Model Numbers QSGRJ-3P-XX* 3 zones, 120-240 V ~ QSGRJ-4P-XX* 4 zones, 120-240 V ~ QSGRJ-6P-XX* 6 zones, 120-240 V ~ QSGRJ-3P-1XX* 3 zones, 1 extra button column, 120-240 V ~ QSGRJ-3P-TXX* 3 zones, translucent cover, 120-240 V ~ QSGRJ-3P-1TXX* 3 zones, 1 extra button column, translucent cover, 120-240 V ~ QSGRJ-4P-1XX* 4 zones, 1 extra button column, 120-240 V ~ QSGRJ-4P-TXX* 4 zones, translucent cover, 120-240 V ~ QSGRJ-4P-1TXX* 4 zones, 1 extra button column, translucent cover, 120-240 V ~ QSGRJ-6P-1XX* 6 zones, 1 extra button column, 120-240 V ~ QSGRJ-6P-TXX* 6 zones, translucent cover, 120-240 V ~ QSGRJ-6P-1TXX* 6 zones, 1 extra button column, translucent cover, 120-240 V ~ QSGFP- Faceplate kit * “XX” in the model number represents color/finish code. See Colors and Finishes at the end of document. GRAFIK EyeR QS The GRAFIK EyeR QS controls up to six zones of light. The GRAFIK EyeR QS will operate the following sources with a continuous Square Law dimming curve or on a full conduction non-dim basis: • Incandescent • Tungsten Halogen • Electronic Low-Voltage (ELV) Switched • Magnetic Low-Voltage (MLV) Transformer • Metal Halide/High Pressure Sodium Switched • Neon/Cold Cathode • Lutron Tu-WireR Electronic Fluorescent Dimming Ballasts The GRAFIK EyeR QS can be configured for wired (QS link) or wireless (RF link) communication. LUTRON 1 2 3 4 Off Preset Close Open GRAFIK EyeR QS 1 | Lutron® 24/7 Technical Support 800.523.9466 product specifications 10.28.11 369-540a www.lutron.com
7
Embed
GRAFIK EyeR QS - Platt Electric Supply · GRAFIK EyeR QS The GRAFIK EyeR QS controls up to six zones of light. The GRAFIK EyeR QS will operate the ... Data link: twisted, shielded
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Model Numbers QSGRJ-3P-XX* 3 zones, 120-240 V ~
QSGRJ-4P-XX* 4 zones, 120-240 V ~
QSGRJ-6P-XX* 6 zones, 120-240 V ~
QSGRJ-3P-1XX* 3 zones, 1 extra button column, 120-240 V ~
QSGRJ-3P-TXX* 3 zones, translucent cover, 120-240 V ~
QSGRJ-3P-1TXX* 3 zones, 1 extra button column, translucent cover, 120-240 V ~
QSGRJ-4P-1XX* 4 zones, 1 extra button column, 120-240 V ~
QSGRJ-4P-TXX* 4 zones, translucent cover, 120-240 V ~
QSGRJ-4P-1TXX* 4 zones, 1 extra button column, translucent cover, 120-240 V ~
QSGRJ-6P-1XX* 6 zones, 1 extra button column, 120-240 V ~
QSGRJ-6P-TXX* 6 zones, translucent cover, 120-240 V ~
QSGRJ-6P-1TXX* 6 zones, 1 extra button column, translucent cover, 120-240 V ~
QSGFP- Faceplate kit
* “XX” in the model number represents color/finish code. See Colors and Finishes at the end of document.
GRAFIK EyeR QS The GRAFIK EyeR QS controls up to six zones
of light. The GRAFIK EyeR QS will operate the following sources with a continuous Square Law dimming curve or on a full conduction non-dim basis:
The GRAFIK EyeR QS can be configured for wired (QSlink)orwireless(RFlink)communication.
LUTRON
1
2
3
4
Off
Preset
Close
Open
GRAFIK EyeR QS
1 | Lutron® 24/7 Technical Support 800.523.9466
product specifications 10.28.11369-540a
www.lutron.com
Specifications
Model Numbers See previous page
Power 120 V~, 220–240 V~(nonCE),50/60Hz
Typical Power Consumption
7W,0PowerDrawUnits(PDUs).The GRAFIK EyeR QS is not powered from the link, Pin 2 should not be connected.TypicalPowerConsumptiontestconditions: all loads off, one button LED on.
Environment Ambientoperatingtemperature:32°Fto104°F(0°Cto40°C)Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only.
Communications Low-voltagetypeIECPELV/NECRClass2wiringconnectsGRAFIK EyeR QS to processor. EachHomeWorksR QS processor has two configurable links. GRAFIK EyeR QS communicates with the processor via the QS link or RF link.
ESD Protection Tested to withstand electrostatic discharge without damage ormemoryloss,inaccordancewithIEC801-2.
Surge Protection Tested to withstand surge voltages without damage or loss ofoperation,inaccordancewithIEEEC62.41-1991RecommendedPracticeonSurgeVoltagesinLow-VoltageACPowerCircuits.
Power Failure Provides10-yearpowerfailurememory:Automaticallyrestoreslighting to levels prior to power interruption.
Mounting Installsinastandard4-gangU.S.wallbox,3`in(89mm)deepis strongly recommended. Always allow at least 4`in(114mm)clearance above and below the control unit to provide adequate space for cooling.Wallplatesnapsonwithnovisiblemeansof attachment.
Line Voltage Wiring Eachlinevoltageterminalcanacceptone12AWG(4.0mm2)wire.
IEC PELV/NEC® Class 2 QS System Low-Voltage Wiring
Magnetic Low-Voltage 25–800VA/25–600W 40–1200VA/40–960W
Load Type Notes• WhendimmingElectronicLow-Voltage(ELV)lighting,anELVinterface(suchasPHPM-PA-DV-WH)
must be used with the control unit. Before installing an ELV light source, verify with the manufacturer that their transformer can be dimmed.
• Whencontrolling0–10Vloads,aTenVoltInterface(GRX-TVI)mustbeusedwiththecontrolunit.• Notallzonesmustbeconnected;however,connected zones must have a minimum load as
• Nozonemaybeloadedwithmorethanthecapacityspecifiedabove.Forhigherwattageapplications,or for 277 V~ applications, use Lutron®powermodulePHPM-PA,PHPM-WBX,PHPM-PA-DV,PHPM-SW,orPHPM-WBX-DV.
4 | Lutron® 24/7 Technical Support 800.523.9466
product specifications 10.28.11369-540a
www.lutron.com
QS Link Wiring
To additional QS devices
Pin2doesnotgetconnectedtotheGRAFIKEyeR QS – it does not require link power
12
AB
C
24 V
150
mA
P/N
500
-138
26 R
ev. A
8 mm
.3125 in
IECPELV/NECRClass2controlwiring:18AWG(0.75mm2) HomeWorksR QS Link 2000ft(610m)maximumtotal wire length per run
Datalink:twisted,shieldedpair22AWG to18AWG(0.25mm2 to 0.75 mm2)
FromHomeWorksR QS processor
DO NOT CONNECT PIN 2
AddTest
Setup
WiredRF
Communication
Repeater Status1 3 42 P
Hybrid Repeater
Power Repeater LinkCO
M
24 V9 V
1
MU
X
MU
X
2 3 4
ActivateTestAddTest
Setup
WiredRF
Communication
Repeater Status1 3 42 P
Hybrid Repeater
Power Repeater LinkCO
M
24 V9 V
1
MU
X
MU
X
2 3 4
ActivateTestAddTest
Setup
WiredRF
Communication
Repeater Status1 3 42 P
Hybrid Repeater
Power Repeater LinkCO
M
24 V9 V
1
MU
X
MU
X
2 3 4
ActivateTest
Hybrid Repeater
RF Link
GRAFIK EyeR QSHomeWorksRQSHybridRepeater
30ft(9m) maximum
30ft(9m) maximum
60ft(18m) maximum
30ft(9m) maximum
HomeWorksR QS RF Link1000ft(305m)maximumwire length per run
HomeWorksR QS RF Link1000ft(305m)maximumwire length per run
GRAFIK EyeR QS GRAFIK EyeR QS
5 | Lutron® 24/7 Technical Support 800.523.9466
product specifications 10.28.11369-540a
www.lutron.com
Colors and FinishesArchitectural Matte Finishes (standard) Architectural Metal Finishes (Faceplate kit only)
White WH
Ivory IV
Almond AL
Light Almond LA
Beige BE
Gray GR
Brown BR
Black BL
• Duetoprintinglimitations,colorsandfinishesshown cannot be guaranteed to perfectly match actual product colors.
• Colorchipkeychainsareavailableformoreprecise color matching: ArchitecturalMatteFinishes-AM-CK-1 ArchitecturalMetalFinishes-AMTL-CK-1
Satin Brass SB
Antique Brass QB
ClearAnodizedAluminum CLA
Black Anodized Aluminum BLA
Brass Anodized Aluminum BRA
SatinNickel SN
Bright Brass BB
Antique Bronze QZ
BrightNickel BN
BrightChrome BC
SatinChrome SC
6 | Lutron® 24/7 Technical Support 800.523.9466
product specifications 10.28.11369-540a
www.lutron.com
Colors and Finishes (continued)
• Duetoprintinglimitations,colorsandfinishesshowncannotbeguaranteed to perfectly match actual product colors.