 1 1 1 1 1 1

EKSRCAP/EKSRCRP 1 0 1 0 1 0 1 0

RCIP 0 1 0 1 0 1 0 1

* : optional (recommended)

EKSV26P Drain back

# of panels 2 3 4 5

Material On

roof

In

roof

Flat

roof

On

roof

In

roof

Flat

roof

On

roof

In

roof

Flat

roof

On

roof

In

roof

Flat

Roof

EKSV26P 2 2 2 3 3 3 4 4 4 5 5 5

FIXVBP 1 1 1 2 2 2 3 3 3 4 4 4

FIXMP130 2 2 2 3 3 3 4 4 4 5 5 5

FIXADP

2 0 0 3 0 0 4 0 0 5 0 0FIXADS

FIXWD

FIXDB

IBV26P 0 1 0 0 1 0 0 1 0 0 1 0

IEV26P 0 0 0 0 1 0 0 2 0 0 3 0

FBV26P 0 0 1 0 0 1 0 0 1 0 0 1

FEV26P 0 0 0 0 0 1 0 0 2 0 0 3

EKHWP***B 1 1 1 1 1 1 1 1 1 1 1 1

EKSRPS3B 1 1 1 1 1 1 1 1 1 1 1 1

EKRP1HBA 1 1 1 1 1 1 1 1 1 1 1 1

BSKK 1 1 1 1 1 1 1 1 1 1 1 1

FLG 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* 1* 1*

TS 1 1 1 1 1 1 1 1 1 1 1 1

CON15 1 1 1 1 1 1 1 1 1 1 1 1

EKSRCAP/EKSRCRP 1 0 0 1 0 0 1 0 0 1 0 0

RCIP 0 1 0 0 1 0 0 1 0 0 1 0

RCFP 0 0 1 0 0 1 0 0 1 0 0 1

* : optional (recommended)

EKSH26P Drain back

# of panels 1 2 3 4 5

Material On

roof

Flat

roof

On

roof

Flat

roof

On

roof

Flat

roof

On

roof

Flat

roof

On

roof

Flat

roof

EKSH21P 1 1 2 2 3 3 4 4 5 5

FIXVBP 0 0 1 1 2 2 3 3 4 4

FIXMP200 1 1 2 2 3 3 4 4 5 5

FIXADP

1 0 2 0 3 0 4 0 5 0FIXADS

FIXWD

FIXDB

FBH26P 0 1 0 1 0 1 0 1 0 1

FEH26P 0 0 0 1 0 2 0 3 0 4

EKHWP***B 1 1 1 1 1 1 1 1 1 1

EKSRPS3B 1 1 1 1 1 1 1 1 1 1

EKRP1HBA 1 1 1 1 1 1 1 1 1 1

BSKK 1 1 1 1 1 1 1 1 1 1

FLG 1* 1* 1* 1* 1* 1* 1* 1* 1* 1*

TS 1 1 1 1 1 1 1 1 1 1

CON15 1 1 1 1 1 1 1 1 1 1

EKSRCAP/EKSRCRP 1 0 1 0 1 0 1 0 1 0

RCFP 0 1 0 1 0 1 0 1 0 1

* : optional (recommended)

Material Description Required quantity

165070 Gravity brakes 1 set per tank heat exchanger adviced if piping from heat exchanger is not making downward bend at the tank

CONX25

Elongation sets Depending on required elongationCONX100

CONX50

CONXV80 Elongation pipe with couplings for inlet 8 m Only required if rooftransit of outlet pipe collector can not be located next to outlet connection of solar collector

CONRVP Connection pipe between solar panel rows Number of rows - 1; Remove 1 FIXVBP per CONRVP

Page 45: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

45

> Daikin solar system

▪ Pressurised combination tables

EKSV21P Pressurised

# of panels 2 3 4

Material On

roof

In

roof

On

roof

In

roof

On

roof

In

roof

EKSV21P 2 2 3 3 4 4

FIXVBP 1 1 2 2 3 3

FIXMP100 2 2 3 3 4 4

FIXADD 6 0 10 0 12 0 standard roof tiles

FIXADP

2 0 3 0 4 0 other roof typesFIXWD

FIXDB

IBV21P 0 1 0 1 0 1

IEV21P 0 0 0 1 0 2

EKHWS / EKHWE 1 1 1 1 1 1

EKSOLHWAV1 1 1 1 1 1 1

EKSRDS1A 1 1 1 1 1 1

164116 1 1 1 1 1 1

EKSR3PA 1 1 1 1 1 1

FLG 1* 1* 1* 1* 1* 1*

CON15P16 1 1 1 1 0 0

CONCP16 1 1 1 1 0 0

CON15P20 0 0 0 0 1 1

CONCP20 0 0 0 0 1 1

MAGS12 1 1 0 0 0 0

MAGS25 0 0 1 1 0 0

MAGS35 0 0 0 0 1 1

EKSRCP 1 1 1 1 1 1

GFL Depending on system volume

* : optional (recommended)

EKSV26P Pressurised

# of panels 1 2 3

Material On

roof

In

roof

Flat

roof

On

roof

In

roof

Flat

roof

On

roof

In

roof

Flat

roof

EKSV26P 1 2 2 2 3 3 3

FIXVBP 0 1 1 1 2 2 2

FIXMP130 1 2 2 2 3 3 3

FIXADD 4 6 10 standard roof tiles

FIXADP

1 2 0 0 3 0 0other roof

typesFIXWD

FIXDB

IBV26P 0 0 1 0 0 1 0

IEV26P 0 0 0 0 0 1 0

FBV26P 0 0 0 1 0 0 1

FEV26P 0 0 0 0 0 0 1

EKHWS / EKHWE 1 1 1 1 1 1 1

EKSOLHWAV1 1 1 1 1 1 1 1

EKSRDS1A 1 1 1 1 1 1 1

164116 1 1 1 1 1 1 1

EKSR3PA 1 1 1 1 1 1 1

FLG 1* 1* 1* 1* 1* 1* 1*

CON15P16 1 1 1 1 1 1 1

CONCP16 1 1 1 1 1 1 1

MAGS12 1 1 1 1 0 0 0

MAGS25 0 0 0 0 1 1 1

EKSRCP 1 1 1 1 1 1 1

GFL Depending on system volume

* : optional (recommended)

EKSH26P Pressurised

# of panels 1 2 3

Material On

roof

Flat

roof

On

roof

Flat

roof

On

roof

Flat

roof

EKSH21P 1 1 2 2 3 3

FIXVBP 0 0 1 1 2 2

FIXMP200 1 1 2 2 3 3

FIXADD 4 0 6 0 10 0 standard roof tiles

FIXADP

1 0 2 0 3 0 other roof typesFIXWD

FIXDB

FBH26P 0 1 0 1 0 1

FEH26P 0 0 0 1 0 2

EKHWS / EKHWE 1 1 1 1 1 1

EKSOLHWAV1 1 1 1 1 1 1

EKSRDS1A 1 1 1 1 1 1

164116 1 1 1 1 1 1

EKSR3PA 1 1 1 1 1 1

FLG 1* 1* 1* 1* 1* 1*

CON15P16 1 1 1 1 1 1

CONCP16 1 1 1 1 1 1

MAGS25 1 1 1 1 1 1

EKSRCP 1 1 1 1 1 1

GFL Depending on system volume

* : optional (recommended)

▪ Additional items pressurised in function of installation

Material Description Required quantity

CONLCP Connection pipe between solar panel rows Number of rows - 1; Remove 1 FIXVBP per CONLCP

CONXP16 Connection between 2 CON15P16 Additional CON15P16 needed

CONXP20 Connection between 2 CON15P20 Additional CON15P20 needed

Page 46: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

46

> Notes

Page 47: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

47

> Commercial terms and conditions

Campus 21, Europaring F12/402 · A-2345 Brunn am Gebirge, Austria

phone +43 2236 32557, fax +43 2236 32557-900, offi [email protected], www.daikin-ce.com

The Daikin Commercial terms and conditions are also available in the internet at http://www.daikin-ce.com

I. GENERAL

Our deliveries and services are exclusively subject to the following terms and conditions of sale and delivery, even

if the customer provides otherwise. The ordering party’s counter-confi rmations in reliance on his commercial

terms and conditions or his terms and conditions of purchase apply only if they are consistent with these terms

and conditions of delivery. Acceptance of the goods is in any event deemed to constitute an acknowledgment of

our terms and conditions of sale and delivery. Any deviating modifi cations and amendments require our express

consent and must be made in writing to be legally valid. Our commercial terms and conditions can be found at

www.daikin-ce.com.

II. OFFER

Our off ers are without engagement and non-binding. Any information about dimensions, weights, technical data,

quantities and delivery times is non-binding.

III. PLACING OF AN ORDER, CHANGE OF THE DELIVERABLE

1 . Orders must be placed in writing (by letter, fax or email). We are deemed to have accepted an order not until

after we have confi rmed in writing or actually executed that order. Any arrangement and agreement reached

verbally and by phone must be confi rmed in writing.

2. We reserve the right to rescind the contract even after having accepted an order if information we have

obtained about the customer’s liquidity in the meantime suggests that the customer will not be able to pay for

the entire or for part of the order.

3. Having accepted an order, we also reserve the right to change and improve the service or deliverable, e.g. in

respect of its type and design, to the extent the customer can be reasonably expected to accept such changes

and improvements in consideration of our interests (e.g. delivery of an equivalent or more sophisticated

device). Such changes and improvements are deemed approved in advance.

4. The customer’s cancellation or change of an entire or of part of an order requires our written consent

and entitles us to charge the customer - in addition to the services already provided and costs accrued

- a (cancellation) fee equal to 20  % of the order value and at least €  250. For certain product

groups (e.g. multiple scroll, screw chiller), separate cancellation rules apply which can be found at

www.daikin-ce.com.

IV. PRICES AND TERMS OF PAYMENT

1. Prices are based on the price list, as amended from time to time, which is usually issued once a year. We reserve

the right to change prices also during a year.

2. Prices are understood to be net prices without any taxes, duties or charges in the quoted currency, including

packaging, ex our forwarding warehouse, unless otherwise indicated. We will not take back packaging and

packing material.

3. We will not accept any objections to invoices which are received more than two weeks after receipt of an

invoice. Unless otherwise indicated, invoices are due net 30 days from the invoice date; the payment date is

the date on which a payment is received by us. In case of late payment, we will charge default interest at a rate

of 12% p.a. In case of default, we may also demand all costs related to the collection of our claim, including,

without limitation, dunning and collection charges.

4. If payment by instalments has been agreed, the maturity date will be accelerated if the customer is in default

in respect of only one instalment.

5. We may make deliveries dependent on advance payment.

6. The customer may not withhold or set off payments in reliance on warranty or other claims.

V. DELIVERY TIME

1. Indicated delivery times are non-binding and reference times only, although we endeavour to meet indicated

deadlines. The customer has no right to insist on compliance with a certain delivery time. As a consequence,

delays in delivery will not entail any claims for damages and do not entitle the customer to rescind the contract.

The same holds true if delivery deadlines are not met due to force majeure, strike or other events outside our

control.

2. We will not accept penalty claims asserted by the customer under any circumstances.

3. Partial deliveries are permitted.

4. If the ordering party is in arrears on an earlier delivery, Daikin may withhold deliveries pending payment of the

earlier delivery and is not required to pay to the ordering party any damages in this respect.

VI. ACCEPTANCE OF DELIVERIES, TRANSFER OF RISK, DELAYED ACCEPTANCE

1. Unless otherwise agreed, deliveries are made CIP (Incoterms 2010) to the named destination

2. In principle, delivery CIP covers only minimum transport insurance. Additional transport insurance will be

purchased only if explicitly requested by customer and subject to a separate agreement and at the customer’s

cost and expense.

3. The customer must immediately check deliverables received by him or directly by his customers for any

transport damage, and he must record any damage to the packaging or the device in the delivery note and

shall refuse delivery towards the forwarding agent. If the customer fi nds out only later that goods are damaged,

the customer shall report any such damage to us, immediately, in no case later than three working days after

delivery; otherwise, any insurance claim may expire.

4. If the customer accepts goods with delay, we - notwithstanding our other rights - may charge the goods as

delivered or may otherwise dispose of them @ setting a time limit. If we otherwise dispose of the goods, the

delivery time will recommence on the day we receive the customer’s written request calling for delivery of

the goods.

5. We may charge the customer for any costs incurred due to late acceptance, including, without limitation, any

storage costs.

VII. RESERVATION OF TITLE

1. We will retain title to goods delivered pending full payment of all claims arising from our business relationship

with the customer, even if the purchase price for specifi cally designated claims was paid. If our conditional

goods are processed, we will acquire title to the new item without consideration. If the goods delivered by us

are mixed, processed or combined with other items, the customer hereby assigns to us in proportion of the

value of our invoices an ownership or co-ownership right of the combined or new item, both in respect of the

interim and the fi nal products.

2. The customer may resell goods delivered by us and the items created by processing, mixing or combining

these only in the ordinary course of business. The customer hereby assigns to us any claims arising from such

resale or from any other legal ground toward third parties, including, ancillary rights, in order to secure our -

future - claims that may arise from our business relationship. The customer must record the assignment of these

claims in his books not later than when the goods are resold.

3. Before having paid the purchase price of an item, the customer may resell that item only if he simultaneously

informs the second buyer (end customer) that the resale proceeds have previously been assigned.

4. The customer may collect the assigned claims as long as he fulfi ls his payment obligations towards us according

to the terms of the contract. The customer may not otherwise dispose of the conditional goods (e.g.: transfer

of property by way of security, pledging).

5. The customer must immediately inform us of any attachment or other impairment of the conditional goods

and/or the assigned claims and explain to the third party that we have retained title to those goods. Any related

cost will be borne by the customer.

VIII. WARRANTY AND LIABILITY

A. Unless otherwise agreed and to the exclusion of any further claims, we are liable for any defects and the absence

of warranted qualities as follows:

1. Unless otherwise indicated below, the warranty period is 36 months of the delivery date (delivery to the

forwarding agent). This does not aff ect the applicability of Section 924 of the Austrian Civil Code.

2. The customer may assert a warranty claim only if the equipment is both installed and put into operation

by Daikin or a company trained by Daikin according to the Daikin installation instructions and regularly

maintained according to the Daikin service notes. Refrigerating machines featuring screw-type compressors

include a 12-month warranty claim only if the machine was put into operation by Daikin itself. In case of

products designated “J&E Hall International for Daikin” the customer may assert an 18-month warranty claim.

For “Rotex” branded products generally a 24-month warranty period is valid except for following variations: 10

years for underfl oor heating pipes and system plates, VA-piping and variosafe oil storage tanks. 5 years for solar

panels, variosystem and highcube oil tanks and variocistern rainwater tanks. 3 years for HPSU heat pump solar

unit and hot water storage tanks HYC, SCS and SC.

3. In a warranty event, we undertake, at our election, to replace or repair the defective goods or components. The

customer may not assert other warranty or guarantee claims whatsoever. Labour cost, travel times or other

costs will not be reimbursed.

4. No warranty and/or liability is accepted, unless the customer reports visible defects by giving written notice

within 3 working days of delivery and other defects without delay after these have been discovered.

5. In addition to paragraphs 2 and 4, no warranty and/or liability is accepted for defects that have been caused by

inadequate or improper use or treatment, failure to observe operating conditions or maintenance guideless,

excessive use or inadequate operating facilities or substitute materials.

6. Unless we are granted the required time and opportunity to take all necessary warranty measures, we are

released from any warranty claims and damages. If the customer continues to use defective goods, we warrant

and/or are liable only for the original defect. We will not reimburse any cost of repairs which are carried out

without our express prior consent. We disclaim any liability for the consequences of such repairs.

7. The warranty period for spare parts and other improvements is 6 months of delivery (delivery to the forwarding

agent).

8. If a defect is remedied, the warranty period will not recommence for the replaced or repaired components.

9. We may refuse to remedy defects as long as the customer is in default with his payment obligations. The

customer has no right to withhold payments, even if he gave justifi ed notice of defects.

10. If third-party products are delivered and installed, warranty is restricted to assigning the warranty claims we

may assert against the supplier of the third-party product. The customer may not assert any other warranty

claims and may particularly not claim a price reduction.

B. We are liable for damage only if we demonstrably acted with intent or gross negligence. We disclaim any

liability for slight negligence. We are particularly not liable for consequential damage (e.g. idle times due to wrong

deliveries) and fi nancial loss, lost profi t, unachieved savings, loss of interest and any damage suff ered from third-

party claims against the customer, unless the foregoing is attributable to our intent or gross negligence. If damage

is attributable to the defective condition of goods delivered by us, we are liable only to the extent the producer

or upstream supplier is liable to us. Our liability does in any case not exceed the invoice value of the incriminated

goods.

IX. RETURNED GOODS

1. Goods can be returned and exchanged only upon our express and written consent. We accept returned goods

only with a minimum net value of € 100,00 and a maximum net value of € 50.000,00 and only provided that

those goods are not damaged, have not been used, are in original packaging and are fi t for resale. In particular,

returns of already installed units (including chillers) and returns of any made to order units as well as spare

parts are not permitted.

2. The customer shall complete the “Request for Goods Return”-form (available at the DENV Extranet,

http:\\extranet.daikineurope.com) and send it to us to the fax number or email address provided by us within

10 calendar days after delivery, otherwise we will not accept the return.

3. Goods must be returned freight paid at the risk of customer to the destination indicated by us.

4. In every case of a return, a maximum of 80% of the net price charged by us to the customer will

be credited. All standard returns will be subject to a restocking / administration charge of 20 % of the net price.

5. All returns will be inspected by us. If goods are returned wrongly (i.e. not in compliance with paragraph 1.

above), we may refuse the returns and have them returned back to the customer at the customer’s risk and

costs. Alternatively, we may charge a higher restocking / administration fee than the above mentioned 20%.

6. Any credit notes whatsoever will exclusively be set off against future deliveries.

X. PLACE OF JURISDICTION, APPLICABLE LAW

1. All disputes arising from or in connection with this Agreement shall be exclusively referred to the courts in

Vienna.

2. All contracts concluded by us and all disputes arising in connection with those contracts shall be governed

by and construed in accordance with Austrian law without giving eff ect to its confl ict of law rules and the UN

Sales Convention.

XI. SEVERABILITY

Should any term of these commercial terms and conditions or of the contract concluded between us and the

customer be invalid or ineff ective, this shall not aff ect the remaining terms hereof or thereof. Invalid terms shall be

replaced by lawful terms which closest refl ect the parties’ intent.

Page 48: Heating PL 2015 CZE - Daikin HCE Program€¦ · Daikin inverter compressors with high modulation range provide: – Higher compressor effi ciency in partial load operation. ... (ERLQ-C

The present publication is drawn up by way of information only and does not

constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe

HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has

compiled the content of this leaflet to the best of its knowledge. No express

or implied warranty is given for the completeness, accuracy, reliability or fitness

for particular purpose of its content and the products and services presented

therein. Specifications are subject to change without prior notice. Daikin Europe

N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any

direct or indirect damage, in the broadest sense, arising from or related to the

use and/or interpretation of this leaflet. All content is copyrighted by Daikin

Europe N.V.

DA

CE

He

atin

g P

rice

list

20

15

Ve

rsio

n 1

• C

op

yrig

ht

Dai

kin

We

re

serv

e t

he

rig

ht

for

pri

nti

ng

err

ors

an

d m

od

el c

han

ge

s.

DAIKIN AIRCONDITIONING CENTRAL EUROPE HandelsgmbH

campus 21, Europaring F12/402, A – 2345 Brunn am Gebirge

Tel.: +43 / 22 36 / 3 25 57, Fax: +43 / 22 36 / 3 25 57-900

e-mail: offi [email protected], www.daikin-ce.com

Daikin Europe N.V. participates in the Eurovent

Certifi cation programme for Air conditioners (AC),

Liquid Chilling Packages (LCP), Air handling units

(AHU) and Fan coil units (FCU), Check ongoing validity

of certifi cate online: www.eurovent-certifi cation.com

or using: www.certifl ash.com

Daikin Products are distributed by:

COP in heat pump operation: 5.04

Heating and domestic hot

water

Most economical mode to operate

Up to 35% effi ciency increase compared to condensing boiler

Gas condensing boiler of33 kW

Hybrid technology

The naturalcombination

Rotex hybrid heat pump