Top Banner
141

H Haunch- See Table Di

Dec 18, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: H Haunch- See Table Di
Page 2: H Haunch- See Table Di

Di

Bedding See table

Do / 3 Foundation Outer Bedding

materials and compaction each side, same requirements as haunch

Middle Bedding loosely placed uncompacted bedding except for Type 4

Haunch- See Table

Lower-Side See Table

Overfill Soil Category I, II, III

Do / 6 (Min.) Do Do (Min.)

H

Springline

Page 3: H Haunch- See Table Di
Page 4: H Haunch- See Table Di
Page 5: H Haunch- See Table Di

209.04 - “Borrow Type C (Backfill). This material shall have between 85 and 100% inclusive by dry weight, passing a 1” (25 mm) sieve and a maximum of 25% by dry weight, passing a No. 200 (75 μm) sieve.

Page 6: H Haunch- See Table Di

208.04 “For these areas, (below the roadway or

shoulders) backfill material shall be compacted to 95% or more of maximum density according to the requirements of subsection 202.05 (f).”

“For these areas, (locations other than the below the roadway and shoulders) backfill material shall be compacted to 90% or more of the maximum density according to the requirements of subsection 202.05 (f).”

Page 7: H Haunch- See Table Di

Standard Installations › Developed by ASCE (15-93) › Adopted by AASHTO (Sections

16 & 27) › LRFD Section 12 and Section 27

of Construction Standard

Page 8: H Haunch- See Table Di
Page 9: H Haunch- See Table Di
Page 10: H Haunch- See Table Di
Page 11: H Haunch- See Table Di
Page 12: H Haunch- See Table Di

DC Power Supply Data Acquisition Sys

Page 13: H Haunch- See Table Di

Soil Pipe Interaction Design & Analysis

Page 14: H Haunch- See Table Di

INCREASED PIPE DESIGN

PIPE

STRENGTH INSTALLATION

QUALITY

INCREASED MATERIAL QUALITY

2 1 3 4

INSTALLATION TYPE

Page 15: H Haunch- See Table Di
Page 16: H Haunch- See Table Di

1.5

1.0 0.5

0.0

0.5 0.0

1.0 1.5 2.0 2.5

3.0

3.5 4.0

4.5

0.0 0.5 1.0 1.5 0.0 0.5 1.0 1.5

Page 17: H Haunch- See Table Di

1.5

1.0 0.5

0.0

0.5 0.0

1.0 1.5 2.0 2.5

3.0

3.5 4.0

4.5

0.0 0.5 1.0 1.5 0.0 0.5 1.0 1.5

Page 18: H Haunch- See Table Di

We = prism load x VAF Where : VAF = vertical arching factor as per Heger distribution

Prism Load Area

Final Grade

O.D.

Page 19: H Haunch- See Table Di

Installation Type

VAF HAF

1 1.35 0.45 2 1.40 0.40 3 1.40 0.37 4 1.45 0.30

ARCHING FACTORS

Page 20: H Haunch- See Table Di

Vertical Pressures

Page 21: H Haunch- See Table Di

WE = FeγsBcH › Pipe – Section 12.10.2.1-1

Page 22: H Haunch- See Table Di
Page 23: H Haunch- See Table Di
Page 24: H Haunch- See Table Di

TRENCH

Vertical Pressures

Page 25: H Haunch- See Table Di

“Standard installations for both embankments and trenches shall be designed for positive projection, embankment loading conditions where Fe shall be taken as the vertical arching factor, VAF, specified in Table 12.10.2.1-3 for each type of standard installation.”

www.concrete-pipe.org

Page 26: H Haunch- See Table Di

www.concrete-pipe.org

Concrete Pipe Indirect Design – 12.10.4.3 D-Load Equation

Page 27: H Haunch- See Table Di
Page 28: H Haunch- See Table Di

Di

Bedding See table

Do / 3 Foundation Outer Bedding

materials and compaction each side, same requirements as haunch

Middle Bedding loosely placed uncompacted bedding except for Type 4

Haunch- See Table

Lower-Side See Table

Overfill Soil Category I, II, III

Do / 6 (Min.) Do Do (Min.)

H

Springline

Page 29: H Haunch- See Table Di

Bedding Factors

M = 0.170 We r M = 0.318 P r

We /P = 1.9 = Bf

75o

Page 30: H Haunch- See Table Di

D-Load

Supporting strength of a pipe loaded under three-edge bearing test conditions, expressed in pounds per linear foot per foot of inside diameter or horizontal span.

ASTM C-76 Class IV

D0.01 = 2000

DULT = 3000

Page 31: H Haunch- See Table Di
Page 32: H Haunch- See Table Di

Bedding Factors

Bf = ?

Page 33: H Haunch- See Table Di

Embankment Earth Load Bedding Factor

Page 34: H Haunch- See Table Di

www.concrete-pipe.org

Extra Safety Factor for Type 1 Installations

Page 35: H Haunch- See Table Di
Page 36: H Haunch- See Table Di
Page 37: H Haunch- See Table Di
Page 38: H Haunch- See Table Di
Page 39: H Haunch- See Table Di
Page 40: H Haunch- See Table Di

E = 96 + 1.44S (4.6.2.10.2-1) E = Distribution width perpendicular to span in inches S = Clear Span in feet

Page 41: H Haunch- See Table Di

Espan = Distribution width parallel to span in inches Espan = LT + LLDF(H) LT = length of contact area parallel to span (in) LLDF = live load distribution factor H = depth of fill

Page 42: H Haunch- See Table Di

E

Live Load Spread for Less Than 2 feet of Cover (single a (Perpendicular)

Espan

Page 43: H Haunch- See Table Di

E = 96 + 1.44S (4.6.2.10.2-1) E = Distribution width perpendicular to span in inches S = Clear Span in feet Note: Equation 4.6.2.10.2-1 is for an axle load. with pipe, having much smaller spans than boxes a distribution for wheel loads is more appropriate. Ewheel = 48 + 0.72S

Page 44: H Haunch- See Table Di

E

Live Load Spread for Less Than 2 feet of Cover (Parallel)

E2

WE

Page 45: H Haunch- See Table Di

E

Live Load Spread for Less Than 2 feet of Cover (single axle (Perpendicular)

Espan

Espan = lt + LLDF(H) (4.6.2.10.2-2)

Page 46: H Haunch- See Table Di

E

Live Load Spread for Less Than 2 feet of Cover (single axle (Perpendicular)

Espan

ALL = lw ww (3.6.1.2.6a-1) ALL = Espan * E ALL = rectangular area at depth H (ft2) lw = live load patch length at depth H (ft) ww = live load patch width at depth h (ft)

Page 47: H Haunch- See Table Di

wt = 20 in.

lt = 10 in. Tire Patch

Direction of Traffic Article 3.6.1.2.5

Page 48: H Haunch- See Table Di
Page 49: H Haunch- See Table Di
Page 50: H Haunch- See Table Di
Page 51: H Haunch- See Table Di

sw = wheel spacing, 6.0 ft. sa = axle spacing (ft)

Page 52: H Haunch- See Table Di

Hintd

Elevation View

sa

Interaction Depth for Tandem Axles (Perpendicular)

Plan View

lws when H<Hintd

lwt when H>Hintd lws when H>Hintd

sa

lws

lwt

PRdist < 0

Page 53: H Haunch- See Table Di

Hintw

Elevation View

Plan View

sw

Interaction Depth for Wheels (Perpendicular)

Wws if H< Hintw

Wws if H> Hintw

sw

Wws for a single wheel

Wws for two wheels

Page 54: H Haunch- See Table Di

sw = wheel spacing, 6.0 ft wt = tire patch width, 20 in. Di = inside diameter or clear span of the culvert (in)

Page 55: H Haunch- See Table Di

Where H < Hint-t

Ww = wt/12 + LLDF(H) + 0.06(Di/12) (3.6.1.2.6b-2)

Where H > Hint-t

Ww = wt/12 + sw + LLDF(H) + 0.06(Di/12) (3.6.1.2.6b-3)

Page 56: H Haunch- See Table Di

“For live load distribution parallel to culvert span, the wheel/axle load Interaction depth Hint-p shall be determined as:”

Hint-p = sa -

lt

12

LLDF

sa = axle spacing (ft) lt = tire patch length, 10 (in) LLDF = live load distribution factor

(3.6.1.2.6b-4)

Page 57: H Haunch- See Table Di

Where H < Hint-p

lw = lt/12 + LLDF(H) (3.6.1.2.6b-5)

Where H > Hint-p

lw = lt/12 + sa + LLDF(H) (3.6.1.2.6b-6)

Page 58: H Haunch- See Table Di

Pressure Area at the Top of the Pipe

ww

lw

Plan View

ww

lw

ALL = lw ww (3.6.1.2.6a-1)

Page 59: H Haunch- See Table Di

1 + IM 100 ( ) P (m)

ALL

PL = (3.6.1.2.6b-7)

PL = live load vertical crown pressure (ksf) P = live load applied at surface on all interacting wheels (kips) IM = dynamic load allowance as specified in Article 3.6.2.2 m = multiple presence factor specified in Article 3.6.1.1.2

Page 60: H Haunch- See Table Di

LRFD – Dynamic Load Allowance (3.6.2.2) › DLA = 0.33(1.0 - 0.125DE) DE = Depth of cover (ft)

Page 61: H Haunch- See Table Di

Design Code

Lanes AASHTO STD

AASHTO LRFD

1 1.0 1.2

2 1.0 1.0

3 0.90 0.85

4 0.75 0.65

Page 62: H Haunch- See Table Di

For Concrete Pipe, Load must be in Terms of lbs/ft

Do

1 ft.

L = Smaller of lw or Do

WL = PL * L = live load (lbs/ft)

lw

Page 63: H Haunch- See Table Di

12 Si

( ) ( WE + WF

BFE +

WL

BFLL ) D = (12.10.4.3.1-1)

BFLL = Live Load Bedding Factor

Page 64: H Haunch- See Table Di

Pipe Diameter, in

Fill Height, ft < 2 ft > 2 ft

12 3.2 2.4 18 3.2 2.4 24 3.2 2.4

30 and larger 2.2 2.2

Table 12.10.4.3.2c-1

Page 65: H Haunch- See Table Di
Page 66: H Haunch- See Table Di

Embankment Condition › Pipe Size = 36” I.D., 44” = 3.67 ft. - Do › Fill Height = H = 5 ft. › Soil Unit Weight = w = 120 lbs/ft3

› Check Type 2 and Type 3 Installations

Page 67: H Haunch- See Table Di

1. Determine Earth Load 2. Determine Live Load 3. Select Bedding 4. Determine Bedding Factor 5. Application of Factor of Safety 6. Selection of Pipe Strength

Page 68: H Haunch- See Table Di

Soil Prism Load: › PL = w H Do › PL = (120 lbs/ft3)(5 ft.)(3.67 ft.) › PL = 2202 lbs/ft › W = VAF x PL (AASHTO Equation 12.10.2.1-1) › Type 2 Type 3 › W = (1.40)(2202 lbs/ft) W = (1.40)(2202 lbs/ft) › W = 3083 lbs/ft W = 3083 lbs/ft

Page 69: H Haunch- See Table Di
Page 70: H Haunch- See Table Di
Page 71: H Haunch- See Table Di

γw = 62.4 pcf ID = 3 ft Wf = γw x π x (ID/2)2

Wf = 441 lbs/ft

Page 72: H Haunch- See Table Di

3.6.1.2.6a › “For single-span culverts, the effects of live

load may be neglected where the depth of fill is more than 8.0 ft. and exceeds the span length;”

Page 73: H Haunch- See Table Di
Page 74: H Haunch- See Table Di

LLDF = 1.15 + (3 ft – 2 ft) (8 ft – 2 ft)

(1.75 – 1.15)

LLDF = 1.25

Page 75: H Haunch- See Table Di

Hint-t = 6 ft. – (20”/12) – (0.06 * 36”)/12

1.25

Hint-t = 3.32 ft

Page 76: H Haunch- See Table Di

Hintw

Elevation View

Plan View

sw

Interaction Depth for Wheels (Perpendicular)

Wws if H< Hintw

Wws if H> Hintw

sw

Wws for a single wheel

Wws for two wheels

Page 77: H Haunch- See Table Di

“For live load distribution parallel to culvert span, the wheel/axle load Interaction depth Hint-p shall be determined as:”

Hint-p = sa -

lt

12

LLDF

Hint-p =

(3.6.1.2.6b-4)

4 ft – (10”/12) 1.25

Hint-p = 2.53 ft

Page 78: H Haunch- See Table Di

Hintd

Elevation View

sa

Interaction Depth for Tandem Axles (Perpendicular)

Plan View

lws when H<Hintd

lwt when H>Hintd lws when H>Hintd

sa

lws

lwt

PRdist < 0

Page 79: H Haunch- See Table Di

For The Single Axle (HS20)

Where H > Hint-t

Ww = wt/12 + sw + LLDF(H) + 0.06(Di/12) (3.6.1.2.6b-3)

Ww = (20”/12) + 6 ft + 1.25*5 ft + 0.06*3 ft

Ww = 14.1 ft

Where H < Hint-p

lw = lt/12 + LLDF(H) (3.6.1.2.6b-5)

lw = 10”/12 + 1.25*5 ft. lw = 7.1 ft

ALL = 14.1 ft x 7.1 ft = 100 ft2

Page 80: H Haunch- See Table Di

For The Tandem Axles

Where H > Hint-t

Ww = wt/12 + sw + LLDF(H) + 0.06(Di/12) (3.6.1.2.6b-3)

Ww = (20”/12) + 6 ft + 1.25*5 ft + 0.06*3 ft

Ww = 14.1 ft

Where H > Hint-p

lw = lt/12 + sa + LLDF(H) (3.6.1.2.6b-5)

lw = 10”/12 + 4 ft + 1.25*5 ft. lw = 11.1 ft

ALL = 14.1 ft x 11.1 ft = 156.5 ft2

Page 81: H Haunch- See Table Di

1 + IM 100 ( ) P (m)

ALL

PL = (3.6.1.2.6b-7)

Load P For the single axle – P = 16 kips x 2 wheel loads P = 32 kips For the tandem axle – P = 12.5 kips x 4 wheel loads P = 50 kips

Page 82: H Haunch- See Table Di

1 + IM 100 ( ) P (m)

ALL

PL = (3.6.1.2.6b-7)

IM = 33*[1 – 0.125 (H)] IM = 33*[1 – 0.125 (5)] IM = 12.375 m = 1.2 for a single lane

Page 83: H Haunch- See Table Di

1 + IM 100 ( ) P (m)

ALL

PL = (3.6.1.2.6b-7)

1 + 12.375

100 ( ) 32000 lbs (1.2)

100 ft2 PLs =

1 + 12.375

100 ( ) 50000 lbs (1.2)

156.5 ft2 PLt =

= 431.5 psf

= 430.8 psf

Page 84: H Haunch- See Table Di

Outside Diameter = 3.67 lbs/ft Spread length for Single Axle

› lw = 7.1 ft Spread length for Tandem Axles

› lw = 11.1 ft

Live load = O.D. x PL › WL = 3.67 ft x 431.5 psf = 1583.6 lbs/ft

Page 85: H Haunch- See Table Di

For Concrete Pipe, Load must be in Terms of lbs/ft

Do

1 ft.

L = Smaller of lw or Do

WL = PL * L = live load (lbs/ft)

lw

Page 86: H Haunch- See Table Di

Type 2 › WE = 3083 lbs/ft › WF = 441 lbs/ft › WL = 1583.6 lbs/ft

Type 3 › WE = 3083 lbs/ft › WF = 441 lbs/ft › WL = 1583.6 lbs/ft

Page 87: H Haunch- See Table Di

We will compare Type 2 and Type 3 installations.

Page 88: H Haunch- See Table Di
Page 89: H Haunch- See Table Di
Page 90: H Haunch- See Table Di

Earth Load Bedding Factors for Embankment Condition (Table 12.10.4.3.2a-1) › Type 2, BFE = 2.9 › Type 3, BFE = 2.3

Page 91: H Haunch- See Table Di

Pipe Diameter, in

Fill Height, ft < 2 ft > 2 ft

12 3.2 2.4 18 3.2 2.4 24 3.2 2.4

30 and larger 2.2 2.2

Table 12.10.4.3.2c-1

Type 2, BFLL = 2.2 Type 3, BFLL = 2.2

Page 92: H Haunch- See Table Di

Find D-load

Page 93: H Haunch- See Table Di

Design is based on 0.01 inch crack, so use a factor of safety of 1.0.

Page 94: H Haunch- See Table Di

D0.01 = 3,083 lbs/ft + 441 lbs/ft 2.9

1584 lbs/ft x 1.0 3 ft

D0.01 = 645 lbs/linear ft/ft of diameter

+ 2.2

Page 95: H Haunch- See Table Di

D0.01 = 3,083 lbs/ft + 441 lbs/ft 2.3

1584 lbs/ft x 1.0 3 ft

D0.01 = 751 lbs/linear ft/ft of diameter

+ 2.2

Page 96: H Haunch- See Table Di

Class I - D0.01 = 800 lbs/ft/ft Class II - D0.01 = 1000 lbs/ft/ft Class III - D0.01 = 1350 lbs/ft/ft Class IV - D0.01 = 2000 lbs/ft/ft Class V - D0.01 = 3000 lbs/ft/ft

Page 97: H Haunch- See Table Di
Page 98: H Haunch- See Table Di
Page 99: H Haunch- See Table Di
Page 100: H Haunch- See Table Di

Find D-load

Page 101: H Haunch- See Table Di

WE = FeγsBcH › Pipe – Section 12.10.2.1-1

Page 102: H Haunch- See Table Di
Page 103: H Haunch- See Table Di
Page 104: H Haunch- See Table Di
Page 105: H Haunch- See Table Di
Page 106: H Haunch- See Table Di
Page 107: H Haunch- See Table Di
Page 108: H Haunch- See Table Di

Not the Same Earth Load Bedding Factor As Circular Pipe

Page 109: H Haunch- See Table Di
Page 110: H Haunch- See Table Di

Bedding Factor Per AASHTO

Page 111: H Haunch- See Table Di

Fe = 1.4

Page 112: H Haunch- See Table Di

Bedding Factor Per AASHTO

Page 113: H Haunch- See Table Di

Pipe Diameter, in

Fill Height, ft < 2 ft > 2 ft

12 3.2 2.4 18 3.2 2.4 24 3.2 2.4

30 and larger 2.2 2.2

Table 12.10.4.3.2c-1

Page 114: H Haunch- See Table Di

34 x 53 horizontal elliptical pipe Positive projecting embankment

condition Type 2 Installation 1 foot of cover Soil unit weight of 120 lbs/ft3

Page 115: H Haunch- See Table Di

1. Determine Earth Load 2. Determine Live Load 3. Select Bedding 4. Determine Bedding Factor 5. Application of Factor of Safety 6. Selection of Pipe Strength

Page 116: H Haunch- See Table Di

Wall thickness = 5 in. (from ASTM C 507) Outside Span Bc = 53 in + 2 (5 in.) = 5.25 ft Soil Prism Load:

› PL = w H Bc › PL = (120 lbs/ft3)(1ft.)(5.25 ft.) › PL = 630 lbs/ft › W = VAF x PL (AASHTO Equation 12.10.2.1-1) › Type 2 › W = (1.40)(630 lbs/ft) › W = 882 lbs/ft

Page 117: H Haunch- See Table Di

γw = 62.4 pcf A = 10.2 ft Wf = γw x A

Wf = 636 lbs/ft

Page 118: H Haunch- See Table Di
Page 119: H Haunch- See Table Di
Page 120: H Haunch- See Table Di
Page 121: H Haunch- See Table Di

Espan = Distribution width parallel to span in inches Espan = LT + LLDF(H) LT = length of contact area parallel to span (in) LLDF = live load distribution factor H = depth of fill

Page 122: H Haunch- See Table Di

E = 96 + 1.44S (4.6.2.10.2-1) E = Distribution width perpendicular to span in inches S = Clear Span in feet

Page 123: H Haunch- See Table Di

Espan = Distribution width parallel to span in inches Espan = LT + LLDF(H) LT = length of contact area parallel to span (in) LLDF = live load distribution factor H = depth of fill

Page 124: H Haunch- See Table Di

E

Live Load Spread for Less Than 2 feet of Cover (single a (Perpendicular)

Espan

Page 125: H Haunch- See Table Di

E = 96 + 1.44 (53”/12) E = 102.36 inches = 8.53 ft.

LLDF = 1.39 E = 10”/12 + 1 ft x 1.39 E = 2.22 ft.

Page 126: H Haunch- See Table Di

ALL = E * Espan ALL = 8.53 ft x 2.22 ft ALL = 18.94 ft2

P = 32,000 lbs

M = 1.2

Page 127: H Haunch- See Table Di

1 + IM 100 ( ) P (m)

ALL

PL = (3.6.1.2.6b-7)

IM = 33*[1 – 0.125 (H)] IM = 33*[1 – 0.125 (1)] IM = 28.88

Page 128: H Haunch- See Table Di

1 + IM 100 ( ) P (m)

ALL

PL = (3.6.1.2.6b-7)

1 +

28.88 100 ( ) 32000 lbs (1.2)

18.94 ft2 PL =

PL = 2,613 psf

Page 129: H Haunch- See Table Di

OD = 5.25 ft. Espan = 2.22 ft Espan < OD, so use Espan for live load

calculation

WLL = 2.22 ft x 2613 psf WLL = 5,801 lbs/ft

Page 130: H Haunch- See Table Di

Type 2 › WE = 882 lbs/ft › WF = 636 lbs/ft › WL = 5801 lbs/ft

Page 131: H Haunch- See Table Di
Page 132: H Haunch- See Table Di

Bedding Factor Per AASHTO

Page 133: H Haunch- See Table Di

Fe = 1.4 p = 0.7 Bc = 5.25 ft. H = 1 ft. q= 0.263

Page 134: H Haunch- See Table Di

BFE = CA

CN - xq

CA = 1.337 CN = 0.630 x = 0.369 q = 0.263

BFE = 1.337

0.630 – 0.369*0.263

BFE = 2.5

Page 135: H Haunch- See Table Di

Pipe Diameter, in

Fill Height, ft < 2 ft > 2 ft

12 3.2 2.4 18 3.2 2.4 24 3.2 2.4

30 and larger 2.2 2.2

Table 12.10.4.3.2c-1

BFLL = 2.2

Page 136: H Haunch- See Table Di

Find D-load

Page 137: H Haunch- See Table Di

Design is based on 0.01 inch crack, so use a factor of safety of 1.0.

Page 138: H Haunch- See Table Di

D0.01 = 882 lbs/ft + 636 lbs/ft 2.5

5801 lbs/ft x 12 53 in.

D0.01 = 735 lbs/linear ft/ft of diameter

+ 2.2

Page 139: H Haunch- See Table Di

Class HE-A - 600 lbs/ft/ft Class HE-1 - 800 lbs/ft/ft Class HE-II - 1000 lbs/ft/ft Class HE-III - 1350 lbs/ft/ft Class HE-IV - 2000 lbs/ft/ft

Page 140: H Haunch- See Table Di

25 kips 25 kips 4 ft

Page 141: H Haunch- See Table Di