Top Banner
HEART RATE MEASUREMENT FROM FINGERTIP
13

Heart Rate Measurement From Fingertip2003

Apr 13, 2015

Download

Documents

Samarpit Arya

heart beat measurement
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Heart Rate Measurement From Fingertip2003

HEART RATE MEASUREMENT FROM FINGERTIP

Page 2: Heart Rate Measurement From Fingertip2003

INTRODUCTION ► Heart rate measurement

indicates the soundness of the human cardiovascular system.

► This project demonstrates a technique to measure the heart rate by sensing the change in blood volume in a finger artery while the heart is pumping the blood.

Page 3: Heart Rate Measurement From Fingertip2003

BASIC BLOCK DIAGRAM

Page 4: Heart Rate Measurement From Fingertip2003

SYNOPSIS

► Heart rate measurement system that uses optical sensors to measure the alteration in blood volume at fingertip with each heart beat.

► sensor unit consists of an infrared light-emitting-diode (IR LED) and a photodiode.

► IR diode transmits an infrared light into the fingertip and the photodiode senses the portion of the light that is reflected back.

Page 5: Heart Rate Measurement From Fingertip2003

► Intensity of reflected light depends upon the blood volume inside the fingertip.

► So, each heart beat slightly alters the amount of reflected infrared light that can be detected by the photodiode & with a signal conditioning this little change in the amplitude of the reflected light can be converted into a pulse which can counted by MC.

Page 6: Heart Rate Measurement From Fingertip2003

SCHEMATIC

► The schematic consist of two stages:-

1. Input sensing and conditioning circuit.

2. MCU circuit used for counting of pulses & display of output.

Page 7: Heart Rate Measurement From Fingertip2003

INPUT SENSING & CONDITIONING CIRCUIT

Page 8: Heart Rate Measurement From Fingertip2003

MCU AND OUTPUT DISPLAY

Page 9: Heart Rate Measurement From Fingertip2003

MAJOR COMPONENTS USED

► Pic16f628a (MCU):

1. By microchip technology.

2. Smaller instruction set as compared to other MCUs.(RISC based)

3. Low cost with high clock speed.

4. Provide wide range of interfacing.

Page 10: Heart Rate Measurement From Fingertip2003

MAJOR COMPONENTS USED

► MCP602 transistor:

1. Dual package opamp from microchip.

2. Operating voltage-2.7-6V

3. Need Single supply voltage

4. Used in input signal amplification.

► Photodiode and IR diode as sensor unit

► 3 digit 7-segment display

Page 11: Heart Rate Measurement From Fingertip2003

APPLICATIONS AND SIGNIFICANCE OF THE PROJECT

► This project aim at learning the compact and advanced medical technology used in measuring heart rate.

► The project has been widely applied in medical technology , even in heart rate monitoring applications designed for mobile phones.

Page 12: Heart Rate Measurement From Fingertip2003

ESTIMATED COST & SCHEDULING ANALYSIS

► The complete project setup is costing in the range of Rs. 800 to 1000/- *.

► The entire project is scheduled in two phases:-

1. Learning of embedded C programming used.

2. Hardware implementation: Assembling the entire setup on PCB or PCB prototype board.

*(may subject to change due to faulty component of wear and tear).

Page 13: Heart Rate Measurement From Fingertip2003

THANK YOUSamarpit arya(07710102809)

Abhinav choudhary(07610102809)