Top Banner
site #2/jinan h 2 0 20 h 2 0 20 site & cluster design energy performance Tim Bates, Matt Bindner, Alissa Chastain, Erik Scanlon, Chao Wang, Duoduo Zhai
32

h 2 0 20

Jan 03, 2016

Download

Documents

karyn-glenn

h 2 0 20. site & cluster design energy performance. Tim Bates, Matt Bindner , Alissa Chastain, Erik Scanlon, Chao Wang, Duoduo Zhai. ventilation tower. deep profile mullions. residential. elevated courtyards. office. residential. courtyard vegetation. office. courtyard pool. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: h 2 0 20

site #2/jinanh2020

h2020

site & cluster design

energy performance

Tim Bates, Matt Bindner, Alissa Chastain, Erik Scanlon, Chao Wang, Duoduo Zhai

Page 2: h 2 0 20

site #2/jinanh2020

Page 3: h 2 0 20

site #2/jinanh2020

Page 4: h 2 0 20

site #2/jinanh2020

elevated courtyards

deep profile mullions

courtyard vegetation

courtyard pool

ventilation tower

ground floor retail

office

residential

residential

office

Page 5: h 2 0 20

site #2/jinanh2020

building section

Page 6: h 2 0 20

site #2/jinanh2020

integrated environment conditioning

warm weather condition

Page 7: h 2 0 20

site #2/jinanh2020

integrated environment conditioning

warm weather condition

Page 8: h 2 0 20

site #2/jinanh2020

integrated environment conditioning

warm weather condition

Page 9: h 2 0 20

site #2/jinanh2020

integrated environment conditioning

cold weather condition

Page 10: h 2 0 20

site #2/jinanh2020

integrated environment conditioning

cold weather condition

Page 11: h 2 0 20

site #2/jinanh2020

integrated environment conditioning

cold weather condition

Page 12: h 2 0 20

site #2/jinanh2020

integrated environment conditioning

cold weather condition

Page 13: h 2 0 20

site #2/jinanh2020

neighborhood energy strategy

energy use reduction strategies

integrated environment conditioning

discourage cars – limited parking, pedestrian streetsmicroclimates – courtyards, vegetation, pools

strategic shading, screens and louversadaptable living units

limit elevator use solar orientation

Page 14: h 2 0 20

site #2/jinanh2020

unit plan

Page 15: h 2 0 20

site #2/jinanh2020

unit plan

Page 16: h 2 0 20

site #2/jinanh2020

unit plan

Page 17: h 2 0 20

site #2/jinanh2020

unit plan

Page 18: h 2 0 20

site #2/jinanh2020

unit plan

Page 19: h 2 0 20

site #2/jinanh2020

unit plan

Page 20: h 2 0 20

site #2/jinanh2020

unit plan

Page 21: h 2 0 20

site #2/jinanh2020

site plan

Page 22: h 2 0 20

site #2/jinanh2020

site plan

Site 2 Summary   FAR 2.54 Population 16,242 Housing units 5,414 Residential floor area 541,414 Commercial floor area 395,765 Building coverage 40%Average building height (floors) 6.35

Page 23: h 2 0 20

site #2/jinanh2020

cluster plan

Page 24: h 2 0 20

site #2/jinanh2020

site massing

Page 25: h 2 0 20

site #2/jinanh2020

elevators

19 elevator buildings in site

Page 26: h 2 0 20

site #2/jinanh2020

elevators

7 elevator buildings in cluster

Page 27: h 2 0 20

site #2/jinanh2020

energy pro forma results

Total heating (MJ)47%

Total cooling (MJ)9%

Total light-ing

(MJ)3%

Other uses (MJ)41%

Annual Operational Household Energy Consump-tion by Use

60,735

4,077 11,311

Energy Consumption per Household (MJ)

Operational

Transportation

Embodied

Page 28: h 2 0 20

site #2/jinanh2020

energy pro forma results

29%

44%

1%

11%

2%

6%7%

Per Household Common Area Energy Consumption

Pump

Elevator

Lighting(in-building)

Lighting(out-of-building)

Access security

Underground parking

Community facilities

Other

Page 29: h 2 0 20

site #2/jinanh2020

energy pro forma resultsSite Comparison

 Site 2 Wuying-Tan

(enclave)Sunshine

100 The Grid

Population 16,242 16,100 19,000 11,700 Pop. Density (# 1000 ppl/sq km) 32 36 54 38 F.A.R. 2.54 1.16 2.15 1.69 Building Coverage 0.40 0.28 0.14 0.31 Average Building Height (# of floors) 6.35 4.18 14.91 5.47 Land Use Mix 0.41 0.29 0.26 0.30 Car Ownership (vehicles/100 HH) 55 21 68 16

Energy Consumption per Household

 Site 2 Wuying-Tan

(enclave)Sunshine

100 The Grid

Operational 60,735 56,362 97,645 55,785 Transportation 4,077 8,484 23,657 7,352 Embodied 11,311 6,979 11,055 11,435 Total 76,123 71,825 132,357 74,572

Site 2 Wuying-Tan (enclave)

Sunshine 100 The Grid

-

20,000

40,000

60,000

80,000

100,000

120,000

140,000

Embodied

Transportation

Operational

Page 30: h 2 0 20

site #2/jinanh2020

energy pro forma results

Site 2 Wuying-Tan (enclave)

Sunshine 100 The Grid

-

20,000

40,000

60,000

80,000

100,000

120,000

140,000

Energy Consumption per Household

Embodied

Transportation

Operational

Site 2 Wuying-Tan (enclave)

Sunshine 100 The Grid

-

200

400

600

800

1,000

1,200

1,400

1,600

Energy Consumption per Site Sq. M.

Embodied

Transportation

Operational

Site 2 Wuying-Tan (enclave)

Sunshine 100 The Grid

-

2,000

4,000

6,000

8,000

10,000

12,000

Energy Consumption per Building Sq. M.

Embodied

Transportation

Operational

Page 31: h 2 0 20

site #2/jinanh2020

Page 32: h 2 0 20

site #2/jinanh2020