Top Banner
WHY GRUENBERG DRY HEAT STERILIZATION? Design assistance from leader in lab animal science sterilization Lowest total cost of ownership Greater output in a smaller footprint Safer operation Extended cage life Healthier environment (less heat, less moisture) PrecisionFlo TM GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization Lower Cost, Worry-Free & Green
12

GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Sep 09, 2018

Download

Documents

phamhanh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

WHY GRUENBERG DRY HEAT

STERILIZATION?

• Designassistancefromleaderin

labanimalsciencesterilization

• Lowesttotalcostofownership

• Greateroutputinasmallerfootprint

• Saferoperation

• Extendedcagelife

• Healthierenvironment(lessheat,

lessmoisture)

• PrecisionFloTM

GRUENBERG STERIDRY™ STERILIZERS

DRY HEAT SterilizationLower Cost, Worry-Free & Green

Page 2: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Hold the SteamDry heat sterilization systems use forced-air convection

technology for reduced energy consumption.

Pharmaceutical,MedicalDeviceand

LifeScienceResearchsterilizationhas

recentlyseenademandforgreener

technologiesthatrequirelessmaintenance.

Thisputsthepressureonequipment

engineerstodevelopinnovativewaysto

approachsterilization.Whiletraditional

steamautoclavesusewater;dryheat

sterilizationprovidesanalternativeto

steamthatusesnowater,lessenergy,

andrequireslessmaintenance.

Comparedwithsteam;dryheatisa

greenertechnologythateliminates

waterusage,providesmoreflexibility

forinstallationlocations,andcostsless

toownandoperate.

Moderndryheatsterilizationsystems

usingfocusedforcedairconvection

technologyareconsistentlydecreasing

thecycletime.Dependingontheload

configurationandcooldownrequirements,

thetypicalcyclelastslessthan3hours.

Theinitialcostofavailabledryheat

systemsisabout60%ofequivalent

sizedsteamautoclaves.Adryheat

sterilizeristwotothreetimeslighter

thananequivalentsteamsystem.

Becausethedryheatsterilizercanbe

riggedinplaceasmodules,thereare

considerablylessriggingchallenges

andcosts.Thedryheatsterilizerdoes

notneedtobepitmounted.

100% focused forced-air convectiontechnology.*PatentPending

Page 3: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

About the Company

ThermalProductSolutionsdesignsandmanufacturessterilizers, industrialandlaboratoryovensandfurnaces,aswellasenvironmental temperaturecyclingandstabilitytestchambers.

Page 4: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Truck-In Sterilizers

Page 5: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Features and Benefits� Greenoperationwithlowertotalenergyconsumption

� Economicalcost

� Flexibleinstallationandcustomizationoptions

� Validatedsterilizationcyclesforassuredresults

� Energyefficientelectricalheatingsystem

� Easytousecontrols

� PrecisionFloTMFullfocusedairflow

� HEPAFilters

� Dataacquisitioncapabilities

� Panelizeddesign

Page 6: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Cabinet Sterilizers

Page 7: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Features and Benefits� Greenoperationwithlowertotalenergyconsumption

� Lowertotalcostofownership

� Flexibleinstallationoptions

� Flexibledesignallowscustomizationtosuiteveryapplication

� Validatedsterilizationcycles

� Fitsintosmallspacesandthrough42"x84"doorways

� Modulardesignforeaseofinstallation

� Easytousecontrols

Page 8: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

POD Sterilizers

Page 9: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Features and Benefits� Greenoperationwithlowertotalenergyconsumption

� Economicalcost

� Flexibleinstallationandcustomizationoptions

� Validatedsterilizationcyclesforassuredresults

� Easytousecontrolsandaccesstocontainers

� ConditioningunitcanbeusedwithmultiplePODs

� Modulardesignallowsforsimplerearranging

� Perfectforchangestationsterilization

Page 10: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Superior Results. Superior Controller.

Advantages of Dry Heat vs. Steam

Dry Heat Sterilizer New Steam Autoclave

Volume(CUFT) 139 139

Footprint(SQFT) 34.3 Sterilizer48.5Pit91.2

MinimumDimensionofParts(IN) 31.5 62.4

Utilities ElectricPower Steam,coldwater,drain,pit,electric,compressedair

WaterUsage(GAL) 0 700

CostPerCycle(Calculated) HalfofAutoclave ****

Measured Energy Consumption–Dry Heat

300 ° F Soak: 60 Minutes SteriDry™Stage Time (min) Power (kW) Energy (kWH) Cost ($)

RampUp 20 61 20.3 $2.64

Soak 60 12 11.7 $1.53

Cool 100 4 5.4 $0.83

Total 180 37.4 $4.99

� Multifunctionprogrammablecontroller

� Colortouchscreen

� Real-timedatawithrecipesetupandstorage

� SCADAcompliant

USER EXAMPLE:

Page 11: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

Sterilizer Design Possibilities:� Proofofconceptandproofofprocess

� Developmentoftestplatformsandprototypeunits

� Optimizingproductionprocesses

� Pharmaceuticalprocessresearchandtesting

� Customprocesscontrolstosolvemanufacturingchallenges

Our SteriDry™ engineers are always

heretohelpyoudesignandimplement

our standard or custom sterilizers to

meet your project’s specific needs, no

matterhowdemanding.

Scanwithyoursmartphonetoseemoreaboutourdryheatsterilizers.

Page 12: GRUENBERG STERIDRY™ STERILIZERS DRY HEAT Sterilization ... · Hold the Steam Dry heat sterilization systems use forced-air convection technology for reduced energy consumption.

thermalproductsolutions.com

Gruenberg, Blue M, Tenney MailingAddress:P.O.Box150|WhiteDeer,PA17887-0150|USAPhone:(570)538-7200|Fax:(570)538-7380PhysicalAddress:2821OldRoute15|NewColumbia,[email protected] and Product Information are subject to change without notice.