Specifications and dimensions are for reference only and are subject to change without notice. Optional equipment may affect dimensions and weight. IDF-14 D 2,800,000 BTU/HR 14,000 CFM INDIRECT FIRED IDF-14 D HEATER SPECIFICATIONS Burner capacity Airflow Firing Fuel Gas Pressure Power Full Load Air Discharge 2,800,000 BTU/HR 14,000 CFM Indirect Fired, Forced Draft, Lo-Hi-Lo #1 & #2 Diesel Fuel, Natural Gas or Vapor Propane 2 PSI Minimum, Specify Available Gas and Pressure When Ordering Discharge Temp. Weight Dimensions 208-240 Vac / 3 Phase / 60 Hz 480 Vac / 3 Phase / 60 Hz 45A @ 240V / 3 Phase 23A @ 480V / 3 Phase 28” Diameter 200°F @ 0°F Ambient 9,400 Lbs. dry (varies based on configuration) 192” L x 95” W x 96” H without stack Models DO – Oil Burner, DG – Gas Burner and DGO – Duel Fuel, Gas and Oil C US C US STANDARD EQUIPMENT Heavy Duty Welded Construction Powerful Backward Inclined Blower Artic Wiring Designed for -80°F Service Panel with Indicator Lights for Heater Functions Oil Field Skid with Fork Pockets Stainless Steel Fire Tube Heated Walk-in Burner/Blower Control Room with Lights Fireye Flame Safety Control with Purge Cycle Discharge Temperature Control with High Temp Shutdown Air Proving Switch Safety Disconnect Switch Heavy Duty Fuel Filter (Oil Models) 50’ Remote Thermostat OPTIONS • Duel Fuel (Gas and Oil) or Heavy Oil Burner Side Mounted Fuel Tank • Vaporizer • High Pressure Gas Hose • Rigid or Flexible Ducting • Insulated and Non-Insulated Ducting • Specialty Paints and Coatings • Explosion Proof Thermostat • Various Voltages and Frequencies • Air Circulation Fans from 8,000 to 26,000 CFM 28"
2

HEATER SPECIFICATIONS - Tioga Air Heaters

May 16, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: HEATER SPECIFICATIONS - Tioga Air Heaters

Specifications and dimensions are for reference only and are subject to change without notice.Optional equipment may affect dimensions and weight.

IDF-14 D2,800,000 BTU/HR

14,000 CFM INDIRECT FIRED

IDF-14 D

HEATER SPECIFICATIONS

Burner capacity

Airflow

Firing

Fuel

Gas Pressure

Power

Full Load

Air Discharge

2,800,000 BTU/HR14,000 CFM Indirect Fired, Forced Draft, Lo-Hi-Lo #1 & #2 Diesel Fuel, Natural Gas or Vapor Propane2 PSI Minimum, Specify Available Gas and Pressure When Ordering

Discharge Temp.

Weight

Dimensions

208-240 Vac / 3 Phase / 60 Hz480 Vac / 3 Phase / 60 Hz45A @ 240V / 3 Phase23A @ 480V / 3 Phase28” Diameter200°F @ 0°F Ambient9,400 Lbs. dry (varies based on configuration)192” L x 95” W x 96” H without stack

Models DO – Oil Burner, DG – Gas Burner and DGO – Duel Fuel, Gas and Oil

C USC US

C USC US

STANDARD EQUIPMENT

• Heavy Duty Welded Construction• Powerful Backward Inclined Blower• Artic Wiring Designed for -80°F• Service Panel with Indicator Lights for Heater Functions• Oil Field Skid with Fork Pockets• Stainless Steel Fire Tube• Heated Walk-in Burner/Blower Control Room with Lights• Fireye Flame Safety Control with Purge Cycle• Discharge Temperature Control with High Temp Shutdown• Air Proving Switch• Safety Disconnect Switch• Heavy Duty Fuel Filter (Oil Models)• 50’ Remote Thermostat

OPTIONS• Duel Fuel (Gas and Oil) or Heavy Oil Burner• Side Mounted Fuel Tank• Vaporizer• High Pressure Gas Hose• Rigid or Flexible Ducting• Insulated and Non-Insulated Ducting• Specialty Paints and Coatings• Explosion Proof Thermostat• Various Voltages and Frequencies• Air Circulation Fans from 8,000 to 26,000 CFM

28"

Page 2: HEATER SPECIFICATIONS - Tioga Air Heaters

Typical uses for The TIOGA Air Heater

Powerful, efficient, and incredibly reliable...

IDF-14 D

Minneapolis, MN(763) 525-4000

Fax (763) 525-9796

Casper, WY(307) 237-3473

Fax (307) 266-5016

Cleveland, OH(740) 756-7980

Fax (740) 756-7981

Benefits• Extremely Rugged Design• Ability to Use Cold Outside Air or Recirculate• Low Maintenance• Designed to Operate at -40°F• Increased Air Circulation• Reduced Moisture Problems• Clean, Safe and Reliable Heat• Rapidly Heat Large Volumes of Air• Pressurize the Building

Additional Services Offered

Tioga designs, manufacturers and refurbishes rentalunits to like-new condition after every use.

Always check local codes and ordinances for permitted uses. CSA ratings may vary, contact office for current CSA information.

IDF Series Air Heaters are ideal for

IDF Series Air Heaters offer

(800) 218-4642 • www.TiogaAirHeaters.com • Email: [email protected]

Our heating specialists will assist you selecting the exact airflow and burner capacity required for your heating application.

• Extreme Environments• Oil & Gas Fields• Pipe Lines• Construction• Mining• Paint & Coatings• Ground Support

• Power Plants• Refineries• Remediation• Processing Facilities• Air Distribution• Humidity Control• Emergency Standby

• 100% Uncontaminated Fresh Air• No Combustion Bi-products in the Air Stream• No Exposed Flame• All Welded Construction• Powerful Backward Inclined Blower• CSA Approved For US and Canada

• Heater recommendations Estimated fuel consumption

• 24/7 phone service support• Duct work design