In today’s global competition every day counts. Fast response times have become an important success factor for machine manufacturers. Reliable, on time delivery of machine components plays a critical role in this regard – especially when talking about individual and custom machine builders. With Rexroth’s GoTo Focused Delivery Program you benefit from easy ordering processes and on-time delivery of our high demand products across our broad range of technologies.
GoTo Europe2
Bosch Rexroth AG, R999000281, 2014-05
Your advantages f Reduced inventories and capital commitment
through short, reliable delivery times f Flexible response to customer and market demands
through high availability of many products f Simple, fast ordering via e-mail, fax, mail or
eCommerce at Bosch Rexroth or its sales partners
You receive the most common Rexroth products from indus-trial and mobile hydraulics, electric drives and controls, tightening technology, as well as linear motion and assembly technologies delivered reliably and on time. And that across Europe, taking into account product-dependent maximum order quantities and with unrivaled simplicity. Construct your machines and systems quickly and efficiently – we support you during the process.
GoTo Europe 3
R999000281, 2014-05, Bosch Rexroth AG
GoTo product overviews
f Industrial and Mobile Hydraulics
f Electric Drives and Controls, Tightening Technology
f Linear Motion Technology
f Assembly Technology
The GoTo product overviews according to technologies
The GoTo Focused Delivery Program offers a targeted selec-tion of our high-demand products with preferred service: As a result, you receive your products quickly and reliably, allowing you to respond to your market and customer requirements at any time.
You benefit from simplified access to product information, preferred order processing and reduced delivery times. This allows you to complete your machine or system on schedule.
Our GoTo product overviews, whether in printed form or on the Internet, show you the complete portfolio. In addition, our webpages quickly provide you with additional informa-tion on the respective product, on the technical data as well as on ordering.
GoTo Europe4
Bosch Rexroth AG, R999000281, 2014-05
1. Select product
1. Select productUse the GoTo product overviews to find the desired products.
2. View product dataNow visit the focused delivery program website – www.boschrexroth.com/goto. It offers simple access to additional product information, including data sheets, part numbers, specifications, downloads and more. 3. Order productTo order, contact Rexroth, your sales partner, or simply order online via our eShop: www.boschrexroth.com/eshop
2. View product data
f Product-specific information
f Maximum order quantities
3. Order product
f Availability f Delivery times f Prices
Your product in just three steps
Contents | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
5
Contents Frequency converters Page 07EFC3600 08Frequency Converter Fv 09Accessories 10
Automation systems 11IndraLogic XLC 12IndraMotion MLC 13Control hardware 14Function modules 15
HMI components 17Compact operator panel 18
I/O components 23IP20 24IP67 63
Tightening systems 77Hand-held nutrunners 78Control and power electronics 80Cables 81
GoTo Europe | Contents
Bosch Rexroth AG, R999000281, 2014-05
6
Contents Engineering software 85
Ordering information 89
Frequency converter | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
7
Frequency converters
With its EFC3600 frequency converter and Frequency Con-verter Fv, Rexroth offers both economical and easy-to-handle solutions for a wide variety of applications where energy-efficiency is a top priority. Variable-speed drives help to reduce operating expenses and minimize CO2 emissions. Standard converters with a power range from 0.4 kW to 90 kW offer an excellent price-performance ratio, simple operation, and comprehensive basic functions.
Straightforward, scalable, cost-effective f Easy, fast commissioning via the integrated operating
panel f Minimal installation effort, simple installation f Scalable output and functions for a wide range of appli-
cations f Cost-effective thanks to energy-efficient operation of
variable-speed drives
GoTo Europe | Frequency converter | EFC3600
Bosch Rexroth AG, R999000281, 2014-05
8
Product descriptionThe Rexroth EFC 3600 frequency converter is the compact, cost-effi cient, and energy-effi cient drive solution for the performance range from 0.4 kW to 4 kW. Easy commissio-ning and installation enable a wide range of applications.
Frequency converter EFC3600
f Compact and complete f Space-saving side-by-side assembly f Plug-in I/O terminals with brake chopper and mains fi lter f Removable operator panel with log and copy function f Straightforward parameter input
Features f Harmonized parameters for the entire series f Maximized energy effi ciency f Minimized motor noises f Continuously adjustable pulse frequency f CE-compliant f UL-listed
Detailed information:Instructions DOK-RCON03-EFC-3600***-IT
For ordering information on GoTo products, see Seite 88
Technical dataRated motor power kW 0.4 ... 4
Nominal motor voltage V AC 0 ... 480
Mains voltage V AC 200 ... 240/380 ... 480
Supply frequency Hz 50 ... 60
Rated continuous current A 1.2 ... 9.7
Overload capacity (G-type) % 200 (in 1 s)/150 (in 1 min)
Motor cable length (internal mains fi lter C3) m 15
Motor cable length (external mains fi lter C3) m 30
Ambient temperature °C —10 ... +50
Controller PID
Bus systems Modbus
Display 4-digit LCD: frequency, output voltage, output current, etc.
Frequency Converter Fv | Frequency converter | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
9
Frequency Converter FvFVCA01.2
f Several operating modes for diff erent applications f Simple operation and maintenance f Detachable fan f LCD operating panel with copy function f Advanced functions and high performance
Product descriptionThe Rexroth Fv frequency converter is the new, optimized drive solution for the automation of various applications in the power range up to 90 kW. The diff erent operating modes voltage/frequency (V/f), sensorless vector control (SVC), or fi eld-oriented vector control (FOC) allow a wide range of applications.
Detailed information:Instructions DOK-RCON02-FV*********IB
Features f Reliable quality f Worldwide availability and service f CE-compliant f UL-listed
Technical dataRated motor power kW 0.4 ... 90
Nominal motor voltage V 0 ... 480
Mains voltage V AC 380 ... 480
Supply frequency Hz 50 ... 60
Rated continuous current A 1.3 ... 183
Overload capacity (G-type) % 180 (in 10 s)/150 (in 1 min)
Motor cable length (internal mains fi lter C3) m 5/10
Motor cable length (external mains fi lter C3) m 50/75
Ambient temperature °C —10 ... +40
Controller PID
Bus systems Modbus/PROFIBUS
Display LCD: frequency, output voltage, output current, etc.
For ordering information on GoTo products, see Seite 88
GoTo Europe | Frequency converter | Accessories
Bosch Rexroth AG, R999000281, 2014-05
10
Product descriptionAccessory component for Rexroth frequency converters:Profi bus DP adapter for Rexroth Frequency Converter Fv for connection to a Profi bus network.External brake resistors and brake choppers for Rexroth Fv and EFC 3600 frequency converters to increase braking power.Mains fi lter for Rexroth Fv and EFC 3600 frequency conver-ters ensure that the EMC limit values are observed and suppress leakage currents.Shielding connector for EFC 3600 for simple and EMC-com-pliant fi xing of shielded lines.
EFC3600 frequency converter/Frequency Converter Fv – accesso-ries
f FVAA01.2 PROFIBUS adapter f FELB02.1 brake chopper f FELR01.1 brake resistor f FENF01.1 mains fi lter f FEAM01.1 shielding connector
Features f Accessories for use with the Rexroth Fv or Rexroth EFC
3600 frequency converters
Detailed information:Instructions DOK-RCON03-EFC-3600***-ITInstructions DOK-RCON02-FV*********IB
For ordering information on GoTo products, see Seite 88
Technical dataType FELR01.1 brake resistor
for EFC3600FELR01.1 brake resistor
for Frequency Converter Fv
Operating timeOT
% 10 10
Permanent braking power kW 0.06 ... 0.5 0.08 ... 9.6
Resistance Ω 1 ... 500 16 ... 750
Type FENF01.1 mains fi lterfor EFC3600
FENF01.1 mains fi lterfor Frequency Converter Fv
Continuous current A 6 ... 25 8 ... 90
Weight kg 0.26 ... 0.87 1.4 ... 4.4
Automatisierungssysteme | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
11
Automation systems
With IndraLogic XLC and IndraMotion MLC, Rexroth provi-des universal, scalable control solutions for a cost-effective automation of production tools and systems.Our “Open Core Engineering” gives you utmost freedom in creating efficient, future-proof engineering solutions, from compact PLC to flexible motion logic systems for challen-ging motion control tasks with a wide variety of functional packages.
As our basic system, IndraLogic XLC is suitable for all gene-ral automation tasks. The IndraMotion MLC motion logic system offers additional application-based technology features and robotic control for more demanding motion functions.
IndraWorks assists you with the overall engineering of your automation solution. All required tools are provided in this uniform software framework.The intuitive user interface with intelligent wizards facilita-tes your work, especially when dealing with complex tasks.
With the IndraLogic 2G PLC platform based on CODE-
SYS V3, you can create application programs in compliance with the latest IEC 61131-3 standard. All programming is done in IndraWorks. A host of user-friendly functions facili-tate the creation of modular, object-oriented tool software.
IndraControl L, the scalable family of controller-based components, makes it possible to create automation solu-tions tailored to your application in a uniform design. Cont-rollers can be easily extended thanks to optional modules and a versatile I/O module portfolio.
The sercos automation bus links all the components, from the drives to the controllers, up to the I/O peripherals into one high-performance system. With real-time and innovative features, sercos the automation bus provides maximum performance and flexibility in all applications.
GoTo Europe | Automatisierungssysteme | IndraLogic XLC
Bosch Rexroth AG, R999000281, 2014-05
12
Product descriptionThe IndraLogic XLC PLC system provides substantial advan-tages for intelligent automation of tools and systems. Scala-bility and open design of the IndraControl device families are the basis for fl exible, user-oriented solutions in central or distributed control topologies. Application-oriented task settings of the high-performance motion logic runtime system enable both fast I/O signal processing and highly dynamic motion control tasks.
IndraLogic XLC – high-performance PLC system for effi cient auto-mationFWA-CML
f Basic system for all general automation tasks f Comprehensive functions and numerous interfaces f Uniform engineering and convenient operation
Features f Cutting-edge control hardware with numerous extension
options f State-of-the-art PLC kernel IndraLogic 2G complies with
IEC 61131-3 standard, 3rd edition f High-performance communication via the latest genera-
tion of sercos for all peripherals f Synchronized motion control functionality
Detailed information:Brochure R999000060
For ordering information on GoTo products, see Seite 89
Technical dataControl hardware IndraControl L25 IndraControl L45 IndraControl L65
User memory MB 12 24 36
Retentive memory kB 256 256 256
Logic control IndraControl L25 IndraControl L45 IndraControl L65
PLC runtime system Conforming with IEC 61141-3
Conforming with IEC 61141-3
Conforming with IEC 61141-3
Freely confi gurable tasks (priority 0-20) 8 8 8
Min. PLC cycle time (synchronous to the sercos cycle)
ms 1 0.5 0.25
Typical processing time for 1,000 instructions (command mix)
µs 35 30 5
IndraMotion MLC | Automatisierungssysteme | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
13
IndraMotion MLC motion, robot, and logic control – an innovative system solutionFWA-CML
f Complete system solution with integrated motion logic f For all single- and multi-axis applications with the high-
est synchronicity f Up to 64 axes f Robot control with multi-axis path interpolation f Support of hydraulic axes
Product descriptionIndraMotion MLC facilitates synchronization, especially for multi-axis applications. Motion functions, such as master axes, electronic gears, electronic cams, and the innovative FlexProfi le for complex motion sequences, can be used quickly and transparently. Robot control provides full func-tionality for multi-axis path interpolation in space. Integrate hydraulic axes just as easily and quickly in your automation solution with the same tools and functionalities.
Detailed information:Brochure R999000031
Features f Cutting-edge control hardware with numerous extension
options f Extensive software libraries complying with IEC 61131-3
and PLCopen f Industry-specifi c library functions f Innovative FlexProfi le motion function for complex
motion sequences f Electronic programmable limit switches
For ordering information on GoTo products, see Seite 89
Technical dataControl hardware IndraControl L25 IndraControl L45 IndraControl L65
Controls in master axis grouping 64 64 64
Min. motion cycle time (setpoint generator) ms 2 1 1
Motion control IndraControl L25 IndraControl L45 IndraControl L65
Axes 16 32 64
Control axes (centrally controlled) 4 8 32
Number of axes per kinematic 16 16 16
Electronic cams (FlexProfi le) 4 4 4
Min. PLC cycle time ms 1 0.5 0.25
GoTo Europe | Automatisierungssysteme | Control hardware
Bosch Rexroth AG, R999000281, 2014-05
14
Rexroth IndraControl L25, L45, L65, and L85 controlsCML
f Uniform hardware platform for all rack-based controls f Flexible scaling of performance and function f Ideal for centralized and distributed control topologies f Open design with standardized communication inter-
faces
Features f DIN rail mounting f Protection to IP20 f Ambient temperature (operation): +5 ... +55°C f Extension through function and technology modules f Real-time clock f Display
Product descriptionRexroth IndraControl L is the compact control platform for easy DIN rail mounting, requiring minimal wiring work. It is available in various performance classes with many exten-sion options. In combination with our PLC system IndraLogic XLC or our motion control solution IndraMotion MLC, IndraControl L provides a maximum of fl exibility and openness for a wide variety of system designs.
Detailed information:Instructions DOK-CONTRL-IC*LX5*****-IT
For ordering information on GoTo products, see Seite 89
Technical dataControl hardware IndraControl L25 IndraControl L45 IndraControl L65
CPU SH4-compatible x86 compatible/500 MHz x86 compatible/1,000 MHz
Dimensions (H x W x D) mm 120 x 175 x 76 120 x 175 x 97.5 120 x 175 x 97.5
On-board I/O (digital) — 8/8 8/8
Local I/O extension bytes Max. 63 Inline modules, max. 64
Max. 63 Inline modules, max. 64
Max. 63 Inline modules, max. 64
Supported function modules 2 4 4
sercos 1x sercos III (optional) 1x sercos III (optional) 1x sercos III (optional)
Ethernet TCP/IP 1x (standard) 1x (standard)/2x (optional) 1x (standard)/2x (optional)
PROFIBUS 1x PROFIBUS master/slave (op-tional)
1x PROFIBUS master/slave (standard)
1x PROFIBUS master/slave (standard)
Profi net 1x PROFINET IO controller/device (optional)
1x PROFINET IO controller/device (optional)
1x PROFINET IO controller/device (optional)
Ethernet/IP EtherNet/IP scanner/adapter (optional)
EtherNet/IP scanner/adapter (optional)
EtherNet/IP scanner/adapter (optional)
Function modules | Automatisierungssysteme | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
15
Rexroth IndraControl Lxx 12VRS function modulesCFL01.1
f Easy-to-implement functional extensions for Indra-Control L control hardware
f Flexible combination options
Features f Expandable by up to 4 function modules (plug-in) f Protection to IP20 f Ambient temperature (operation): +5 ... +55°C f Ergonomic design
Product descriptionA range of function modules are available to integrate the IndraControl L into heterogeneous control topologies and adapt it to your functional requirements. The modules use the high-speed system bus to communicate with the control processor – this ensures that the high requirements for performance and functionality are met. Partial implementa-tion of functions into the modules reduces the load on the controller CPU.
Detailed information:Instructions DOK-CONTRL-FM*LXX**V12-AP
For ordering information on GoTo products, see Seite 89
Technical dataFunction module SERCOS III
CFL01.1-R3Cross communication
CFL01.1-Q2Realtime Ethernet/PROFIBUS
CFL01.1-TP
Fieldbus interface SERCOS III sercos II RT Ethernet and PROFIBUS
Dimensions (H x W x D) mm 120 x 20 x 70 120 x 20 x 70 120 x 20 x 70
Adjustable ring cycle time ms — 2/4/8 —
Max. number of slaves — 15/31/63 —
System support IndraLogic XLC, IndraMotion MLC
IndraMotion MLC IndraLogic XLC,IndraMotion MLC
GoTo Europe
Bosch Rexroth AG, R999000281, 2014-05
16
HMI Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
17
HMI components
Rexroth IndraControl V is the comprehensive HMI system range for individual control, operation and visualization in all industries. The program range covers controller-based devices, compact embedded PCs and high-performance industrial PCs.
With its scalable hardware and software, IndraControl V can be precisely adapted to your machine-specific require-ments.
IndraControl V integrates all the functions required for a cost-effective automation solution – from convenient opera-tion and clearly organized visualization to integrated cont-rols and diagnosis.
When combined with the proven system solutions from Rexroth, IndraControl V provides you with a complete automation solution for:
f Machine tools f Transfer machines f Printing and converting machines f Food processing and packaging machines f Forming machines f Woodworking machines f Textile machines f Handling and assembly systems
GoTo Europe | HMI Komponenten
Bosch Rexroth AG, R999000281, 2014-05
18 GoTo Europe | HMI Komponenten | Compact operator terminals18
f IP65 protection at front f IP20 protection at rear f 7.6 cm (3") display f 4 LED function keys f Seven system keys
Features f Text-based visualization in gray tones f FSTN display f Compact dimensions f Easy confi guration of the system visualization f Support of Asian characters
Product descriptionThe VCP 02 compact operator terminal is a machine opera-tor terminal that can be used to trigger machine functions depending on the specifi c application.The compact design and all-round seal on the rear side of the device make it suitable for a wide variety of uses. Any installation orientation can be selected.
Detailed information:Instructions DOK-SUPPL*-VCP02*****-PR
Rexroth IndraControl VCP 02
Technical dataInterfaces
Ethernet TCP/IP 1
USB (host) 2
Electrical data
Supply voltage U V DC 24
Supply voltage range U V DC 19 ... 30
Power consumption W 6
Mechanical data
Permissible temperature (operation) °C +5 ... +45
Permissible relative humidity (operation) % 5 ... 85, EN 61131-2
Weight kg 0.5
For ordering information on GoTo products, see Seite 89
HMI Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
19 Compact operator terminals | HMI Komponenten | GoTo Europe 19
Features f Text-based visualization in gray tones f FSTN display f Compact dimensions f Easy confi guration of the system visualization
Product descriptionThe VCP 05 compact operator terminal is a machine opera-tor terminal that can be used to trigger machine functions depending on the specifi c application.The compact design and all-round seal on the rear side of the device make it suitable for a wide variety of uses. Any installation orientation can be selected.
f IP65 protection at front f IP20 protection at rear f 7.6 cm (3") display f 6 LED function keys f 24 system keys
Detailed information:Instructions DOK-SUPPL*-VCP*05.2***-PR
Rexroth IndraControlVCP 05.2
Technical dataInterfaces
Ethernet TCP/IP 1
USB (host) 2
Electrical data
Supply voltage U V DC 24
Supply voltage range U V DC 19 ... 30
Power consumption W 6
Mechanical data
Permissible temperature (operation) °C +5 ... +45
Permissible relative humidity (operation) % 5 ... 85, EN 61131-2
Weight kg 0.5
For ordering information on GoTo products, see Seite 89
GoTo Europe | HMI Komponenten
Bosch Rexroth AG, R999000281, 2014-05
20 GoTo Europe | HMI Komponenten | Compact operator terminals20
f IP65 protection at front f IP20 protection at rear f 8.9 cm (3.5") display f Touch screen
Features f Graphics-oriented visualization f TFT touch display f Compact dimensions f Easy confi guration of the system visualization f Support of Asian characters
Product descriptionThe VCP 11 compact operator terminal is a machine opera-tor terminal that can be used to trigger machine functions depending on the specifi c application.The compact design and all-round seal on the rear side of the device make it suitable for a wide variety of uses. Any installation orientation can be selected.
Detailed information:Instructions DOK-SUPPL*-VCP*11.2***-PR
Rexroth IndraControlVCP 11.2
Technical dataInterfaces
Ethernet TCP/IP 1
USB (host) 2
Electrical data
Supply voltage U V DC 24
Supply voltage range U V DC 19 ... 30
Power consumption W 6
Mechanical data
Permissible temperature (operation) °C +5 ... +45
Permissible relative humidity (operation) % 5 ... 85, EN 61131-2
Weight kg 0.5
For ordering information on GoTo products, see Seite 89
HMI Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
21 Compact operator terminals | HMI Komponenten | GoTo Europe 21
Features f Graphics-oriented visualization f STN color touch display f Compact dimensions f Easy confi guration of the system visualization f Support of Asian characters
Product descriptionThe VCP 25 compact operator terminal is a machine opera-tor terminal that can be used to trigger machine functions depending on the specifi c application.The compact design and all-round seal on the rear side of the device make it suitable for a wide variety of uses. Any installation orientation can be selected.
f IP65 protection at front f IP20 protection at rear f 14.5 cm (5.7") display f Touch screen
Detailed information:Instructions DOK-SUPPL*-VCP*25.2***-PR
Rexroth IndraControlVCP 25.2
Technical dataInterfaces
Ethernet TCP/IP 1
USB (host) 2
Electrical data
Supply voltage U V DC 24
Supply voltage range U V DC 19 ... 30
Power consumption W 6
Mechanical data
Permissible temperature (operation) °C +5 ... +45
Permissible relative humidity (operation) % 5 ... 85, EN 61131-2
Weight kg 1
For ordering information on GoTo products, see Seite 89
GoTo Europe | HMI Komponenten
Bosch Rexroth AG, R999000281, 2014-05
22 GoTo Europe | HMI Komponenten | Compact operator terminals22
f IP65 protection at front f IP20 protection at rear f 26.4 cm (10.4") display f Touch screen
Features f Graphics-oriented visualization f TFT touch display f Compact dimensions f Easy confi guration of the system visualization f Support of Asian characters
Product descriptionThe VCP 35 compact operator terminal is a machine opera-tor terminal that can be used to trigger machine functions depending on the specifi c application.The compact design and all-round seal on the rear side of the device make it suitable for a wide variety of uses. Any installation orientation can be selected.
Detailed information:Instructions DOK-SUPPL*-VCP*35.2***-PR
Rexroth IndraControlVCP 35.2
Technical dataInterfaces
Ethernet TCP/IP 1
USB (host) 2
Electrical data
Supply voltage U V DC 24
Supply voltage range U V DC 19 ... 30
Power consumption W 19.2
Mechanical data
Permissible temperature (operation) °C +5 ... +45
Permissible relative humidity (operation) % 5 ... 85, EN 61131-2
Weight kg 2.3
For ordering information on GoTo products, see Seite 89
E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
23
I/O components
Fieldbus couplerFor connecting I/O modules to a higher-level fieldbus sys-tem
Analog input modulesFor acquiring analog signals from standard sensors and actuators
Analog output modulesFor outputting analog signals from standard sensors and actuators
Digital input modulesFor acquiring digital signals, e.g. from buttons, limit or proximity switches
Digital output modulesTo output digital signals for e.g. relays, valves, or signal lamps.
Power supply/segment modulesAllow the insertion of logic voltage or the electrical isola-tion of segments. Used in widely distributed systems.
Inline technology modulesTo process fast pulse trains or encoder signals.
Temperature modulesFor acquiring analog signals from temperature sensors
Communication modulesThe inline communication terminals allow for the connec-tion of devices with serial interfaces.
Block I/O modulesThe complete module minimizes costs compared to modu-lar stations and is the ideal solution for assembly in com-pact control cabinets.
AccessoriesMatching accessories for I/O components
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
24
Rexroth Inline bus coupler for sercos III with digital inputs and outputs R-IL S3 BK DI8 DO4-PAC
f Protection to IP20 f sercos III interfaces f sercos RJ45 socket f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 digital inputs 24 V DC f 4 digital outputs 24 V DC f Connection of sensors/actuators in 2 and 3-wire techno-
logy f 100 Mbit/s transmission rate at a minimal cycle time
of 250 μs f Supports sercos III V1.1.1
Product descriptionThe bus coupler is designed for use within a sercos III network and is the link to the Inline installation system.Up to 61 Inline devices can be connected at any point to an existing sercos III network using the bus coupler.
Detailed information:Data sheet DOK-CONTRL-ILS3BKDI8DO-KB
Technical dataSupply voltage V DC 24
Fieldbus system SERCOS III
Connection type RJ45
Digital inputs 8
Digital outputs 4
Local bus connection type Inline data jumper
Max. local bus users 63 (including 2 on bus coupler)
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (including plug) g 320
Dimensions (including plug) (W x H x T) mm 80 x 121 x 70
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
25
Rexroth Inline bus coupler for PROFINET with digital inputsand outputs R-IL PN BK DI8 DO4-PAC
f Protection to IP20 f PROFINET IO interface f PROFINET IO connection type: RJ45 socket f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 digital inputs 24 V DC f 4 digital outputs 24 V DC f Connection of sensors/actuators in 2 and 3-wire techno-
logy f IP parameter setting via PROFINET IO controller
Product descriptionThe bus coupler links the PROFINET network to the Inline installation system. It is equipped with 8 digital inputs and 4 digital outputs. Up to 61 additional Inline modules can be connected to the PROFINET coupler at the local bus.
Detailed information:Data sheet DOK-CONTRLILPN-BKDIO**-DA
Technical dataSupply voltage V DC 24
Fieldbus system PROFINET
Connection type RJ45
Digital inputs 8
Digital outputs 4
PROFIsafe support In prep.
Local bus connection type Inline data jumper
Max. local bus users 63 (including 2 on bus coupler)
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (including plug) g 320
Dimensions (including plug) (W x H x T) mm 80 x 121 x 70
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
26
Rexroth Inline bus coupler for PROFIBUS DP R-IL PB BK DI8 DO4/CN-PAC
f Protection to IP20 f PROFIBUS interfaces f PROFIBUS connection type: 9-pin D-SUB socket f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 digital inputs 24 V DC f 4 digital outputs 24 V DC f Connection of sensors/actuators in 2 and 3-wire techno-
logy f Operation of PROFIsafe users f Rotary code switch to set the PROFIBUS address
Product descriptionThe PROFIBUS bus coupler R-IL PB BK DI8 DO4/CN-PAC can be used to set up a distributed Inline station.It is equipped with 8 digital inputs and 4 digital outputs. All channels are labeled continuously.Up to 62 additional Inline modules can be connected in a series to the PROFIBUS coupler at the local bus.
Detailed information:Data sheet DOK-CONTRL-ILPBBKDIOCN-AW
Technical dataSupply voltage V DC 24
Fieldbus system PROFIBUS DP
Connection type 9-pin D-SUB socket
Digital inputs 8
Digital outputs 4
PROFIsafe support Yes
Local bus connection type Inline data jumper
Max. local bus users 63 (including 2 on bus coupler)
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (including plug) g 320
Dimensions (including plug) (W x H x T) mm 80 x 121 x 70
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
27
Rexroth Inline bus coupler for PROFIBUS DP R-IL PB BK DP/V1-PAC
f Protection to IP20 f PROFIBUS and local bus interfaces f PROFIBUS connection type: 9-pin D-SUB socket f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f Modular can be extended with Inline terminals f Electrical isolation of PROFIBUS interface and logic f DP/V1 for class 1 and class 2 master
Product descriptionThe PROFIBUS bus coupler R-IL PB BK DP/V1-PAC can be used to set up a distributed Inline station. Up to 62 additio-nal Inline modules can be connected in a series to the PROFIBUS coupler at the local bus.
Detailed information:Data sheet DOK-CONTRL-ILPBDPV1***-KB
Technical data Supply voltage V DC 24
Fieldbus system PROFIBUS DP
Connection type 9-pin D-SUB socket
PROFIsafe support No
Max. no. of local bus users 63
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (including plug) g 297
Dimensions (including plug) (W x H x T) mm 85 x 120 x 72
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
28
f Protection to IP20 f Acquisition of current and voltage signals f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 2 analog inputs f 3 current measuring ranges f 2 voltage measuring ranges f Connection of sensors in 2 and 3-wire technology
Product descriptionThe Inline terminal acquires analog voltage or current sig-nals. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILAI2/SF***-KB
Rexroth Inline terminal with 2 analog input channels R-IB IL AI 2/SF-PAC
Technical dataAnalog inputs 2 (single-ended)
Connection type Spring-cage connection
Voltage input range V 0 ... 10/±10
Current input range mA 0 ... 20/±20/4 ... 20
Sensor connection type 2, 3-wire connection
Resolution of measurements bits 16
Process data update ms < 1.5
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 47
Dimensions (including plug) (W x H x T) mm 12.2 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
29
f Protection to IP20 f Acquisition of current and voltage signals f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 analog inputs f 5 current measuring ranges f 7 voltage measuring ranges f Connection of sensors in 2-wire technology
Product descriptionThe Inline terminal acquires analog voltage or current sig-nals. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILAI8/SF***-KB
Rexroth Inline terminal with 8 analog input channels R-IB IL AI 8/SF-PAC
Technical dataAnalog inputs 8 (single-ended)
Connection type Spring-cage connection
Voltage input range V 0 ... 5/±5/0 ... 10/±10/0 ... 25/±25/0 ... 50
Current input range mA 0 ... 20/4 ... 20/±20/0 ... 40/±40
Sensor connection type 2-wire connection
Resolution of measurements bits 16
Process data update ms < 1.5
Local bus connection type Inline data jumper
Permissible temperature (operation) °C –25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 125
Dimensions (including plug) (W x H x T) mm 48.8 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
30
Features f 1 analog output f 2 current ranges f 1 voltage range f Connection of actuators in 2-wire technology
Product descriptionThe Inline terminal outputs analog voltage or current sig-nals. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILAO1/SF***-KB
f Protection to IP20 f Outputting of current and voltage signals f Diagnostic and status indicators f Accessories included (connection plug and labeling
fi eld)
Rexroth Inline terminal with 1 analog output R-IB IL AO 1/SF-PAC
Technical dataAnalog output 1
Connection type Spring-cage connection
Voltage output range V 0 ... 10
Current output range mA 0 ... 20/4 ... 20
Actuator connection type 2-wire connection
Resolution of measurements bits 16
Process data update ms < 1
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 48
Dimensions (including plug) (W x H x T) mm 24.4 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
31
f Protection to IP20 f Outputting of current and voltage signals f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 2 analog outputs f 2 current ranges f 1 voltage range f Connection of actuators in 2-wire technology
Product descriptionThe Inline terminal outputs analog voltage or current sig-nals. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILAO2/SF***-KB
Rexroth Inline terminal with 2 analog outputs R-IB IL AO 2/SF-PAC
Technical dataAnalog outputs 2 (automatically confi gured in relation to the terminal point used)
Connection type Spring-cage connection
Voltage output range V 0 ... 10
Current output range mA 0 ... 20/4 ... 20
Actuator connection type 2-wire connection
Resolution of measurements bits 16
Process data update ms < 1
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 48
Dimensions (including plug) (W x H x T) mm 48.8 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
32
Features f 2 analog outputs f 2 voltage ranges f Connection of actuators in 2-wire technology f Suitable for long actuator cables
Product descriptionThe Inline terminal outputs analog voltage signals. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILAO2/U/BP*-KB
f Protection to IP20 f Outputting of voltage signals f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Rexroth Inline terminal with 2 analog voltage outputs R-IB IL AO 2/U/BP-PAC
Technical dataAnalog outputs 2 (single-ended)
Connection type Spring-cage connection
Voltage output range V ±10/0 ... 10
Actuator connection type 2-wire connection
Resolution of measurements bits 16
Process data update ms < 1
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 96.8
Dimensions (including plug) (W x H x T) mm 12.2 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
33
Rexroth Inline terminal with 4 digital inputs R-IB IL 24 DI 4-PAC
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 4 digital inputs 24 V DC f Connection of sensors in 2, 3, and 4-wire technology f Maximum permissible load current per sensor 250 mA
Product descriptionThe Inline terminal acquires digital input signals, e.g. from buttons, limit or proximity switches.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDI4******-KB
Technical dataDigital inputs 4
Connection type Spring-cage connection
Nominal input voltage UIN V DC 24
Nominal input current at UIN mA Min. 3
Sensor connection type 2, 3, and 4-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 44
Dimensions (including plug) (W x H x T) mm 12.2 x 141 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
34
Inline terminal with 8 digital inputs R-IB IL 24 DI 8-PAC
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 digital inputs 24 V DC f Connection of sensors in 2, 3, and 4-wire technology f Maximum permissible load current per sensor 250 mA
Product descriptionThe Inline terminal acquires digital input signals, e.g. from buttons, limit or proximity switches.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDI8******-KB
Technical dataDigital inputs 8
Connection type Spring-cage connection
Nominal input voltage UIN V DC 24
Nominal input current at UIN mA Min. 3
Sensor connection type 2, 3, and 4-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C —25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 118
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
35
Rexroth Inline terminal with 16 digital inputs R-IB IL 24 DI 16-PAC
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 16 digital inputs 24 V DC f Connection of sensors in 2 and 3-wire technology f Maximum permissible load current per sensor 250 mA
Product descriptionThe Inline terminal acquires digital input signals, e.g. from buttons, limit or proximity switches.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDI16*****-KB
Technical data Digital inputs 16
Connection type Spring-cage connection
Nominal input voltage UIN V DC 24
Nominal input current at UIN mA Min. 3
Sensor connection type 2, 3-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 121
Dimensions (including plug) (W x H x T) mm 48.8 x 141 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
36
Rexroth Inline terminal with 32 digital inputs R-IB IL 24 DI 32/HD-PAC
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 32 digital inputs 24 V DC f Connection of sensors in 1-wire technology
Product descriptionThe Inline terminal acquires digital input signals, e.g. from buttons, limit or proximity switches.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDI32/HD**-KB
Technical data Digital inputs 32
Connection type Spring-cage connection
Nominal input voltage UIN V DC 24
Nominal input current at UIN mA 2.8
Sensor connection type 1-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 125
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
37
f Protection to IP20 f Max. output current per channel 2 A f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 2 digital outputs 24 V DC, 2 A f Connection of actuators in 2, 3, and 4-wire technology f Short-circuit and overload protected outputs f Approved for use in a safety-related segment circuit
Product descriptionThe Inline terminal is used to actuate solenoid valves, contactors, encoders, relays, or other electrical loads. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDO2*2A***-KB
Rexroth Inline terminal with 2 digital outputs R-IB IL 24 DO 2-2A-PAC
Technical data Digital outputs 2
Connection type Spring-cage connection
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 2
Total current of outputs A 4
Actuator connection type 2, 3, and 4-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 46
Dimensions (including plug) (W x H x T) mm 12.2 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
38
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 4 digital outputs 24 V DC, 500 mA f Connection of actuators in 2 and 3-wire technology f Short-circuit and overload protected outputs
Product descriptionThe Inline terminal outputs digital signals.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDO4******-KB
Rexroth Inline terminal with 4 digital outputs R-IB IL 24 DO 4-PAC
Technical dataDigital outputs 4
Connection type Spring-cage connection
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 0.5
Total current of outputs A 2
Actuator connection type 2, 3-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 46
Dimensions (including plug) (W x H x T) mm 12.2 x 141 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
39
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 digital outputs 24 V DC, 500 mA f Connection of actuators in 2, 3, and 4-wire technology f Short-circuit and overload protected outputs f Approved for use in a safety-related segment circuit
Product descriptionThe Inline terminal outputs digital signals.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDO8******-KB
Rexroth Inline terminal with 8 digital outputs R-IB IL 24 DO 8-PAC
Technical dataDigital outputs 8
Connection type Spring-cage connection
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 0.5
Total current of outputs A 4
Actuator connection type 2, 3, and 4-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 46
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
40
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 digital outputs 24 V DC, 500 mA f Connection of actuators in 1-wire technology f Short-circuit and overload protected outputs
Product descriptionThe Inline terminal outputs digital signals.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-IL24DO8*HD*-DA
Rexroth Inline terminal with 8 digital outputs R-IB IL 24 DO 8/HD-PAC
Technical dataDigital outputs 8
Connection type Spring-cage connection
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 0.5
Total current of outputs A 4
Actuator connection type 1-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 60
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
41
f Protection to IP20 f Max. output current per channel 2 A f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 digital outputs 24 V DC, 2 A f Connection of actuators in 2, 3, and 4-wire technology f Short-circuit and overload protected outputs f Approved for use in a safety-related segment circuit
Product descriptionThe Inline terminal is used to actuate solenoid valves, contactors, encoders, relays, or other electrical loads. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDO8*2A***-KB
Rexroth Inline terminal with 8 digital outputs R-IB IL 24 DO 8-2A-PAC
Technical data Digital outputs 8
Connection type Spring-cage connection
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 2
Total current of outputs A 8
Actuator connection type 2, 3, and 4-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 130
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
42
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 16 digital outputs 24 V DC, 500 mA f Connection of actuators in 2 and 3-wire technology f Short-circuit and overload protected outputs
Product descriptionThe Inline terminal outputs digital signals.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDO16*****-KB
Rexroth Inline terminal with 16 digital outputs R-IB IL 24 DO 16-PAC
Technical dataDigital outputs 16
Connection type Spring-cage connection
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 0.5
Total current of outputs A 8
Actuator connection type 2, 3-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 130
Dimensions (including plug) (W x H x T) mm 48.8 x 141 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
43
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 32 digital outputs 24 V DC, 500 mA f Connection of actuators in 1-wire technology f Short-circuit and overload protected outputs
Product descriptionThe Inline terminal outputs digital signals.The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILDO32/HD**-KB
Rexroth Inline terminal with 32 digital outputs R-IB IL 24 DO 32/HD-PAC
Technical dataDigital outputs 32
Connection type Spring-cage connection
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 0.5
Total current of outputs A 8
Actuator connection type 1-wire connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 135
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
44
f Protection to IP20 f Main supply voltage UM
f Segment supply voltage US
f Diagnostic indicator f Accessories included
(connection plug and labeling fi eld)
Features f 24 V main voltage supply UM
f 24 V segment voltage supply US
f Supply voltage range 19.2 ... 30 V DC f Main and segment circuits can be protected via an
external fuse
Product descriptionThe Inline terminal supplies 24 V power to the main circuit (UM). In addition, this terminal can be used to supply 24 V power for a segment circuit (US). It is connected locally to the control or decentrally in a series to an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILPWRIN****-KB
Rexroth Inline power terminal R-IB IL 24 PWR IN-PAC
Technical dataMain supply voltage UM V DC 24
Power supply at UM A Max. 8
Segment supply voltage US V DC 24
Power supply at US A Max. 8
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 44
Dimensions (including plug) (W x H x T) mm 12.2 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
45
Features f Supplies all 24 V DC voltages required for the low-level
signal of an Inline station f Supply voltage range 19.2 ... 30 V DC
Product descriptionThe terminal is designed for use within an Inline station. If the maximum current-carrying capacity of the potential terminal UL is reached, this terminal is used to feed the logic voltage. A 24 V DC voltage (U24V) is applied at the terminal, which is used to supply the logic voltage (UL) and supply voltage for the analog terminals (UANA). In addition, the terminal can be used to feed the 24 V DC main voltage (UM) and segment voltage (US).
Detailed information:Data sheet DOK-CONTRL-ILPWRIN/R**-KB
f Protection to IP20 f Main supply voltage UM
f Voltages UL, US, and UANA
f Diagnostic indicators f Accessories included
(connection plug and labeling fi eld)
Rexroth Inline boost terminal for logic voltage R-IB IL 24 PWR IN/R-PAC
Technical dataMain supply voltage UM V DC 24
Power supply at UM A Max. 8
Segment supply voltage US V DC 24
Power supply at US A Max. 8
Power supply at UL A Max. 2
Peripheral supply voltage UANA V DC 24
Power supply at UANA A Max. 0.5
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 192
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
46
f Protection to IP20 f Creation of a segment circuit f Segment circuit protection f Diagnostic indicators f Accessories included
(connection plug and labeling fi eld)
Features f Automatic creation of a segment circuit within the main
circuit f Segment circuit protected by internal fuse
Product descriptionThe terminal is designed for use within an Inline station. It is used to create aprotected partial circuit (segment circuit) within the main circuit. The terminal is not used to supply power and there-fore has no elements for protection against polarity reversal and surge voltage.
Detailed information:Data sheet DOK-CONTRL-ILSEG/F****-KB
Rexroth Inline segment terminal R-IB IL 24 SEG/F-PAC
Technical dataFuse A 6.3
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 59
Dimensions (including plug) (W x H x T) mm 12.2 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
47
Features f 24 V DC supply for sensors with 1-wire connection
Product descriptionThe terminal is designed for use within an Inline station and enables feeding out of 24 V supply voltage from the seg-ment circuit (US). It thus permits 24 V supply from US for sensors connected via 1-wire technology to the terminal R-IB IL 24 DI 32/HD-PAC.
Detailed information:–
f Protection to IP20 f Outfeeding Us
f Diagnostic indicators f Accessories included
(connection plug and labeling fi eld)
Inline potential distributor R-IB IL PD 24V-PAC
Technical dataPermissible current from UM A Max. 8
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 44
Dimensions (including plug) (W x H x T) mm 12.2 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
48
Features f 4 digital inputs 24 V DC and 5 V DC f 1 digital output f Connection of sensors in 2, 3, and 4-wire technology f 1 switching output f 2-wire actuator connection
Product descriptionThe Inline terminal acquires and processes fast pulse trains from sensors. It has a counter input, control input, and a freely confi gurable switching output, which is set indepen-dently of the module. This permits fast reaction times that do not depend on the bus and control. The terminal can be operated in four diff erent operating modes. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILCNT******-KB
f Protection to IP20 f Four diff erent operating modes f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Rexroth Inline counter module R-IB IL CNT-PAC
Technical dataCounter inputs/control inputs 2
Connection type Spring-cage connection
Input voltage V DC 5/24
Operating modes Event counter, frequency/time measurement, pulse generator
Output 1
Nominal output voltage UOut V DC 24
Nominal current INom A 0.5
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 110
Dimensions (including plug) (W x H x T) mm 24.4 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
49
f Protection to IP20 f Incremental encoder input f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 3 digital inputs 24 V DC f Connection of sensors in 2 and 3-wire technology f Incremental encoder input f 5 V and 24 V encoder supply, including monitoring f Direction of rotation indicator via LED
Product descriptionThe Inline terminal is used to determine positions (lengths) or angular positions with relative encoder systems, i.e., it reads position or angular information from incremental enco-ders with square-wave signals. Both symmetrical encoders (RS422) and asymmetrical encoders with square-wave sig-nals can be connected to the terminal.Rotary transducers or linear encoders can be read. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILINC*IN***-KB
Rexroth Inline terminal for incremental encoder R-IB IL INC-IN-PAC
Technical dataEncoder detection 1 (incremental encoder)
Input description Symmetrical (RS422) or asymmetrical (3.5 ...27 V)
Digital inputs 3
Nominal input voltage UIN V DC 24
Sensor connection type 2, 3-wire connection
Digital outputs 1
Output type NPN (switches against ground)
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 90
Dimensions (including plug) (W x H x T) mm 24.4 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
50
Features f 1 encoder input f 5 V DC encoder supply f Support for single-turn, multi-turn, or linear encoders f Processing of gray or binary code
Product descriptionThe Inline terminal is used to read data from absolute encoders with SSI interface up to 25 bits (single-turn, multi-turn, or linear encoders). The R-IB IL SSI-IN increases operational reliability by automatically checking data received at the SSI interface for parity. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILSSIIN****-KB
f Protection to IP20 f For absolute encoders with SSI interface f Terminal confi gurable for 8 ... 25 bits f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Rexroth Inline terminal for absolute encoder with SSI interface R-IB IL SSI-IN-PAC
Technical dataEncoder detection 1
Encoder type Single-turn, multi-turn, or linear encoders with SSI interface
Connection type Spring-cage connection
Resolution bits 8 ... 25 (confi gurable)
kHz 100/200/400/800
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 71
Dimensions (including plug) (W x H x T) mm 12.2 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
51
f Protection to IP20 f Connection of resistive temperature sensors f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 2 analog inputs f Supported sensor types
Pt, Ni, Cu, KTY f Connection of sensors in 2, 3, and 4-wire technology
Product descriptionThe Inline terminal acquires resistive temperature sensor signals. It supports platinum and nickel sensors according to the DIN standard and the SAMA directive. In addition, Cu10, Cu50, Cu53, KTY81, and KTY84 sensors are suppor-ted. Temperature measurements are displayed via 16 bit values in two process data words (one word per channel). The terminal is connected locally to the control or decen-trally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILTEMP2RTD*-KB
Rexroth Inline terminal with 2 inputs for temperature sensors R-IB IL TEMP 2 RTD-PAC
Technical dataAnalog inputs 2
Connection type Spring-cage connection
Supported sensor types Pt, Ni, Cu, KTY
Accuracy °C ±0.26
Sensor connection type 2, 3, and 4-wire connection
Resolution of measurements bits 16
Process data update ms 30
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 46
Dimensions (including plug) (W x H x T) mm 12.2 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
52
Features f 2 analog inputs f Supported sensor types
B, C, E, J, K, L, N, R, S, T, U, W, HK f Absolute or diff erential temperature measurement f Connection of sensors in 2-wire technology
Product descriptionThe Inline terminal acquires signals from conventional thermocouples. 13 diff erent thermocouple types are sup-ported according to DIN EN 60584-1 and DIN 43710, and a linear voltage input of -15 mV to +85 mV. It is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILTEMP2UTH*-KB
f Protection to IP20 f Connection of thermocouples f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Rexroth Inline terminal with 2 inputs for thermocouples R-IB IL TEMP 2 UTH-PAC
Technical dataAnalog inputs 2
Connection type Spring-cage connection
Supported sensor types B, C, E, J, K, L, N, R, S, T, U, W, HK
Accuracy °C ±0.6
Sensor connection type 2-wire connection
Resolution of measurements bits 15 (incl. sign bit)
Process data update ms Max. 30 (for both channels)
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 67
Dimensions (including plug) (W x H x T) mm 12.2 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
53
f Protection to IP20 f Connection of resistive temperature sensors f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 8 analog inputs f Supported sensor types Pt, Ni, Cu, KTY f High-precision temperature measurement f Connection of sensors in 4-wire technology
Product descriptionThe Inline terminal provides an 8-channel acquisition module with three linear resistance ranges for resistive temperature sensors.Temperature measurements are displayed via 16 bit values in four process data words using a multiplex technique. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILTEMP4/8RT-KB
Rexroth Inline terminal with 8 resistive temperature inputs R-IB IL TEMP 4/8 RTD/EF-PAC
Technical dataAnalog inputs 8
Connection type Spring-cage connection
Supported sensor types Pt, Ni, Cu, KTY, linear resistors
Accuracy °C ±0.05
Sensor connection type 4-wire connection
Resolution of measurements bits 16
Process data update s 1.8 (up to 3.3 depending on the operating mode)
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 125
Dimensions (including plug) (W x H x T) mm 48.8 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
54
f Protection to IP20 f Connecting Fieldline Modular to an Inline station f Diagnostic indicator f Accessories included
(connection plug and labeling fi eld)
Features f Connection for bus cables from the hybrid cable f Conversion of the physical transmission method of the
Inline local bus to the physical transmission method of the Fieldline Modular local bus
Product descriptionThe Inline terminal is used to connect devices from the Fieldline Modular local bus family or to open a new row for an Inline station. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILFLM******-KB
Rexroth Inline branch terminal to connect Fieldline Modular R-IB IL 24 FLM-PAC
Technical dataHybrid cable connection Spring-cage connection
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 43
Dimensions (including plug) (W x H x T) mm 12.2 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
55
Features f Installed at the beginning of a new row of an Inline
station f Voltage supply for Inline station
Product descriptionThe Inline branch terminal is used to open a new row in an Inline local bus. This can be accomplished in an Inline station in combination with the R-IB IL 24 FLM-PAC. All voltages required in the Inline station can be supplied using the R-IB IL 24 LSKIP-PAC.
Detailed information:Data sheet DOK-CONTRL-ILLSKIP****-KB
f Protection to IP20 f Opens a new row for an Inline station f Subsequent supply of low-level voltages possible f Diagnostic indicator f Accessories included
(connection plug and labeling fi eld)
Rexroth Inline extension terminal for extending the Inline local bus R-IB IL 24 LSKIP-PAC
Technical dataMain supply voltage UM V DC 24
Power supply at UM A Max. 8
Segment supply voltage US V DC 24
Power supply at US A Max. 8
Power supply at UL A Max. 2
Peripheral supply voltage UANA V DC 24
Power supply at UANA A Max. 0.5
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 207
Dimensions (including plug) (W x H x T) mm 48.8 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
56
Features f Number of data bits, stop bits, and parity can be set f 4 KB receiver buff er and 1 KB transmitter buff er f Parameterization and data exchange via the bus using
process data
Product descriptionThe Inline terminal is used to operate standard peripheral devices with a serial interface (RS232) on a bus system. Parameterization and data exchange is carried out via the bus using process data. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILRS232*P**-KB
f Protection to IP20 f Serial RS232 interface f Transmission rate adjustable to 38400 baud f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Rexroth Inline terminal for serial data transfer R-IB IL RS232-PRO-PAC
Technical data Serial interface RS232
Connection type Spring-cage connection
Transmission rate adjustable to kBaud 38.4
Receiver buff er kByte 4
Transmitter buff er kByte 1
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 90
Dimensions (including plug) (W x H x T) mm 24.4 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
57
f Protection to IP20 f Serial RS485 or RS422 interface f Transmission rate adjustable to 38400 baud f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f Number of data bits, stop bits, and parity can be set f 4 KB receiver buff er and 1 KB transmitter buff er f Parameterization and data exchange via the bus using
process data
Product descriptionThe Inline terminal is used to operate standard peripheral devices with a serial interface (RS485/RS422) on a bus system. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Detailed information:Data sheet DOK-CONTRL-ILRS485*P**-KB
Rexroth Inline terminal for serial data transfer R-IB IL RS485/422-PRO-PAC
Technical dataSerial interface RS485/RS422
Connection type Spring-cage connection
Transmission rate adjustable to kBaud 38.4
Receiver buff er kByte 4
Transmitter buff er kByte 1
Local bus connection type Inline data jumper
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 90
Dimensions (including plug) (W x H x T) mm 24.4 x 135 x 71.5
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
58
Detailed information:–
f Protection to IP20 f Diagnostic and status indicators f Accessories included
(connection plug and labeling fi eld)
Features f 4 IO-Link ports f 4 outputs operable in SIO mode f 12 digital inputs 24 V DC f Connection of sensors in 2 and 3-wire technology
Product descriptionThe Inline terminal is used to operate IO-Link-compatible sensors and actuators (devices). It is also used to acquire digital signals. IO-Link is the standard for continuous com-munication from the control to the lowest fi eld level. The terminal is connected locally to the control or decentrally via an Inline fi eldbus coupler.
Inline IO-Link Master R-IB IL 24 IOL 4 DI 12-PAC
Technical dataIO-Link port 4
Nominal current per IO-Link port mA 200
Nominal current per device mA 800
Digital inputs 12
Connection type Spring-cage connection
Nominal input voltage UIN V DC 24
Nominal input current at UIN mA 2.2
Sensor connection type 2, 3-wire connection
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight (without plug) g 200
Dimensions (including plug) (W x H x T) mm 48.8 x 120 x 71.5
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
59
Features f 4 shielded analog diff erential signal inputs or
4 universal RTD inputs,acquisition of current and voltage signals
f 2 analog outputs,outputting of current and voltage signals
Product descriptionThe Inline block module is designed for use within a ser-cos III network. It is used to acquire analog input signals and output analog signals. The module is connected decen-trally to the control via the sercos III network.
Detailed information:Data sheet DOK-CONTRL-S3AI4AO2***-KB
f Protection to IP20 f sercos III interface f Diagnostic and status indicators
Rexroth Inline block IO for sercos III with analoginputs and outputs R-ILB S3 AI4 AO2
Technical dataSupply voltage V DC 24
Fieldbus system SERCOS III
Connection type RJ45
Analog inputs 4
Sensor connection type 2, 3, and 4-wire connection
Analog outputs 2
Actuator connection type 2-wire connection
Resolution of measurements bits 16
Permissible temperature (operation) °C —25 ... +60
Permissible relative humidity (operation) % 10 ... 95, no dewing
Weight g 465
Dimensions (including plug) (W x H x T) mm 155.8 x 138 x 59
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
60
f Protection to IP20 f sercos III interface f Diagnostic and status indicators
Features f 12 analog inputs,
acquisition of current and voltage signals f 4 analog outputs,
outputting of current and voltage signals f Connection of sensors/actuators in 2 and 3-wire techno-
logy f 4 SSI interfaces
Product descriptionThe module is designed for use within asercos III network. It is used to acquire analog input signals and output analog signals. The SSI interfaces enable data to be read out from absolute encoders with SSI interface up to 31 bits. The interfaces support encoders with gray and binary coding. The axis module is decentrally connec-ted to the control via the sercos III network.
Detailed information:Data sheet DOK-CONTRL-S3AI*AO*SSI-DA
Rexroth Inline block IO for sercos III with analog I/Os and SSI interfaces R-ILB S3 AI12 AO4 SSI-IN4
Technical dataSupply voltage V DC 24
Fieldbus system SERCOS III
Connection type RJ45
Encoder detection 4
Encoder type Single-turn, multi-turn, or linear encoders with SSI interface
Analog inputs 12
Analog outputs 4
Resolution of measurements bits 16
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 10 ... 95, no dewing
Weight g 505
Dimensions (including plug) (W x H x T) mm 155.8 x 141 x 59
For ordering information on GoTo products, see Seite 90
IP20 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
61
f Protection to IP20 f sercos III interface f Diagnostic and status indicators
Features f 16/32 digital inputs 24 V DC f Maximum permissible load current per sensor 125 mA f 16 digital outputs 24 V DC, 500 mA f Short-circuit and overload protected outputs f Connection of sensors/actuators in 2 and 3-wire techno-
logy
Product descriptionThe Inline block module is designed for use within a ser-cos III network. It is used to acquire digital input signals and output digital signals. The module is connected decen-trally to the control via the sercos III network.
Detailed information:Data sheet DOK-CONTRL-S3DI16DIO16-KB
Rexroth Inline block IO for sercos III with digital I/Os R-ILB S3 24 DI16 DIO16
Technical dataSupply voltage V DC 24
Fieldbus system SERCOS III
Connection type RJ45
Digital inputs 16/32
Sensor connection type 2, 3-wire connection
Digital outputs 16
Actuator connection type 2, 3-wire connection
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight g 500
Dimensions (including plug) (W x H x T) mm 155.8 x 141 x 55
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP20
Bosch Rexroth AG, R999000281, 2014-05
62
Features f 16 digital inputs 24 V DC f Maximum permissible load current per sensor 125 mA f 16 digital outputs 24 V DC, 500 mA f Short-circuit and overload protected outputs f Connection of sensors/actuators in 2 and 3-wire techno-
logy
Product descriptionThe Inline block module is designed for use within a PROFI-BUS network. It is used to acquire digital input signals and output digital signals. The module is connected decentrally to the control via the PROFIBUS network.
Detailed information:Data sheet DOK-CONTRL-PBDI16/DO16-KB
f Protection to IP20 f PROFIBUS DP interface f Diagnostic and status indicators
Module from the Rexroth Inline block IO product family for PROFI-BUS R-ILB PB 24 DI16 DO16
Technical dataSupply voltage V DC 24
Fieldbus system PROFIBUS DP
Connection type 9-pin D-SUB socket
PROFIsafe support No
Digital inputs 16
Sensor connection type 2, 3-wire connection
Digital outputs 16
Actuator connection type 2, 3-wire connection
Permissible temperature (operation) °C ‒25 ... +55
Permissible relative humidity (operation) % 5 ... 90, no dewing
Weight g 500
Dimensions (including plug) (W x H x T) mm 155.8 x 141 x 55
For ordering information on GoTo products, see Seite 90
IP67 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
63
Rexroth IndraControl S67 PROFINET coupler with 8 digital inputs (M8) S67-PN-BK-DI8-M8
f Protection to IP67 f PROFINET IO device interfaces f M12 connector f Diagnostic and status indicators f Accessories included (module and channel labeling,
M8 protective caps)
Features f 8 digital inputs 24 V DC f Connection of sensors in 2 and 3-wire technology f Parameterization via GSDML f Lockable display panel
(operating mode and address switch) f Optional carrier rail and profi le mounting
Product descriptionThe fi eldbus coupler connects IndraControl S67 I/O modu-les to PROFINET IO. It is equipped with 8 digital inputs. The fi eldbus coupler supports up to 64 modules on the local system bus. The maximum distance between two modules is 50 meters with a maximum total distribution of 500 meters per station.
Detailed information:Instructions DOK-CONTRL-S67PNBKDI8*-AP
Technical data Supply voltage V DC 24
Fieldbus system PROFINET IO
Connection type M12 connector, D-coded, 5-pin
Digital inputs 8
Nominal input voltage UIN V DC 24
Connection type M8 connector, A-coded, 3-pin
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Max. local bus users 64
Permissible temperature (operation) °C –25 ... +60
Weight g 330
Dimensions (including plug) (W x H x T) mm 75 x 117 x 35
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP67
Bosch Rexroth AG, R999000281, 2014-05
64
Rexroth IndraControl S67 PROFIBUS coupler with 8 digital inputs (M8) S67-PB-BK-DI8-M8
f Protection to IP67 f PROFIBUS DP-V1 slave interfaces f M12 connector f Diagnostic and status indicators f Accessories included (module and channel labeling,
M8 protective caps)
Features f 8 digital inputs 24 V DC, M8 f Connection of sensors in 2 and 3-wire technology f Parameterization via GSD f Lockable display panel
(operating mode and address switch)
Product descriptionThe fi eldbus coupler connects IndraControl S67 I/O modu-les to PROFIBUS DP. It is equipped with 8 digital inputs. The fi eldbus coupler supports up to 64 modules on the local system bus. The maximum distance between two modules is 50 meters with a maximum total distribution of 500 meters per station.
Detailed information:Instructions DOK-CONTRL-S67PBBKDI8*-AP
Technical dataSupply voltage V DC 24
Fieldbus system PROFIBUS DP-V1
Connection type M12 connector, D-coded, 5-pin
Digital inputs 8
Nominal input voltage UIN V DC 24
Connection type M8 connector, A-coded, 3-pin
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Max. local bus users 64
Permissible temperature (operation) °C –25 ... +60
Weight g 330
Dimensions (including plug) (W x H x T) mm 75 x 117 x 35
For ordering information on GoTo products, see Seite 90
IP67 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
65
Product descriptionThe IndraControl S67 module acquires analog voltage or current signals. It is connected decentrally via an IndraControl S67 fi eldbus coupler.Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities.The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
f Protection to IP67 f M12 connector
Features f 4 analog inputs f 4x M12 connectors f Connection of sensors in 2, 3, and 4-wire technology
Detailed information:Instructions DOK-CONTRL-S67AI4UI***-AP
Rexroth IndraControl S67 analog module with 4 inputs, voltage/current (4xM12) S67-AI4-U/I-M12
Technical dataSensor connection type 2, 3, and 4-wire connection
Supply voltage V DC 24
Supply voltage range V DC 18 ... 31.2
Voltage input range V DC 0 ... 10/±10
Current input range mA 0 ... 20/±20/4 ... 20
Permissible temperature (operation) °C —25 ... +60
Weight g 230
For ordering information on GoTo products, see Seite 90
GoTo Europe | E/A Komponenten | IP67
Bosch Rexroth AG, R999000281, 2014-05
66
f Protection to IP67 f M12 connector
Features f 4 analog outputs f 4x M12 connectors f Connection of actuators in 2, 3, and 4-wire technology
Detailed information:Instructions DOK-CONTRL-S67AO4UI***-AP
Rexroth IndraControl S67 analog module with 4 outputs, voltage/current (4xM12) S67-AO4-U/I-M12
Technical dataActuator connection type 2, 3, 4-wire connection
Supply voltage V DC 24
Supply voltage range V DC 18 ... 31.2
Voltage output range V DC 0 ... 10±10
Current output range mA 0 ... 20/±20/4 ... 20
Permissible temperature (operation) °C —25 ... +60
Weight g 230
Product descriptionThe IndraControl S67 module is used to output analog voltage or current signals. It is connected decentrally via an IndraControl S67 fi eldbus coupler. Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities. The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
For ordering information on GoTo products, see Seite 91
IP67 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
67
Rexroth IndraControl S67 digital module with 8 inputs (8xM8) S67-DI8-M8
f Protection to IP67 f Diagnostic and status indicators f Accessories included (module and channel labeling,
M8 protective caps)
Features f 8 digital inputs 24 V DC f 8x M8 connectors f Connection of sensors in 2 and 3-wire technology f Optional carrier rail and profi le mounting
Product descriptionThe IndraControl S67 module acquires digital input signals, e.g. from buttons, limit or proximity switches. It is connec-ted decentrally via an IndraControl S67 fi eldbus coupler. Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities. The maxi-mum distance between two modules within an Indra-Control S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67DI8M8***-AP
Technical data Digital inputs 8 (8x M8)
Connection type M8 connector, A-coded, 4-pin
Nominal input voltage UIN V DC 24
Nominal input current at UIN mA 7.3
Sensor connection type 2, 3-wire connection
Local bus connection type M12 connector, B-coded, 3-pin, shielded
Permissible temperature (operation) °C ‒25 ... +60
Weight g 230
Dimensions mm 50 x 117 x 35
For ordering information on GoTo products, see Seite 91
GoTo Europe | E/A Komponenten | IP67
Bosch Rexroth AG, R999000281, 2014-05
68
Rexroth IndraControl S67 digital module with 8 inputs (4xM12) S67-DI8-M12
f Protection to IP67 f M12 connector f Diagnostic and status indicators f Accessories included (module and channel labeling,
M12 protective caps)
Features f 8 digital inputs 24 V DC f 4x M12 connectors (two inputs per connector) f Connection of sensors in 2 and 3-wire technology f Optional carrier rail and profi le mounting
Product descriptionThe IndraControl S67 module acquires digital input signals, e.g. from buttons, limit or proximity switches. It is connec-ted decentrally via an IndraControl S67 fi eldbus coupler. Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities. The maxi-mum distance between two modules within an Indra-Control S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67DI8M12**-AP
Technical data Digital inputs 8 (4x M12, two inputs per connector)
Connection type M12 connector, A-coded, 4-pin
Nominal input voltage UIN V DC 24
Nominal input current at UIN mA 7.3
Sensor connection type 2, 3-wire connection
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Permissible temperature (operation) °C ‒25 ... +60
Weight g 230
Dimensions (including plug) (W x H x T) mm 50 x 117 x 35
For ordering information on GoTo products, see Seite 91
IP67 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
69
f Protection to IP67 f Diagnostic and status indicators f Accessories included (module and channel labeling,
M8 protective caps)
Features f 8 digital outputs 24 V DC, 500 mA f 8x M8 connectors f Connection of actuators in 2 and 3-wire technology f Optional carrier rail and profi le mounting
Product descriptionThe IndraControl S67 module outputs digital signals. It is connected decentrally via an IndraControl S67 fi eldbus coupler. Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities. The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67DO8M8**-AP
Rexroth IndraControl S67 digital module with 8 outputs – 0.5 A (8xM8) S67-DO8-M8
Technical dataDigital outputs 8
Connection type M8 connector, 3-pin
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 0.5
Total current of outputs A 4
Actuator connection type 2, 3-wire connection
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Permissible temperature (operation) °C ‒25 ... +60
Weight g 230
Dimensions (including plug) (W x H x T) mm 50 x 117 x 35
For ordering information on GoTo products, see Seite 91
GoTo Europe | E/A Komponenten | IP67
Bosch Rexroth AG, R999000281, 2014-05
70
f Protection to IP67 f Max. output current per channel 2 A f Diagnostic and status indicators f Accessories included (module and channel labeling,
M8 protective caps)
Features f 8 digital outputs 24 V DC, 2 A f 8x M8 connectors f Connection of actuators in 2 and 3-wire technology f Optional carrier rail and profi le mounting
Product descriptionThe IndraControl S67 module is used to actuate solenoid valves, contactors, encoders, relays, or other electrical loads. It is connected decentrally via an IndraControl S67 fi eldbus coupler. Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities. The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67DO8M82A*-AP
Rexroth IndraControl S67 digital module with 8 outputs – 2.0 A (8xM8) S67-DO8-M8-2A
Technical dataDigital outputs 8
Connection type M8 connector, 3-pin
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 2
Total current of outputs A 8
Actuator connection type 2, 3-wire connection
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Permissible temperature (operation) °C ‒25 ... +60
Weight g 230
Dimensions (including plug) (W x H x T) mm 50 x 117 x 35
For ordering information on GoTo products, see Seite 91
IP67 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
71
f Protection to IP67 f Diagnostic and status indicators f Accessories included (module and channel labeling,
M12 protective caps)
Features f 8 digital outputs 24 V DC, 500 mA f 4x M12 connectors (two inputs per connector) f Connection of actuators in 2 and 3-wire technology f Optional carrier rail and profi le mounting
Product descriptionThe IndraControl S67 module outputs digital signals. It is connected decentrally via an IndraControl S67 fi eldbus coupler. Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities. The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67DO8M12**-AP
Rexroth IndraControl S67 digital module with 8 outputs – 0.5 A (4xM12) S67-DO8-M12
Technical dataDigital outputs 8 (4x M12, two inputs per connector)
Connection type M12 connector, 3-pin
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 0.5
Total current of outputs A 4
Actuator connection type 2, 3-wire connection
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Permissible temperature (operation) °C ‒25 ... +60
Weight g 230
Dimensions (including plug) (W x H x T) mm 50 x 117 x 35
For ordering information on GoTo products, see Seite 91
GoTo Europe | E/A Komponenten | IP67
Bosch Rexroth AG, R999000281, 2014-05
72
f Protection to IP67 f Max. output current per channel 2 A f Diagnostic and status indicators f Accessories included (module and channel labeling,
M12 protective caps)
Features f 8 digital outputs 24 V DC, 2 A f 4x M12 connectors (two inputs per connector) f Connection of actuators in 2 and 3-wire technology f Optional carrier rail and profi le mounting
Product descriptionThe IndraControl S67 module is used to actuate solenoid valves, contactors, encoders, relays, or other electrical loads. It is connected decentrally via an IndraControl S67 fi eldbus coupler.Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities.The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67DO8M122A-AP
Rexroth IndraControl S67 digital module with 8 outputs – 2.0 A (4xM12) S67-DO8-M12-2A
Technical dataDigital outputs 8 (4x M12, two inputs per connector)
Connection type M12 connector, 3-pin
Nominal output voltage UOut V DC 24
Nominal current INom per channel A 2
Total current of outputs A 8
Actuator connection type 2, 3-wire connection
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Permissible temperature (operation) °C ‒25 ... +60
Weight g 230
Dimensions (including plug) (W x H x T) mm 50 x 117 x 35
For ordering information on GoTo products, see Seite 91
IP67 | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
73
f Protection to IP67 f Supply voltage for ULS
f Supply voltage for UA
f Diagnostic indicators f Accessories included (module and channel labeling,
M12 protective caps)
Features f 1 supply input 24 V DC, 16 A
M23 connector f 6 supply outputs 8 A
M12 connector f Supply voltage range 19.2 ... 30 V DC f Optional carrier rail and profi le mounting
Product descriptionThe passive feed module is used to supply voltage to Indra-Control S67 components. Thanks to options including an individual supply or the creation of supply groups, the feed module can supply I/O nodes with a large overall extension. The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67PWRINM12-AP
Rexroth IndraControl S67 power distributor (6xM12) S67-PWR-IN-M12
Technical dataInput 1
Connection type M23 connector, 6-pin
Outputs 6
Connection type M12 connector, A-coded, 4-pin
Logic and sensor supply voltage ULS V DC 24
Actuator supply voltage UA V DC 24
Current carrying capacity, connector A Max. 8 (ULS: 4, UA: 4 )
Current carrying capacity, module A Max. 24 (ULS: 8, UA: 16)
Permissible temperature (operation) °C ‒25 ... +60
Weight (without plug) g 240
Dimensions (including plug) (W x H x T) mm 50 x 117 x 43.3
For ordering information on GoTo products, see Seite 91
GoTo Europe | E/A Komponenten | IP67
Bosch Rexroth AG, R999000281, 2014-05
74
Features f 4 analog inputs f 4x M12 connectors f Supported sensor types Pt, Ni f Connection of sensors in 2, 3, and 4-wire technology f Optional carrier rail and profi le mounting
Product descriptionThe IndraControl S67 module is used to evaluate RTD temperature sensors. It is connected decentrally via an IndraControl S67 fi eldbus coupler. Parameterization is carried out via the fi eldbus coupler and off ers a wide range of diagnostic possibilities. The maximum distance between two modules within an IndraControl S67 station is 50 meters with a maximum total extension of 500 meters.
Detailed information:Instructions DOK-CONTRL-S67AI4RTD**-AP
f Protection to IP67 f Connection of resistive temperature sensors f Diagnostic and status indicators f Accessories included (module and channel labeling,
M12 protective caps)
Rexroth IndraControl S67 analog module with 4 inputs for RTD (4xM12) S67-AI4-RTD-M12
Technical dataAnalog inputs 4
Connection type M12 connector, A-coded, 5-pin
Supported sensor types Pt, Ni
Accuracy °C ±0.05
Sensor connection type 2, 3, and 4-wire connection
Resolution of measurements bits 16
Process data update ms 2 ... 120
Local bus connection type M12 connector, B-coded, 5-pin, shielded
Permissible temperature (operation) °C ‒25 ... +60
Weight (without plug) g 230
Dimensions (including plug) (W x H x T) mm 50 x 117 x 35
For ordering information on GoTo products, see Seite 91
Accessories | E/A Komponenten | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
75
Features f Preassembled cables in standard lengths f Suitable as trailing cable f Socket for self-assembly
Product descriptionPreassembled cables enable convenient, simple, and effi ci-ent wiring of IndraControl S67. The cables and connectors are optimally suited to the requirements of an IP67 system.
Detailed information:–
f Protection to IP67 f Local bus/supply voltage f Simple wiring f Terminating connector f M23 connector
IndraControl S67 – accessories RKB0041
Technical dataLocal bus RKB0041
Connection type M12 socket – M12 connector
Suitable as trailing cable No
Local bus terminating resistor M12 RBS0020/CNN
Supply voltage RKB0046
Connection type M12 connector – M12 socket
Suitable as trailing cable Yes
Supply voltage RKB0047
Connection type M12 socket – open end
Suitable as trailing cable Yes
Voltage supply socket M23 RBS0021/L06
PROFIBUS terminating resistor M12 INS0762/CNN
For ordering information on GoTo products, see Seite 91
GoTo Europe
Bosch Rexroth AG, R999000281, 2014-05
76
Tightening systems | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
77
Tightening systems
Hand-held nutrunnersThe ErgoSpin is designed according to the latest findings in ergonomics and fits the user's hand like a glove. The ergo-nomics of the handle, its light weight, and the optimum arrangement of operating and display elements increase worker productivity.
Control and power electronicsThe hardware platform is based on cutting-edge technology and thus ensures investment security. It has been specially developed for industrial applications. The system box and compact system fully comply with the IP54 protection class.
CablesPrecise control and consistently reliable measurements for monitoring tightening results are the outstanding features of tightening systems from Rexroth. This level of precision requires data transport that is always error-free. This is why the tightening systems from Rexroth are equipped with fully digital data communication.
GoTo Europe | Tightening systems | Hand-held nutrunners
Bosch Rexroth AG, R999000281, 2014-05
78
Features f With integrated powerful LED f Standard tool mounts f Tested for one million cycles under full load without
maintenance
Product descriptionPistolgrip nutrunner for hard-to-reach tightening positions with integrated powerful LED
Detailed information:R999000048 (de) / R999000049 (en)
f Working range 2.4 ... 12 Nm f Maximum output drive speed 1090 rpm f Suitable for function-critical tightening jobs in
accordance with VDI/VDE2862
CC-ErgoSpin hand-held pistolgrip nutrunner for function-critical tightening jobsCC-ESM
Technical dataType CC-ESM012QD
Working range Nm 2.4 ... 12
Max. output drive speed rpm 1090
Tool mount 1/4" quick-change chuck
Weight kg 1
Installation length mm 201
For ordering information on GoTo products, see Seite 91
Hand-held nutrunners | Tightening systems | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
79
Features f Angle head has a non-interchangeable code and
can be turned and locked in 15-degree steps f Integrated LEDs visible all around f Tested for one million cycles under full load
without maintenance
Product descriptionRight-angle nutrunner with slim angle head for high accessi-bility
Detailed information:R999000048 (de) / R999000049 (en)
f Working range 6 ... 40 Nm f Maximum output drive speed 1000 rpm f Suitable for function-critical tightening jobs in
accordance with VDI/VDE2862
CC-ErgoSpin SlimLine hand-held nutrunner for function-critical tightening jobsCC-ESA
Technical dataType CC-ESA030S CC-ESA040S
Working range Nm 6 ... 30 8 ... 40
Max. output drive speed rpm 800 1000
Tool mount 3/8" square 3/8" square
Weight kg 1.6 1.7
Installation length mm 416 434
For ordering information on GoTo products, see Seite 91
GoTo Europe | Tightening systems | Hand-held nutrunners
Bosch Rexroth AG, R999000281, 2014-05
80
Features f Sturdy: IP54, EMC severity level IV f USB and Ethernet interface f Clear system design f Flexible adaptation to new tasks f Clearly arranged control and display elements
Product descriptionThe operating and display units, as well as the connections, are arranged in a user-friendly, modern, and attractive design. The clear structure of the CC-CS351 allows intuitive operation without any complicated configuration. The housing is no larger than a minitower and fully complies with protection class IP54.The CC-CS351 Compact System is only suitable for the operation of CC ErgoSpin hand-held nutrunners.
Detailed information:R999000048 (de) / R999000049 (en)
f For CC-ErgoSpin hand-held nutrunner control f Use in function-critical tightening jobs f Secure and fast commissioning f Tightening results at a glance
Compact System for CC-ErgoSpinCC-CS351
Technical dataType CC-CS351E-D
Weight kg 9.5
Dimensions (W x H x D) mm 210 x 358 x 253
For ordering information on GoTo products, see Seite 91
Control and power electronics | Tightening systems | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
81
For ordering information on GoTo products, see Seite 91
Features f Min. bending radius 130 mm
Detailed information:R999000048 (de) / R999000049 (en)
f Extension up to 5 connection cables f Max. length 50 m
Cables for ErgoSpin hand-held nutrunnersAL/AV
Technical dataType AL003 AL010 AV003
ErgoSpin connection cable Straight – angle Straight – angle Straight – straight
Length m 3 10 3
Product descriptionThe ErgoSpin hand-held nutrunner is connected to the CS351E… or CC-CS351E... Compact System via a connec-tion cable. For extension, up to 5 of the connection cables listed may be connected one after the other in any order. For applications where the hand-held nutrunner is in cons-tant motion, we recommend constructing the connection from several individual parts. The minimum bending radius for the listed connection cables is 130 mm. The max. length is 50 m.
GoTo Europe
Bosch Rexroth AG, R999000281, 2014-05
82
Engineering Software | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
83
Engineering software
Open Core Engineering with IndraWorks – the universal engineering frameworkThe software tools, function packages, and multi-techno-logy solutions associated with Open Core Engineering accelerate the engineering workflow. Open Core Enginee-ring offers benefits in every step of the engineering pro-cess, from initial configuration and programming, to para-meterization, startup, and service. The IndraWorks engineering framework provides a wide array of tools to tackle any engineering project.
With the full language scope offered by PLC programming according to the third edition of IEC 61131-3, as well as PLCopen-compliant motion elements and technology modu-les, the configuration of your automation solutions is fast and simple.
Intuitive wizards guide you through all engineering steps. You get an easy, straightforward approach to configuring cont-rollers and motion axes, even when working offline. Integra-ted configurators are available for the configuration of I/O
peripheral devices. Comprehensive tools for startup or service activities, such as the four-channel oscilloscope, logic analyzer, and debugging functions of the PLC logic, provide several different status messages and system diag-nostics options at the press of a button.
Solution-driven function packages, such as CamBuilder to generate electronic cams or WinStudio for the creation of visualization interfaces, are available within IndraWorks.The Generic Application Template (GAT) creates the ideal prerequisites for the development of modular machine software. Drawing from templates,
GAT works with wizards based on the engineer’s specifica-tions and automatically generates the executable machine program, thus significantly accelerating engineering.With the team engineering function package, several engi-neers can efficiently plan machines and systems simultane-ously thanks to the integration of version control systems.
GoTo Europe | Engineering Software
Bosch Rexroth AG, R999000281, 2014-05
84
f All tools integrated with uniform, central data manage-ment
f Standardized programming according to the PLC stan-dard IEC 61131-3, 3rd edition
f Solution-driven function packages f Intelligent operation with wizard support
Features f Complete basic functions f Powerful cam editor f WinStudio visualization toolbox f Working with version control f Open integration interfaces f Comprehensive online help
Product descriptionFrom simple mini controllers to highly complex motion applications, all the tools for starting up controls are availa-ble within the IndraWorks framework. Intuitive wizards facilitate processing in complex areas. With the Generic Application Template (GAT), you can fully concentrate on your process. Benefi t from the advantages of a predefi ned, modular project structure for developing reusable applica-tions.
Detailed information:Instructions DOK-IWORKS-ENGINEE*V12-AP
Rexroth IndraWorks 12VRS Engineering
Technical dataSystem IndraLogic XLC IndraMotion MLC
Basic Functions Device confi guration, fi rmware management, debugging, diagnostics
PLC programming Complies withIEC 61131-3, 3rd edition
Sequential function chart, ladder diagram, functional block diagram, continuous function chart, instruction list, structured text, object-oriented language extensions
Axis confi gurator Axis types Real, virtual, encoder Real, virtual, encoder, grouped, control
Libraries Basic • •
Technology/technology (industry-specifi c)
•/— •/•
Optional function pa-ckages
CamBuilder o o
WinStudio/VI-Composer o/o o/o
Versions Control System o o
• Default — Not available o Option
For ordering information on GoTo products, see Seite 92
Engineering Software | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
85
Features f Solutions package fully integrated in IndraWorks f Multi-language project creation f Clear selection of objects f Graded software packages for individual adaptation
Product descriptionWinStudio is the innovative visualization module of the powerful IndraWorks software framework for creating user-friendly interfaces.WinStudio allows you to create your individual applications quickly, easily and effi ciently – with one tool for all applica-tions.
f Uniform visualization software f Easy creation of screens with comprehensive libraries f Simple generation of web client applications f Easy project planning without any knowledge of
high-level languages
Detailed information:Instructions DOK-IWORKS-HMI*****V12-AP
Rexroth IndraWorks HMI 12VRSSWS
Technical dataType WinStudio WinStudio WinStudio WinStudio WinStudio WinStudio WinStudio WinStudio
lite 1.5 k 4 k 64 k 512 k lite 1.5 k 4 k
Operating system WinXP/2000 WinXP/2000 WinXP/2000 WinXP/2000 WinXP/2000 WinCE WinCE WinCE
Runtime license Server 2003/Vista
Server 2003/Vista
Server 2003/Vista
Server 2003/Vista
Server 2003/Vista
Max. number of variab-les
500 1,500 4,000 64,000 512,000 500 1,500 4,000
Max. array size 256 256 512 1,024 16,384 256 256 512
Max. number of class elements
32 32 32 64 512 32 32 32
Recipe handling • • • • • • • •
Web clients — 1/4/8 1/4/8 1/4/8 1/4/8 1/4/8 1/4/8
• Default — Not available
For ordering information on GoTo products, see Seite 92
GoTo Europe
Bosch Rexroth AG, R999000281, 2014-05
86
Ordering information | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
87
Ordering information
You can find all available GoTo products with a description and part number on the following pages. You can also view the maximum order quantities as well as delivery periods.
GoTo Europe | Ordering information
Bosch Rexroth AG, R999000281, 2014-05
88
Frequency converterEFC36008 R912003758 EFC3600-0K40-1P2-MDA-7P-NNNN 10 5
R912003759 EFC3600-0K75-1P2-MDA-7P-NNNN 10 5
R912003760 EFC3600-1K50-1P2-MDA-7P-NNNN 10 5
R912003761 EFC3600-2K20-1P2-MDA-7P-NNNN 10 5
R912003762 EFC3600-0K40-3P4-MDA-7P-NNNN 10 5
R912003763 EFC3600-0K75-3P4-MDA-7P-NNNN 10 5
R912003764 EFC3600-1K50-3P4-MDA-7P-NNNN 10 5
R912003765 EFC3600-2K20-3P4-MDA-7P-NNNN 10 5
R912003766 EFC3600-4K00-3P4-MDA-7P-NNNN 10 5
Frequency Converter Fv9 R912005329 FVCA01.2-0K40-3P4-MDA-LP-NNNN-02VRS 3 5
R912005330 FVCA01.2-0K75-3P4-MDA-LP-NNNN-02VRS 3 5
R912005331 FVCA01.2-1K50-3P4-MDA-LP-NNNN-02VRS 3 5
R912005332 FVCA01.2-2K20-3P4-MDA-LP-NNNN-02VRS 3 5
R912005333 FVCA01.2-4K00-3P4-MDA-LP-NNNN-02VRS 3 5
R912005334 FVCA01.2-5K50-3P4-MDA-LP-NNNN-02VRS 3 5
R912005335 FVCA01.2-7K50-3P4-MDA-LP-NNNN-02VRS 2 5
R912005336 FVCA01.2-11K0-3P4-MDA-LP-NNNN-02VRS 2 5
R912005337 FVCA01.2-15K0-3P4-MDA-LP-NNNN-02VRS 2 5
R912005338 FVCA01.2-18K5-3P4-MDA-LP-NNNN-02VRS 1 5
R912005339 FVCA01.2-22K0-3P4-MDA-LP-NNNN-02VRS 1 5
R912005340 FVCA01.2-30K0-3P4-MDA-LP-NNNN-02VRS 1 5
R912005341 FVCA01.2-37K0-3P4-MDA-LP-NNNN-02VRS 1 5
Accessories10 R912004868 FVAA01.2-P-NNNN-01V01 6 5
R912001499 FELB02.1N-30K0-NNONE-A-560-NNNN 1 5
R912001500 FELB02.1N-45K0-NNONE-A-560-NNNN 1 5
R912004563 FELR01.1N-0060-N400R-D-560-NNNN 5 5
R912004566 FELR01.1N-0100-N190R-D-560-NNNN 5 5
R912004569 FELR01.1N-0200-N095R-D-560-NNNN 5 5
R912004572 FELR01.1N-0300-N065R-D-560-NNNN 5 5
R912004575 FELR01.1N-0060-N2K0R-D-560-NNNN 5 5
R912004578 FELR01.1N-0100-N1K0R-D-560-NNNN 5 5
R912004581 FELR01.1N-0200-N500R-D-560-NNNN 5 5
R912004584 FELR01.1N-0300-N330R-D-560-NNNN 5 5
R912004587 FELR01.1N-0500-N180R-D-560-NNNN 5 5
R912001618 FELR01.1N-0080-N750R-D-560-NNNN 2 5
R912001623 FELR01.1N-0260-N250R-D-560-NNNN 2 5
R912001624 FELR01.1N-0260-N400R-D-560-NNNN 2 5
R912001627 FELR01.1N-0390-N150R-D-560-NNNN 2 5
R912001632 FELR01.1N-0520-N100R-D-560-NNNN 2 5
R912001637 FELR01.1N-0780-N075R-D-560-NNNN 1 5
R912001652 FELR01.1N-1K04-N050R-D-560-NNNN 1 5
R912001654 FELR01.1N-1K56-N040R-D-560-NNNN 1 5
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
Ordering information | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
89
R912001630 FELR01.1N-04K8-N27R2-A-560-NNNN 1 5
R912001629 FELR01.1N-04K8-N032R-A-560-NNNN 1 5
R912001635 FELR01.1N-06K0-N020R-A-560-NNNN 1 5
R912001641 FELR01.1N-09K6-N016R-A-560-NNNN 1 5
R912004600 FENF01.1B-A030-E0006-A-240-NNNN 3 5
R912004601 FENF01.1B-A030-E0010-A-240-NNNN 3 5
R912004602 FENF01.1B-A030-E0020-A-240-NNNN 3 5
R912004603 FENF01.1B-A030-E0025-A-240-NNNN 3 5
R912004604 FENF01.1B-A030-E0008-A-480-NNNN 3 5
R912004605 FENF01.1B-A030-E0020-A-480-NNNN 3 5
R912003315 FENF01.1A-A075-E0008-A-480-NNNN 6 5
R912003316 FENF01.1A-A075-E0022-A-480-NNNN 6 5
R912003317 FENF01.1A-A075-E0030-A-480-NNNN 2 5
R912003318 FENF01.1A-A075-E0051-A-480-NNNN 2 5
R912003319 FENF01.1A-A075-E0090-A-480-NNNN 1 5
R912004815 FEAM01.1-EFC-SHIELDING-CONNECTOR 10 5
Automation systemsIndraLogic XLC12 R911334606 FWA-CML25*-XLC-12VRS-D0 5 5
R911334608 FWA-CML45*-XLC-12VRS-D0 5 5
R911334610 FWA-CML65*-XLC-12VRS-D0 5 5
IndraMotion MLC13 R911334607 FWA-CML25*-MLC-12VRS-D0 5 5
R911334609 FWA-CML45*-MLC-12VRS-D0 5 5
R911334611 FWA-CML65*-MLC-12VRS-D0 5 5
Control hardware IndraControl L14 R911171363 CML25.1-3N-400-NN-NNC1-NW 5 5
R911170828 CML45.1-3P-500-NA-NNNN-NW 5 5
R911170900 CML65.1-3P-500-NA-NNNN-NW 5 5
Function modules IndraControl L15 R911170009 CFL01.1-Q2 5 5
R911170008 CFL01.1-R3 5 5
R911170832 CFL01.1-TP 5 5
Accessories— R911299856 R-IB IL CML S01-PLSET 5 5
HMI components18 R911311488 VCP02.2DRN-003-NN-NN-PW 5 5
19 R911311493 VCP05.2DSN-003-NN-NN-PW 5 5
20 R911311509 VCP11.2DWN-003-NN-NN-PW 5 5
21 R911311505 VCP25.2DVN-003-NN-NN-PW 5 5
22 R911171110 VCP35.2ECN-003-NN-NN-PW 5 5
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
GoTo Europe | Ordering information
Bosch Rexroth AG, R999000281, 2014-05
90
I/O componentsIP20 – Inline24 R911170875 R-IL S3 BK DI8 DO4-PAC 10 5
25 R911171944 R-IL PN BK DI8 DO4-PAC 10 5
26 R911172194 R-IL PB BK DI8 DO4/CN-PAC 10 5
27 R911170971 R-IL PB BK DP/V1-PAC 10 5
28 R911170784 R-IB IL AI 2/SF-PAC 10 5
29 R911308493 R-IB IL AI 8/SF-PAC 10 5
30 R911170787 R-IB IL AO 1/SF-PAC 10 5
31 R911170436 R-IB IL AO 2/SF-PAC 10 5
32 R911170786 R-IB IL AO 2/U/BP-PAC 10 5
33 R911170750 R-IB IL 24 DI 4-PAC 10 5
34 R911170751 R-IB IL 24 DI 8-PAC 10 5
35 R911170752 R-IB IL 24 DI 16-PAC 10 5
36 R911170753 R-IB IL 24 DI 32/HD-PAC 10 5
37 R911170754 R-IB IL 24 DO 2-2A-PAC 10 5
38 R911170755 R-IB IL 24 DO 4-PAC 10 5
39 R911170756 R-IB IL 24 DO 8-PAC 10 5
40 R911171973 R-IB IL 24 DO 8/HD-PAC 10 5
41 R911170759 R-IB IL 24 DO 8-2A-PAC 10 5
42 R911170757 R-IB IL 24 DO 16-PAC 10 5
43 R911170768 R-IB IL 24 DO 32/HD-PAC 10 5
44 R911170789 R-IB IL 24 PWR IN-PAC 10 5
45 R911170446 R-IB IL 24 PWR IN/R-PAC 10 5
46 R911170790 R-IB IL 24 SEG/F-PAC 10 5
47 R911297189 R-IB IL PD 24V-PAC 10 5
48 R911170788 R-IB IL CNT-PAC 10 5
49 R911308491 R-IB IL INC-IN-PAC 10 5
50 R911171514 R-IB IL SSI-IN-PAC 10 5
51 R911170785 R-IB IL TEMP 2 RTD-PAC 10 5
52 R911170431 R-IB IL TEMP 2 UTH-PAC 10 5
53 R911173029 R-IB IL TEMP 4/8 RTD/EF-PAC 10 5
54 R911170445 R-IB IL 24 FLM-PAC 10 5
55 R911170948 R-IB IL 24 LSKIP-PAC 10 5
56 R911170440 R-IB IL RS232-PRO-PAC 10 5
57 R911170442 R-IB IL RS485/422-PRO-PAC 10 5
58 R911171971 R-IB IL 24 IOL 4 DI 12-PAC 10 5
59 R911170874 R-ILB S3 AI4 A02 10 5
60 R911171949 R-ILB S3 AI12 AO4 SSI-IN4 10 5
61 R911170826 R-ILB S3 24 DI16 DIO16 10 5
62 R911307402 R-ILB PB 24 DI16 DO16 10 5
IP67 – IndraControl S6763 R911171784 S67-PN-BK-DI8-M8 5 5
64 R911171782 S67-PB-BK-DI8-M8 5 5
65 R911171793 S67-AI4-U/I-M12 5 5
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
Ordering information | GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
91
66 R911171795 S67-AO4-U/I-M12 5 5
67 R911171787 S67-DI8-M8 5 5
68 R911171788 S67-DI8-M12 5 5
69 R911171789 S67-DO8-M8 5 5
70 R911171791 S67-DO8-M8-2A 5 5
71 R911171790 S67-DO8-M12 5 5
72 R911171792 S67-DO8-M12-2A 5 5
73 R911171796 S67-PWR-IN-M12 5 5
74 R911171794 S67-AI4-RTD-M12 5 5
Accessories— R911172352 SUP-M01-ENDHALTER/PA 5 5
— R911171998 RBS0020/CNN (**-*****-****-*****-****) 5 5
— R911172110 RBS0021/L06 (CN-0006S-ROUN-SCREW-****) 5 5
— R911296632 INS0762/CNN (**-*****-****-*****-****) 5 5
75 R911171990 RKB0041/000,2 (*******-*******-*******) 5 5
R911171991 RKB0041/000,3 (*******-*******-*******) 5 5
R911171992 RKB0041/000,5 (*******-*******-*******) 5 5
R911171993 RKB0041/001,0 (*******-*******-*******) 5 5
R911171994 RKB0041/002,0 (*******-*******-*******) 5 5
R911171995 RKB0041/005,0 (*******-*******-*******) 5 5
R911171996 RKB0041/010,0 (*******-*******-*******) 5 5
— R911172100 RKB0047/005,0 (*******-*******-*******) 5 5
R911172101 RKB0047/010,0 (*******-*******-*******) 5 5
R911172102 RKB0046/000,2 (*******-*******-*******) 5 5
R911172103 RKB0046/000,3 (*******-*******-*******) 5 5
R911172104 RKB0046/000,5 (*******-*******-*******) 5 5
R911172105 RKB0046/001,0 (*******-*******-*******) 5 5
R911172106 RKB0046/002,0 (*******-*******-*******) 5 5
R911172107 RKB0046/005,0 (*******-*******-*******) 5 5
R911172108 RKB0046/010,0 (*******-*******-*******) 5 5
Tightening systems78 0608841089 HAND-HELD NUTRUNNER CC-ESM012QD 2.4-12 3 10
79 0608841087 HAND-HELD NUTRUNNER CC-ESA030S 6-30NM 3 10
0608841088 HAND-HELD NUTRUNNER CC-ESA040S 8-40NM 3 10
80 0608830289 SINGLE-CHANNEL CONTROL CC-CS351E-D 3 10
81 0608750102 ELECTR CABLE AL003 E S-A 3 10
0608750105 ELECTR CABLE AL010 E S-A 3 10
0608750115 ELECTR CABLE AV003 E S-S 3 10
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
GoTo Europe | Ordering information
Bosch Rexroth AG, R999000281, 2014-05
92
Engineering software– R911334632 SWA-IWORKS-ML*-12VRS-D0-DVD** 5 5
R911311752 SWA-VIC*PC-INB-02VRS-D0-CD650 5 5
– R911332861 SWL-IWORKS-ML*-NNVRS-D0-ENG 5 5
R911332863 SWL-IWORKS-XLC-NNVRS-D0-ENG 5 5
R911332867 SWL-IWORKS-ML*-NNVRS-D0-COM 5 5
85 R911332869 SWS-IWORKS-CAM-NNVRS-D0 5 5
R911323596 SWS-WINSTU-RUD-07VRS-D0-1K5 5 5
R911323595 SWS-WINSTU-RUD-07VRS-D0-4K 5 5
R911336031 SWS-IWORKS-VCS-NNVRS-D0 5 5
R911336032 SWS-IWORKS-VCS-NNVRS-D0-M10 5 5
R911336033 SWS-IWORKS-VCS-NNVRS-D0-M25 5 5
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
93
Page Part number Type code breakdown Max. GoTo quantity (pcs)
Delivery time (work days)
from plant in Germany
GoTo Europe
Bosch Rexroth AG, R999000281, 2014-05
94
GoTo Europe
R999000281, 2014-05, Bosch Rexroth AG
95
Bosch Rexroth AGBgm.-Dr.-Nebel-Str. 297816 Lohr, GermanyTel. +49(0)9352/18-0 Fax +49(0)9352/[email protected]
You can find local contact information at: www.boschrexroth.com/contact
Material no.: R999000281Version no.: 2014-05© Bosch Rexroth AG 2014Subject to change!
The data in this document are used exclusively for the purpose of product description. As our products are constantly being further developed, no statements concerning a certain condition or suitability for a certain application can be derived from our information. This information does not release users from obligations of exercising their own judgment and conducting their own tests. It must be remembered that our products are subject to a natural process of wear and aging.