Top Banner

of 82

Heaters Nice Presetation

Oct 16, 2015

Download

Documents

Varun Gupta

H
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript

PRESENTATION ON CRUDE HEATER

PRESENTATION ONCRUDE HEATERBYGAURAV KANODIA

What is a Heater?A heater is a heat transfer equipment where heat of combustion of fuel oil/fuel gas is used to increase the temperature of the desired fluid.

On the basis of Draft ( Natural, Forced, Induced and Balanced Draft)On the basis of Structural Configuration ( Cylindrical, Cabin, Multi cell)On the basis of Radiant Tube Configuration ( Vertical, Horizontal, Helical and Wicket Type)On the Basis of Burner position ( Up fired, Down fired and Wall fired)Classification of Heaters

CDU HEATER CONFIGURATIONAT BORLBalanced Draft, Twin Cell, Cabin Type, Horizontal Radiant Tubes and Up fired.API 560 : Fired Heater for RefineryAPI 530 : Heater Tube thickness in RefineryAPI RP 550 : Installation of Instruments and Control System for Fired heater and Steam GenerationEA 7301 : Guidelines for NoiseDesign of Heater Heat Distribution in Radiant SectionFlame Radiation 17%Hot Gas Radiation (Combustion Products) 32%Convection from Flue Gases 7%Refractory Reflection 14% Mirror Effects Total 70%Convection Section 15%Losses 15%

CDU Heater

Heat Duty : 43.84 MillionKcal/hr. Fluid Handled : Crude@18000MT/D.Inlet Crude Temp. : 310 COutlet Crude Temp. : 365 CFuel Used : Fuel Gas/Fuel Oil/ Hot well gases

Crude IN OUT Liquid (Kg/hr) 750000 420553 HC Vapour (Kg/hr) 329447 Operating pressure 19.73 3.73 (kg/cm2 g) Operating temperature 310 365 (Deg.C)

Fluid HandledMP Steam IN OUT Flow (kg/hr) 13150 13150 Pressure(Kg/cm2 g) 15.5 14.5 Temperature (Deg. C) 209 315 Topmost part of the Convective Section 100 mm thick Castable typeEntrance of the Convective Section 100 mm thick Castable type+50 mm thick C.Fibre board with 8mm dia SS316L lugs+0.1mm thick SS316 foil between Castable and board

INSULATION Arch Section 125 mm thick C.Fibre module+25mm C.Fibre blanket with SS 316L studs+0.1 mm SS316 foil between blanket and fibre module.Radiant Section 100 mm thick C.Fibre module +25mm C.Fibre blanket with SS316L studs+0.1 mm SS316 foil between blanket and C.Fibre module

Tube Configuration

No. of Passes : 8No. of Tubes in Convective Section : 96No. of tubes in radiant Section : 128MOC of Tubes : 5Cr,0.5MoO.D. of Tubes : 168.3 mmThickness of tubes : 7.11 mm I.D. of Tubes : 154.08 mm

It is the negative air pressure generated bythe buoyancy of hot gases generated insidethe furnace. Measured At : Firebox FloorBelow the Convective SectionAt the Duct Inlet DRAFT

Fuel Gas (mol %) Hydrogen 48.72 N Butane 2.33 H2S 0.015 C5+ 1.84 CO2 0.08 NH3 0.01 Water 0.55 CH4 27.10 C2H6 13.86 C2H4 1.03 C3H8 3.48 C3H6 0.29 i-Butane 0.68 Butenes 0.01Pressure at burner (Kg/cm2 g) 1.5 Temperature at burner (Deg.C) 40 Heating value (Kcal/kg) 11590

Ejector off gas from VDU Flow (kg/hr) 2590 Pressure(Kg/cm2 a) 1.1 Temperature (Deg.C) 45

Fuel Oil Sulphur Content 1%( wt.)Nitrogen 834 ( wt ppm)Ni