Page 1
•TheIAQInsulationTMforairducts•MadewithMicroban® antimicrobialprotection•Cost-effectivewithorwithoutPSA•ReducesHVACnoise
AP Armaflex®
Gray Duct Liner/Wrap
Duct Liner
For factory application or retrofit. Fiber free, mold resistant.
SUBMITTAL
FOR GREENER BUILDINGS
Page 2
AP Armaflex Gray Duct Liner/Wrapisengineeredforpinned,fabricatedfactoryapplicationinaccordancewithSMACNArequirementsand,asawraponexistingducts.Availableinarangeofwidthsincluding59˝and60˝,withorwithoutPSA. •Practical: Developedespeciallyforthesheetmetal
industry,andaneffectiveretrofitalternativeforinsulationcontractors
•Mold Resistant: MadewithMicrobanantimicrobialproduct protection •Indoor Air Quality: Fiber-free,formaldehyde-free,low
VOC’s,non-particulating •Plenum rated:Safeforinstitutionalairducts,meetsNFPA standards •Noise blocking and vibration dampening
Description
AP Armaflex Gray Duct Liner / Wrapisaflexibleelastomericthermalinsulation.Itsclosed-cellstructurepreventscondensationandmoisturewicking,andmakesitanefficientinsulation.ItismanufacturedwithouttheuseofCFCs,HFCsorHCFCs.TheMicroban®antimicrobialprotectionisregisteredbytheEnvironmentalProtectionAgencyforuseinairducts(EPAReg.No.1258-840-42182).ItisaddedduringmanufacturingtoprovideanextralevelofdefensetothenaturalmoldresistanceofAPArmaflex.
APArmaflexGrayDuctLineriseffectiveforreducingHVACnoise.
Itissuppliedinrolls46˝,47˝,48˝,56-1/4˝,59˝and60˝wide,in1˝or1/2˝(specialorder)thicknesses.WithPSA,itisintendedtobepinnedduringfactoryapplicationinaccordancewithSMACNArequirements.WithoutPSA,nopinningisrequiredifadheredwithArmaflex520Adhesive.
Approvals and Compliance
APArmaflexGrayDuctLiner/WrapmeetsrequirementsofNFPA90Aand90BforDuctCoveringsandLinings,andUL181forMoldGrowth.Approvedforuseinreturnairplenums,conformstoASTMC1534requirementsandwithstandstemperaturesof250˚F.
AllAPArmaflexinsulationmeetsrequirementsofInternationalEnergyConservationCode(IECC)andASHRAEforR-Value4.2at1˝thickness.R-Value2.2at1/2˝thickness.
Uses and Applications
APArmaflexDuctLiners/Wrapsareidealforairhandlingsystems,VAVunits,ductsandotherairsystemcomponentsrequiringcondensationcontrol,resistancetomoisture,damageorheatgain.Theyalsoreducenoisegeneratedbyfansandairmovementaswellastherattleorpoppingofsheetmetalairducts.Thegraylinerisespeciallyeffectivefactory-appliedforenduseareaslikeschools,hospitals,hotels,commercialandpublicbuildings.
Duct Liner www.armacell.comFor the latest document, please refer to our website.
Duct Liner/WrapInstallation
Note: Must be installed according to “Installation of Armaflex Insulations” publication (000-005).
Whenairstreamvelocitiesexceed4,000FPM(20.3m/second),metalnosingshouldbeappliedtoeveryleadingedge.Nosingmaybeformedonductsorbechanneledorzee-attachedbyscrews,rivetsorwelds.
APArmaflexGrayDuctLinerislight-tackself-adhering,whichprovidesconvenienttemporaryadhesionpriortopinning.ItisalsoavailablespecialorderwithoutPSA.Inthatcase,ifinstalledusingArmaflex520Adhesive,nopinningisrequired. (Please see “Wrap” illustration and caption.)ThefollowinginstructionsapplytothePSAproduct,thereforethemosttypicalapplication:
Theproductmustbesecuredwithmetalfasteners,eitherimpactdrivenorweld-secured,whichmustcompressthelinersufficientlytoholditinplace.
ALLARMACELLFACILITIESINNORTHAMERICAAREISO9001:2000CERTIFIED.
SecurewithmetalfastenersinaccordancewithSMACNApublication,“HVACDuctConstructionStandards,MetalandFlexible”.
Thetemperatureoftheairandoftheinsulationshouldbebetween40°F(4°C)and100°F(38°C)atthetimeofinstallation.
Preparesurfacebycleaningwithappropriatecleaner.Measure.
Cutwithsharpknife.Peelbackenoughreleaselinertostart.
Squareoffsheetalonganedgeorcorner.Pressthesheettothesurfacetakingcarenottotrapanyair.
ReachbehindtheArmaflexsheetandpeellinerbackwhilepressingthesheettothesurface.
Pressfirmly.Buttjointsrequiretheuseofcompressionjointstopreventthepossibleopeningofseams.
BOTTOM
TOP
SIDESIDE
Asretrofitoron-siteductwrap,usingArmaflex520Adhesiveonallsurfacestobejoined:1.CutBOTTOMpiece,tothesamewidthasduct.2.CutSIDEpieces,measuredflushwithducttopandextendingdownoveredgesofbottompiece.3.InstallTOPpiecelast,cuttoextendoversidepieces.Ifoutdoors,applytwocoatsArmaflexWBFinish.
ALCOHOL
1/4"
Page 3
Duct Liner www.armacell.com
For the latest document, please refer to our website.
Features Benefits
Closed cell structure
Resistsmoisture,nonwickingReducedwaterpresenceinsystemandinsulationNondustingLongerlifeWon’tcontributetoairqualityproblems
Made with Microban antimicrobial product protection
ResistsmoldontheinsulationEPAregisteredforuseinairductinsulation
Noise reducing, higher-density material
MoreproductiveworkenvironmentReducesorblocksHVACnoiseHelpspreventmetalductvibration,soundtransfer
Smooth surface that reduces dirt and debris accumulation
InhibitsamplificationofbiologicalcontaminantsBasisforcontinuingsystemhygiene
Elastomeric foam
FiberfreeResistanttoincidentaldamageNospecialtools;nodustmaskrequiredduringfabricationandinstallation
Inherent vapor retarder RequiresnomasticsCompetitivetotalinstalledcost
Notes
➀AP/ArmaflexGrayDuctLiner hasaflamespreadindexof lessthan25andasmoke developedindexoflessthan 50forallthicknessesuptoand including1˝(25mm)when testedaccordingtoASTME84 andCANULCS-102.Numerical flammabilityratingsalonemaynot definetheperformanceof productsunderactualfire conditions.Theyareprovided onlyforuseintheselectionof productstomeetlimitsspecified.
➁Withstandstemperatureof250°F (121°C)whentestedaccordingto ASTMC411.“TestMethodfor SurfacePerformanceofHigh- TemperatureInsulations”.Atthis temperature,AP/Armaflex GrayDuctLinerinsulationshows noevidenceofflaming,glowing, smoldering,delamination,melting orinsulationcollapse.Although thisinsulationwillwithstand hightemperatures,continuous usetemperatureshouldbelimited to180°F(82°C).
➂Attemperaturesbelow-20°F(-29°C) elastomericinsulationstartsto becomelessflexible.However,this characteristicdoesnotaffect thermalefficiencyorwatervapor permeabilityofArmaflexinsulation.
➃ReferenceOnly
Physical Properties
AP/Armaflex Gray Duct Liner / WrapFor applications that require pinning in accordance with SMACNA or retrofit “wrap” applications.
Specifications Values Test Method
Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C)
0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518
Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A
Flame Spread and Smoke Developed Index ➀Through 1˝ (25 mm) 25/50
ASTM E 84 CAN ULC S-102
Mold Growth Fungi Resistance Bacterial Resistance
UL181 ASTM G21/C1338 ASTM G22
Meets requirements Meets requirements Meets requirements
Water Absorption, % by Volume 0.2% ASTM C 209
Upper Use Limit ➁ 180˚F (82˚C)
Lower Use Limit ➂ -297˚F (-183˚C)
Erosion Resistance Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071
Corrosiveness Noncorrosive ASTM C 665
Odor Emissions No objectionable odors ASTM C 665
Density, Typical Range ➃ 3.0 – 6.0 lbs/ft ASTM D 1622 ASTM D 1667
Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC†
Nom. 1˝ (25mm) 0.05 0.17 0.080 0.44 0.60 0.49 0.50
Sound Absorption Coefficients at Frequency
Thickness STC Class
Nom. 1/2˝ (13 mm) 25
Nom. 1˝ (25mm) 25
Sound Transmission Class (STC) Sizes
Roll Width 46 ,̋ 47̋ , 48̋ , 56-1/4̋ , 59̋ and 60̋
Wall Thickness 1̋ and 1/2̋ (special order)
Page 4
021GS 001 06 08 NA NA © 2008 Armacell LLC Printed in United States of America
ARMACELL LLC TEL: 1 800 866-5638 FAX: 919 304-3847 [email protected] www.armacell.com 7600 Oakwood Street Extension • Mebane, NC 27302
Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, rely-ing upon the other source(s) to provide accurate information. Information provided as a result of Armacell’s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice.