Top Banner
The Original "Top-Down" PV Mounting System for Ground Applications GroundTrac ® Benefits of GroundTrac ® Patent#6,360,491 • Industry’s preferred low cost and easiest to install ground mount system - Used for kW to Multi-MW projects • Patented ground mount system ships from available stock • Proprietary Drop-N-Lock rail insert drops in and locks ProSolar GroundTrac ® rails in place • Over 10 years of ProSolar’s proven design • Pre-engineered and tested for easy permitting • No cross-bracing required
4

GroundTrac · GroundTrac ® Benefits of ... • Pre-engineered and tested for easy permitting • No cross-bracing required. Insert vertical pipes into tees and fasten lower tee ...

Apr 24, 2018

Download

Documents

lamtu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: GroundTrac · GroundTrac ® Benefits of ... • Pre-engineered and tested for easy permitting • No cross-bracing required. Insert vertical pipes into tees and fasten lower tee ...

The Original "Top-Down" PV Mounting System for Ground Applications

GroundTrac®

Benefits of GroundTrac® Patent#6,360,491

• Industry’spreferredlowcostandeasiesttoinstallgroundmountsystem -UsedforkWtoMulti-MWprojects

• Patentedgroundmountsystemshipsfromavailablestock

• ProprietaryDrop-N-LockrailinsertdropsinandlocksProSolar GroundTrac®railsinplace

• Over10yearsofProSolar’sprovendesign

• Pre-engineeredandtestedforeasypermitting

• Nocross-bracingrequired

Page 2: GroundTrac · GroundTrac ® Benefits of ... • Pre-engineered and tested for easy permitting • No cross-bracing required. Insert vertical pipes into tees and fasten lower tee ...

Insertverticalpipesintoteesandfastenlowerteesetscrew.Centerpipesinfootingsbyslidingleftorright.Pourorpumpmixedconcreteintofootings.

Measureverticalpipelengths,allowing2”(min.)frombottomoffootingtoavoidpipecontactwithmoisture.

Digfootings.Lateral(lefttoright)footingspanslistedonpage4(bottom).Fronttorearfootingspanslistedinanglechartsonpage4(top).Refertoengineeringreportsforfootingspecs.

Assemblere-usablegradestakes(ProSolarmetalgradestakekitshown).Recommend2”x4”verticalsupport.Use ½” drill bit and 9/16” socket to attach gradestakekitto2”x4”.Attach1”x4”woodenhorizontalsupportusing3-1/2”(min.)C-clamps.Gradestakekitincludes:24”threadedmetalstake,aluminumspacerblock,boltandwasher.

Placehorizontal1-1/2”schedule40galvanizedwaterpipewithslip-onHollaender®Tees.AdjustC-clampsasnecessarytolevelpipe.

1

2

3

45

�����������������������������

��������������������

���������

���

�������

2”

Page 3: GroundTrac · GroundTrac ® Benefits of ... • Pre-engineered and tested for easy permitting • No cross-bracing required. Insert vertical pipes into tees and fasten lower tee ...

Completedinstallation.

Restrailontopofhorizontalpipes.Runstringlevelontoporbottomtoaligntopsofsupportrails.FastenrailinplacebyusingGroundTrac®drillguidealongtopandbottomofhorizontalpipes.DrillU-boltlockingholesinplace.Leaveatleastonedrillguideattachedafterdrillingtokeeprailinplace.

InsertU-boltintolockingrailholesandplaceDrop-N-Lockinsertintotherail.Removeremainingdrillguideandproceedwithotherrails.

Removegradestakes.Tightenallteesetscrewsto17ft-lbswithtorquewrench.Installremainingrails,evenlytighteningU-boltnuts.

Pre-assembleclampinghardwareandinstallsolarmodulesandEZrailendcaps.Install1-1/2”plasticpipeendcapsforschedule40pipeasnecessary.

EZrailendcap 9

�������

��������������������������

8

7

6

Installatleastonerailevery10’forproperpipespacing.

GroundTrac®DrillGuideBaseandDrillBit.

Page 4: GroundTrac · GroundTrac ® Benefits of ... • Pre-engineered and tested for easy permitting • No cross-bracing required. Insert vertical pipes into tees and fasten lower tee ...

Professional Solar Products (ProSolar) • 1551 S. Rose Ave., Oxnard, CA 93033 805-486-4700 • www.prosolar.com

©ProfessionalSolarProducts,IncMarch2011.GroundTrac®isaregisteredtrademarkandcoveredunderpat.#6,360,491

Photocourtesy:AccurateAir&Electric

Lateral (left to right) footing span (max) non-snow load

Lateral (left to right) footing span (max) 30 lb/ft2 snowload

Front to back footing spacing

Pre-slotted rails at:

124” x 2-1/2”

(3) 39.5” wide modules

10’

6’

See Angle Chart

84” on Center

136” x 2-1/2”

(4) 32.5” wide modules

10’

6’

See Angle Chart

84” on Center

GroundTrac® Rail Sizes

Number of Modules

164” x 3”

(4) 39.5” wide modules

8’

Not snowload rated

See Angle Chart

108” on Center

124” x 2-1/2” Support Rail Supports up to (3) 39.5” Wide Modules

124”

84”2-1/2”

39.5”

���

���

���

��

��

��������������������

����������

ArrayAngle

0°5°10°15°20°

Front to Rear FootingDistance108”108”106”104”101”

164” Rail

164” Rail Angle Chart

���

���

���

��

��

���������������������

���

���

�������������������������

�������������������������

��������

124” and 136” Rail

ArrayAngle

0°5°10°15°20°25°30°

Front to Rear FootingDistance84”84”83”81”79”76”73”

124” and 136” Rail Angle Chart

164” x 3” Support Rail Supports up to (4) 39.5” Wide Modules

164”

3”108”

39.5”

136” x 2-1/2” Support Rail Supports up to (4) 32.5” Wide Modules

136”

84”2-1/2”

32.5”

Refertoengineeringreportforfootingspecs