Top Banner
18

Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

Dec 13, 2015

Download

Documents

Jared Welch
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 2: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 3: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 4: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 5: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

200400

600800

10001200

14001600

0

5

10

15

20

25

Length (mm)

D (m

m2/

s)

Page 6: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 7: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 8: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

Gregor 2007

• Use GFP-Bcd to further 2005 work

• Use time-lapse two-photon microscopy– Fast and sensitive

• See Bcd on nuclei and anterior to posterior gradient

Page 9: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

Gregor 2007

• Fluorescence increases with time

Page 10: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

Quick Summary

• Bcd pattern seems to be established early and then stay regardless of – Nuclear proliferation– Nuclei size changes– Appearance of cell membranes

• Rises and falls with mitosis– Stays constant within for different divisions

• D is really small • Propose a new model that specifies nuclear

degradation

Page 11: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 12: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

Castle

• More recently have shown that characteristic lengths of source ~ gradient length

• Suggest there might be localized production necessary to give rise to patterns

• Big focus on methods take issue with the photobleaching in Gregor 2007

• Model their work and find their estimate of D is off and diffusion model still holds

Page 13: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 14: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 15: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.
Page 16: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

Is GFP-Bcd functional/normal?

• Yes.• GFP-Bcd can rescue a

knockout• Pattern the same as wt • Stain for endogenous

and GFP Bcd show colocalization

Page 17: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

Getting strange

• Bcd associated with nuclei seems to spread out during mitosis?

• Pretty constant

Page 18: Gregor 2007 Use GFP-Bcd to further 2005 work Use time-lapse two-photon microscopy – Fast and sensitive See Bcd on nuclei and anterior to posterior.

• Is it just binding/unbinding from nuclei?• Use photobleaching to show recovery– Implies transport across nuclear membrane– And also degredation

• Make a new model