CONTINUOUS FILAMENT WINDING ( CFW )GLASS REINFORCED POLYESTER ( GRP ) ISO 25780JOINT TYPE : FULLFACE GRP JACKING COUPLING
Rev. 00Design and R&D Department Technology and Product Development
SN
(tons)
150
JACKING LOAD Gj OD e MassID
e Mass SN
(tons)
100
ID
50
JACKING LOAD Gj OD
GRP JACKING DATASHEET
JACKING LOAD Gj OD e Mass SN
(tons)
ID
Lc = 148 mm (OD: 345 – 1499 mm) Lc =180 mm (OD: 1536 – 3065mm)
Page : 1/5
Design Assumptions: *The nominal pressure classes are PN1 and PN6 for jacking pipes and couplings. *The pipe lengths are 2 – 3 m. Custom lengths are available. *Factor of Safety ( for jacking load) = 3,5 *Ultimate compressive strength ≥ 85 N/m2 *Pipe thickness, weights and jacking load values are roughly calculated. All values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. *The manufacturer SUPERLIT has rights to change the technical data without notice.
CONTINUOUS FILAMENT WINDING ( CFW )GLASS REINFORCED POLYESTER ( GRP ) ISO 25780JOINT TYPE : FULLFACE GRP JACKING COUPLING
Rev. 00Design and R&D Department Technology and Product Development
400
300
JACKING LOAD Gj OD e
(tons)
SN
(tons)
Mass
ID
ID
ID SN
(tons)
200
e Mass SN
GRP JACKING DATASHEET
JACKING LOAD Gj OD
JACKING LOAD Gj OD
e Mass
Lc = 148 mm (OD: 345 – 1499 mm) Lc =180 mm (OD: 1536 – 3065mm)
Page : 2/5
Design Assumptions: *The nominal pressure classes are PN1 and PN6 for jacking pipes and couplings. *The pipe lengths are 2 – 3 m. Custom lengths are available. *Factor of Safety ( for jacking load) = 3,5 *Ultimate compressive strength ≥ 85 N/m2 *Pipe thickness, weights and jacking load values are roughly calculated. All values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. *The manufacturer SUPERLIT has rights to change the technical data without notice.
CONTINUOUS FILAMENT WINDING ( CFW )GLASS REINFORCED POLYESTER ( GRP ) ISO 25780JOINT TYPE : FULLFACE GRP JACKING COUPLING
Rev. 00Design and R&D Department Technology and Product Development
e
ID
700
SN
(tons)
600
JACKING LOAD Gj OD e
ID
(tons)
500
JACKING LOAD Gj OD
GRP JACKING DATASHEET
SN
(tons)
Mass
JACKING LOAD Gj OD e MassID
Lc = 148 mm (OD: 345 – 1499 mm) Lc =180 mm (OD: 1536 – 3065mm)
Design Assumptions: *The nominal pressure classes are PN1 and PN6 for jacking pipes and couplings. *The pipe lengths are 2 – 3 m. Custom lengths are available. *Factor of Safety ( for jacking load) = 3,5 *Ultimate compressive strength ≥ 85 N/m2 *Pipe thickness, weights and jacking load values are roughly calculated. All values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. *The manufacturer SUPERLIT has rights to change the technical data without notice.
Page : 3/5
CONTINUOUS FILAMENT WINDING ( CFW )GLASS REINFORCED POLYESTER ( GRP ) ISO 25780JOINT TYPE : FULLFACE GRP JACKING COUPLING
Rev. 00Design and R&D Department Technology and Product Development
e
ID
1200
SN
(tons)
1000
JACKING LOAD Gj OD e
ID
(tons)
800
JACKING LOAD Gj OD
GRP JACKING DATASHEET
SN
(tons)
Mass
JACKING LOAD Gj OD e MassID
Lc = 148 mm (OD: 345 – 1499 mm) Lc =180 mm (OD: 1536 – 3065mm)
Design Assumptions: *The nominal pressure classes are PN1 and PN6 for jacking pipes and couplings. *The pipe lengths are 2 – 3 m. Custom lengths are available. *Factor of Safety ( for jacking load) = 3,5 *Ultimate compressive strength ≥ 85 N/m2 *Pipe thickness, weights and jacking load values are roughly calculated. All values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. *The manufacturer SUPERLIT has rights to change the technical data without notice.
Page : 4/5
CONTINUOUS FILAMENT WINDING ( CFW )GLASS REINFORCED POLYESTER ( GRP ) ISO 25780JOINT TYPE : FULLFACE GRP JACKING COUPLING
Rev. 00Design and R&D Department Technology and Product Development
GRP JACKING DATASHEET
SN
(tons)
1400
JACKING LOAD Gj OD e MassID
Lc = 148 mm (OD: 345 – 1499 mm) Lc =180 mm (OD: 1536 – 3065mm)
Design Assumptions: *The nominal pressure classes are PN1 and PN6 for jacking pipes and couplings. *The pipe lengths are 2 – 3 m. Custom lengths are available. *Factor of Safety ( for jacking load) = 3,5 *Ultimate compressive strength ≥ 85 N/m2 *Pipe thickness, weights and jacking load values are roughly calculated. All values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. *The manufacturer SUPERLIT has rights to change the technical data without notice.