H. Leeb Sept 7/8, 2007 1 Workshop on European Small-Scale AcceleratorFacilities, Aghio s Nikolaos, Crete PROPOSED PHYSICS PROGRAMME AT PROPOSED PHYSICS PROGRAMME AT THE PLANNED MedAustron FACILITY THE PLANNED MedAustron FACILITY H. Leeb and G. Badurek Atomic Institute of the Austrian Universities
20
Embed
H. Leeb Sept 7/8, 2007 1Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete PROPOSED PHYSICS PROGRAMME AT THE PLANNED MedAustron.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
H. LeebSept 7/8, 2007 1Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
PROPOSED PHYSICS PROGRAMME AT PROPOSED PHYSICS PROGRAMME AT THE PLANNED MedAustron FACILITYTHE PLANNED MedAustron FACILITY
H. Leeb and G. BadurekAtomic Institute of the Austrian Universities
H. LeebSept 7/8, 2007 2Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
The Project MedAustronCancer is the 2nd important cause for death in EuropeIn Austria 36.000 new cases per year
18% of the primary tumors cannot be destroyed at the place of its originalthough no metastases have been formed
There is justified hope that most of these can be successfully destroyedby ion therapy
MedAustron is an Austrianinitiative for a facility for hadron therapy
55% not healed 45% healed
surgery
surgery andradiation therapy
chemotherapy
radiation therapy
primary tumor
metastases
H. LeebSept 7/8, 2007 3Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
Characteristics of the FacilityThe design project foresees irradiations with a proton and a carbon-ion beam. The accelerator is not fixed yet, but the design parameters are:
proton beam 120-400(800) MeV 1x1010s-1
carbon-ion beam 120-400 MeV 4x108s-1
The beam spot is about 1-4 mm2 andallows to scan the tumor in size anddepths. The latter is controlled via varying the energy of the beam.
H. LeebSept 7/8, 2007 4Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
Non-clinical Programme
1. radiation biology 2. pre-clinical research 3. physics research
Besides the use for cancer therapy, the accelerator facility will also serve for non-clinical research. The following research topics are envisaged at MedAustron
•Particle & High energy physics (Test of Detectors)•Nuclear physics•Atomic physics•Materials science•Dosimetry (cosmic & terrestrial)•others …
These non-clinical research activities will only take place during night time and holidays
H. LeebSept 7/8, 2007 5Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
120 – 800 MeV
Current layout of the MedAustron Facility
B?
A
10 m
H. LeebSept 7/8, 2007 6Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
N = f Ip σL0dM
N reactions/sf pulse frequency ( 1 Hz)Ip particles/pulse specific mass densityM mol massσ cross sectionL0 Loschmidt numberd target thickness
N = 6.0×105 σdA ProtonsProtons
N = 2.4×104 σd A 1212C-ionsC-ions
mbarn
atomic mass number
g cm-3
Nuclear Physics ExperimentsNuclear Physics ExperimentsAssessment of feasibility with MedAustron beam parameters
p incident flux
H. LeebSept 7/8, 2007 7Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
European Accelerators for Nuclear PhysicsEuropean Accelerators for Nuclear Physics
The incident particle flux of most European accelerators dedicated for nuclear physics is 2-3 oders of magnitude higher than the expected flux at MedAutron !
Currently a further increase of flux of stable
isotope ions by 2 orders of magnitude is under
discussion !
H. LeebSept 7/8, 2007 8Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
Expected integral reaction rate
A= 100 =10 g cm-3
p = 1010 s-1 (1H+) & 4×108 s-1 (12C6+)
1%1% statistical accuracystatistical accuracy
170 s 4250 s(71 min)
d = 1 m
ProtonsProtons 1212C-ionsC-ions
H. LeebSept 7/8, 2007 9Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
Typical setup for the measurment of angle-differential cross-sections
C = N w2
16 D2Count rate:
width of detector entrance window
target-detectordistance
H. LeebSept 7/8, 2007 10Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
H. LeebSept 7/8, 2007 19Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
ConclusionsConclusions
•MedAustron can become a homebase for preparation of experiments at international research facilities
•MedAustron can provide a useful training ground for young scientists with up-to-date tools
•MedAustron may serve for exploration and testing of new ideas and methods
•MedAustron may serve to run routine experiments yielding important data in fields in which no beam time at dedicated large research facilities can be allocated.
H. LeebSept 7/8, 2007 20Workshop on European Small-Scale AcceleratorFacilities, Aghios Nikolaos, Crete
For a viable longlasting developmentformal cooperation agreements withpartner laboratories are essential !