Top Banner
USE OF HEADED REINFORCEMENT IN BEAM - COLUMN JOINTS John W. Wallace, Ph.D., P.E. Associate Professor, UCLA Scott W. McConnell, M.S., P.E. Structural Engineer, Schoor-DePalma, NJ National Science Foundation Headed Reinforcement Corporation ERICO Incorporation
24

Headed Reinforcement

Apr 04, 2015

Download

Documents

Habibi Mehedi
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Headed Reinforcement

USE OF HEADED REINFORCEMENT IN BEAM - COLUMN JOINTS

John W. Wallace, Ph.D., P.E.Associate Professor, UCLA

Scott W. McConnell, M.S., P.E.Structural Engineer, Schoor-DePalma, NJ

National Science Foundation

Headed Reinforcement Corporation

ERICO Incorporation

Page 2: Headed Reinforcement

HEADEDREINFORCEMENT ?

Plate Anchor Rectangular/Round Threaded/Friction Weld Area = 5 to 10 Bar Area Beam-Column Joints Standard Hooks Ease of Fabrication & Placement

Page 3: Headed Reinforcement

WHY HEADED REINFORCEMENT ?Congestion/Fabrication/Placement

Page 4: Headed Reinforcement

AVAILABLE INFORMATIONAnchorage/Beam-Column Joints UCLA & Clarkson University

Wallace, McConnell, Gupta Reports/ACI Papers (1994, 1997, 1998)Also Yu (2001)

University of Texas, AustinJirsa, Devries, BashandyPh.D. Dissertations (1996), ACI Paper (1999)

University of KansasMcCabe, Wright, Wu (Reports, 1997)

Page 5: Headed Reinforcement

PROJECT OVERVIEW

EXTERIOR ROOF& CORNER JOINTS

EXTERIOR INTER-STORY JOINTS

Page 6: Headed Reinforcement

HYDRAULIC ACTUATOR

LOAD CELL

CLEVIS

52"

HEAVY LINK

SPECIMENLVDT FOR DISPL.CONTROL

RIGID REFERENCEFRAME

36"

TIE DOWN REACTION WALL

STRONG FLOOR

TEST SETUPExterior Roof Connections

Page 7: Headed Reinforcement

SPECIMEN DETAILSExterior Roof Connections

#5 GR60 US REBAR(16 mm)

#3 STIRRUP(9.5 mm)

14.5"

9.5"0.75"

BEAM CROSS SECTION

11" x 16"280 mm x 406 mm

COLUMN CROSS SECTION

16" x 16"406 mm x 406 mm

#6 (20mm)

14.5"

14.5"0.75"

#3 HOOP & CROSSTIES

(368 mm)(241 mm)

Page 8: Headed Reinforcement

DESIGN REQUIREMENTSExterior Roof Connections

Strong Column - Weak Beam (352-01)

Joint Confinement Reinforcement (352-01)

Joint Shear Stress Limits (352-91)

2 (1.1 Test).1 / beamcolumn MM

(test) 51.1/

f/f )1/(3.0

',,

y'c

dreqshprovidedsh

chgcsh

AA

AAshA

0.1 to 5.0 /

kips 140 to 75P ) 60)(25.1)( (

kips 140)"5.13)("16((psi) 4000 )12)(85.0(2

nu

beamsu

n

VV

ksiinAV

V

Page 9: Headed Reinforcement

DESIGN REQUIREMENTSExterior Roof Connections

Anchorage Requirements– Tension (318 Eq. 21-5, 352-91)

– Compression (318 S12.3)

1.55 to 25.122)/14.23 to (18 /

23.14(psi) f/ 900 (0.75)

(psi) f/ 1200 (psi) f/f 02.0'c

'c

'cy

dprovided

bddbd

dbdb

ll

ddll

ddl

1.5 to 23.16.14/22) to 18( /

14.6 (psi) f/925 (psi) f 65/ f 'c

'c

bbdhprovided

bbbydh

ddll

dddl

Page 10: Headed Reinforcement

LOAD HISTORYExterior Roof/Inter-Story Connections

0 200 400 600 800C o u n ter N u m b er

-6

-4

-2

0

2

4

6

Dri

ft L

evel

(%

)

BC EJ -1

Page 11: Headed Reinforcement

Specimen DamageExterior Roof Connections

KJ16 - Top Bar Pull-out

Page 12: Headed Reinforcement

REINFORCING DETAILSExterior Roof Connections

Top View Side View

Restraint Bars Restraint Bars

Page 13: Headed Reinforcement

Moment-Rotation ResponseExterior Roof Connections

-0 .0 6 -0 .0 4 -0 .0 2 0 .0 0 0 .0 2 0 .0 4 0 .0 6

S p ec im en R o ta tio n

-2 5 0 0

-2 0 0 0

-1 5 0 0

-1 0 0 0

-5 0 0

0

5 0 0

1 0 0 0

1 5 0 0

2 0 0 0M

omen

t (in

-kip

s)

-2 5 0

-2 0 0

-1 5 0

-1 0 0

-5 0

0

5 0

1 0 0

1 5 0

2 0 0

Mom

ent (

kN-m

)

K n ee Jo in t # 1 7

4 .0 % 3 .0 %

2 .0 %

1 .5 %

1 .0 %

M n = 1 5 0 8 in -k ip s (P = 4 9 .5 k ip s)

C lo s in g

O p en in g

M n = 1 0 1 1 in -k ip s (P = -3 3 k ip s)

6 .0 %

0 .5 %

Page 14: Headed Reinforcement

MEASURED REBAR STRAINSBeam Top Bars Within the Joint

-2000

0

2000

4000

6000

MIC

RO

ST

RA

IN TB1-FACE

TB1-MID

1.0% 2.0% 4.0%

1.0% 2.0% 4.0%

0 100 200 300 400 500DATA POINT

-2000

0

2000

4000

6000

MIC

RO

ST

RA

IN TB2-FACE

TB2-END

Page 15: Headed Reinforcement

TEST SETUPExterior Inter-Story Connections

12.75 ft (3.89 m)

10 ft(3.05m)

Page 16: Headed Reinforcement

SPECIMEN GEOMETRYExterior Inter-Story Connections

BEAM CROSS SECTION

18" x 24"457 mm x 610 mm

COLUMN CROSS SECTION

18" x 18"457 mm x 457 mm

Page 17: Headed Reinforcement

DESIGN REQUIREMENTSExterior Inter-Story Connections

Strong Column - Weak Beam (352-01)

Joint Confinement Reinforcement (352-01)

Joint Shear Stress Limits (352-91)

2 (1.7 Test).1 / beamcolumn MM

(test) 17.1/

f/f )1/(3.0

',,

y'c

dreqshprovidedsh

chgcsh

AA

AAshA

80.0/

kips 207 ) 60)(25.1)( 79.04(

kips 260)"18)("18((psi) 4000 )15)(85.0(2

nu

columnu

n

VV

VksiinxV

V

Page 18: Headed Reinforcement

DESIGN REQUIREMENTSExterior Inter-Story Connections

Anchorage Requirements– Tension (318 Eq. 21-5, 352-91)

– Compression (318 S12.3)

352)per (0.82 9.06.14/13 /

14.6 (psi) f/925 (psi) f 65/ f 'c

'c

bbdhprovided

bbbydh

ddll

dddl

0.9113/14.23 /

23.14(psi) f/ 900 (0.75)

(psi) f/ 1200 (psi) f/f 02.0'c

'c

'cy

dprovided

bddbd

dbdb

ll

ddll

ddl

Page 19: Headed Reinforcement

Beam End RotationExterior Interstory Connections

BCEJ1 - Drift Level 6%

Potentiometer

Potentiometer

Page 20: Headed Reinforcement

MOMENT-ROTATIONExterior Inter-Story Connections

-0.06 -0.04 -0.02 0.00 0.02 0.04 0.06JOINT ROTATION 24" FROM THE COLUMN FACE

-6000

-4000

-2000

0

2000

4000

6000

MO

ME

NT

(ki

p-i

n)

6 %

4 %

2 %

3 beam bars in tension

4 beam bars in tension

M n= 2860

M n= 3760

Page 21: Headed Reinforcement

Specimen DamageExterior Interstory Connections

BCEJ1 - Drift Level 6% Bottom Bar Push-Out @ 6%

Page 22: Headed Reinforcement

Compression Bar Push-OutExterior Inter-Story Connections

Beam Moment Capacity Compression Steel Slight Pushout Occurs Redistribution From Steel to Concrete Minor Reduction in Beam Moment Capacity Note - Compression ld Satisfied by Checking Tension ld

Page 23: Headed Reinforcement

Summary ObservationsHeaded Bars in Beam-Column Joints

Required Embedment Length Kansas Study: ld = 0.60 ldh Texas Study: ld = (0.60 - 0.70) ldh UCLA/Clarkson Large-Scale Study: ld = 0.82 ldh Other Design Requirements Flexural Strength Ratio: Mcolumn /Mbeam > 1.2 Joint Shear Emdedded Bars Must Be Shoved To Back of Joint Practical Recommendation for Emdedment ld = 0.75 ldh

Page 24: Headed Reinforcement

CONCLUSIONSBeam-Column Joint Tests

– Six Specimens (3 Exterior, 3 Roof)– Small Cover/Need for Transverse Steel– Push-Out of Compression Bars

ACI Committee 352 Draft Report– Modified to Allow Use of Headed Bars

Research Needs - Cyclic Loading– Cover/Transverse Reinforcement– Multiple Layers of Reinforcement