    ===========================================================HUAWEI GSMSSVGUIDE BOOK

    REGION:EAST JAVA

    PROJECT:HCPTROLLOUT

    PREPARED BY:FACHRURRASYID

    DOCUMENT VERSION:1.0

    RELEASED DATE:26AUGUST 2013

    Date Version Author Remark

    26th

    August 2013

    V1.0 Fachrurrasyid

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    2/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 2 of 19

    Table of Content

    1. Overview .. 32. Work Flow 33. Team Requirements . 54. Test Methodology and sequence . 65. Equipment List and configuration 76. Test Item for output KPI .. 87. SSV Report . 9

    7.1.Basic Information ... 97.2.OSS Part . 97.3.DT Part .. 10

    7.3.1. Mobile Test (for Plot) . 127.3.2. Mobile Test (For Function) . 137.3.3. Stationary Test .. 13

    7.4.Remarks/Justification Examples . 157.5.From others (Simulation) . 18

    8. Attention Items . 189. Reference .. 18

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    3/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 3 of 19

    1. OverviewSingle Site Verification (SSV) Test is a test performed on newly integrated sites, it is done by

    performing Drive test (Moving) and also stationery test around one particular target site. The

    purpose of this test is to ensure all the basic functions of the site cell are normal. Below are the

    items needed to verify with SSV:

    - Coverage (CI, RX Level & RX Quality)

    - BCCH frequency (No Interference)

    - No installation faults (No Crossfeeder, wrong antenna direction etc.)

    - Make service test calls (Functionality test of CS and PS access)

    2.Work FlowBelow is the flowchart of whole SSV Process for HCPT-RO-EJ:

    A. Preparation

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    4/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 4 of 19

    B. Confirm Status Site

    C. Perform SSV

    SSV Flowchart.docx

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    5/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 5 of 19

    3.Team Requirements

    1) Senior RNO (Team Leader)

    - Responsible of Team Lead and Progress of Project as a whole

    - Responsible of L0 KPI monitoring & optimization after SSV Pass

    2) Junior RNO (DT Coordinator)

    - Check & Analyze Sites before team go SSV (Neighbor relation & Initial Parameter)

    - Make optimization as needed based on pre-SSV Analyze result

    - Coordinate team for SSV (Make schedule, SSV monitoring and update progress)

    - Review SSV Reports compiled by DT analyst and send to Huawei

    - Make Justification and schedule Re SSV for reject SSV Reports

    - Reports for sites problem or need troubleshoot for SSV (Crossfeeder, site down, etc.)

    3) OSS Engineer

    - Provide daily data KPI Performance for all sites

    - Provide Alarm and monitoring data for all sites

    - Execute PCR optimization requested by RNO

    - Provide other data as requested by Huawei and/or RNO whenever needed

    4) DT Analyst

    - Compile SSV Reports

    - Make Coverage plot prediction and Route and send to team before SSV

    - Make justification as needed for SSV Reports5) DT Engineer

    - Perform Drive Test for Site SSV

    - Close coordinate with DT Coordinator

    - Report directly to Coordinator if found sites problem during SSV

    Sr.RNO/TL

    .

    Jr.RNO/DTCoordinator

    DT Engineer DT Analyst

    DT Engineer

    OSS Engineer

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    6/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 6 of 19

    4.Test Methodology and sequenceTest Methodology

    A. Mobile/Moving Test :- MS1 Idle Mode :

    1. Lock on GSM

    2. Lock on All sector BCCH

    - MS2 Dedicated Mode :

    1. Lock on GSM

    2. Use Command Sequence of Long Call to 212

    B. Stationary Test :For stationary test all test done with lock on BCCH of each cell

    1. Voice Call :

    a. Short Call to 212, Duration : 120 seconds, Wait : 10 seconds, Repeat : 10

    times

    b. MOC to MTC, MS2 make voice call to MS1, functionality test

    2. Packet Data :

    a. Download (DL) EDGE ; MS2 Use Command Sequence FTP DL; filesize : 1 Mb

    b. Upload (UL) EDGE; MS2 Use Command Sequence FTP UL; filesize : 300 Kb

    3. SMS :

    a. Send SMS from MS2 to MS1, functionality test

    4. Handover :

    a. Handover intra site :

    Lock to sector A BCCH, MS2 dedicated mode make long call to 212

    During call, force HO to sector B, using set target HO in GSM

    dedicated mode tab in TEMS MS option, and do the same from

    sector B to sector C

    Consecutively force HO with this order A B C B A C

    b. Reselection Inter Technology (2G to 3G) :

    Set RAT Control to lock GSM, lock to BCCH each cell

    When serving by Cell, change RAT Control to 3G

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    7/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 7 of 19

    Command sequence

    Test Type Test Item Command sequence use Apply to XML file

    1. Moving Test

    Moving

    Dedicated

    mode

    Long Call to 212 MS2HCPT

    DT_longCall_Idle_212 Moving Idle

    ModeNot needed MS1

    2. Stationary

    test

    a. Voice Short

    Call

    Short Call to 212;

    Duration : 120 s; Wait : 10 s;

    Repeat : 10 times

    MS2 HCPT DT_StaticVoice_212.xml

    b. Voice MOC

    to MTC

    Short Call from MS2 to MS1;

    Duration : 20 s; Wait : 10 s;

    Repeat : 2 times

    MS2 HCPT MOC-MTC.xml

    c. PS

    Download

    EDGE Download 1 MB data

    from FTP server MS2HCPT FTP DL

    SBY.xml

    d. PS UploadEDGE Upload 300 kB data to

    FTP serverMS2 HCPT edge uL optim

    300KB.xml

    e. SMSSend SMS from MS2 to MS1;

    Repeat : 2 timesMS2 HCPT DT_sms.xml

    f. Handover

    test

    Long Call to 212, change

    target HO during callMS2 HCPT

    DT_longCall_Idle_212

    5.Equipment List and configurationMain Equipment :

    No Equipment Number

    of

    item(s)

    Specification Configuration

    1 Notebook 1 Recommended:

    Notebook with minimum dual

    core processor,RAM 1 GB, Hard disk 350 GB

    Windows XP Based,

    Pre-Installed TEMS Investigation

    8.0.3 (patched)Pre-Installed drivers for MS and

    GPS

    2 GSM Handset

    (MS1)

    1 Sony Ericsson K800

    (+ USB connector cable)

    Pre Installed TEMS Pocket

    3 GSM Handset

    (MS2)

    1 Sony Ericsson K790

    (+ USB connector cable)

    Pre-Installed TEMS Pocket

    4 GPS with USB

    interface

    1 BU-353 or similar type

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    8/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 8 of 19

    Additional Tools :

    No Tools Number of

    item(s)

    Specification

    1 Software 1 Additional Software for support :

    - Mapinfo 8.5

    - Image Capture (e.g: Snagit etc.)

    - Actix Analyzer

    - Google Earth

    - Atoll

    2 Power Inverter DC to

    AC

    1 500 Watt

    3 USB Hub 1 Any

    4 Power/electricity

    terminal

    1 Any

    6.Test Item for output KPIShow the all test mobile phone or modem and its relative output KPI. And show the KPI

    requirement.

    Test Type Test Item Apply to Pass Requirement

    1. Moving TestMoving

    Dedicated modeMS2

    Coverage :

    - HOSR = 100%

    - DCR = 0%

    - Rx Qual Sub (0-3) 95%

    Moving Idle

    Mode MS1

    Coverage :

    - Rx Level 98% match Cov Plot

    2. Stationary

    test

    a. Voice Short

    CallMS2 Call setup time 2 seconds

    b. Voice MOC to

    MTCMS2 CSSR = 100%

    c. PS Download MS2 EDGE DL 100 Kbps

    d. PS Upload MS2 EDGE UL 50 Kbps

    e. SMS MS2 CSSR = 100%

    f. Handover test MS2 HOSR Intra cell = 100%

    g. 3G reselection

    test MS2 Success = 100%

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    9/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 9 of 19

    7.SSV Report7.1. Basic Information- Site Identification from Update SDB HCPT (Site Database)

    Site Name ISAT MOJOKERTO CITY Site ID 132879 Cluster No. -Longitude 112.41991 Latitude -7.51006

    Swap Time - Drive Test 14 Agustus 2013

    Address Dusun Jampirogo Gg.II Desa.Jampirogo Kec.Sooko Kab.Mojokerto JATIM.

    - Site Verification (Database data from BSC Dump & Measured data verified by DT

    result)

    SECTOR 1 SECTOR 2 SECTOR 3

    Database Measured Database Measured Database Measured

    Cell ID 13849 13849 13851 13851 13852 13852

    LAC 13750 13750 13750 13750 13750 13750

    MCC 510 510 510 510 510 510

    MNC 89 89 89 89 89 89

    BSIC 0-4 0-4 0-4 0-4 0-4 0-4

    BCCH 841 841 848 848 850 850

    - Plot BCCH (Plot using Nastar from BCCH actual)BCCH Plot Sector 1 BCCH Plot Sector 2 BCCH Plot Sector 3

    7.2. OSS PartSSV report data needed from OSS :

    - Neighbor List 2G to 2G

    - Neighbor List 2G to 3G

    - Radio Parameter Setting

    132879_2G to 2GNeighbor List.xlsx

    132879_2G to 3GN e i g h b o r L i s

    1 3 2 8 7 9 R aP a r a m e t e r S e

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    10/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 10 of 19

    7.3. DT Part7.3.1. Mobile Test (for Plot)

    A. Dedicated CI and Handover Plot

    - Verify All Cell working normally, serving in Dedicated Mode

    - Verify no Drop Call, no Interference and no Blocking or Fading of coverage

    - Take Photo Justification for end of route or Blocking by surrounding

    - Verify Handover success to all surrounding neighbor sites :

    Cell A to NCell OK NOKNCell to Cell

    AOK NOK

    Cell B to NCell OK NOKNCell to Cell

    BOK NOK

    Cell C to NCell OK NOKNCell to Cell

    COK NOK

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    11/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 11 of 19

    B. IDLE Cell ID Plot

    - Verify All Cell working normally, serving in Idle Mode

    - Verify no Crossfeeder

    - Verify no Co-Channel BCCH with neighbor sites

    C. Predicted Over lay for Site 132879 (IDLE RX LEVEL PLOT)

    - Verify Rx Level Plot must Match with Coverage Plot

    - Verify for any justification if Rx Level actual doesnt match CovPlot (Blocking, Hilly

    Terrain etc.)

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    12/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 12 of 19

    D. Routes driven inside site (Rx_Lev Average DEDICATED MODE)

    - Verify Rx Level Plot in Dedicated is normal

    - Power Control should be put in consideration for Dedicated Plot (Rx Level tend to

    decrease along with Power Contro enabled)

    E. Routes driven inside site (RxQual DEDICATED MODE)

    - Verify Rx Qual Sub 3 in 95% of all plot Dedicated Mode

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    13/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 13 of 19

    7.3.2. Mobile Test (For Function)

    - Verify Handover success to each cell of that site (can be done by moving around site

    or take static handover test by applying Force Handover via TEMS) :

    Cell A to B OK NOK Cell B to A OK NOK

    Cell A to C OK NOK Cell C to A OK NOK

    Cell B to C OK NOK Cell C to B OK NOK

    - Verify Handover success to all surrounding neighbor sites :

    Cell A to NCell OK NOKNCell to Cell

    AOK NOK

    Cell B to NCell OK NOKNCell to Cell

    BOK NOK

    Cell C to NCell OK NOKNCell to Cell

    COK NOK

    7.3.3. Stationary Test

    SECTOR 1 SECTOR 2 SECTOR 3

    Voice Call

    Pass

    Pass

    Pass

    Pass

    Pass

    Pass

    SMS Test Pass Pass PassFTP DL Pass Pass Pass

    FTP UL Pass Pass Pass

    - PASS Test Functionality for :

    1) Voice Call (to:212 and MOC-MTC) = All call success (CSSR=100%)

    2) SMS Test (MS2 to MS1) = All SMS Sent & Received Successfully

    3) FTP DL 100 Kbps

    4) FTP UL 50 Kbps

    SECTOR 1 SECTOR 2 SECTOR 3Call Setup Time sec. 2.206 sec. 2.296 sec. 2.097

    FTP DL Kbps: 90.54 Kbps: 170.43 Kbps: 166.72

    FTP UL Kbps: 111.36 Kbps: 117.76 Kbps: 106.56

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    14/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 14 of 19

    - Take Capture for FTP DL and FTP UL (Replay from TEMS Investigation)

    DL throughput Chart Sector 1 UL throughput Chart Sector 1

    DL throughput Chart Sector 2 UL throughput Chart Sector 2

    DL throughput Chart Sector 3 UL throughput Chart Sector 3

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    15/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 15 of 19

    7.4. Remarks/Justification ExamplesA. End of Route Justification

    [1] End of road [2] End of road

    B. No Handover to neighbor site 133174 ISAT BABAT

    Site 133174 ISAT BABAT (CI:12051, 12052, 12053) was not serving during SSV causing no HO

    event to that site.

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    16/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 16 of 19

    Based on performance during that time, possibly site 133174 ISAT BABAT was not active:

    Performance datasite 133174 (CI 1205

    C. Coverage not dominant in Dedicated Mode

    Sector 2 not dominant

    Route of sector 2 cover by site 130078 SIMOKATRUNGANS (CI 5234), because suspect blocking

    by trees and fading by building

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    17/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 17 of 19

    D. Rx Level Idle not Match Coverage Plot Prediction

    Poor Rx Level in circled area caused by obstruction by a hill, blocking the coverage to that area

    E. Poor Rx Qual

    Poor rx qual because of terrain

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    18/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 18 of 19

    7.5. From Others (Simulation)- Coverage Plot Prediction made with Atoll 2.8.1.

    - Use Template from Huawei Region Project Team (can be downloaded from this link :

    https://drive.google.com/uc?id=0BzT10r8iGR4WUnNGZFN6OUJGcXc&export=download)

    8.Attention Items- Ensure before go SSV, Sites is up and running normally. Checking Sites for Alarm and

    Status is essential. Sites that is ready for SSV is clear from abnormal conditions.

    Report immediately to Project team if found following conditions :

    1) Locked BTS/Cell/TRX

    2) Service Impact Alarms such as :

    Equipment Alarms, e.g.: VSWR, DULNA, COBA

    Quality Alarms, e.g.: BTS with no transactions, No Call within

    predefined period3) TCH Availability cell hourly data for more than one day period is

  • 7/30/2019 Guide Book Ej Hcpt Ro Gsm 2g Ssv Update

    19/19

    HCPT GSM SSV Guide Book

    Commercial in confidence Page 19 of 19

    - GSM 2G SMS flow

    SMS Originating

    SMS Terminating

    - Handover Flow