ISO 9001 Manufacturer pressure Specification Sheet SS-HPC400 Pressure ranges HPC400-2C Vacuum to 2 bar / 30 psi HPC400-7C Vacuum to 7 bar / 100 psi HPC400-20C Vacuum to 20 bar / 290 psi Transmitter loop features Transmitter loop measurement, 24 volt DC loop supply and HART® resistor. Easy pressure switch test Opening and closing pressures are automati- cally recorded and deadband is calculated. All is presented in a large graphical display. Useful set of features The HPC400 offers a selection of useful features: voltage measurement, high speed minimum/maximum hold, 5 user specified setups, high or low resolution, and damped readout for fluctuating pressures. Ready-to-use systems The HPC400 is available as a complete system or as an independent instrument. The systems are ready for use, complete with calibration pump, hose, fittings and a convenient hard case to store the complete system. The HPC400 series is a true calibrator, a field instrument designed for easy and reliable check and calibration of pressure. Use the HPC400 series in process control applications such as verification or calibration of pressure gauges, transducers, transmitters, pressure switches, and safety valves. The HPC400 series is recognized for its high quality and carefully select- ed time-saving features making calibration tasks easy to perform. All rel- evant information is shown in the large multi information display at once, such as: 15 different pressure units, transmitter mA reading, min/max recording, peak reading, and semiautomatic pressure switch test find- ing the closing, opening and hysteresis pressure (deadband), and 5 user specified setups for frequent measurement/calibration jobs. Maintenance of the instrument is easy. Recalibration of the unit can be performed locally with an accurate pressure reference: No need to send the unit back to the manufacturer for recalibration. For all systems, pump and calibrator are separate so replacement of the pump does not require return of the complete system for repair. The HPC can be delivered as an individual calibrator or as a complete calibration system ready for use in a carrying case, including pump, hose, connectors, battery, test leads, user manual, and traceable calibra- tion certificate. Handheld Pressure Calibrator Model HPC400 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transmitter loop features Transmitterloopmeasurement,24voltDCloopsupplyandHART®resistor.
Easy pressure switch test Openingandclosingpressuresareautomati-callyrecordedanddeadbandiscalculated.Allispresentedinalargegraphicaldisplay.
Useful set of features TheHPC400offersaselectionofusefulfeatures:voltagemeasurement,highspeedminimum/maximumhold,5userspecifiedsetups,highorlowresolution,anddampedreadoutforfluctuatingpressures. Ready-to-use systems TheHPC400isavailableasacompletesystemorasanindependentinstrument.Thesystemsarereadyforuse,completewithcalibrationpump,hose,fittingsandaconvenienthardcasetostorethecompletesystem.
Useful set of featuresPerformsemi-automaticpressureswitchtests.switchinHARTresistororothercalibrationtasks,assistedbytheoutstandingfunctionsandfeaturesoftheHPC400.
ON / OFFAutoshut-offtoexpandbatterylifetime(userprogram-mable).
bar........................................................vacuumto2,7&20psi.......................................... vacuumto15,30,100&290 Engineering units (built-in)
HPC400, System A • AXX/0 to 2 bar (0 to 30 psi) • AHX/0 to 20 bar (0 to 290 psi)ThissystemincludestheHPCcalibra-tortogetherwithonepneumatichandpump:T-960andT-970,dependingonthechosenpressurerange.SystemAisaneasy-to-usesinglehandoperatedcalibrationsystem.Noneedforaflatsurfacetooperatethesystem-justholditinyourhand.
TheHPCcalibratorsusedinSystemAaredeliveredcali-bratedinbothpressureandvacuum.T-960 and T-970 pumps for system AModelT-960pneumaticpressurepumpfeaturesanextendedrangevolumeadjusterforprecisecontrolofthepumppressureandacomfortablepistolgriphandle.
ModelT-970pneumaticpressurepumpissimilartotheT-960,butgeneratespressuresupto20bar(290psi).Pressurerange,T-960.....................0to2bar/0to30psiPressurerange,T-970..................0to20bar/0to290psiType..................................................................... PneumaticTestmedium.....................................................................AirOperation.................................................................. Scissor“O”-rings..................................................................Buna-NWettedparts..........Aluminum,brass,stainlesssteel,nylon,NylatronGSConnectiontotestobject..................Hose0.6m/24inwith1/4”BSPandNPTfemaleterminationsSize................................ 21.6x12.1x6.2cm/8.5x4.8x2.4inWeight............................................................1.4kg/3.0lbIncluded with System A delivery•HPCstandarddelivery(seepage5)•HandpumpT-960orT-970witha0.6m/24inhosewith1/4”BSPandNPTfemaleterminations•3/8”BSPfemaleadapterwith1/4”BSPandNPTfemaleterminations•QuickconnectorbetweenpumpandHPCcalibrator•1rollofTeflontape•ProtectivecarryingcaseAccessories•PressurehoseforT-960/970,0.5meter•PressurehoseforT-960/970,1.0meter•PressurehoseforT-960/970,2.0meter•PressurehoseforT-960/970,5.0meter•SetofBSPfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x3/8”,1x1/2”•SetofNPTfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x1/4”,1x3/8”1x1/2”•ConnectionsforAPMH/Spressuremodules•Fitting1/8”NPTmaleto1/4”NPTmaleforAPM-Hpressuremodule•Fitting1/4”NPTmaleto1/4”NPTmaleforAPM-Spressuremodule
HPC500, System B • BXX/Vacuum to 2 bar (30 psi) • BHX/Vacuum to 20 bar (290 psi)Thissystemincludesthedualfunc-tionpneumatichandpump.Withthispumpyoucancalibratebothvacuumandpressureapplications.Ittakesjustafewsecondstoswitchbetweenvacuumandpressure,justpushonebut-ton(valve)onthehandpump.
T-965 and T-975 hand pumps for system BModelT-965andT-975pneumaticpressurepumpsfea-turebothvacuumandpressuregeneration.Quickswitch(valve)makesiteasytoswitchfromvacuumtopressuremeasurement.Abuilt-inreleasevalve,avolumeadjusterforfineadjustmentandadualpressureoutputenableasafeandsimpleoperation.Theunitoffersbothmetricandimperialthreadsonthereferenceconnectionandthehose.Pressurerange,T-965................... vacuumto2bar(30psi)Pressurerange,T-975............... vacuumto20bar(290psi)Type..................................................................... PneumaticTestmedium.....................................................................AirOperation.................................................................. Scissor“O”-rings..................................................................Buna-NWettedparts..........Aluminum,brass,stainlesssteel,nylon,NylatronGSConnectiontotestobject..................Hose0.6m/24inwith1/4”BSPandNPTfemaleterminationsSize................................ 21.6x12.1x6.2cm/8.5x4.8x2.4inWeight............................................................1.4kg/3.0lbIncluded with System B delivery•HPCstandarddelivery(seepage5)•HandpumpT-965orT-975witha0.6m/24inhosewith1/4”BSPandNPTfemaleterminations•3/8”BSPfemaleadapterwith1/4”BSPandNPTfemaleterminations•QuickconnectorbetweenpumpandHPCcalibrator•1rollofTeflontape•ProtectivecarryingcaseAccessories•PressurehoseforT-975,0.5meter•PressurehoseforT-975,1.0meter•PressurehoseforT-975,2.0meter•PressurehoseforT-975,5.0meter•SetofBSPfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x3/8”,1x1/2”•SetofNPTfemalefittings,Teflontape,packings*Fittingsize:1x1/8”,1x1/4”,1x3/8”1x1/2”•ConnectionsforAPMH/Spressuremodules•Fitting1/8”NPTmaleto1/4”NPTmaleforAPM-Hpressuremodule•Fitting1/4”NPTmaleto1/4”NPTmaleforAPM-Spressuremodule
Model HPC400 • Handheld Pressure Calibrator
ORDERING INFORMATIONOrdernumber Description
HPC Type
400 Model
NONE Nocalibrator,pressuresystemonly
Pressurerange
002C Vacuumto2bar/30psigauge/compound
007C Vacuumto7bar/100psigauge/compound
020C Vacuumto20bar/290psigauge/compound
Calibrationcertificate
G NISTtraceablecalibrationcertificate
Accessories(Optional)
B Rechargeablebatterypack
C Softcase
Pressuresystem
IND Calibratoronly
AXX Syst.A,T-960pumprangesupto2bar/30psi
AHX Syst.A,T-970pumprangesupto20bar/290psi
BXX Syst.B,T-965pumprangesupto2bar/30psi
BHX Syst.B,T-975pumprangesupto20bar/290psi
Sampleordernumber
HPC 400 020C G BC BHX HPC400,vacuumto20bar,NISTtraceablecertificate,rechargeablebatterypackage,softcase,systemBT-975pump
Useful soft case - Option CTheHPC400canbedeliveredwithasoftcaseasoption.Thehandysoftcaseisdesignedforprotectionduringtransport.Thesoftcasehassepa-ratecompartmentsforHPC400(w/Velcrostrap),testleads,testhoses,temperatureprobe,andJOFRAAPMpressuremodule.Ashoulderstrapensuresconvenienttransportationwhenclimbingladders,etc.andthehandystrapatthebackmakesitpossibletohangtheinstrumentonapipe,ladderetc.Themanualandcalibrationdocumentsfitintoapocketonthefrontofthesoftcase.
Complete calibration systems TheHPC400isavailableasacalibratoronlyoroneof6ready-for-testsystemsthatarecompleteandequippedtomeetyourpressurecalibra-tionneeds.
ACCESSORIES
OptionC
99 Washington Street Melrose, MA 02176 Phone 781-665-1400Toll Free 1-800-517-8431