1 © Nokia Siemens Networks OS86654EN53GLA0 NetAct Optimizer 3.0 for GSM GSM Adjacency Optimisation
Nov 10, 2015
1 Nokia Siemens Networks OS86654EN53GLA0
NetAct Optimizer 3.0 for GSM
GSM Adjacency Optimisation
2 Nokia Siemens Networks OS86654EN53GLA0
Nokia Siemens Networks Academy
Legal notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, product documentation and slide presentation material, all of which are forthwith known as Nokia Siemens Networks training material, are the exclusive property of Nokia Siemens Networks. Nokia Siemens Networks owns the rights to copying, modification, translation, adaptation or derivatives including any improvements or developments. Nokia Siemens Networks has the sole right to copy, distribute, amend, modify, develop, license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals can use the Nokia Siemens Networks training material for their own personal self-development only, those same individuals cannot subsequently pass on that same Intellectual Property to others without the prior written agreement of Nokia Siemens Networks. The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networks training session for development of groups without the prior written agreement of Nokia Siemens Networks.
3 Nokia Siemens Networks OS86654EN53GLA0
At the end of this module the trainee should be able to:
Edit the common adjacency optimisation parameters for a
separate deletion or creation of adjacencies
Set the required parameters for the automatic measurement-
based adjacency optimisation
Perform adjacency optimisation
Module Objectives
4 Nokia Siemens Networks OS86654EN53GLA0
GSM Adjacency Optimisation
How can I start the measurement-based adjacency
optimisation?
How can I
find the unused (unnecessary) adjacencies (deletion plan)?
find the missing adjacencies (creation plan)?
5 Nokia Siemens Networks OS86654EN53GLA0
Prerequisites
Invalid adjacencies fixed
Antennas defined for every cell
Interference matrix available
Adjacency Optimisation KPIs available for Adjacencies
Adjacency Constraints have been created or imported
Adjacency templates have been created for each object type
Template assignment rules have been created
6 Nokia Siemens Networks OS86654EN53GLA0
Methods and Startup Creation based on IM values, deletion based on ADCE KPIs
Check the KPI date and summarisation level
Select target objects from the Navigator, Map or Browser
7 Nokia Siemens Networks OS86654EN53GLA0
Starting GSM Adjacency Optimisation
Only ADCEs selected for measurement-based GSM adjacency optimisation
CIP or FEP can also be selected if available
Check the retrieved IM sets and priorities
8 Nokia Siemens Networks OS86654EN53GLA0
Adjacency Optimisation Tool View
9 Nokia Siemens Networks OS86654EN53GLA0
GSM Adjacency Optimisation
How can I start the measurement-based adjacency
optimisation?
How can I
find the unused (unnecessary) adjacencies (deletion plan)?
find the missing adjacencies (creation plan)?
10 Nokia Siemens Networks OS86654EN53GLA0
Common Parameters
Bidirectional optimisation (recommended)
Creation and deletion of adjacencies into and out from scope allowed (recommended for small scopes)
Check maximum and minimum Adjacency List Lengths
Changes to adjacencies between frequency bands can be disabled
Frequency band specific list length settings can be enabled
11 Nokia Siemens Networks OS86654EN53GLA0
Deletion Options for All Adjacency Types
Deleting outgoing adjacencies to foreign target cells can be allowed
Adjacencies without measurements will have 0 values for KPIs and are deleted
12 Nokia Siemens Networks OS86654EN53GLA0
Deletion Parameters for ADCE
Bidirectional deletion requires at least one bad value in both directions
Additional conditions can be used to avoid deleting adjacencies in low traffic cells
13 Nokia Siemens Networks OS86654EN53GLA0
Adjacency Deletion
Start optimisation
14 Nokia Siemens Networks OS86654EN53GLA0
Detailed Results on Deleted
Info column shows the creation/deletion reason
Include Change column defines the results to be saved in the plan
15 Nokia Siemens Networks OS86654EN53GLA0
Saving the Results
The results must be saved to the plan
Save is possible only to the plan that is open when Adjacency Optimisation starts, or to a plan that is created after pressing Save
After the save the results can be listed to Browser or shown on the map
16 Nokia Siemens Networks OS86654EN53GLA0
Exercise
Check and set Common parameters
Set Deletion parameters and start the optimisation
View the results and check different views in the Adjacency Browser
Change parameters and run again
Save the results into your plan
17 Nokia Siemens Networks OS86654EN53GLA0
GSM Adjacency Optimisation
How can I start the measurement-based adjacency
optimisation?
How can I
find the unused (unnecessary) adjacencies (deletion plan)?
find the missing adjacencies (creation plan)?
18 Nokia Siemens Networks OS86654EN53GLA0
Creation Options for All Adjacency Types
Creating BCCH and BCCH-BSIC collisions can be allowed if Frequency Optimisation is done in the same plan
Normally BCCH or BCCH-BSIC collisions are not allowed
If there are existing collisions in the network no new adjacencies are created for those cells unless collisions are allowed
19 Nokia Siemens Networks OS86654EN53GLA0
Creation Thresholds
Bidirectional creation requires good values in the outgoing direction
25 RXLEV = -96 dBm ( -95dbm)
Theta angle limitation not necessary (because of the measurements)
20 Nokia Siemens Networks OS86654EN53GLA0
Adjacency Optimisation
Start optimisation. Before starting, check that Deletion is not selected.
21 Nokia Siemens Networks OS86654EN53GLA0
Detailed Results on Created
Info column shows the creation/deletion reason
Include Change column defines results for the save
22 Nokia Siemens Networks OS86654EN53GLA0
Results
Save the results
Locate on Map or List to Browser to check the templates
You can select all by pressing Ctrl-A
23 Nokia Siemens Networks OS86654EN53GLA0
Exercise
Check and set Common parameters
Uncheck Delete Adjacencies box in the Deletion tab
Set Creation parameters and find the missing adjacencies in your scope
View the results in the Adjacency Browser
Change parameters and run again
Save the results into your plan
24 Nokia Siemens Networks OS86654EN53GLA0
Summary
Prerequisites
Site assignments and Antennas correctly defined
Adjacency templates and template assignment rules defined
Adjacency Constraints defined
Measurement-based deletion of GSM adjacencies Common Parameters
Deletion based on KPI values
Measurement-based creation of GSM adjacencies
Common Parameters
Creation based on Interference Matrix values
Results saved in to the plan Plan that is open when the tool is started
Plan that is created after pressing the Save button
After the save the results can be located on the Map and listed to the Browser