02 · 1 Contents Page Han ® 7 D .................................................................................................. 02.2 Han ® 8 D .................................................................................................. 02.4 Han ® 15-128 D......................................................................................... 02.6 Contacts Han D ® ...................................................................................... 02.14 Han DD ® .................................................................................................. 02.16 Contacts Han DD ® ................................................................................... 02.23 Han D/DD Han D ® / DD ®
24
Embed
Han D / DD - HARTING Rectangular Connectors | Electrical ... · Contacts Han D ® ... Material (seal) NBR Material (contacts) Copper alloy Specifications and approvals ... 09 15 000
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
02·1
Contents Page
Han® 7 D .................................................................................................. 02.2
Han® 8 D .................................................................................................. 02.4
Han® 15-128 D ......................................................................................... 02.6
Contacts Han D® ...................................................................................... 02.14
Han DD® .................................................................................................. 02.16
Contacts Han DD® ................................................................................... 02.23
Han D/DD
Han D® / DD®
02·2
Features• Innovative Han-Quick Lock® termination with reduced wiring
times• Time saving rapid termination by use of crimping contacts• for requirements up to 250 V / 10 A• Gold and silver contacts available• Suitable for thermo- and 1 mm FO contacts
Technical characteristicsNumber of contacts 7Electrical data acc. to IEC 61984
10 A 250 V 4 kV 3
Rated current 10 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage acc. to UL 600 VInsulation resistance ≥1010 ΩContact resistance ≤3 mΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 HBMating cycles ≥500Material (insert) PolyamideColour (insert) RAL 7032 (pebble grey)Material (seal) NBRMaterial (contacts) Copper alloy
DeratingCurrent carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-inter-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques acc. to IEC 60512-5-2
Ope
ratin
g cu
rrent
(A)
Ambient temperature (°C)
Ope
ratin
g cu
rrent
(A)
Ambient temperature (°C)① Han® 7 D ② Han® 15 D ③ Han® 25 D ④ Han® 40 D ⑤ Han® 64 D
Specifications and approvalsEN 60664-1IEC 61984EN 175301-801UL 1977 ECBT2.E235076
, ,
Han D/DD
Han® 7 D
02·3
Identification
Conductor cross-section (mm²)
Part number Drawing (dimensions in mm)Male Female
Han D® , Han-Quick Lock® termination, Contact surface:Silver plated
Only for thermoplastic hoods / housings
0,25 ... 1,5 09 21 007 2632 09 21 007 2732
Contact arrangement (view from termination side)
Han D® , Crimp termination
Please order crimp contacts separately.Only for thermoplastic hoods / housings
Features• Innovative Han-Quick Lock® termination with reduced wiring
times• Time saving rapid termination by use of crimping contacts• Gold and silver contacts available• Suitable for metal hoods and housings size Han® 3 A• High density of contacts
Technical characteristicsNumber of contacts 8Electrical data acc. to IEC 61984
10 A 50 V 0,8 kV 3
Rated current 10 ARated voltage 50 VRated impulse voltage 0.8 kVPollution degree 3Rated voltage 50 V AC, 120 V DCRated voltage acc. to UL 50 VRated voltage acc. to CSA 50 VInsulation resistance ≥1010 ΩContact resistance ≤3 mΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 HBMating cycles ≥500Material (insert) PolyamideColour (insert) RAL 7032 (pebble grey)Material (seal) NBRMaterial (contacts) Copper alloy
Specifications and approvalsEN 60664-1IEC 61984EN 175301-801UL 1977 ECBT2.E235076
, ,
Han D/DD
Han® 8 D
02·5
Identification
Conductor cross-section (mm²)
Part number Drawing (dimensions in mm)Male Female
Han D® , Han-Quick Lock® termination, Contact surface:Silver plated
for thermoplastics and metal hoods/housings
0,25 ... 1,5 09 36 008 2632 09 36 008 2732
Contact arrangement (view from termination side)
Han D® , Crimp termination
Please order crimp contacts separately.for thermoplastics and metal hoods/housings
Features• High density of contacts• for requirements up to 250 V / 10 A• Time saving rapid termination by use of crimping contacts• Gold and silver contacts available• Suitable for thermo- and 1 mm FO contacts
Technical characteristicsNumber of contacts 15, 25, 40, 50, 64, 80, 128Electrical data acc. to IEC 61984
10 A 250 V 4 kV 3
Rated current 10 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage acc. to UL 600 VRated voltage acc. to CSA 600 VInsulation resistance ≥1010 ΩContact resistance ≤3 mΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 V-0, HBMating cycles ≥500Dimensions wire wrap post 1 x 1 mmTermination length 22 mmMaterial (insert) PolycarbonateColour (insert) RAL 7032 (pebble grey)Material (contacts) Copper alloy
DeratingCurrent carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-inter-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques acc. to IEC 60512-5-2
Ope
ratin
g cu
rrent
(A)
Ambient temperature (°C)
Ope
ratin
g cu
rrent
(A)
Ambient temperature (°C)① Han® 7 D ② Han® 15 D ③ Han® 25 D ④ Han® 40 D ⑤ Han® 64 D
Specifications and approvalsEN 60664-1IEC 61984EN 175301-801UL 1977 ECBT2.E235076
, ,
DetailsATTENTION! Guide pins and bushes are prescribed (see chap-ter 80).
Remarks on the crimp techniqueThe wire gauges mentioned in the catalogue refer to geometric wire gauges of cables.
Coding pinUse of the coding pin prevents incorrect mating to other connec-tors of the same type. The male pin should be omitted from the opposing cavity in the male insert.
Features• High density of contacts• for requirements up to 250 V / 10 A• Time saving rapid termination by use of crimping contacts• Gold and silver contacts available• Suitable for thermo- and 1 mm FO contacts
Technical characteristicsNumber of contacts 24, 42, 72, 108, 144, 216Electrical data acc. to IEC 61984
10 A 250 V 4 kV 3
Rated current 10 ARated voltage 250 VRated impulse voltage 4 kVPollution degree 3Rated voltage acc. to UL 600 VRated voltage acc. to CSA 600 VInsulation resistance ≥1010 ΩLimiting temperature -40 ... +125 °CFlammability acc. to UL 94 V-0Mating cycles ≥500Material (insert) PolycarbonateColour (insert) RAL 7032 (pebble grey)
DeratingCurrent carrying capacityThe current carrying capacity of the connectors is limited by the thermal load capability of the contact element material including the connections and the insulating parts. The derating curve is therefore valid for currents which flow constantly (non-inter-mittent) through each contact element of the connector evenly, without exceeding the allowed maximum temperature.Measuring and testing techniques acc. to IEC 60512-5-2
Ope
ratin
g cu
rrent
(A)
Ambient temperature (°C)① Han® 24 DD ② Han® 42 DD ③ Han® 72 DD ④ Han® 108 DD
Derating
Ope
ratin
g cu
rrent
(A)
Ambient temperature (°C)① Han® 24 DD ② Han® 42 DD ③ Han® 72 DD ④ Han® 108 DD
Specifications and approvalsEN 60664-1IEC 61984
, ,
DetailsGuide pins and bushes are recommended (see chapter 80).
Remarks on the crimp techniqueThe wire gauges mentioned in the catalogue refer to geometric wire gauges of cables.
Coding pinUse of the coding pin prevents incorrect mating to other connec-tors of the same type. The male pin should be omitted from the opposing cavity in the male insert.
Modified contact arrangement The connector series Han DD® and Han D® equipped with all contacts may be used for voltages up to 250 V, pollution degree 3. A modified contact loading arrangement permits use up to 500 V also in the same pollution degree.
According to DIN EN 61 984 connectors should not be coupled or decoupled under electrical load.
Series Han DD®
10 A 400 V 6 kV 3Rated current 10 A Rated voltage 400 V Rated impulse voltage 6 kV Pollution degree 3
Contact arrangement view from termination side
10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3
● Working contact ○ Without contact M - Male insert F - Female insert
Series Han D®
10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3
Contact arrangement view from termination side
● Working contact ○ Without contact M - Male insert F - Female insert
Modified contact arrangement The connector series Han DD® and Han D® equipped with all contacts may be used for voltages up to 250 V, pollution degree 3. A modified contact loading arrangement permits use up to 500 V also in the same pollution degree.
According to DIN EN 61 984 connectors should not be coupled or decoupled under electrical load.
Series Han DD®
10 A 400 V 6 kV 3Rated current 10 A Rated voltage 400 V Rated impulse voltage 6 kV Pollution degree 3
Contact arrangement view from termination side
10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3
● Working contact ○ Without contact M - Male insert F - Female insert
Series Han D®
10 A 500 V 6 kV 3Rated current 10 A Rated voltage 500 V Rated impulse voltage 6 kV Pollution degree 3
Contact arrangement view from termination side
● Working contact ○ Without contact M - Male insert F - Female insert