GreenStar ™ iTEC Pro ™ QUICK REFERENCE GUIDE Getting Started Selecting the Menu button will allow you to access all applications. The Menu button will be on every screen. To access GreenStar Pro select Menu – GreenStar Pro. Selecting the GreenStar Pro application will navigate you to the GreenStar Main page. An Advanced Setup Tool is available in Softkey ‘F’ - select ‘iTEC Pro’ to set up the GreenStar Display for using iTEC Pro. Other Useful Buttons iTEC Pro Status Pie Installed – iTEC Pro compatible software installed on vehicle Pressing this brings up the diagnostic page. Configured – StarFire signal, iTEC Pro setup requirements are complete Enabled – iTEC Pro button pressed, “On” is displayed Active – Resume switch pressed GreenStar Display 2630 Setup Sequence Record Cancel iTEC Pro On/Off Diagnostics Enter, Done, Save, Finish iTEC Pro On iTEC Pro On iTEC Pro Off iTEC Pro Off 1. 2. 3. 4. Guidance Settings ShiftTrack Settings iTEC Pro View GreenStar Pro - Guidance iTEC Pro Settings Change Sequence (ft.) (ft.) (ft.) (ft.) (ft.) 0.0 0.0 0.0 0.0 0.0 608 608 10:22 am Sequence Offset End Turn Offset Enter Headlands Exit Headlands Enter Passable Interiors Exit Passable Interiors NOTE: A negative offset will begin the sequence earlier. A positive offset will delay the start of the sequence. Setup Sequences Guidance Resources Mapping Diagnostics Equipment Water Mgmt. Document Activations Memory iTEC Pro 10:28 am * Indicates required field Swath Control Pro What settings do you want to change? Resources Machine Implement Documentation Guidance Boundaries View Setup GreenStar Pro - Main Adjusts sequences to occur sooner or later iTEC Pro On/Off Button Create sequences and edit functions to occur sooner or later Adjusts the beginning of the turn iTEC Pro Status Pie Associate Sequences to Boundaries Select Turn Patterns, Minimize Skips or Overlaps, Impl Turn Radius
4
Embed
GreenStar iTEC Pro Quick Reference uide - John Deere...GreenStar ™ iTEC Pro™ Quick Reference Guide Getting Started Selecting the Menu button will allow you to access all applications.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
GreenStar™ iTEC Pro™ Quick Reference Guide
Getting StartedSelecting the Menu button will allow you to access all applications. The Menu button will be on every screen. To access GreenStar Pro select Menu – GreenStar Pro.
Selecting the GreenStar Pro application will navigate you to the GreenStar Main page. An Advanced Setup Tool is available in Softkey ‘F’ - select ‘iTEC Pro’ to set up the GreenStar Display for using iTEC Pro.
Other Useful Buttons iTEC Pro Status PieInstalled – iTEC Pro compatible software installed on vehiclePressing this brings up the diagnostic page.
Configured – StarFire signal, iTEC Pro setup requirements are complete
Enabled – iTEC Pro button pressed, “On” is displayed
Active – Resume switch pressed
GreenStar Display 2630
Setup Sequence
Record
Cancel
iTEC Pro On/Off
Diagnostics
Enter, Done, Save, Finish
iTEC Pro On
iTEC Pro On
iTEC Pro Off
iTEC Pro Off
1.
2.
3.
4.
Guidance Settings
ShiftTrack Settings iTEC ProView
GreenStar Pro - Guidance
iTEC Pro Settings Change
Sequence
(ft.)
(ft.)
(ft.)
(ft.)
(ft.)0.0
0.0
0.0
0.0
0.0
608608
10:22 am
Sequence Offset
End Turn Offset
Enter Headlands
Exit Headlands
Enter Passable Interiors
Exit Passable Interiors
NOTE: A negative offset will begin the sequence earlier.A positive offset will delay the start of the sequence.
Setup Sequences
Guidance Resources
Mapping
Diagnostics Equipment
Water Mgmt. Document
Activations Memory
iTEC Pro
10:28 am* Indicates
required field
Swath Control Pro
What settings do you want to change?
Resources
Machine
Implement
Documentation
Guidance
Boundaries
ViewSetup
GreenStar Pro - Main
Adjusts sequences to occur sooner or later
iTEC Pro On/Off Button
Create sequences and edit functions to occur sooner
or later
Adjusts the beginning of the turn
iTEC Pro Status Pie
Associate Sequences to Boundaries
Select Turn Patterns, Minimize Skips or Overlaps,
Impl Turn Radius
To Make iTEC Pro FunctionThe following criteria is required:• iTECProsoftwareinstalled(GS2/GS3andvehicle).• iTECProactivationondisplay.• VehicleandimplementdimensionsetupcompleteinGS2/GS3.
All information, illustrations and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice.
PFP11969 (11-12)
Creating Exterior, Interior, and Headland Boundaries
Required boundaries:• Exterior field boundary.• Exterior headland boundary.
Optional boundaries:• Interiorboundaries(passableorimpassable).• Interior headland boundaries (if interior boundary is
impassable).Exterior and interior boundaries are created by driving the boundaries.Exterior Headlands can be created in 3 ways:• Top and Bottom Offsets – creates headlands on
opposite ends of the field.• Constant Offset – creates a headland all the way
around the field.• Driven – records the boundary with a lateral offset of
where either the Tractor or implement travels.
NOTE: Interior Headland boundaries cannot use the Top and Bottom Offsets method.
Machine and Implement Dimensions
1) Insert a blank data card and select from the list.
2) Go to Apex - Setup Machine or Implement and click on Modify or New, then click “Get Reference Models and Settings”.
And
3) Save setup data from Apex.
The Skip tracks will indicate how many tracks or AB lines will be skipped. 0 tracks indicates the turn will be to the adjacent AB line.
To increase the number of tracks to skip, press the bottom arrow on the same side.
Turn Confirmation Warning
• The warning will be issued prior to start of headland turn.
• One of three turn indicators will be solid green, indicating the planned turn direction.
• The warning is confirmed by pressing the AutoTrac Resume switch on armrest or Accept button on warning.
To change the direction of the turn, press the bottom arrow on the opposite side.
To decrease the number of tracks to skip, press the bottom arrow on the opposite side.
NOTE: These changes will be made only for 1 turn. To make permanent changes, go to iTEC Pro Settings ‘Change’ button.
!
To continue straight without turning, press the Continue Straight button.
NOTE: This will cancel the turn and sequence at the current boundary location. Any subsequent sequences on the same pass will execute, but the next desired turn must be performed manually if iTEC Pro encounters another ‘Enter Headland’ transition within 20 seconds. If the next desired turn is after 20 seconds of exiting the headland, the Turn Confirmation indicator will be displayed and an automated turn may be completed.
The left or right arrow will be green to indicate which direction the turn will be.
Press the AutoTrac Resume switch or the Accept button to accept the turn.
Or